Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Tunable Infrared Laser Absorption Spectroscopy of Aluminum Monoxide $A^2\Pi_i $–$X^2\Sigma^+$.

We report the details of an infrared, laser absorption diagnostic capable of quantifying aluminum monoxide temperature and column density at 100 kHz repetition rate. This novel technique employs a near infrared MEMS-VCSEL to measure rotationally resolved optical absorption spectra of aluminum monoxide $A^2\Pi_i$ - $X^2\Sigma^+$ from approximately 7400 –7900 cm -1 . Temperatures and column densities are extracted from model regressions to provide temporally resolved thermochemical information on aluminum oxidation reactions. The measurement capability is demonstrated by performing 100 kHz measurement in the plume of an exploding bridgewire with measured temperatures of 3450–3100 K and column densities of 1– 11 x 10 16 cm -2 . To the authors knowledge, this is the first use of the AlO $A^2\Pi_i$ - $X^2\Sigma^+$ transition to characterize aluminum combustion environments. Details regarding signal extraction and calibration of MEMS-VCSEL spectra are also included. Although unsuccessful, efforts to extract kinetic temperature and column density from simultaneously measured, atomic aluminum 2 P 3/2,1/2 - 2 S 1/2 transitions at 7618 cm -1 and 7602 cm -1 are also described.

47 OTHER INSTRUMENTATION↗

Laser absorption measurements of OH concentration and temperature in pulsed facilities

A laser absorption flow diagnostic application has been developed at the NASA Ames 16-inch Shock Tunnel for purposes of measuring the thermochemical state of OH in flow environments of interest. Research objectives include the investigation of high temperature, low pressure chemistry pertinent to scramjet combustors and high altitude flight. The system can be operated in either the fixed frequency mode or in the rapid wavelength scanning mode to measure species mole fraction and temperature. Emission diagnostics have been employed to determine shock tunnel flow quality and assist in the proper application of the diagnostic and its data interpretation. Rotational lines in the OH system were probed in the expanding facility nozzle flow, and time-resolved measurements of temperature and mole fraction are provided.

Cavolowsky, John A.↗

Miniaturized Laser Absorption Spectrometer for Combustion Calorimetry and Process Monitoring

A miniaturized tunable laser absorption spectrometer capable of measuring gas-phase concentrations of CO, CO2, and O2 has been developed for operation in spacecraft environments. As part of the Spacecraft Fire Safety Demonstration (Saffire) project, we previously demonstrated the Combustion Product Monitor (CPM) instrument to characterize pyrolysis of relevant test materials in low gravity aboard a transfer vehicle returning from low Earth orbit. Here, we adapted the CPM instrument design to achieve detection of CO, CO2, and O2 with improved minimum detection limits and dynamic range as well as reduced instrument size and power. The instrument can be operated in either an open or sealed configureation, allowing for ambient gas composition measuremnts or in-line monitoring of gas streams. By accurately monitoring CO, CO2, and O2 with broad pressure/temperature calibration and response time on the order of 1 s, the instrument can be used to characterize the dynamics of combustion reactions in a variety of environments.

Briggs, Ryan M.↗

The airborne Laser Absorption Spectrometer - A new instrument of remote measurement of atmospheric trace gases

The Laser Absorption Spectrometer is a portable instrument developed by JPL for remote measurement of trace gases from an aircraft platform. It contains two carbon dioxide lasers, two optical heterodyne receivers, appropriate optics to aim the lasers at the ground and detect the backscattered energy, and signal processing and recording electronics. Operating in the differential-absorption mode, it is possible to monitor one atmospheric gas at a time and record the data in real time. The system can presently measure ozone, ethylene, water vapor, and chlorofluoromethanes with high sensitivity. Airborne measurements were made in early 1977 from the NASA/JPL twin-engine Beechcraft and in May 1977 from the NASA Convair 990 during the ASSESS-II Shuttle Simulation Study. These flights resulted in measurements of ozone concentrations in the lower troposphere which were compared with ground-based values provided by the Air Pollution Control District. This paper describes the details of the instrument and results of the airborne measurements.

Shumate, M. S.↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) Aircraft Measurements of CO2

The Jet Propulsion Laboratory Carbon Dioxide Laser Absorption Spectrometer (CO2LAS) utilizes Integrated Path Differential Absorption (IPDA) at 2.05 microns to obtain CO2 column mixing ratios weighted heavily in the boundary layer. CO2LAS employs a coherent detection receiver and continuous-wave Th:Ho:YLF laser transmitters with output powers around 100 milliwatts. An offset frequency-locking scheme coupled to an absolute frequency reference enables the frequencies of the online and offline lasers to be held to within 200 kHz of desired values. We describe results from 2009 field campaigns when CO2LAS flew on the Twin Otter. We also describe spectroscopic studies aimed at uncovering potential biases in lidar CO2 retrievals at 2.05 microns.

Lidar↗

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

Laser absorption phenomena in flowing gas devices

A theoretical and experimental investigation is presented of inverse Bremsstrahlung absorption of CW CO2 laser radiation in flowing gases seeded with alkali metals. In order to motivate this development, some simple models are described of several space missions which could use laser powered rocket vehicles. Design considerations are given for a test call to be used with a welding laser, using a diamond window for admission of laser radiation at power levels in excess of 10 kW. A detailed analysis of absorption conditions in the test cell is included. The experimental apparatus and test setup are described and the results of experiments presented. Injection of alkali seedant and steady state absorption of the laser radiation were successfully demonstrated, but problems with the durability of the diamond windows at higher powers prevented operation of the test cell as an effective laser powered thruster.

Chapman, P. K.↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

Method and apparatus for enhancing laser absorption sensitivity

A simple optomechanical method and apparatus is described for substantially reducing the amplitude of unwanted multiple interference fringes which often limit the sensitivities of tunable laser absorption spectrometers. An exterior cavity is defined by partially transmissible surfaces such as a laser exit plate, a detector input, etc. That cavity is spoiled by placing an oscillating plate in the laser beam. For tunable diode laser spectroscopy in the mid-infrared region, a Brewster-plate spoiler allows the harmonic detection of absorptances of less than 10 to the -5 in a single laser scan. Improved operation is achieved without subtraction techniques, without complex laser frequency modulation, and without distortion of the molecular lineshape signal. The technique is applicable to tunable lasers operating from UV to IR wavelengths and in spectrometers which employ either short or long pathlengths, including the use of retroreflectors or multipass cells.

Webster, Christopher R.↗

Continuous wave laser absorption techniques for gasdynamic measurements in supersonic flows

Line-of-sight measurements of velocity, temperature, pressure, density, and mass flux were performed in a transient shock tube flow using three laser absorption schemes. All methods employed an intracavity-doubled ring dye laser tuned to an OH transition at 306 nm. In the first scheme, the gas was labeled by 193.3-nm excimer photolysis of H2O, and the passage of the generated OH was detected downstream. In the second method, the laser was tuned at a rate of 3 kHz over the R1(7) and R1(11) line pair, and absorption was simultaneously monitored at 90 and 60 deg with respect to the flow. Velocity was determined from the Doppler shift of the profiles and the temperature from the intensity ratio of the lines. Pressure was determined from both the magnitude of absorption and the collisional broadening. In the third method, the laser wavelength was fixed at a single frequency, and a continuous measurement of velocity and pressure was obtained using the signals from the two beam paths. All methods gave results which compare favorably to calculated values.

Davidson, David F.↗

Vibrational relaxation of the bending mode of shock-heated CO2 by laser-absorption measurements.

Study of the vibrational relaxation characteristics of shock-heated CO2 using a tuned CO2 laser absorption technique. Absorption-coefficient histories were obtained for a single rotational state in each of the -10 0- and -02 0- levels over the temperature range from 500 to 2000 K, and for 21 rotational states of the -10 0- level at 1000 K. These histories have been combined with translational-rotational temperature histories based on interferometer measurements to calculate vibrational relaxation times for the bending mode. The results verify the mutual equilibrium of the bending and symmetric-stretch modes due to Fermi resonance. The bending mode relaxation times are approximately 10% shorter than predicted from interferometer results using the ratio of specific heats. Furthermore, relaxation times based on measurements of different rotational states at 1000 K show a variation with quantum number J, indicating a possible rotational nonequilibrium during the vibration relaxation process.

Eckstrom, D. J.↗

Intracavity Dye-Laser Absorption Spectroscopy (IDLAS) for application to planetary molecules

Time-resolved, quasi-continuous wave, intracavity dye-laser absorption spectroscopy is applied to the investigation of absolute absorption coefficients for vibrational-rotational overtone bands of water at visible wavelengths. Emphasis is placed on critical factors affecting detection sensitivity and data analysis. Typical generation-time dependent absorption spectra are given.

Lang, Todd M.↗

Compact Multi-Channel Infrared Laser Absorption Spectrometer for Spacecraft Fire Safety Monitoring

We report on the design of a six-channel tunable laser absorption spectroscopy instrument for measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of fire events while also indicating what materials have been exposed to heating. Continued post-fire monitoring of these hazardous gases can also facilitate safe and effective cleanup. The sensor is a miniaturized version of a five-channel prototype that was previously validated in ground-based oxidative pyrolysis tests. Here, we describe absorption line selection and theoretical detection limits for a sensor with reduced absorption pathlengths for each detection channel, which allows for a substantial reduction in overall instrument footprint. Ultimately, the new instrument is designed to be used in fire safety tests conducted by NASA, where various materials will undergo oxidative pyrolysis in an unmanned spacecraft returning from low Earth orbit.

Briggs, Ryan M.↗

Fast-response, high-precision carbon monoxide sensor using a tunable diode laser absorption technique

A tunable diode laser instrument, denoted as DACOM (Differential Absorption CO Measurement), has been developed to meet the fast-response, high-precision CO measurement needs of the GTE (Global Tropospheric Experiment) program. Under the GTE program, DACOM participated in the three field missions of CITE 1 (Chemical Instrumentation Test and Evaluation 1), a project involving the intercomparison of trace gas measurement techniques. DACOM performance, including analyses of measurement error sources, is discussed for the ground-based mission at Wallops Island, VA (summer 1983), and two missions on the NASA CV-990 (fall 1983 and spring 1984). Examples of fast-response (about 1 s), high-precision (+ or - 1 part per billion by volume, + or - 1.5 percent of reading) airborne data are included to illustrate the capability of this instrument.

Sachse, Glen W.↗

Temperature estimation in a spatially inhomogeneous flame by diode laser absorption spectroscopy

A two-temperature (2T) model is proposed for estimating the temperature of a spatially inhomogeneous hot zone using single-beam diode laser absorption spectrometry. The proposed algorithm is based on fitting experimental absorption spectra by a linear combination of two database-simulated single-temperature spectra with different temperatures. The model efficiency is experimentally demonstrated when determining the temperature in different flame zones of a Wolfgard – Parker slot burner. The proposed 2T algorithm is used to find the maximum and minimum temperatures in different flame sections, which are compared with local temperatures in the same flame zones measured by the method of coherent anti-Stokes Raman scattering (CARS). It is shown that the maximum temperatures determined by the proposed 2T algorithm are in good agreement with CARS data in flame zones where high-temperature regions prevail. A good agreement between the minimum temperatures obtained by these two methods is also observed for predominantly cold zones. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ ozone data for comparison with laser absorption remote sensor: 1980 PEPE/NEROS program

Several sets of in situ ozone (O3) measurements were made by a NASA aircraft in support of the laser absorption spectrometer (LAS) remote sensor. These measurements were designed to provide comparative O3 data for the LAS sensor. The LAS, which was flown on a second aircraft, remotely measured the vertical burden of O3 from the aircraft to the surface. In situ results of the air quality (O3 and B sub scat) and meteorological (temperature and dewpoint) parameters for three correlative missions are presented. The aircraft flight plans, in situ concentration profiles and vertical burdens, and measurement errors are summarized.

Mcdougal, D. S.↗