Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Recent Corrections to Meteoroid Environment Models

The dynamical and physical characteristics of a meteoroid affects its behavior in the atmosphere and the damage it does to spacecraft surfaces. Accurate environment models must therefore correctly describe the speed, size, density, and direction of meteoroids. However, the measurement of dynamical characteristics such as speed is subject to observational biases, and physical properties such as size and density cannot be directly measured. De-biasing techniques and proxies are needed to overcome these challenges. In this presentation, we discuss several recent improvements to the derivation of the meteoroid velocity, directionality, and bulk density distributions. We derive our speed distribution from observations made by the Canadian Meteor Orbit Radar. These observations are de-biased using modern descriptions of the ionization efficiency and sharpened to remove the effects of measurement uncertainty, and the result is a meteoroid speed distribution that is skewed slower than in previous analyses. We also adopt a higher fidelity density distribution than that used by many older models. In our distribution, meteoroids with T(sub J) less than 2 are assigned to a low-density population, while those with T(sub J) greater than 2 have higher densities. This division and the distributions themselves are derived from the densities reported by Kikwaya et al. (2009, 2011). These changes have implications for the environment. For instance, helion and antihelion meteors have lower speeds and higher densities than apex and toroidal meteors. A slower speed distribution therefore corresponds to a sporadic environment that is more completely dominated by the helion and antihelion sources than in previous models. Finally, assigning these meteors high densities further increases their significance from a spacecraft damage perspective.

Moorhead, A. V.↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Results from an initial series of experiments and analyses performed at the Positron Imaging Centre (PIC) located at the University of Birmingham, UK, will be presented. Discussion will also cover preliminary, on-going, activities associated with assessing the utility of PET technology in zero-gravity propellant gauging, ionization efficiency characterization in electric propulsion devices, and broader industrial applications.

PET↗

LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

total ionizing dose (TID)↗

Variable fragmentation mass spectrometry using chemi-ionization

A description is given of experiments which provide a verification of three features of Penning ionization mass spectrometry. One of these features is related to the ability to simplify a molecular fragmentation pattern and to intensify the molecular ion peak. Another feature is concerned with the ability to identify uniquely geometric isomers which are indistinguishable using high-energy electron impact methods. The third feature involves the ability to identify components in a mixture, which cannot be discerned using electron impact or chemical ionization methods alone. The investigation shows that Penning ionization is an efficient soft ionization technique which can be used to simplify mass spectra of pure compounds as well as mixtures.

Laudenslager, J. B.↗

An efficient procedure for computing partial ionization of a gas in numerical fluid dynamics

A numerical procedure is described that allows efficient solution for the three nonlinear and implicit equations of state relating the equilibrium properties of a partially (and singly) ionized neutral gas. In the computation, the values for the intensive variables, that is pressure, temperature and ionization coefficient, are iteratively obtained with a given accuracy starting from assigned values for energy and volume per unit mass. Iterative computation is performed only when the value for the ionization coefficient lies within the lower and the upper bounds fixed by the required number of significant digits; otherwise the two explicit equations of state for nonionized or for fully ionized gases are employed.

Garribba, S.↗

Effects of silicate-graphite dust in H II regions

Interstellar dust that is present in H II regions will most likely absorb H-ionizing photons more efficiently than He-ionizing photons. Assuming a silicate-graphite dust composition, the effects of such selective absorption on the ionization structure of H, He, O, and N are investigated with emphasis on a blister geometry. Scattering by the dust grains is included in the generalized on-the-spot approximation. For a relatively soft radiation field of effective temperature about 35,000 K, the radiation hardening may cause the He(+) zone to be nearly coextensive with the H(+) zone, and the O(++) volume is strongly increased relative to the N(++) volume. The smaller grains (radii about 0.005 micron) contribute most to the selective absorption. We show that because of a cancellation of effects a simple analytical formula for the fraction of ionizing photons absorbed by the dust given by Petrosian, Silk, and Field is quite accurate in the case of silicate-graphite dust, even for blister regions.

Aannestad, Per A.↗

Chemical waste disposal in space by plasma discharge

An inductively coupled plasma discharge apparatus operating at 13.56 MHz and with electrical power up to 2.5 kW was constructed. The efficiency of this device to destroy various gases expected to be carried aboard the Space Station was tested. By expressing the efficiency of the device in terms of G-value (the number of molecules decomposed per 100 eV of energy absorbed), the results are compared with known efficiencies of ionizing radiation to destroy these same gases. In the case of ammonia, it was found that in the inductively coupled device, the destruction efficiency, G(-NH3) varied from 6.0 to 32.0 molecules/100 eV, depending on conditions. It was also found that capacitatively coupled discharges were less efficient in destroying NH2 than the inductively coupled discharge. In the case NH2 destruction, it was found that the G(-NH3) was a qualitative guide to the efficiencies of plasmas. The plasma device was also used to destroy nitrous oxide and methane. It is shown how the G-value for the destruction of any gas can be computed theoretically from a knowledge of the electron velocity distribution, the various electron molecule scattering cross sections, and the rate constants for the reactions of secondary species.

Baird, James K.↗

A comparison of solar wind and estimated solar system xenon abundances - A test for solid/gas fractionation in the solar nebula

The solar Xe elemental abundance is determined here using solar wind measurements from lunar ilmenites which are normalized to Si by spacecraft data. The results are compared with estimated abundances assuming no fractionation. When corrected for solar wind/photospheric fractionation, the Xe-130 abundance given by surface layer oxidation of ilmenite from solid 71501 exposed within the last 200 m.y. is 0.24 +/- 0.09 normalized to Si = 10 exp 6. This is indistinguishable from estimates made assuming no solid/gas fractionation. Results from breccia 79035 ilmenite exposed at least 1 Gyr ago indicate that the solar wind Xe flux may have been significantly higher relative to other noble gases, perhaps due to more efficient Xe ionization. If this is true, fluxes of C and S, which have first ionization potentials similar to Xe, should also be higher in the ancient solar wind from the same time period.

Wiens, Roger C.↗

Nanoflow Separation of Amino Acids for the Analysis of Cosmic Dust

The delivery of amino acids to the early Earth by interplanetary dust particles, comets, and carbonaceous meteorites could have been a significant source of the early Earth's prebiotic organic inventory. Amino acids are central to modern terrestrial biochemistry as major components of proteins and enzymes and were probably vital in the origin of life. A variety of amino acids have been detected in the CM carbonaceous meteorite Murchison, many of which are exceptionally rare in the terrestrial biosphere including a-aminoisobutyric acid (AIB) and isovaline. AIB has also been detected in a small percentage of Antarctic micrometeorite grains believed to be related to the CM meteorites We report on progress in optimizing a nanoflow liquid chromatography separation system with dual detection via laser-induced-fluorescence time of flight mass spectrometry (nLC-LIF/ToF-MS) for the analysis of o-phthaldialdehydelN-acetyl-L-cysteine (OPA/NAC) labeled amino acids in cosmic dust grains. The very low flow rates (<3 micro-L/min) of nLC over analytical LC (>0.1 ml/min) combined with <2 micron column bead sizes has the potential to produce efficient analyte ionizations andchromatograms with very sharp peaks; both increase sensitivity. The combination of the selectivity (only primary amines are derivatized), sensitivity (>4 orders of magnitude lower than traditional GC-MS techniques), and specificity (compounds identities are determined by both retention time and exact mass) makes this a compelling technique. However, the development of an analytical method to achieve separation of compounds as structurally similar as amino acid monomers and produce the sharp peaks required for maximum sensitivity is challenging.

Martin, M. P.↗

High-Sensitivity Ionization Trace-Species Detector

Features include high ion-extraction efficiency, compactness, and light weight. Improved version of previous ionization detector features in-line geometry that enables extraction of almost every ion from region of formation. Focusing electrodes arranged and shaped into compact system of space-charge-limited reversal electron optics and ion-extraction optics. Provides controllability of ionizing electron energies, greater efficiency of ionization, and nearly 100 percent ion-collection efficiency.

Bernius, Mark T.↗

Ionizing Organic Compound Based Nanocomposites for Efficient Gamma-Ray Sensor

Thin film and nanocrystalline materials of oxides have been very attractive choice as low cost option for gamma-ray detection and have shown great promise. Our studies on pure oxide films indicated that thickness and microstructure have pronounced effect on sensitivity. Since the interaction of gamma-ray with composites involves all three interaction processes; photoelectric effect, Compton scattering, and pair production, composites containing ionic organics have better chance for enhancing sensitivity. In the composites of ionizing organics oxidation effect of unusual oxides changes much faster and hence increases the sensitivity of radiation. In this study, we have used nickel oxide and titanium oxide in ionic organics to develop composite materials for low energy gamma-ray sensing. We prepared composites containing ethylene carbonate and evaluated the effect of commercial Cs-137 radiation source by studying current-voltage relationship at several frequencies. Radiated samples showed higher resistivity compared to as prepared composites.

Singh, N. B.↗

Separating Isotopes With Laser And Electron Beams

Need for second laser eliminated. In scheme for separation of isotopes, electrons of suitable kinetic energy ionize specific isotope excited by laser beam in magnetic field. Ionization by electron beams cheap and efficient in comparison to ionization by laser beams, and requires no special technical developments. Feasibility of new scheme demonstrated in selective ionization of Ba138, making possible separation of isotope from Ba isotopes of atomic weight 130, 132, 134, 135, 136, and 137.

Trajmar, Sandor↗

The absorption of energetic electrons by molecular hydrogen gas

The processes by which energetic electrons lose energy in a weakly ionized gas of molecular hydrogen are analyzed, and calculations are carried out taking into account the discrete nature of the excitation processes. The excitation, ionization, and heating efficiencies are computed for electrons with energies up to 100 eV absorbed in a gas with fractional ionizations up to 0.01, and the mean energy per pair of neutral hydrogen atoms is calculated.

Cravens, T. E.↗

The production efficiency of O/+//2P/ ions by auroral electron impact ionization

Observational data obtained from the Visible Airglow Experiment (VAE) on the Atmospheric Explorer D satellite is used to deduce the production efficiency of the excited 2P state of the O(+) ion in the electron impact ionization of O under auroral conditions. Measurements of the airglow intensity in the O(+)(2P-2D) transition band 7320-7330 A by the upward looking VAE photometer were compared with the intensity predicted on the basis of electron spectra measured at heights from 211 to 235 km within the emission. A production efficiency of 18% is obtained, which is close to theoretical predictions and supports the theoretical value of 40% for the production of the 2D state.

Rees, M. H.↗