Constant current sources consisting of sealed ionization chambers for calibrating electrometers
Direct current xenon-filled ceramic ionization chamber used as radiation detector in solar and astrophysical observations from rockets and satellites
Calculating integral generation multiplicity factor for neutron detector and ionization chamber to determine solar cosmic ray spectrum in high energy region
Mariner space probe ionization chamber and Geiger counter experiments on galactic radiation entering solar system
Simultaneous observations by identical ionization chambers aboard the satellites OGO-1 and OGO-3 are utilized to investigate spatial variations in particle intensity near and inside the magnetosphere during the solar cosmic ray events of September 1966. Cross-correlation of the absolute proton flux computed from the chamber rate during three solar particle events shows good agreement with the measurements by the IMP-F Solar Proton Monitor during the same events. The chamber has a dynamic range of over six orders of magnitude. Before launch it was calibrated in the laboratory with radiation dosages in the range 1 R/hr-6000 R/hr. The OGO-1 and OGO-3 chambers, which were normalized in the laboratory prior to the launch, are found to maintain their normalization within approximately equal to 1 per cent during their flight. The high sensitivity and absolute inter-comparability of the instruments allow small intensity differences to be detected and it is established that the observed differences can be explained by a magnetospheric screening effect when an anisotropic beam of particles is present in space. Evidence is presented to show that the screening is at times complete for a duration of as much as 110 min in the tail of the magnetosphere so that during this period the solar cosmic rays (E approximately equal to 15 MeV) have virtually no access to that region of the magnetosphere. Small intensity fluctuations of a temporal nature observed and found to be subjected to a damping effect inside the magnetosphere.
The design, construction, and characterization of the Multi-Sampling Ionization Chamber, MuSIC@Indiana, are described. This detector provides efficient and accurate measurement of the fusion cross-section at near-barrier energies. The response of the detector to low-intensity beams of 17,18 O, 19 F, 23 Na, 24,26 Mg, 27 Al, and 28 Si at E lab 50–60MeV was examined. MuSIC@Indiana was commissioned by measuring the 18 O+ 12 C fusion excitation function for 11 < E cm < 20 MeV using CH 4 gas. Here, a simple, effective analysis cleanly distinguishes proton capture and two-body scattering events from fusion on carbon. With MuSIC@Indiana, measurement of 15 points on the excitation function for a single incident beam energy is achieved. The resulting excitation function is shown to be in good agreement with literature data.
Samples of electron spectroscopy and ionization chamber data plots from OGO-1 and OGO-3
Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.
Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.
Potential advantages of the use of the relativistic rise of energy loss in gas-filled counters for cosmic ray energy measurement have been noted by Tueller et al. (1979) and Gregory and Parnell (1979). Gregory and Parnell have reported measurements on the relativistic rise for cosmic ray iron nuclei in parallel plate ionization chambers 8.4 cm thick filled with a xenon and methane mixture. The present investigation is concerned with the observed rise and ionization signal fluctuations for a sample of elements from carbon through iron in the cosmic rays. The results are compared with a calculation of the energy deposit within the ion chamber.
The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.
Electron spectra, pitch angle distributions and total ionization measured throughout radiation belts by satellite magnetic spectrometer and integrating ionization chamber
Measurement of radiation in space by two geiger-muller counters and argon filled ionization chamber on mariner ii space probe
The results of a new balloon borne cosmic ray detector flown from Palestine, TX in Sept., 1982 are discussed. The exposure of 62 square meter-ster-hr is sufficient to prove the concept of using gas ionization chambers as energy measuring devices in the relativistic rise region. The abundances, relative Fe-26, of the pure secondaries Cr-22 and Ti-24, the pure primary Ni26, and the mixed primary and secondary Ca-20 between 6 and 70GeV/amu were measured.
Construction of ISS will require more than 1000 hours of EVA. Outside of ISS during EVA, astronauts and cosmonauts are likely to be exposed to a large fluence of electrons and protons. Development of radiation protection guidelines requires the determination of the minimum energy of electrons and protons that penetrate the suits at various locations. Measurements of the water-equivalent thickness of both US. and Russian EVA suits were obtained by performing CT scans. Specific regions of interest of the suits were further evaluated using a differential range shift technique. This technique involved measuring thickness ionization curves for 6-MeV electron and 155-MeV proton beams with ionization chambers using a constant source-to-detector distance. The thicknesses were obtained by stacking polystyrene slabs immediately upstream of the detector. The thicknesses of the 50% ionizations relative to the maximum ionizations were determined. The detectors were then placed within the suit and the stack thickness adjusted until the 50% ionization was reestablished. The difference in thickness between the 50% thicknesses was then used with standard range-energy tables to determine the threshold energy for penetration. This report provides a detailed description of the experimental arrangement and results.
The paper describes a Cerenkov detector system designed to obtain abundances and energy spectra of cosmic ray nuclei above charge 12 and above 350 MeV/nucleon. The detector system consists of three pulse ionization chambers, a Lucite Cerenkov counter and a plastic scintillation-counter hodoscope. The data analysis follows from the standard dE/dx-C technique. It is shown that by using the relativistic ionization rise, the resolution and pulse height corresponding to charged particles of Beta ? 1 in Cerenkov detectors can be determined. Least-squares-fit procedures are used to obtain area and time variations of detector response from flight data and to extract elemental abundances from data with charge resolution of roughly 0.3 charge units.
The HEAO-3 experiment to study the heavy and ultraheavy nuclei in cosmic radiation is described. The array is double-ended and consists of three main elements. Two pressure chambers, filled with an argon-methane mixture at about 850 torr, each contain two x-y hodoscopes made of wires spaced 1 cm apart and three parallel plate ionization chambers. Between the pressure chambers is mounted a Cerenkov counter composed of two layers of Pilot 425 radiator looked at by eight photomultipliers. The instrument is designed to achieve a charge resolution of 0.3 charge units over the charge range 17-120, which requires a measurement accurate to 0.6 percent at Z = 100. Examination of selected data shows that the instrument has the intrinsic resolution needed.