Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser frequency noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Noise in Intense Electron Bunches (Final Technical Report)

The goal of this project is to investigate density fluctuations in electron bunches. Noise and density fluctuations in relativistic electron bunches, accelerated in a linac, are of critical importance to various Coherent Electron Cooling (CEC) concepts as well as to free-electron lasers (FELs). For CEC, the beam noise results in additional diffusion that counteracts cooling; and if this noise is not controlled at sufficiently low level, the noise heating effects can overcome cooling. There have been several proposals in the past to suppress the noise in the beam in the frequency range of interest in order to optimize the cooling effects. In SASE FELs a microwave instability starts from the initial noise in the beam and eventually leads to the beam microbunching yielding coherent radiation, and the initial noise in the FEL bandwidth plays a useful role. In seeded FELs, in contrast, such noise interferes with the seed signal, so that reducing noise at the initial seed wavelength would lower the seed laser power requirement. Our major goals were (1) to measure the electron beam density noise level in a 0.5 – 10 um wavelength range, (2) to predict the beam noise level in order to compare with the measurements, and (3) as a stretch goal, to find mechanisms that affect the beam noise to control its level in a predictable manner.

43 PARTICLE ACCELERATORS↗

Positive- and negative-frequency noise from an ensemble of two-level fluctuators

The analysis of charge noise based on the Bloch-Redfield treatment of an ensemble of dissipative two-level fluctuators generally results in a violation of the fluctuation-dissipation theorem. The standard Markov approximation (when applied to the two-level fluctuators coupled to a bath) can be identified as the main origin of this failure. The resulting decoherence rates only involve the bath response at the fluctuator frequency, and thus completely neglect the effects of frequency broadening. A systematic and computationally convenient way to overcome this issue is to employ the spectator-qubit method: by coupling an auxiliary qubit to the two-level fluctuator ensemble, an analytical approximation for S(ω) fully consistent with the fluctuation-dissipation theorem can be obtained. We discuss the resulting characteristics of the noise which exhibits distinct behavior over several frequency ranges, including a 1/f to 1/f2 crossover with a T3 temperature dependence of the crossover frequency.

2-dimensional systems↗

Effects of laser-annealing on fixed-frequency superconducting qubits

As superconducting quantum processors increase in complexity, techniques to overcome constraints on frequency crowding are needed. The recently developed method of laser-annealing provides an effective post-fabrication method to adjust the frequency of superconducting qubits. In this work, we present an automated laser-annealing apparatus based on conventional microscopy components and demonstrate preservation of highly coherent transmons. In addition, we perform noise spectroscopy to investigate the change in defect features, in particular, two-level system defects, after laser-annealing. Finally, we present a local heating model as well as demonstrate aging stability for laser-annealing on the wafer scale. Our work constitutes an important step toward both understanding the underlying physical mechanism and scaling up laser-annealing of superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-loss low thermo-optic coefficient Ta 2 O 5 on crystal quartz planar optical waveguides

Optical resonator-based frequency stabilization plays a critical role in ultra-low linewidth laser emission and precision sensing, atom clocks, and quantum applications. However, there has been limited success in translating traditional bench-top stabilization cavities to compact on-chip integrated waveguide structures that are compatible with photonic integration. The challenge lies in realizing waveguides that not only deliver low optical loss but also exhibit a low thermo-optic coefficient and frequency noise stability. Given the problematic sources of frequency noise within dielectrics, such as thermorefractive noise, resonators with small thermo-optic response are desirable for on-chip reference cavities. We report the first demonstration of a Ta 2 O 5 (tantala) waveguide core fabricated on a crystal quartz substrate lower cladding with TEOS-PECVD SiO 2 upper cladding. This waveguide offers significant advantages over other waveguides in terms of its low thermo-optic coefficient and reduced thermorefractive-related frequency noise. We describe the waveguide structure and key design parameters as well as fabrication considerations for processing tantala on quartz waveguides. We report a waveguide thermo-optic coefficient of -1.14 × 10 -6 RIU/K, a value that is over 6 times smaller in magnitude than that of SiO 2 -substrate tantala waveguides, with a propagation loss of 1.19 dB/cm at 1550 nm and <1.33 dB/cm across the 1525 nm–1610 nm wavelength range. Within a 1.6 mm radius ring resonator, we demonstrate a 2.54 × 10 5 intrinsic Q factor. With the potential for very low loss and the ability to control the thermal response, this waveguide platform takes a key step toward creating thermally stable integrated resonators for on-chip laser frequency stabilization and other applications.

42 ENGINEERING↗

Integrated optical frequency division for microwave and mmWave generation

Abstract The generation of ultra-low-noise microwave and mmWave in miniaturized, chip-based platforms can transform communication, radar and sensing systems 1–3 . Optical frequency division that leverages optical references and optical frequency combs has emerged as a powerful technique to generate microwaves with superior spectral purity than any other approaches 4–7 . Here we demonstrate a miniaturized optical frequency division system that can potentially transfer the approach to a complementary metal-oxide-semiconductor-compatible integrated photonic platform. Phase stability is provided by a large mode volume, planar-waveguide-based optical reference coil cavity 8,9 and is divided down from optical to mmWave frequency by using soliton microcombs generated in a waveguide-coupled microresonator 10–12 . Besides achieving record-low phase noise for integrated photonic mmWave oscillators, these devices can be heterogeneously integrated with semiconductor lasers, amplifiers and photodiodes, holding the potential of large-volume, low-cost manufacturing for fundamental and mass-market applications 13 .

Science & Technology - Other Topics↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Accurate determination of uranium isotope abundances by wavelength modulation spectroscopy in atomic beams

The design and demonstration of an optical analysis system based on wavelength modulation spectroscopy in an atomic beam for uranium isotope abundance determinations is presented. This system probes the uranium 5f 3 6d7s 2 ( 5 L 6 ) → 5f 2 6d 2 7s 2 ( 5 K 5 ) transition at 861.031 nm, which is considered to be the most suitable transition for uranium isotopic analysis. A new laser characterization strategy was developed for the conditions where optimum laser wavelength modulation depth was small compared to the free spectral range (FSR) of etalons. Two capabilities enabled the higher-precision determination of isotope abundances of atomic beams: (1) reduction of low-frequency additive noise, especially the noise caused by black-body radiation and (2) suppression of non-absorption transmission losses. The performance of this system was validated with uranium samples of various isotopic compositions. Further, by comparing the measurements using natural uranium samples between the direct absorption and the wavelength modulation approaches, a 21-fold decrease in uncertainty of the integrated absorbance and a 6.8-fold improvement in the 1-σ precision of the number density were achieved. In addition, by comparing the results using uranium oxide samples, a 6.1-fold decrease in the uncertainty of inferred isotope abundance was obtained. These results demonstrate that the 1f-normalized 2f wavelength modulation spectroscopy (WMS-2f/1f) technique enables higher-precision analysis of atomic beams.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electrothermoplasmonic Trapping and Dynamic Manipulation of Single Colloidal Nanodiamond

Low-power trapping of nanoscale objects can be achieved by using the enhanced fields near plasmonic nanoantennas. Unfortunately, in this approach the trap site is limited to the position of the plasmonic hotspots and continuous dynamic manipulation is not feasible. In this work, we report a low-frequency electrothermoplasmonic tweezer (LFET) that provides low-power, high-stability and continuous dynamic manipulation of a single nanodiamond. LFET harnesses the combined action of the laser illumination of a plasmonic nanopillar antenna array and low-frequency alternating current (ac) electric field to establish an electrohydrodynamic potential capable of the stable trapping and dynamic manipulation of single nanodiamonds. We experimentally demonstrate the fast transport, trapping, and dynamic manipulation of a single nanodiamond using a low-frequency ac field below 5 kHz and low-laser power of 1 mW. This nanotweezer platform for nanodiamond manipulation holds promise for the scalable assembly of single photon sources for quantum information processing and low noise quantum sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

On the determination of shocked surface velocities

Laser Doppler velocimetry is commonly fielded in shock physics experiments to diagnose the times of arrival, magnitudes, and durations of shock impulses as they arrive at shock loaded surfaces. However, in the presence of ejecta, the resulting frequency noise often obscures the surface and subsequent impulses at later times. In this context, we evaluate a dominant wave analysis technique applied to velocimetry data from explosively shocked Sn subjected to a second shockwave, on which ejecta are emitted subsequent to both the first and subsequent shockwave impulses. The analysis reveals surface velocities, the times of arrival of subsequent impulses, and their durations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Searching for Interstellar Quantum Communications

The modern search for extraterrestrial intelligence began with the seminal publications of Cocconi & Morrison and Schwartz & Townes, who proposed searching for narrowband signals in the radio spectrum and optical laser pulses. Over the last six decades, more than 100 dedicated search programs have targeted these wavelengths, all with null results. All of these campaigns searched for classical communications, that is, for a significant number of photons above a noise threshold, with the assumption of a pattern encoded in time and/or frequency space. I argue that future searches should also target quantum communications. They are preferred over classical communications with regard to security and information efficiency, and they would have escaped detection in all previous searches. The measurement of Fock state photons or squeezed light would indicate the artificiality of a signal. I show that quantum coherence is feasible over interstellar distances and explain for the first time how astronomers can search for quantum transmissions sent by ETI to Earth using commercially available telescopes and receiver equipment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment

To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relations between Shot Noise, Gain Bandwidth, and Saturation of Instabilities

There are numerous instabilities present in charged particle beams that undergo exponential growth and reach saturation. In various applications, such as free-electron lasers or micro-bunching light sources, achieving saturation is desirable. Conversely, there are applications where these instabilities are utilized as linear broad-band amplifiers for signals embedded in the charged beam. In the latter scenario, the saturation of an instability induces non-linear distortions in the imprinted signal, thereby limiting the useful range of such amplifiers. Accurate evaluation of these instabilities necessitates a complete and comprehensive modeling approach that includes shot noise within the beam. Unfortunately, such modeling is not always feasible or practical. In this paper, we introduce a methodology utilizing the frequency and bandwidth of the instability as key parameters. Through this, we derive an estimation for the range of linear instability growth. Our derivation is conducted in a model-independent manner, making it applicable to a broad spectrum of instabilities. To validate our approach, we employ established and thoroughly benchmarked simulations with a free electron laser (FEL) code as well as self-consistent 3-dimensional simulation of plasma-cascade instability using code SPACE.

43 PARTICLE ACCELERATORS↗

Dual-frequency-comb UV spectroscopy with one million resolved comb lines

We present high-resolution dual-comb spectroscopy across two broad UV spectral regions spanning 372–410 nm and 325–342 nm. This is achieved by generating sixth and seventh harmonics, respectively, from a low-noise 2.35 µm Cr:ZnS dual-comb laser system. The sixth harmonic band contains approximately 1,000,000 spectrally resolved comb lines, while the seventh harmonic band—around 550,000 comb lines. With the line spacing of 80 MHz, this corresponds to a resolving power of up to 10 million, offering remarkable spectral resolution.

Muraviev, Andrey↗

Spatially resolved fibre cavity ring down spectroscopy

Abstract This paper presents a fibre cavity ring down spectroscopy probed by Rayleigh scattering optical frequency domain reflectometry (OFDR), which provides spatial location of stimuli and improved signal to noise ratio for distributed sensing measurements. A section of optical fibre was integrated into an active fibre ring cavity with optical gain and interrogated by the OFDR system for 11 cycles with a single laser scan. Through the cavity ring down configuration, root-mean-squared (RMS) noise of distributed temperature and strain measurements was reduced to 6.9 mK and less than 0.1 με, respectively for 1-cm spatially resolved measurements. Our work shows that the active fibre cavity configuration can be combined with distributed fibre sensing schemes to achieve both high spatial resolution and high sensitivity measurements.

97 MATHEMATICS AND COMPUTING↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Will LISA Detect Harmonic Gravitational Waves from Galactic Cosmic String Loops?

Rapid advancement in the observation of cosmic strings has been made in recent years placing increasingly stringent constraints on their properties, with $G\mu\lesssim 10^{-11}$ from Pulsar Timing Array (PTA). Cosmic string loops with low string tension clump in the Galaxy due to slow loop decay and low gravitational recoil, resulting in great enhancement to loop abundance in the Galaxy. With an average separation of down to just a fraction of a kpc, and the total power of gravitational wave (GW) emission dominated by harmonic modes spanning a wide angular scale, resolved loops located in proximity are powerful, persistent, and highly monochromatic sources of GW with a harmonic signature not replicated by any other sources, making them prime targets for direct detection by the upcoming Laser Interferometer Space Antenna (LISA), whose frequency range is well-matched. Unlike detection of bursts where the detection rate scales with loop abundance, the detection rate for harmonic signal is the result of a complex interplay between the strength of GW emission, loop abundance, and other sources of noise, and is most suitably studied through numerical simulations. We develop a robust and flexible framework for simulating loops in the Galaxy for predicting direct detection of harmonic signal from resolved loops by LISA. Our simulation reveals that the most accessible region in the parameter space consists of large loops $\alpha=0.1$ with low tension $10^{-21}\lesssim G\mu\lesssim 10^{-19}$. Direct detection of field theory cosmic strings is unlikely, with the detection probability $p_{\mathrm{det}}\lesssim 2\%$ for a 1-year mission. An extension suggests that direct detection of cosmic superstrings with a low intercommutation probability is very promising. Searching for harmonic GW signal from resolved loops through LISA observations will potentially place physical constraints on string theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Compensation of residual amplitude modulation fluctuations in an optoelectronic system for laser radiation frequency stabilisation

Fluctuations of residual amplitude modulation in a scheme of laser frequency stabilisation by a Fabry – Perot cavity reduce the frequency stability of the laser systems intended for interrogating clock transitions of atoms and ions. The dependences of the residual amplitude modulation on a temperature of the waveguide-based electro-optical modulator used for modulating the radiation phase and on polarisation of the radiation are measured. The parameters are found, at which the influence of the residual amplitude modulation on the frequency stability is minimal. A system for active compensation is created, which reduces the contribution of fluctuations of residual amplitude modulation to the instability down to 2.1 × 10{sup −16}, which makes it possible to reach the thermal noise limit of a silicon cryogenic cavity. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗