At least 55 records · Page 3

A Scalable PDC Placement Technique for Fast and Resilient Monitoring of Large Power Grids

The wide-area measurement system (WAMS) is a key enabler of real-time monitoring of power grids. The essential goals of WAMS design are fast and resilient data transfer from phasor measurement units (PMU) to phasor data concentrators (PDC). We propose a scalable two-stage PDC placement technique for minimizing the end-to-end delay while maintaining resiliency. In the prescreening stage, the plausible candidates of PDC configurations are identified based on a graph theory-based multi-median function (MMF). Here, in this article, a computationally efficient meta-heuristic algorithm is used to address scalability. In the candidate selection stage, two different algorithms, namely, Suurballe's and Dijkstra's, are employed to identify the best of those plausible PDC configurations as the final design. This technique not only minimizes the hop paths between PMUs and PDCs, but also ensures network resiliency against single PMU, PDC, or communication link failure by incorporating the roles of PMUs in power grid observability into routing policy. Simulation results on the IEEE 57-bus test power system and the 2000-bus test power system demonstrate the effectiveness and scalability of the proposed technique.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Efficient Algorithm for Locating and Sizing Series Compensation Devices in Large Transmission Grids: Solutions and Applications (PART II)

In a companion manuscript, we developed a novel optimization method for placement, sizing, and operation of Flexible Alternating Current Transmission System (FACTS) devices to relieve transmission network congestion. Specifically, we addressed FACTS that provide Series Compensation (SC) via modification of line inductance. In this manuscript, this heuristic algorithm and its solutions are explored on a number of test cases: a 30-bus test network and a realistically-sized model of the Polish grid (~2700 nodes and ~3300 lines). The results on the 30-bus network are used to study the general properties of the solutions including non-locality and sparsity. The Polish grid is used as a demonstration of the computational efficiency of the heuristics that leverages sequential linearization of power flow constraints and cutting plane methods that take advantage of the sparse nature of the SC placement solutions. Using these approaches, the algorithm is able to solve an instance of Polish grid in tens of seconds. We explore the utility of the algorithm by analyzing transmission networks congested by (a) uniform load growth, (b) multiple overloaded configurations, and (c) sequential generator retirements

25 ENERGY STORAGE↗

Method of Using Power Grid as Large Antenna for Geophysical Imaging

A high-voltage power transmission system is used as an extremely large antenna to extract spatiotemporal space, physical, and geological information from geomagnetically induced currents (GIC). A differential magnetometer method is used to measure GIC and involves acquiring line measurements from a first fluxgate magnetometer under a high-voltage transmission line, acquiring natural field measurements from a reference magnetometer nearby but not under the transmission line, subtracting the natural field measurements from the line measurements, and determining the GIC-related Biot-Savart field from the difference. NASA warning and alarm systems can be triggered based on determinations of GIC amplitude levels that exceed a set threshold value.

Pulkkinen, Antti A.↗

Benchmarking the PCMCI Causal Discovery Algorithm for Spatiotemporal Systems

Causal discovery algorithms construct hypothesized causal graphs that depict causal dependencies among variables in observational data. While powerful, the accuracy of these algorithms is highly sensitive to the underlying dynamics of the system in ways that have not been fully characterized in the literature. In this report, we benchmark the PCMCI causal discovery algorithm in its application to gridded spatiotemporal systems. Effectively computing grid-level causal graphs on large grids will enable analysis of the causal impacts of transient and mobile spatial phenomena in large systems, such as the Earth’s climate. We evaluate the performance of PCMCI with a set of structural causal models, using simulated spatial vector autoregressive processes in one- and two-dimensions. We develop computational and analytical tools for characterizing these processes and their associated causal graphs. Our findings suggest that direct application of PCMCI is not suitable for the analysis of dynamical spatiotemporal gridded systems, such as climatological data, without significant preprocessing and downscaling of the data. PCMCI requires unrealistic sample sizes to achieve acceptable performance on even modestly sized problems and suffers from a notable curse of dimensionality. This work suggests that, even under generous structural assumptions, significant additional algorithmic improvements are needed before causal discovery algorithms can be reliably applied to grid-level outputs of earth system models.

54 ENVIRONMENTAL SCIENCES↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗

Impact of Electric Vehicle Charging Station Reliability, Resilience, and Location on Electric Vehicle Adoption

While the majority of electric vehicle (EV) charging events in the United States occur at home, issues with public charging stations are consistently found to be a top reason that potential EV buyers do not purchase an EV, demonstrating that both EVSE reliability and availability impacts EV adoption. This report explores multiple parameters that impact EVSE reliability and deployment, which in turn impact EV sales. These include extreme weather, codes and standards, region (urban vs. rural), and grid network type. Grid reliability was not found to impact EV adoption. The relationships between EV station reliability, station resilience, grid resilience, and EV adoption are largely outside the scope of the National Renewable Energy Laboratory's (NREL's) Automotive Deployment Options Projection Tool (ADOPT) and other vehicle adoption models, so the methodology of this report is varied. Section 2 sets the baseline for infrastructure reliability, user satisfaction, and maintenance practices. Section 3 explores the ways that electric vehicle supply equipment (EVSE) reliability impacts the relationship between EVSE and EV adoption. Section 4 shows how geographical categories such as urban, rural, large grid, off-grid, or microgrid can be helpful in EVSE deployment strategies, as well as how the relationship between EVSE and EV adoption differs among these categories. Section 5 investigates the impacts of grid reliability and infrastructure resilience on EV adoption. Finally, Section 6 reverses the perspective to examine the impact that EVs and EVSE have on grid resilience and reliability. As recent funding initiatives result in an expansion of public chargers across the United States, as well as an increase in the uptime of existing chargers, EV adoption will likely grow.

33 ADVANCED PROPULSION SYSTEMS↗

A 3D agglomeration multigrid solver for the Reynolds-averaged Navier-Stokes equations on unstructured meshes

An agglomeration multigrid strategy is developed and implemented for the solution of three-dimensional steady viscous flows. The method enables convergence acceleration with minimal additional memory overheads, and is completely automated, in that it can deal with grids of arbitrary construction. The multigrid technique is validated by comparing the delivered convergence rates with those obtained by a previously developed overset-mesh multigrid approach, and by demonstrating grid independent convergence rates for aerodynamic problems on very large grids. Prospects for further increases in multigrid efficiency for high-Reynolds number viscous flows on highly stretched meshes are discussed.

Marvriplis, D. J.↗

INFLATING AND DEFLATING HOT JUPITERS: COUPLED TIDAL AND THERMAL EVOLUTION OF KNOWN TRANSITING PLANETS

We examine the radius evolution of close in giant planets with a planet evolution model that couples the orbital-tidal and thermal evolution. For 45 transiting systems, we compute a large grid of cooling/contraction paths forward in time, starting from a large phase space of initial semimajor axes and eccentricities. Given observational constraints at the current time for a given planet (semimajor axis, eccentricity, and system age), we find possible evolutionary paths that match these constraints, and compare the calculated radii to observations. We find that tidal evolution has two effects. First, planets start their evolution at larger semimajor axis, allowing them to contract more efficiently at earlier times. Second, tidal heating can significantly inflate the radius when the orbit is being circularized, but this effect on the radius is short-lived thereafter. Often circularization of the orbit is proceeded by a long period while the semimajor axis slowly decreases. Some systems with previously unexplained large radii that we can reproduce with our coupled model are HAT-P-7, HAT-P-9, WASP-10, and XO-4. This increases the number of planets for which we can match the radius from 24 (of 45) to as many as 35 for our standard case, but for some of these systems we are required to be viewing them at a special time around the era of current radius inflation. This is a concern for the viability of tidal inflation as a general mechanism to explain most inflated radii. Also, large initial eccentricities would have to be common. We also investigate the evolution of models that have a floor on the eccentricity, as may be due to a perturber. In this scenario, we match the extremely large radius of WASP-12b. This work may cast some doubt on our ability to accurately determine the interior heavy element enrichment of normal, noninflated close in planets, because of our dearth of knowledge about these planets' previous orbital-tidal histories. Finally, we find that the end state of most close in planetary systems is disruption of the planet as it moves ever closer to its parent star.

79 ASTRONOMY AND ASTROPHYSICS↗

Ray tracing of broadband bursty radio emissions from Uranus

To determine the source position of the broadband bursty emission, rays of X-mode emissin were traced from source positions along magnetic field lines with footprints that form a large grid centered approximately on the south magnetic pole of Uranus. For large wave normal angles, source regions different from those producing b-smooth emission were found. The emission observed prior to closest approach has a source along field lines that are distinct from those which generate emissions observed after closest approach.

Curran, D. B.↗

Nonreflecting boundary conditions for the complete unsteady transonic small-disturbance equation

Nonreflecting far-field boundary conditions that are consistent with the complete transonic small-disturbance (TSD) equations are derived. They are implemented in a new code for solving the complete TSD equation and are tested for a harmonically oscillating NACA 64A010 airfoil in transonic flow and for a flat-plate airfoil with a pulse in the angle of attack. Using the new boundary conditions on a relatively small grid, solutions for the airfoil that are obtained that agree with large-grid calculations, resulting in a 44 percent savings in computer time. Frequency responses for the flat plate show that most of the disturbances incident on the computational boundaries are absorbed by the boundary conditions.

Whitlow, W., Jr.↗

The GREATS H β + [O iii] luminosity function and galaxy properties at z ∼ 8: walking the way of JWST

ABSTRACT The James Webb Space Telescope will allow to spectroscopically study an unprecedented number of galaxies deep into the reionization era, notably by detecting [O iii]λλ4959, 5007, and H β nebular emission lines. To efficiently prepare such observations, we photometrically select a large sample of galaxies at z ∼ 8 and study their rest-frame optical emission lines. Combining data from the GOODS Re-ionization Era wide-Area Treasury from Spitzer (GREATS) survey and from HST we perform spectral energy distribution (SED) fitting, using synthetic SEDs from a large grid of photoionization models. The deep Spitzer/IRAC data combined with our models exploring a large parameter space enables to constrain the [O iii] + H β fluxes and equivalent widths for our sample, as well as the average physical properties of z ∼ 8 galaxies, such as the ionizing photon production efficiency with $\log (\xi _\mathrm{ion}/\mathrm{erg}^{-1}\mathrm{Hz})\ge 25.77$. We find a relatively tight correlation between the [O iii] + H β and UV luminosity, which we use to derive for the first time the [O iii]λλ4959, 5007 + H β luminosity function (LF) at z ∼ 8. The z ∼ 8 [O iii] + H β LF is higher at all luminosities compared to lower redshift, as opposed to the UV LF, due to an increase of the [O iii] + H β luminosity at a given UV luminosity from z ∼ 3 to z ∼ 8. Finally, using the [O iii] + H β LF, we make predictions for JWST/NIRSpec number counts of z ∼ 8 galaxies. We find that the current wide-area extragalactic legacy fields are too shallow to use JWST at maximal efficiency for z ∼ 8 spectroscopy even at 1 h depth and JWST pre-imaging to ≳30 mag will be required.

De Barros, S.↗

On the use of Darcy's law and invasion-percolation approaches for modeling large-scale geologic carbon sequestration

Most large-scale flow and transport simulations for geologic carbon sequestration (GCS) applications are carried out using simulators that solve flow equations arising from Darcy's law. Recently, the computational advantages of invasion-percolation (IP) modeling approaches have been presented. We show that both the Darcy's-law- and the gravity-capillary balance solved by IP approaches can be derived from the same multiphase continuum momentum equation. More specifically, Darcy's law arises from assuming creeping flow with no viscous momentum transfer to stationary solid grains, while it is assumed in the IP approach that gravity and capillarity are the dominant driving forces in a quasi-static two-phase (or more) system. There is a long history of use of Darcy's law for large-scale GCS simulation. However, simulations based on Darcy's law commonly include significant numerical dispersion as users employ large grid blocks to keep run times practical. In contrast, the computational simplicity of IP approaches allows large-scale models to honor fine-scale hydrostratigraphic details of the storage formation which makes these IP models suitable for analyzing the impact of small-scale heterogeneities on flow. However, the lack of time-dependence in the IP models is a significant disadvantage, while the ability of Darcy's law to simulate a range of flows from single-phase- and pressure-gradient-driven flows to buoyant multiphase gravity-capillary flow is a significant advantage. We believe on balance that Darcy's law simulations should be the preferred approach to large-scale GCS simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Experimental Investigation of Unsteady Surface Pressure on an Airfoil in Turbulence

Measurements of fluctuating surface pressure were made on a NACA 0015 airfoil immersed in grid generated turbulence. The airfoil model has a 2 ft chord and spans the 6 ft Virginia Tech Stability Wind Tunnel test section. Two grids were used to investigate the effects of turbulence length scale on the surface pressure response. A large grid which produced turbulence with an integral scale 13% of the chord and a smaller grid which produced turbulence with an integral scale 1.3% of the chord. Measurements were performed at angles of attack, alpha from 0 to 20 . An array of microphones mounted subsurface was used to measure the unsteady surface pressure. The goal of this measurement was to characterize the effects of angle of attack on the inviscid response. Lift spectra calculated from pressure measurements at each angle of attack revealed two distinct interaction regions; for omega(sub r) = omega b / U(sub infinity) is less than 10 a reduction in unsteady lift of up to 7 decibels (dB) occurs while an increase occurs for omega(sub r) is greater than 10 as the angle of attack is increased. The reduction in unsteady lift at low omega(sub r) with increasing angle of attack is a result that has never before been shown either experimentally or theoretically. The source of the reduction in lift spectral level appears to be closely related to the distortion of inflow turbulence based on analysis of surface pressure spanwise correlation length scales. Furthermore, while the distortion of the inflow appears to be critical in this experiment, this effect does not seem to be significant in larger integral scale (relative to the chord) flows based on the previous experimental work of McKeough suggesting the airfoils size relative to the inflow integral scale is critical in defining how the airfoil will respond under variation of angle of attack. A prediction scheme is developed that correctly accounts for the effects of distortion when the inflow integral scale is small relative to the airfoil chord. This scheme utilizes Rapid Distortion Theory to account for the distortion of the inflow with the distortion field modeled using a circular cylinder.

Mish, Patrick F.↗

Enhancing Scalability for FUN3D Rotorcraft Simulations with Yoga: an Overset Grid Assembler

FUN3D, an unstructured grid Navier-Stokes CFD code is capable of overset grid simu- lations, but does not have an internal method for assembling an overset grid system from a group of component grids. FUN3D currently relies on the third party codes Suggar++ and DiRTlib to perform domain assembly and provide intergrid connectivity for overset simulations. Rotorcraft simulations with moving, deforming blades require domain assembly and mesh deformation at each time step. For these simulations, the three primary drivers of computational cost for each time step are: deforming the mesh, performing domain assembly, and performing subiterations of the flow solver. FUN3D exhibits strong and weak scalability for the flow solver subiterations and the mesh deformation. However, FUN3D is currently hardwired directly to the serial version of Suggar++, which has a fixed cost for a given mesh system. Therefore, domain assembly begins to dominate the total cost of each time step as grid systems become larger. An integrated method for parallel domain assembly is presented that addresses scalability for large grid systems. Restructuring within FUN3D to accommodate integrated domain assembly is also discussed, which could enable use of the parallel Suggar++ library.

Cameron T Druyor↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗