CFD Validation with LDV Test Data for Payload/Fairing Internal Flow

Flowfield testing of a 1/5th scale model of a payload/fairing configuration, typical of an expendable launch vehicle, has been performed. Two-dimensional (planar) velocity measurements were carried out in four planes with the aid of Laser Doppler Velocimetry (LDV). Computational Fluid Dynamics (CFD) analysis results for the scale model flowfleld are compared with the test data. The CFD results are in general agreement with the test data. The ability of the CFD methodology in identifying the global flow features (including critical points such as vortex, saddle point, etc.) has been demonstrated. Practical problems and difficulties associated with the LDV method applied to the complex geometry under consideration have been summarized.

Kandula, max↗

NASA GSFC CCMC Recent Model Validation Activities

The Community Coordinated Modeling Center (CCMC) holds the largest assembly of state-of-the-art physics-based space weather models developed by the international space physics community. In addition to providing the community easy access to these modern space research models to support science research, its another primary goal is to test and validate models for transition from research to operations. In this presentation, we provide an overview of the space science models available at CCMC. Then we will focus on the community-wide model validation efforts led by CCMC in all domains of the Sun-Earth system and the internal validation efforts at CCMC to support space weather servicesjoperations provided its sibling organization - NASA GSFC Space Weather Center (http://swc.gsfc.nasa.gov). We will also discuss our efforts in operational model validation in collaboration with NOAA/SWPC.

Rastaetter, L.↗

Validation of a Thermo-Ablative Model of Elastomeric Internal Insulation Materials

In thermo-ablative material modeling, as in many fields of analysis, the quality of the existing models significantly exceeds that of the experimental data required for their validation. In an effort to narrow this gap, a laboratory-scale internal insulation test bed was developed that exposes insulation samples to realistic solid rocket motor (SRM) internal environments while being instrumented to record real-time rates of both model inputs (i.e., chamber pressure, total surface heat flux, and radiative heat flux) as well as model outputs (i.e., material decomposition depths (MDDs) and in-depth material temperatures). In this work, the measured SRM internal environment parameters were used in conjunction with equilibrium thermochemistry codes as inputs to one-dimensional thermo-ablative models of the PBINBR and CFEPDM insulation samples used in the lab-scale test firings. The computed MDD histories were then compared with those deduced from real-time X-ray radiography of the insulation samples, and the calculated in-depth temperatures were compared with those measured by embedded thermocouples. The results of this exercise emphasize the challenges of modeling and testing elastomeric materials in SRM environments while illuminating the path forward to improved fidelity.

Martin, Heath T.↗

Analog Exercise Hardware to Implement a High Intensity Exercise Program During Bed Rest

Background: In order to evaluate novel countermeasure protocols in a space flight analog prior to validation on the International Space Station (ISS), NASA's Human Research Program (HRP) is sponsoring a multi-investigator bedrest campaign that utilizes a combination of commercial and custom-made exercise training hardware to conduct daily resistive and aerobic exercise protocols. This paper will describe these pieces of hardware and how they are used to support current bedrest studies at NASA's Flight Analog Research Unit in Galveston, TX. Discussion: To implement candidate exercise countermeasure studies during extended bed rest studies the following analog hardware are being utilized: Stand alone Zero-Gravity Locomotion Simulator (sZLS) -- a custom built device by NASA, the sZLS allows bedrest subjects to remain supine as they run on a vertically-oriented treadmill (0-15 miles/hour). The treadmill includes a pneumatic subject loading device to provide variable body loading (0-100%) and a harness to keep the subject in contact with the motorized treadmill to provide a ground reaction force at their feet that is quantified by a Kistler Force Plate. Supine Cycle Ergometer -- a commercially available supine cycle ergometer (Lode, Groningen, Netherlands) is used for all cycle ergometer sessions. The ergometer has adjustable shoulder supports and handgrips to help stabilize the subject during exercise. Horizontal Squat Device (HSD) -- a custom built device by Quantum Fitness Corp (Stafford, TX), the HSD allows for squat exercises to be performed while lying in a supine position. The HSD can provide 0 to 600 pounds of force in selectable 5 lb increments, and allows hip translation in both the vertical and horizontal planes. Prone Leg Curl -- a commercially available prone leg curl machine (Cybex International Inc., Medway, MA) is used to complete leg curl exercises. Horizontal Leg Press -- a commercially available horizontal leg press (Quantum Fitness Corporation) is used for leg press and heel raise exercises. Minor modifications were made to the device including adding 200 lbs to the weight stack, raising the frame by 12 inches, making the footplate adjustable, and providing removable handles. Conclusion: A combination of novel and commercial exercise hardware are used to mimic the exercise hardware capabilities aboard the ISS, allowing scientific investigation of new countermeasure protocols in a space flight analog prior to flight validation

Loerch, Linda↗

Navier-Stokes simulation of inlet flow fields-experimental verification

The objectives were to develop a state-of-the-art numerical capability for the prediction of internal and external flow fields, validate the Navier-Stokes solution for internal flows, treat realistic diffuser inlet systems, and provide a technical base for inlet system design. Progress is reported in viewgraph form.

Chyu, Wei J.↗

Validation of ISCCP cloud detections

This paper describes the validation of the International Satellite Cloud Climatology project (ISCCP)cloud detections by verifying the accuracy of the infrared clear-sky radiances. Comparison of retrieved surface temperatures to other measurements shows that bias errors are less than 2 K and random errors are about 2 K for sea surface (monthly means at 280-km scales) and that bias errors are less than 2 K and random errors are about 4 K for land surfaces (3 hourly at 280-km scales). Bias errors over a few persistently cloudy locations are sometimes -(2-4) K and over winter sea ice may be about +2 K. Surface reflectances are confirmed to be within 3% of other measurements and models for ocean, except for sun glint geometries, and to be within 3%-5% for land surfaces. Sufficiently accurate validation data are not avilable for visible reflectances of sea ice and snow-covered land, but some tests of specific cases suggest that errors are approximately 10%. These errors in clear-sky radiances suggest uncertainties in the ISCCP cloud detections of about 10% with a small (3%-6%) negative bias over land. Some specific regions exhibit both larger rms uncertainties and somewhat larger biases in cloud amount approaching 10%. ISCCP cloud detections are more in error over the polar regions than anywhere else. Based on comparisons with an anlysis of radiances measured at other wavelengths, the ISCCP analysis appears to miss 15%-25% of the clouds in summer but only 5%-10% of the winter clouds.

Rossow, William B.↗

Global Precipitation Measurement (GPM) Mission: Overview and Status

The Global Precipitation Measurement (GPM) Mission is an international satellite mission specifically designed to unify and advance precipitation measurements from a constellation of research and operational microwave sensors. NASA and JAXA will deploy a Core Observatory in 2014 to serve as a reference satellite to unify precipitation measurements from the constellation of sensors. The GPM Core Observatory will carry a Ku/Ka-band Dual-frequency Precipitation Radar (DPR) and a conical-scanning multi-channel (10-183 GHz) GPM Microwave Radiometer (GMI). The DPR will be the first dual-frequency radar in space to provide not only measurements of 3-D precipitation structures but also quantitative information on microphysical properties of precipitating particles. The DPR and GMI measurements will together provide a database that relates vertical hydrometeor profiles to multi-frequency microwave radiances over a variety of environmental conditions across the globe. This combined database will be used as a common transfer standard for improving the accuracy and consistency of precipitation retrievals from all constellation radiometers. For global coverage, GPM relies on existing satellite programs and new mission opportunities from a consortium of partners through bilateral agreements with either NASA or JAXA. Each constellation member may have its unique scientific or operational objectives but contributes microwave observations to GPM for the generation and dissemination of unified global precipitation data products. In addition to the DPR and GMI on the Core Observatory, the baseline GPM constellation consists of the following sensors: (1) Special Sensor Microwave Imager/Sounder (SSMIS) instruments on the U.S. Defense Meteorological Satellite Program (DMSP) satellites, (2) the Advanced Microwave Scanning Radiometer-2 (AMSR-2) on the GCOM-W1 satellite of JAXA, (3) the Multi-Frequency Microwave Scanning Radiometer (MADRAS) and the multi-channel microwave humidity sounder (SAPHIR) on the French-Indian MeghaTropiques satellite, (4) the Microwave Humidity Sounder (MHS) on the National Oceanic and Atmospheric Administration (NOAA)-19, (5) MHS instruments on MetOp satellites launched by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT), (6) the Advanced Technology Microwave Sounder (ATMS) on the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP), and (7) ATMS instruments on the NOAA-NASA Joint Polar Satellite System (JPSS) satellites. Data from Chinese and Russian microwave radiometers may also become available through international collaboration under the auspices of the Committee on Earth Observation Satellites (CEOS) and Group on Earth Observations (GEO). The current generation of global rainfall products combines observations from a network of uncoordinated satellite missions using a variety of merging techniques. GPM will provide "next-generation" precipitation products characterized by: (1) more accurate instantaneous precipitation estimate (especially for light rain and cold-season solid precipitation), (2) intercalibrated microwave brightness temperatures from constellation radiometers within a consistent framework, and (3) unified precipitation retrievals from constellation radiometers using a common a priori hydrometeor database constrained by combined radar/radiometer measurements provided by the GPM Core Observatory. GPM is a science mission with integrated applications goals. GPM will provide a key measurement to improve understanding of global water cycle variability and freshwater availability in a changing climate. The DPR and GMI measurements will offer insights into 3-dimensional structures of hurricanes and midlatitude storms, microphysical properties of precipitating particles, and latent heat associated with precipitation processes. The GPM mission will also make data available in near realtime (within 3 hours of observations) forocietal applications ranging from position fixes of storm centers, numerical weather prediction, flood forecasting, freshwater management, landslide warning, crop prediction, to tracking of water-borne diseases. An overview of the GPM mission design, retrieval strategy, ground validation activities, and international science collaboration will be presented.

Hou, Arthur Y.↗

Laboratory analysis of techniques for remote sensing of estuarine parameters using laser excitation

The theoretical concepts underlying remote sensing of estuarine parameters using laser excitation are examined. The concepts are extended to include Mie scattering as a measure of the total suspended solids and to develop the water Raman signal as an internal standard. Experimental validation of the theory was performed using backscattered laser light from a laboratory tank to simulate a remote-sensing geometry. Artificially prepared sediments and biological cultures were employed to check specific aspects of the theory under controlled conditions. Natural samples gathered from a variety of water types were also analyzed in the tank to further enhance the simulation. The results indicate that it should be possible to remotely quantify total suspended solids, dissolved organics, attenuation coefficient, chlorophyll a, and phycoerythrin in estuarine water using laser excitation.

Exton, R. J.↗

Algorithm for Fluid Networks

Algorithm performs either transient integration or steady-state relaxation of network that represents internal fluid system. Valid for both single and two-phase flow of any fluid and includes both heat-transfer and work terms. General enough to simulate almost any flow system to almost any degree of detail desired. Encoded into computer program FLUINT, will work in conjunction with SINDA-85 program to enable analysis of pipelines; heating, ventilating, and cooling systems; and almost any other system that involves both fluid flow and heat transfer. Other possible extensions includes effects of flexibilities of containers, high-velocity flow, gravitation, acceleration, and opening and closing valves.

Cullimore, Brent A.↗

Analysis of Solar Spectral Irradiance Measurements from the SBUV/2-Series and the SSBUV Instruments

During this period of performance, 1 March 1997 - 31 August 1997, the NOAA-11 SBUV/2 solar spectral irradiance data set was validated using both internal and external assessments. Initial quality checking revealed minor problems with the data (e.g. residual goniometric errors, that were manifest as differences between the two scans acquired each day). The sources of these errors were determined and the errors were corrected. Time series were constructed for selected wavelengths and the solar irradiance changes measured by the instrument were compared to a Mg II proxy-based model of short- and long-term solar irradiance variations. This analysis suggested that errors due to residual, uncorrected long-term instrument drift have been reduced to less than 1-2% over the entire 5.5 year NOAA-11 data record. Detailed statistical analysis was performed. This analysis, which will be documented in a manuscript now in preparation, conclusively demonstrates the evolution of solar rotation periodicity and strength during solar cycle 22.

Cebula, Richard P.↗

EOS Reference Handbook 1999: A Guide to NASA's Earth Science Enterprise and the Earth Observing System

The content of this handbook includes Earth Science Enterprise; The Earth Observing System; EOS Data and Information System (EOSDIS); Data and Information Policy; Pathfinder Data Sets; Earth Science Information Partners and the Working Prototype-Federation; EOS Data Quality: Calibration and Validation; Education Programs; International Cooperation; Interagency Coordination; Mission Elements; EOS Instruments; EOS Interdisciplinary Science Investigations; and Points-of-Contact.

King, M. D.↗

What Good is Raman Water Vapor Lidar?

Raman lidar has been used to quantify water vapor in the atmosphere for various scientific studies including mesoscale meteorology and satellite validation. Now the international networks of NDACC and GRUAN have interest in using Raman water vapor lidar for detecting trends in atmospheric water vapor concentrations. What are the data needs for addressing these very different measurement challenges. We will review briefly the scientific needs for water vapor accuracy for each of these three applications and attempt to translate that into performance specifications for Raman lidar in an effort to address the question in the title of "What good is Raman water vapor Iidar."

Whitman, David↗

Bioculture System

The document is a 2 page fact sheet that describes the Bioculture system, how it may be used by researchers for life science research, how and when it will be installed and validated aboard the international space station.

bioculture↗

Representation of Tropical Storms by the Modern-Era Retrospective Analysis for Research and Applications Version 2

This study examines the veracity of the tropical cyclone (TC) statistics estimated from the Modern-Era Retrospective Analysis for Research and Applications, version 2 (MERRA-2) global atmospheric reanalysis, focusing on the climatological-mean genesis regions, tracks and their lifetime maximum intensity, as well as the interannual and intraseasonal variations in TC activity. The results are validated against the International Best Track Archive for Climate Stewardship (IBTrACS) data for 1980-2016. MERRA-2 represents the spatial distribution of the TC genesis location and the tracks realistically well over all main development regions (MDRs), but with notable discrepancies including too weak TC activity over the Arabian Sea and the South China Sea and too strong activity over the North Indian Ocean. Over the western North Pacific and the North Atlantic, MERRA-2 underestimates recurving TCs steered by background westerlies in the mid-latitudes and thereby exaggerates northwestward moving TCs, resulting in an overestimate of the landfall probability in East Asia and North America. Excessive development of TCs over the Bay of Bengal also tends to exaggerate the landfall probability in India. In spite of the discrepancies in the annual TC number, the seasonal variation of TC genesis is realistic in MERRA-2. MERRA-2 also captures the TC intensity relationship between the minimum pressure and the maximum surface wind speed at the mature stage, although the maximum intensity is weaker than in the observations. While MERRA-2 tends to reproduce the interannual variations of the observed TC number and the power dissipation index (PDI), the level of accuracy depends on the region. MERRA-2 describes the changes in the TC genesis region and tracks realistically according to the different phases of El Nino and the Southern Oscillation (ENSO) and the Madden-Julian Oscillation (MJO), although it is less realistic over the North Indian Ocean.

International Best Track Archive for Climate Stewa↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Preparation for an Earth Independent Medical Operations Demonstration using the Tempus ALS™ Medical Device

NASA’s exploration-class missions have severe resource constraints, long return trip durations, significant communication delays and limited resupply opportunities. Validation on the International Space Station (ISS) of medical devices that fit within Earth-Independent Medical Operations (EIMO) systems is a necessary preparation step. Key features of an EIMO medical system include: 1) technologies that support the prevention, diagnosis, and treatment of spaceflight medical events; 2) components that meet mass, volume, power and crew time/training constraints; 3) consideration of the medical skill level of the astronaut caregiver; 4) collection, storage and analysis of medical data within a central data architecture; and 5) incorporation of appropriate guidance and support tools that allow crew autonomy. The Human Research Program’s (HRP) Exploration Medical Capability (ExMC) Element and the Exploration Medical Integrated Product Team (XM-IPT) are planning an ISS technology demonstration to determine the feasibility of including a multifunctional medical device into an EIMO medical system. Demonstration Preparations: The Tempus ALS (Remote Diagnostic Technologies, Ltd., Philips Corp., Farnborough, UK) is a commercial-off-the-shelf medical device, with United States Food and Drug Administration clearance and is Conformité Européene marked in Europe. Several thousand units have been sold and are successfully operating in pre-hospital and in remote settings, such as by European Space Agency (ESA) flight surgeons and some of NASA’s commercial partners during post-flight medical operations. The Tempus ALS provides vital sign measurements such as blood pressure, electrocardiograms, heart rate, end tidal CO2, respiration rate, pulse oximetry and temperature. The device has ultrasound imaging and video laryngoscopy capabilities and has automatic or manual defibrillation modes for treating cardiac arrhythmias. It includes procedural guidance capabilities to assist in the collection of the vital sign measurements and it has various data transmission and report generation features. NASA’s HRP ExMC and XM-IPT are partnering with the ESA to demonstrate the Tempus ALS on ISS, with ESA manifesting the Tempus ALS and its accessories. ESA will compare performance of periodic health status exams and medical contingency drills performed nominally and with the Tempus ALS. NASA’s EIMO demonstration will include the use of Tempus ALS to diagnose a complaint of abdominal pain under increasingly independent circumstances. The caregiver must assess the present illness, collect vital sign measurements, and perform an abdominal ultrasound, under one of three communication situations, including real-time, with a several second delay and with a delay on the order of minutes. Expected Outcomes: Information will be gained about the feasibility, benefits, and challenges of using a multifunctional, all-in-one, medical device for medical diagnosis instead of separate devices with singular functionalities. Information will also be collected about performance differences as communication delays increase and available ground support decreases. Gaining this understanding will allow for further development of exploration medical system capabilities which takes the EIMO construct into consideration.

Beth Lewandowski↗

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combustor Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Combustor Noise↗

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combuster Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Turbomachinery Noise↗