Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Heat release surrogates for NH 3 /H 2 /N 2 –air premixed flames

The present study investigates the performance of NH, NH 2 , O-atom, and H-atom as heat release rate (HRR) surrogates for NH 3 /H 2 /N 2 –air premixed flame through simulations. The simulations are conducted across different pressures, reactant inlet temperatures, fuel blend compositions, and equivalence ratios. Cantera is used to simulate one-dimensional (1D) freely propagating flames to investigate the spatial correlations of the species with the HRR. PeleLMeX, a low-Mach direct numerical simulation (DNS) code with Adaptive Mesh Refinement (AMR), is used to simulate two-dimensional (2D) flame-vortex interactions to investigate the temporal correlations including stretch effects. Three different mechanisms (Jiang et al. 2020; Glarborg et al. 2018; Okafor et al. 2018) were considered in the 1D flame simulations, whereas only the Jiang mechanism was considered in the flame-vortex simulations. The HRR surrogate performance for the 2D flames is evaluated at two different locations: (1) the centerline and (2) the flame cusp. The cusp is defined as the region in the flame front with the greatest curvature and the centerline encounters the highest tangential strain rate. The 1D flame results suggest that, although there is not uniformly good spatial correlation for HRR across all flame conditions, NH is the best overall as a HRR surrogate for laminar flames. The 2D flame results, however, suggest that O-atom and H-atom have satisfactory temporal correlations at different conditions—the former for rich flames, the latter for high-pressure flames. Furthermore, these simulations provide guidance to experimental measurements of surrogate HRR markers in unsteady multi-dimensional flames using laser diagnostics to detect species such as NH, O-atom, and H-atom.

Ammonia↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

One dimensional temperature measurements by resonantly ionized photoemission thermometry of molecular nitrogen

This paper presents an extensive parameter study of a non-intrusive and non-seeded laser diagnostic method for measuring one dimensional (1D) rotational temperature of molecular nitrogen (N 2 ) at 165 - 450 K. Compared to previous efforts using molecular oxygen, here resonantly ionized and photoelectron induced fluorescence of molecular nitrogen for thermometry (N 2 RIPT) was demonstrated. The RIPT signal is generated by directly probing various rotational levels within the rovibrational absorption band of N 2 , corresponding to the 3-photon transition of N 2 ( X 1 Σ g + , v =0→ b 1 Π u , v ′ =6) near 285 nm, without involving collisional effects of molecular oxygen and nitrogen. The photoionized N 2 produces strong first negative band of N 2 + ( B 2 Σ u + − X 2 Σ g + ) near 390 nm, 420 nm, and 425 nm. Boltzmann analyses of various discrete fluorescence emission lines yield rotational temperatures of molecular nitrogen. By empirically choosing multiple rotational levels within the absorption band, non-scanning thermometry can be accurately achieved for molecular nitrogen. It is demonstrated that the N 2 RIPT technique can measure 1D temperature profile up to ∼5 cm in length within a pure N 2 environment. Multiple wavelengths are thoroughly analyzed and listed that are accurate for RIPT for various temperature ranges.

McCord, Walker (ORCID:0000000179747550)↗

Using Raman scattering to study reacting gas flow over a catalyst

l present a series of computational methods for analyzing and correcting Raman scattering from a reacting gas flow. My work focused on the laser diagnostic measurements of formaldehyde production over a silver catalyst, specifically the Raman spectroscopy component. This technique offers a non-intrusive, in situ way to measure the coupling between the gas phase and surface activity of a catalytic reaction at relevant industrial conditions. This report outlines the steps followed for correcting the non-idealities in the data due to both the detection optics and scattering mechanics. By implementing such refinement steps, l can generate an accurate 2D spatial map of the temperature profile, number densities for major species, and relative consumption of reactants throughout the reactor cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model Development for Multi-Component Fuel Vaporization and Flash Boiling

The objectives of this project are to improve the multi-component fuel droplet and film vaporization models used in internal combustion engine simulation, and to develop a comprehensive model to predict the characteristics of multi-component flash boiling spray. This work explores two approaches to fuel composition treatment for modeling multi-component fuel vaporization: one based on discretization and surrogates, and the other based on continuous thermodynamic distribution of fuel properties. The experimental data collected for model validation are done under three fuel form factors: droplet, spray, and thin film. The study on sprays also include experimentation under non-flash and flash boiling conditions, a phenomenon that enhances fuel vaporization. The main goals of this work are: Design and develop a multi-component fuel droplet and wall film vaporization model using both discrete and continuous thermodynamics methods. Design and develop an analytical model for multi-component flash boiling. Integrate the multi-component droplet and film model into multi-dimensional engine calculations to predict the fuel vaporization process under engine operation condition. Conduct multi-component droplet and fuel film vaporization experiments in a non-combusting chamber to verify the proposed vaporization models. Characterize flash boiling phenomena of multi-component fuel sprays by optical and laser diagnostic techniques. This report will detail the experimental setup and the numerical basis for developing a model to achieve the main goals listed above. Key features of observed multi-component fuel vaporization will be summarized at the end of each experimental sections, and corresponding model performance evaluation will be presented at the end of each model development section.

33 ADVANCED PROPULSION SYSTEMS↗

Tomographic imaging of atmospheric pressure plasma on complex surfaces

Many plasma types and behaviors such as streamer, arcs, cathode spots, anode spots, ionization waves, and magnetic field interactions create non-symmetric, fully 3D plasma structures. The plasma distribution in 3D space is heavily influenced by complex surfaces and the coupling interactions between plasma properties and the interfacing material properties. For example, ionization waves propagate in directions where ionization rates are highest, leading to complex configurations that are not fully understood or well characterized. Recent advances in laser diagnostics and models have been able to investigate well-controlled idealized plasmas in 2D fashion, but the complex structure in actual plasmas requires a technique than can provide a more complete 3D picture. However, 3D plasma diagnostics do not currently exist. To address this limitation, this activity will leverage available equipment to build a new tomographic optical imaging capability and advance the state-of-the-art in plasma diagnostics to investigate 3D phenomena on complex surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Catalyst Layer Design, Manufacturing and In-line Quality Control

In this project we successfully demonstrated the capabilities of the Reactive Spray Deposition Technology (RSDT) to fabricate large-scale CCMs for advanced PEMWEs that have one-order of magnitude lower PGM loading in their catalyst layers, and performance comparable with the commercial state-of-the-art CCMs. The RSDT is a unique methodology that combines the catalyst synthesis and CCM fabrication in one step and reduces dramatically the time for CCM manufacturing. As fabricated large-scale CCMs with geometric area of 680 cm2 demonstrated excellent activity and durability performance, and the novel duo-recombination layer design paves the way for solving the safety concerns related to PEMWEs. In addition, excellent activity and durability performance has been demonstrated with RSDT fabricated CCMs with thinner membranes and duo RL design. This is a novel approach for further performance improvement of the MEAs for PEMWEs that has been successfully demonstrated for the first time in this project. The integration of the in-situ laser diagnostics system along with the in-line optical quality control system within the RSDT that has been achieved and demonstrated in this project, is an example for possibility of designing and building advanced manufacturing technologies that can meet the requirements of the future manufacturing. Therefore, the RSDT offers a precise real-time monitoring and control of the particles size, composition, loading, porosity, thickness, and defects in the catalysts’ layers, which render this technology as the best candidate for manufacturing of cost effective CCMs for PEMWEs. By using RSDT we successfully met all project’s milestones, Go/No-Go decision, objectives, goals, and deliverables.

08 HYDROGEN↗

Pressure Gain, Stability, and Operability of Methane/Syngas Based RDEs Under Steady and Transient Conditions (Final Project Report)

The scope of this work addresses key issues associated with losses associated with the detonation wave and other processes internal to the RDE operation, as well as it develops modeling tools for the evaluation of these losses and exhaust emissions in RDEs. The main challenge in studying RDEs is that RDE performance is highly reliant on the specifics of the design so much so that simple/canonical systems alone cannot provide useful engineering information, but practical RDE designs are sufficiently complex and involve extreme operational environments that detailed access either experimentally (laser diagnostics, for instance) or computationally (direct numerical simulations) are as yet to become practical. To overcome this challenge, we have conducted a combined experimental/simulation/analytical study investigating key phenomena that control the characteristics of operation of RDEs. As a result, the study has developed tools and methods that can be used to evaluate performance and design approaches using reduced-physics models, with the assumptions validated using detailed simulations, and the model prediction tested using experimental observations. The specific objectives of the research were: (1) Develop and demonstrate a low-loss fully axial injection concept, taking advantage of stratification effects to alter the detonation structure and position the wave favorably within the combustor; (2) Obtain stability and operability characteristics of an RDE across operating conditions to aid in the development of operability and performance rules for the operations of other systems; and (3) Develop quantitative metrics for performance gain as well as quantitative description of the loss mechanisms through a combination of diagnostics development, reduced-order modeling, and detailed simulations. The work conducted here has made contribution on design of low-loss inlets that has broad application within the power generation industry for use with pressure gain combustion. The operability and stability of different designs, while focusing on axial air inlet designs, has been analyzed. The effect of nozzle and injection conditions was studied. Models and simulations of exhaust emissions, focusing on NOx emission has been developed and used to investigate how operation of the RDE affect NOx production using Lagrangian analysis of RDE simulations. This work has built on previous programs, with the goal of further understanding operation of RDEs and elevate the readiness of design consideration. In addition, a suite of diagnostic and modeling tools have been developed to obtain quantitative metrics on performance based on measurements, which can be readily transferred to other experimental configurations.

08 HYDROGEN↗

Flame Flashback Investigations in Hydrogen-Enriched Low Swirl Burner using High-Speed Hydroxyl Planar Laser-Induced Fluorescence

Hydrogen/ Hydrogen-rich flame is a potential strategy to reduce carbon emissions for the development of next-generation lean premixed combustors. However, the higher flashback propensity with hydrogen-enrichment owing to faster chemical kinetics is one of the key challenges in existing natural gas turbine combustors. In this study, the fundamentals of stabilized flame dynamics and flashback events in a premixed low swirl burner (LSB) configuration are visualized experimentally using nanosecond (ns)-based high-speed hydroxyl radical planar laser-induced fluorescence (OH-PLIF). The LSB has an optically accessible pre-mixing tube allowing laser diagnostic investigation of flashback events. The inlet conditions are varied systematically with respect to pre-mixer velocities, flame equivalence ratio (ϕ), and hydrogen content and OH-PLIF characterization is performed in stable flame at 20 kHz repetition rate. An increase in flashback propensity is observed with increasing ϕ, hydrogen content, and decreasing V via detailed investigation of flame lift-off length (L) above the burner rim. Flashback ϕ investigations show an expected linearly increasing trend with decreasing hydrogen content and increasing V for each swirler studied and the results agree well with detailed L investigations in stable flame configuration. The propagating flame anchored likely on the back side of the perforated plate within 30-40 ms of the entrance forming the distorted conical flame front.

Parajuli, Pradeep↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Multi-diagnostic characterization of laser-produced tin plasmas for EUV lithography

We present a comprehensive characterization of laser-produced tin (Sn) plasmas relevant to extreme ultraviolet (EUV) lithography using a multi-diagnostic suite integrated into the new experimental platform, “SparkLight.” Tin plasmas are generated by irradiating a continuously moving tin-coated wire with laser pulses (1064 nm, 10 ns, up to 5.7 × 10 10 W/cm 2 ) and probed via coherent Thomson scattering, laser interferometry, and EUV emission spectroscopy. Thomson scattering measurements reveal electron temperatures and densities that decay with distance from the target. Densities derived from Thomson scattering are cross-validated against laser interferometry, showing excellent agreement. Correlating the results of these laser diagnostics with spatially resolved EUV spectroscopy suggests that the bulk of useful EUV emission originates within 150 μm of the target and is generated under suboptimal plasma conditions. This work demonstrates a practical integrated approach for plasma characterization in EUV source development.

Musikhin, S. [Princeton Plasma Physics Laboratory ↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structured light approaches in laser-based plasma diagnostics

There is a growing demand for plasma diagnostics suitable for industrial plasma reactors employed in semiconductor nanofabrication, especially relevant to microelectronics and quantum information systems. Such reactors typically have limited optical access and pose considerable diagnostic challenges, including intense background emission, significant thermal loads, and contamination of optical viewports. In this study, we outline research into structured light techniques (laser beams with tailored spatial, temporal, or phase characteristics) that effectively overcome these issues using laser-induced fluorescence (LIF) as an example. The focus of presented diagnostics is on ion kinetics analysis within an industrial plasma source, although this approach is broadly applicable to other plasma systems and diagnostic contexts. We present a confocal LIF implementation using an axicon-generated Bessel annular beam, achieving spatial resolutions of approximately 5 mm at a focal distance of 300 mm, with potential improvements to about 1 mm. This approach matches conventional orthogonal LIF performance but requires only one optical port. Wavelength-modulation LIF employs nonlinear laser wavelength tuning to measure spectral line derivatives, suppressing background emission and enhancing details of spectral line shape. Additionally, we present new results on applying vortex beams (laser beams carrying orbital angular momentum, OAM) for LIF measurements in an industrial plasma device. These measurements enable simultaneous axial and tangential velocity determination using a single laser beam and have been tested with xenon ion transition. Initial quantification of results was performed. Together, these structured-light approaches provide robust, background-resilient, multi-dimensional diagnostics for complex plasma environments.

Romadanov, Ivan [Princeton Plasma Physics Laborato↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Combined microwave and laser Rayleigh scattering diagnostics for pin-to-pin nanosecond discharges

In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to the initial energy deposition of the nanosecond pulse, a variation in the local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data are extracted from MRS measurements. Furthermore, to recalibrate MRS measurements throughout the electron decay period, temporally resolved LRS measurements of the local gas density were performed over the event duration. The local gas density was calculated to be 30% of the ambient level during the later stages of electron decay, and it recovers at about 1 ms after discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally resolved intensified charge-coupled device imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5 × 1015 cm -3 and a decay rate of ~(0.1–0.35) × 10 7 s -1 . A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in the gas number density is expected due to energy deposition in the discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-Situ Laser-Induced-Desorption-Spectroscopy Diagnostic Deployment on the Linear Plasma Device CSDX

A calibrated laser induced desorption diagnostic (LIDS) concept is developed under this award for application to fusion relevant plasma materials interactions studies. Small areal amounts of hydrogenic release from a deuterium filled PMI target are measured and quantified when irradiated by a LID flash heat event on the target surface. Good success was demonstrated by this project with the PISCES-E rf plasma device at UCSD by fully quantified measurement and removal of D from W-D co-deposit layers in experiments. However, adapting the LIDS technique to D plasma exposed W targets in the linear plasma CSDX device, now labelled PISCES-Rf, was prone to several technical challenges ranging from target line of sight access, laser focusing, and loss of optical spectroscopic signal strength in the larger PISCES-Rf vacuum system. The results are summarized in this report.

08 HYDROGEN↗