Search NASA⌕ Search

SEARCH · Search NASA

Results for “interlaboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An interlaboratory comparison of piston-cylinder pressure calibration using the albite-breakdown reaction.

An attempt is made to compare pressure calibration methods among several laboratories in an unbiased way to produce some indication of the bandwidth of observations on the pressure of an equilibrium reaction where sources of discrepancy not resulting from pressure calibration are likely to have been eliminated. The reaction chosen is the breakdown of albite to jadeite and quartz under pressure.

Johannes, W.↗

Spectral radiance calibrations between 165-300 nm - An interlaboratory comparison

The spectral radiance of deuterium lamps calibrated by the Max-Planck-Institut fuer Astronomie (MPI), by the U.S. National Bureau of Standards (NBS), and by the Physikalisch-Technische Bundesanstalt (PTB) are compared to check the agreement of UV radiometric scales. The NBS group used the optically thin continuum radiation from a wall-stabilized hydrogen arc as its fundamental radiometric standard, while the MPI and PTB groups used the synchrotron radiation facility in DESY. It is found that the spectral radiance scales based upon the DESY synchrotron and the NBS hydrogen arc are consistent, at least for one wavelength relative to another.

Bridges, J. M.↗

Interlaboratory calibration of atmospheric nitrous oxide measurements

Samples representative of Northern Hemispheric conditions in mid-1976 were analyzed by 11 laboratories to resolve the question of the absolute tropospheric concentration of nitrous oxide. The laboratories all employed electron capture-gas chromatography for the analysis. After exclusion of one anomalously low determination, the calibration results showed a mean concentration of 323.5 + or - 8.7 ppb v/v nitrous oxide.

Rasmussen, R. A.↗

The breaking load method - Results and statistical modification from the ASTM interlaboratory test program

The breaking load test provides quantitative stress corrosion cracking data by determining the residual strength of tension specimens that have been exposed to corrosive environments. Eight laboratories have participated in a cooperative test program under the auspices of ASTM Committee G-1 to evaluate the new test method. All eight laboratories were able to distinguish between three tempers of aluminum alloy 7075. The statistical analysis procedures that were used in the test program do not work well in all situations. An alternative procedure using Box-Cox transformations shows a great deal of promise. An ASTM standard method has been drafted which incorporates the Box-Cox procedure.

Colvin, E. L.↗

International cooperation in age-dating uranium standards for nuclear forensics using the 231 Pa/ 235 U radiochronometer

During 2017–2018 Los Alamos National Laboratory, Lawrence Livermore National Laboratory and the China Institute of Atomic Energy collaborated in an interlaboratory 231 Pa/ 235 U radiochronometry exercise. The laboratories used different analytical methods to obtain a consensus model purification date for CRM U010 of December 28, 1958 ± 198 days and for CRM U850 of May 20, 1958 ± 363 days. These results agree with previously reported model dates using the 230 Th/ 234 U radiochronometer as well as the production histories of these materials. The concordance of interlaboratory data here confirms the ability of laboratories to make reproducible radiochronometry measurements using distinct analytical approaches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

US-DOE and Republic of South Africa Uranium Benchmarking: Results From Los Alamos National Laboratory (Study Report)

This report details work performed at Los Alamos National Laboratory (LANL) in support of an interlaboratory uranium (U) benchmarking collaboration between LANL, Lawrence Livermore National Laboratory (LLNL), and South African Nuclear Energy Corporation (Necsa). The goal of this interlaboratory benchmarking exercise is to compare analytical methods and data obtained on uranium reference materials CUP-2 and New Brunswick Laboratory (NBL) certified reference material (CRM) 124-2. The LANL commitments for this project include performing microwave digestion of fresh CUP-2 and CRM 124-2 powders, measuring the U isotope composition of CUP-2 and CRM 124-2 by both single-collector and multi-collector inductively coupled plasma mass spectrometry (SC-ICP-MS and MC-ICP-MS, respectively), and determining trace-element abundances in CUP-2 and CRM 124-2 by inductively coupled plasma mass spectrometry (ICP-MS). This report details the methods employed by LANL in support of these objectives and presents the data obtained during this collaborative exercise.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Precision of Property Measurements with Reference Molten Salts

Thermochemical and thermophysical properties of reference molten salt systems are being measured to establish the precisions achievable with current state-of-the-art methods including repeatability within a laboratory and reproducibility between laboratories using the same and different methods. Several laboratories across the United States are analyzing salt samples from single source batches of two salts to provide independent measurements of property values and the precisions of different measurement techniques in an interlaboratory study referred to as the Interlaboratory Salt Study (ISS). The compositions of the two salts produced for the study were reported to be eutectic LiF-NaF-KF (46.5-11.5-42 mol %) and NaCl-KCl (50-50 mol %). These salts are referred to herein as ISS FLiNaK and ISS NaCl-KCl. Thermochemical properties being measured at Argonne include thermal transitions and heat capacity by differential scanning calorimetry. Thermophysical properties being measured at Argonne include liquid density and surface tension by using a buoyancy densitometer and thermal diffusivity by using a laser flash analyzer. Thermal conductivity is calculated from measured thermal diffusivity, density and heat capacity values. The results of property measurements made at Argonne using these inter-laboratory salt study salts are presented here.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical note: 21 Ne in the CoQtz-N quartz standard material

Intercomparison standards produced from mineral samples exposed to the natural cosmic ray flux are routinely used for interlaboratory comparison and normalization of measurements of the cosmogenic noble gases 3 He and 21 Ne. This effort is facilitated by the availability of multiple standard materials with a wide range of cosmogenic nuclide concentrations. The “CoQtz-N” quartz standard, which was originally produced and distributed as an intercomparison standard for cosmogenic 10 Be and 26 Al, has a significantly lower cosmogenic nuclide concentration than other mineral standards used for cosmogenic noble gas analysis and is therefore potentially useful for assessing the linearity of interlaboratory offsets across a wide range of concentrations. This paper reports 21 Ne analysis of 13 aliquots of CoQtz-N, interspersed with 14 aliquots of the commonly used CRONUS-A quartz standard, in three analytical sessions on two noble gas mass spectrometer systems. The excess 21 Ne concentration in CoQtz-N, normalized to the accepted value of 320 × 10 6 atoms g −1 for CRONUS-A, is 13.87 ± 0.24 × 10 6 atoms g −1 . Alternatively, the ratio of excess 21 Ne concentrations in CoQtz-N and CRONUS-A is 0.04330 ± 0.00077.

Balco, Greg [Lawrence Livermore National Laborator↗

Toxicity of pyrolysis products: Influence of experimental conditions - The MSTL/UT and NASA/JSC Procedures

Ten sample materials of various polymeric composition were evaluated for toxicity of pyrolysis products utilizing two significantly different experimental methods, the MSTL/UT and NASA/JSC Procedures. A comparison of the LD(50) values obtained by the two methods for these ten samples did not yield a significant correlation. However, when the samples were ranked in order of increasing toxicity by each method independently, a comparison of their rank order toxicity improved the correlation. Because of interlaboratory variations in pyrolysis/combustion test procedures, it is suggested a series of standard materials be adopted to facilitate interlaboratory comparisons of data on pyrolysis toxicity.

Lawrence, W. H.↗

Accuracy of trace element determinations in alternate fuels

A review of the techniques used at Lewis Research Center (LeRC) in trace metals analysis is presented, including the results of Atomic Absorption Spectrometry and DC Arc Emission Spectrometry of blank levels and recovery experiments for several metals. The design of an Interlaboratory Study conducted by LeRC is presented. Several factors were investigated, including: laboratory, analytical technique, fuel type, concentration, and ashing additive. Conclusions drawn from the statistical analysis will help direct research efforts toward those areas most responsible for the poor interlaboratory analytical results.

Greenbauer-Seng, L. A.↗

Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates, Phase II Results

The second phase of an analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted under the auspices of ASTM Interlaboratory Study 732. The interlaboratory study (ILS) had 10 participants with a broad range of expertise and experience, and experimental results from a surface crack tension test in 4142 steel plate loaded well into the elastic-plastic regime provided the basis for the study. The participants were asked to evaluate a surface crack tension test according to the version of the surface crack initiation toughness testing standard published at the time of the ILS, E2899-13. Data were provided to each participant that represent the fundamental information that would be provided by a mechanical test laboratory prior to evaluating the test result. Overall, the participant’s test analysis results were in good agreement and constructive feedback was received that has resulted in an improved published version of the standard E2899-15.

Allen, P. A.↗

Round-robin weathering test of various polymeric back-sheets for PV modules with different ultraviolet irradiation and sample temperatures

Durability assessment of materials exposed to natural weathering with expected service lifetimes of more than 20 years requires accelerated testing of the UV stability, especially for polymeric materials. Fraunhofer ISE organized an interlaboratory comparison for testing different back-sheets in various test laboratories using different UV sources. The five participating test laboratories used three different types of UV sources. The interaction of the UV radiation with the polymers used in PV modules is main subject of this round-robin. Laminates were produced by using solar glass and a suitable EVA encapsulant combined with 10 different back-sheets. The simultaneous usage of different optical filters allowed to investigate roughly the spectral sensitivity and the intensity impact. The degradation was followed by spectral reflectance and transmittance measurements and calculation of the yellowness index as degradation indicator. Clear differences in the degradation behavior of the different products were found.

14 SOLAR ENERGY↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Reference surface excess isotherms for carbon dioxide adsorption on ammonium ZSM-5 at various temperatures

Abstract This work is part of the effort at the Facility for Adsorbent Characterization and Testing (FACT lab) at the National Institute of Standards and Technology (NIST) to develop reference materials, reference data, and measurement best practices for adsorption metrology. High-pressure surface excess isotherms for CO 2 adsorption on NIST Reference Material 8852 (ammonium ZSM-5) at 15 °C, 25 °C, and 35 °C are reported, expanding on a FACT Lab-organized international interlaboratory study on this sorbent/sorbate pair at 20 °C. The range of temperatures of the present study is of interest for many CO 2 adsorption measurements and applications. Measurements were made using five different adsorption instruments, both manometric and gravimetric. Excellent agreement in the measured isotherms among the instruments was found. An empirical reference equation of the form, $${n}_{ex,ref}({P}_{eq})=\frac{c}{\{{1+\mathrm{exp}[\left(-\mathrm{ln}\left(P\right)+a\right)/b ]\}}^{b }} ,$$ n e x , r e f ( P eq ) = c { 1 + exp [ - ln P + a / b ] } b , [ n ex,ref is surface excess uptake (mmol/g); P eq is equilibrium pressure (MPa); P is ( P eq )/(1 MPa)]; a , b , c are constants] and the 95% uncertainty interval were determined for the isotherms at each of the temperatures. Lastly, the isosteric heat of adsorption is estimated from absolute isotherms derived from the surface excess reference data.

Nguyen, Huong Giang T. (ORCID:0000000210527565)↗

Exploring the use of thorium isotope compositions and concentrations as nuclear forensic signatures for uranium ore concentrates

This interlaboratory study measured thorium concentrations and isotope compositions in uranium ore concentrates from different geographical locations to examine whether thorium impurities may be useful forensic signatures for uranium ore concentrates found out of regulatory control. Measured 230 Th/ 232 Th in fifteen uranium ore concentrates record over three orders of magnitude of compositional variation. Results demonstrate that 230 Th/ 232 Th used in combination with U/Th ratios resulted in a unique signature for individual uranium ore concentrates from different processing locations. Data presented here suggest potential for 230 Th/ 232 Th and U/Th to be used as comparative signatures to investigate the provenance of seized uranium ore concentrates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗