Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Phonon-mediated quantum efficiency measurement in semiconductors

Accurate quantum efficiency measurement not only provides crucial information for the photovoltaic cell industry but also supports experiments aimed at directly detecting dark matter and elastic neutrino interactions. The dark matter direct searches paradigm has recently expanded to include particles with masses below 1,MeV/c2, where the expected signal in an electron–recoil interaction is approximately in the eV range, just above the energy gap for silicon and germanium. A robust calibration method for ionization signals in this lower energy region is essential. This paper presents a method for measuring quantum efficiency and yield (q/E) in semiconductors using phonon-mediated calorimetry. The Neganov–Trofimov–Luke phonon amplification method in low-temperature semiconductor crystals has been employed to indirectly measure ionization down to single-electron accuracy. Specifically, at zero bias, the phonon readout directly quantifies the total energy deposited within the detector, independent of the ionization yield. This eliminates a significant source of systematic uncertainty in quantum efficiency estimates associated with total energy uncertainty. The paper includes results from an updated ionization efficiency measurement in a germanium detector.

Physics↗

Efficiency of Room Air Cleaners for Removal of Bioaerosols From Ambient Air

The COVID-19 pandemic necessitated the evaluation of commercial air purification units to protect worker safety in indoor spaces. This project evaluated the efficacy of commercial off-the-shelf air purification systems that utilize electrostatic precipitation for the collection and removal of particulates (including bioaerosols) from ambient air. An aerosol mist containing Escherichia coli (E. coli) and bacteriophage surrogate virus, MS2, was produced using a nebulizer and delivered to the front intake of the commercial system with the ionizer ON and OFF. Removal efficiency was evaluated by colony/plaque formation assays using a small agar plate (60 X 15 mm) to passively collect E. coli and MS2 exhausting from the electrostatic precipitation cell. The system was determined to remove 98-99% of the microorganism introduced to the system. Testing was performed with all pre- and post-electrostatic cell filters removed so further removal is anticipated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Module-Level Solutions For Degradation by Ionization Damage

After years of improving module efficiency while targeting mean degradation rates of 0.5 to 0.6 %/y for crystalline silicon technology, there is much evidence that the degradation rates are now increasing significantly. Contributing factors include:Radiation damage (UV-Light Induced Degradation): Trina solar: -4.5%/y degradation rate in Singapore, DOE National Laboratory Regional Test Centers showed degradation of -1% < r < -2%/y in crystalline silicon modules, Jinko Solar: -4% < r < -7% efficiency loss from 540 MJ/m-2 of UV-A light, ISFH: 15% relative power loss during of 1.8 GJ/m-2 UV exposure, attributed to H+. Electrical bias from positive system voltage (e.g., +1000 V, +1500 V) can drive ions and metallization through the encapsulation, NREL: Ion transport can affect the cell passivation, resulting in power loss of 5% to 40% in p-PERC+ (bifacial), NREL: Damage at cell rear with up to 17% power at cell fronts in n-PERT modules. Delamination can also occur due to cell surface reactions driven by light and bias.

module efficiency↗

Cu-, Co-, and Zn-Based Metal–Organic Framework-Derived Nanoporous Ion Emitters for Picogram Level Analysis of Actinides

Thermal ionization mass spectrometry (TIMS) is often regarded as the preferred technique for trace-level isotopic analysis of actinides owing to its high sensitivity and absence of carry-over effects. However, actinide sample utilization efficiency (SUE) is typically low (<0.05%) without the use of activators or specialized loading approaches which can yield SUEs of >5%. To this effect, we investigate a series of metal–organic framework (MOF)-based nanoporous ion emitters (nano-PIEs) that show enhanced ionization of actinides when used in TIMS loading. We study the impact of physical and chemical properties of MOFs on TIMS SUEs using two families of MOFs that can be synthesized under similar reaction conditions. The structural and chemical properties of these MOFs can be systematically modified one at a time while keeping other features the same. This allows us to strategically investigate their impact on SUEs. The first family of MOFs considered in this study is Zeolitic Imidazole Frameworks (ZIFs) which are made using 2 methyl-imidazole as an organic linker with zinc (ZIF-8) and cobalt (ZIF-67) as metal centers. Additionally, the effect of morphology was also studied using Zn-based ZIF-L with a 2-dimensional structure. The second family of MOFs was synthesized using benzene-1,3,5-tricarboxylate (BTC) with copper (Cu-BTC) and zinc (Zn-BTC) as the metal center. Among the MOFs tested, Cu-BTC showed the highest SUE with an average SUE of 0.27 ± 0.15%, followed closely by Zn-BTC (0.24 ± 0.10%), ZIF-8 (0.17 ± 0.10%), and trailed by the other MOFs. When the MOFs were pyrolyzed in N 2 before loading, an apparent increase in the SUE was observed with ZIF-8 and Cu-BTC showing average SUEs of 0.25 ± 0.08% and 0.34 ± 0.13%, respectively, with the highest measured SUE of 0.53% for pyrolyzed Cu-BTC. In conclusion, this observed increase in SUE by up to an order of magnitude compared to bare filaments demonstrates the efficacy and potential of MOF-derived nano-PIEs for TIMS application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bright and durable scintillation from colloidal quantum shells

Abstract Efficient, fast, and robust scintillators for ionizing radiation detection are crucial in various fields, including medical diagnostics, defense, and particle physics. However, traditional scintillator technologies face challenges in simultaneously achieving optimal performance and high-speed operation. Herein we introduce colloidal quantum shell heterostructures as X-ray and electron scintillators, combining efficiency, speed, and durability. Quantum shells exhibit light yields up to 70,000 photons MeV −1 at room temperature, enabled by their high multiexciton radiative efficiency thanks to long Auger-Meitner lifetimes (>10 ns). Radioluminescence is fast, with lifetimes of 2.5 ns and sub-100 ps rise times. Additionally, quantum shells do not exhibit afterglow and maintain stable scintillation even under high X-ray doses (>10 9 Gy). Furthermore, we showcase quantum shells for X-ray imaging achieving a spatial resolution as high as 28 line pairs per millimeter. Overall, efficient, fast, and durable scintillation make quantum shells appealing in applications ranging from ultrafast radiation detection to high-resolution imaging.

47 OTHER INSTRUMENTATION↗

Probing vibronic coherence in charge migration in molecules using strong-field sequential double ionization

We propose a scheme for probing vibronic coherence in charge migration in molecules utilizing strong-field sequential double ionization. To demonstrate the feasibility of this approach, we perform full simulations of a pump-probe scheme employing few-cycle intense infrared pulses for N 2 and O 2 . We predict that the vibronic coherence between the pumped states will be directly imprinted in experimental observables such as kinetic energy release spectra and branching ratios of the dissociative dications. Our simulations are based on the recently developed density matrix approach for sequential double ionization model, which is capable of efficiently accounting for molecular orientations and enabling direct comparison with experimental results. Lastly, our findings strongly encourage the use of this probing scheme in future charge migration experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Trocylation of 3-quinuclidinol, a key marker for the chemical warfare agent 3-quinuclidinyl benzilate, for its enhanced detection at low levels in complex soil matrices by electron ionization gas chromatography–mass spectrometry

Detection of 3-quinuclidinol (3Q), a marker for the chemical warfare agent 3-quinuclidinyl benzilate, is very difficult by gas chromatography–mass spectrometry (GC/MS), providing low, broad signals even when analyzed in isolated form. Therefore, a method that can convert 3Q into a substrate with enhanced detectability by GC/MS would be an important tool for its analysis. 2,2,2-Trichloroethoxycarbonyl chloride (TrocCl) was used in the derivatization of 3Q in three different soils of varying composition and total organic content (Virginia type A soil, Nebraska EPA standard soil and Ottawa sand) when present at a 10 μg g -1 concentration in each. A direct derivatization protocol and one involving the pre-extraction of the analyte were evaluated for their individual efficiencies and subsequent analysis using electron ionization GC/MS. The practical derivatization of 3Q, when present at low levels (10 μg g -1 ) in three different soil matrices, was found to be rapid (1 h) and to take place smoothly at ambient temperature (and as low as 4°C). The method detection limit was determined to be 30 ng mL -1 for the Virginia type A soil, 49 ng mL -1 for the Nebraska EPA standard soil and 72 ng mL -1 for the Ottawa sand sample. An expedient and practical derivatization method for 3Q, a chemical warfare degradation product difficult to detect by GC/MS, has been realized using trichloroethyl chloroformate. The reaction provides 3Q-Troc, a derivative with better detectability than 3Q by electron ionization GC/MS such as peak sharpness and a unique mass spectrum for its unambiguous identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulations and Experimental Verifications of an Algorithm for Radiation Source Mapping and Navigational Path Generation

Accurate and efficient mapping and localization of both ionizing and non-ionizing radiation sources are important across many different fields. As such, a versatile mapping and navigational path generation algorithm, which can be applied to any point source measurements that follow an inverse-square characteristic, was developed using non-linear least squares methods. Forty thousand simulations were performed on the algorithm, which located sources successfully in a 10 m × 10 m × 10 m three-dimensional space with a success rate of over 80% across different noise functions, given a proportional constant of 10 to 1,000. The algorithm was also verified experimentally with small-scale radioactive decontamination of a 70 cm × 70 cm surface and localization of a lost Wi-Fi router in a 70 m × 70 m open field. One hundred twenty-one measurements were taken from each experiment, which were then fed into the algorithm for navigation. For the radioactive 137Cs source, the estimated locations were within 7 cm × 7 cm of the answer in 79.3% of the scenarios, while the Wi-Fi router was located to within 7 m × 7 m in 57.9% of the tests. In general, the method requires much less information and data than a geographically comprehensive survey and thus shows a lot of potential for practical applications, such as lost source retrieval with unmanned aerial vehicles, small-scale decontamination, mapping undocumented Wi-Fi routers or radio towers, and radiation simulation with radio signals. Here, the different failure modes, desirable features, and potential improvements were also identified but remain as future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma assisted NH 3 /H 2 /air ignition in nanosecond discharges with non-equilibrium energy transfer

Ammonia (NH 3 ), with its high energy density and easiness to store and transport as a hydrogen carrier, has become a promising alternative green fuel. However, its adoption in power generation is hindered by challenges such as low burning velocity, slow low-temperature oxidation, high NO x emissions, and ignition difficulty. Here, this work computationally investigates the effects of non-equilibrium energy transfer by nanosecond discharges on NH 3 ignition and flame propagation in an NH 3 /H 2 /air flow at 700 K and 1 atm. The simulation results demonstrate that NH 3 /air mixtures require a large ignition energy due to their large critical ignition radius. It is shown that adding 30 % hydrogen significantly reduces the critical ignition radius and minimum ignition energy. Two-dimensional modeling further shows a non-monotonic dependence of ignition kernel volume on the applied voltage and reduced electric field. The optimum ignition enhancement occurs at 200 Td where the generation of electronically excited species and radicals including N 2 (B), O( 1 D) and OH becomes most efficient. Higher voltages divert electron energy toward ionization, which makes it less effective for NH 3 ignition. The study also identifies an optimal electrode gap size for a given pulse energy. Smaller gap sizes increase deposited energy density, raising temperature and radical concentrations. However, excessive reduction of the gap distance reduces flame propagation speed due to the flame stretch effect in rich mixtures with the effective Lewis number greater than unity. A nonlinear relationship between pulse repetition frequency and ignition kernel volume is observed in a nanosecond pulsed high frequency discharge (NPHFD). An optimal frequency range of 200 kHz to 2 MHz is found when two pulses are used. In addition, an optimal number of pulses exists for each pulse repetition frequency, with higher frequencies requiring more pulses to maximize the overlap region. These findings provide critical insights on developing controlled plasma discharge techniques for efficient NH 3 ignition in reactive flows within internal combustion engines and gas turbines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new approach for measuring the carbon and oxygen content of atmospherically relevant compounds and mixtures

Abstract. Due to its complexity, gas- and particle-phase organic carbon in the atmosphere is often classified by its bulk physicochemical properties. However, there is a dearth of robust, moderate-cost approaches to measure the bulk chemical composition of organic carbon in the atmosphere. This is particularly true for the degree of oxygenation, which critically affects the properties and impacts of organic carbon but for which routine measurement approaches are lacking. This gap has limited the understanding of a wide range of atmospheric components, including particulate matter, the mass of which is monitored worldwide due to its health and environmental effects but the chemical characterization of which requires relatively high capital costs and complex operation by highly trained technical personnel. In this work, we demonstrate a new approach to estimate the mass of carbon and oxygen in analytes and mixtures that relies only on robust, moderate-cost detectors designed for use with gas chromatography. Organic compounds entering a flame ionization detector were found to be converted with approximately complete efficiency to CO2, which was analyzed downstream using an infrared detector to measure the mass of carbon analyzed. The ratio of the flame ionization detector (FID) signal generated to CO2 formed (FID∕CO2) was shown to be strongly correlated (R2=0.89) to the oxygen-to-carbon ratio (O∕C) of the analyte. Furthermore, simple mixtures of analytes behaved as the weighted average of their components, indicating that this correlation extends to mixtures. These properties were also observed to correlate well with the sensitivity of the FID estimated by structure activity relationships (quantified as the relative effective carbon number). The relationships between measured FID∕CO2, analyte O∕C, and FID sensitivity allow the estimation of one property from another with <15 % error for mixtures and <20 % error for most individual analytes. The approach opens the possibility of field-deployable, autonomous measurement of the carbon and oxygen content of particulate matter using time-tested, low-maintenance detectors, though such an application would require some additional testing on complex mixtures. With some instrumental modifications, similar measurements on gas-phase species may be feasible. Moreover, the potential expansion to additional gas chromatography detectors may provide concurrent measurement of other elements (e.g., sulfur, nitrogen).

42 ENGINEERING↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

Ionization waves in low-current dc discharges in noble gases obtained with a hybrid kinetic-fluid model

A hybrid kinetic-fluid model is used to study ionization waves (striations) in a low-current plasma column of dc discharges in noble gases. Coupled solutions of a kinetic equation for electrons, a drift-diffusion equation for ions, and a Poisson equation for the electric field are obtained to clarify the nature of plasma stratification in the positive column. A simplified two-level excitation-ionization model is used for the conditions when the nonlinear effects due to stepwise ionization, gas heating, and Coulomb interactions among electrons are negligible. It is confirmed that the nonlocal effects are responsible for the formation of moving striations in dc discharges at low plasma densities and low values of pR (the product of gas pressure and tube radius). Here, the calculated properties of self-excited waves of S–, P–, and R types in neon and S type in argon agree with available experimental data. The reason for helium plasma stability to stratification is clarified. It is shown that sustaining stratified plasma is more efficient than striation-free plasma when the ionization rate is a nonlinear function of the electric field. However, the nonlinear dependence of the ionization rate on the electric field is not required for plasma stratification. Striations of S–, P–, and R types in neon exist with minimal or no ionization enhancement. Effects of the column length and plasma density on the wave properties are demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of biexciton emission from single semiconductor nanoplatelets

Quasi-two-dimensional semiconductor nanoplatelets (NPLs) are intriguing systems for studying the influence of Auger recombination processes on the multiexciton emission efficiencies in the weak in-plane confinement regime. We investigate CdSe/CdS core/shell NPLs using cryogenic temperature single particle spectroscopy and observe bright biexciton emission at high excitation powers. The average binding energy of the biexcitons is determined to be 16.5 meV. The observed switching between the biexciton and trion states indicates charging-decharging dynamics of the NPLs mediated by the Auger ionization process. These findings are highly relevant for harvesting efficient biexciton emission for energy, lighting, and quantum applications.

36 MATERIALS SCIENCE↗