Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser induced breakdown spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiative transition probabilities of neutral and singly ionized rare earth elements (La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) estimated by laser-induced breakdown spectroscopy

Rare earth elements (REEs) are essential to society given their prevalence in many modern technologies. Quantitative elemental analysis of REEs is therefore a critical capability. Calibration free–laser-induced breakdown spectroscopy (CF-LIBS) is a rapidly maturing and promising approach to quantitative elemental analysis with many attractive qualities. The application of CF-LIBS to analyzing samples containing the REEs is hindered by a lack of fundamental data, specifically transition probabilities (TPs). As such, this study seeks to help address this knowledge deficiency by reporting 967 previously unreported TPs for 13 REEs (lanthanum, cerium, praseodymium, neodymium, samarium, gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, and lutetium). The method developed in this study to estimate the TPs requires small amounts of material (a few nanograms) compared with other approaches (~ milligrams), uses non-specialized equipment, and does not involve complicated sample preparations.

(LIBS)↗

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U–238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of -17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. In conclusion, the analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.

47 OTHER INSTRUMENTATION↗

Enhancing analytical merits of laser-induced breakdown spectroscopy of hydrogen isotopes using an orthogonal double-pulsing scheme

Accurate detection and quantification of hydrogen isotopes in solid materials are vital for diverse applications, including fusion energy, hydrogen storage, and tritium production. Laser-induced breakdown spectroscopy (LIBS) is a well established, rapid, standoff method for this purpose, but it faces challenges related to the analytical merits required for isotopic analyses. In this study, we enhance the analytical and detection capabilities of traditional single-pulse LIBS by implementing an orthogonal double pulsing approach, focusing on the analysis of a range of 2 H concentrations in Zircaloy-4 substrates (acting as a proxy for 3 H). The double-pulse experiments employed an orthogonal re-heating configuration with two nanosecond Nd:YAG lasers. We systematically evaluated critical parameters affecting the signal intensity in double-pulse LIBS, including interpulse delay, ambient gas pressure, and heating laser energy. Finally, our results demonstrate that employing an orthogonal double-pulse scheme significantly enhances 2 H α emission while minimizing line broadening and self-absorption, ultimately improving the technique’s analytical capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

ABSTRACT Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. Our results demonstrate a distinct correlation between fungal species and their elemental profile, regardless of the substrate media, as the same strains shared a similar uptake of carbon, zinc, phosphorus, manganese, and magnesium, which could play a vital role in their survival and propagation. Independently, each fungal species exhibited a unique elemental profile. This work demonstrates a unique and valuable approach to rapidly phenotype fungi through optical spectroscopy, and this approach can be critical in understanding these fungi's behavior and interactions with the environment. IMPORTANCE Historically, ionomics, the elemental profiling of an organism or materials, has been used to understand the elemental composition in waste materials to identify and recycle heavy metals or rare earth elements, identify the soil composition in space exploration on the moon or Mars, or understand human disorders or disease. To our knowledge, ionomic profiling of microbes, particularly fungi, has not been investigated to answer applied and fundamental biological questions. The reason is that current ionomic analytical techniques can be laborious in sample preparation, fail to measure all potential elements accurately, are cost-prohibitive, or provide inconsistent results across replications. In our previous efforts, we explored whether laser-induced breakdown spectroscopy (LIBS) could be used in determining the elemental profiles of poplar tissue, which was successful. In this proof-of-concept endeavor, we undertook a transdisciplinary effort between applied and fundamental mycology and elemental analytical techniques to address the biological question of how LIBS can used for fungi grown axenically in a nutrient-rich and nutrient-poor environment.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of Off-Gassed Products From Molten Salts Using Laser-Induced Breakdown Spectroscopy

The detection of off-gassed sodium from molten sodium nitrate (NaNO 3 ) at temperatures between 330 °C and 505 °C and off-gassed calcium from molten lithium chloride–potassium chloride eutectic (LKE) mixtures at 510 °C with laser-induced breakdown spectroscopy (LIBS) was demonstrated. NaNO 3 and LKE samples were melted in a custom-built crucible that promoted the generation of off-gassed products from the molten sample. The off-gassed products were analyzed with a LIBS system designed to probe the high-temperature environment. Na D emission lines, Na(I)588.99 nm and Na(I) 589.59 nm, were detected from the NaNO 3 samples after reaching a temperature threshold, which indicated the occurrence of phase change. In LKE mixtures, the detection of Ca impurities at a concentration of 78 mg/kg was possible using the emission lines Ca(II) 393.66 nm and Ca(II) 395.85 nm. Furthermore, this work demonstrates the real-time monitoring capabilities of LIBS in high-temperature environments that simulate the conditions of molten salt reactors.

42 ENGINEERING↗

Quantification of Rare Earth Elements in the Parts Per Million Range: A Novel Approach in the Application of Laser-Induced Breakdown Spectroscopy

This work extends a previous percentage level concentration study of the optical emission spectra for six rare earth elements, europium (Eu), gadolinium (Gd), lanthanum (La), praseodymium (Pr), neodymium (Nd), and samarium (Sm), along with the transition metal, yttrium (Y) using laser-induced breakdown spectroscopy (LIBS). The concentration of these six rare earth elements and yttrium has been attempted for the first time systematically down to parts per million (ppm) concentration levels ranging from 30 to 300 ppm. In this study, the authors have developed multivariate models for each element capable of predicting concentration with acceptable to excellent levels of accuracy. Additionally, partial least squares regression coefficients were used to identify key spectral features able to be used in this lower concentration regime. This study has demonstrated that it is conceivable to quantify the six rare earth elements along with yttrium at low concentrations in the parts per million levels.

59 BASIC BIOLOGICAL SCIENCES↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Establishing Isotopic Measurement Capabilities using Laser-Induced Breakdown Spectroscopy for the Molten Salt Reactor Campaign

Proof-of-principle H isotope ratios of aqueous aerosol systems and liquid droplets on filter paper have been measured using laser-induced breakdown spectroscopy (LIBS) with root mean square error of prediction values down to 1.9%. Molten salt reactors (MSRs) will consist of a complex chemical and radiological system consistently producing new fission products as the reactor operates. Some of these fission products and/or their daughter species will leave the salt in the reactor off-gas. Monitoring the composition of the off-gas, as well as the salt itself, is important for monitoring reactor performance, including burnup, corrosion, and the concentration of impurities. Tritium is of concern for MSRs because it will be produced from the irradiation of key salt constituents, including Li and Be. LIBS offers an avenue for in situ salt and off-gas monitoring by firing a laser onto or into the sample stream to generate a plasma. The plasma light can be monitored to measure an elemental fingerprint of the sample. Extending this analysis to include isotopic ratios offers a critical expansion of the in situ monitoring capabilities being developed. This study demonstrates the expansion of Oak Ridge National Laboratory’s LIBS capabilities to monitor isotopes and shows how simple calibrations may provide rapid semiquantitative models.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of Lanthanides in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy

To enable the deployment of molten salt reactor technology, the development of off-gas treatment systems and advanced monitoring tools capable of operating with high temperatures and radiation fields while delivering near real-time information is necessary. Here, we aim to fulfill this requirement and proposes laser-induced breakdown spectroscopy (LIBS) for monitoring molten salt aerosol streams. A sheath gas measuring method was developed to protect optical elements from aerosol particles and to ensure a relatively constant aerosol stream for measurement. An aqueous system was studied to demonstrate the utility of LIBS for monitoring possible fission products in an aerosol stream: Gd, Nd, and Sm up to 2000 parts per million (ppm). A calibration model was built using partial least squares (PLS) regression with five, six, and nine latent variables for Gd, Nd, and Sm, respectively. This calibration model successfully estimated the concentrations of three test samples, which were validated with inductively charged plasma optical emission spectroscopy measurements at a 99.9% confidence interval. To enhance these models, a genetic algorithm was used to filter the spectra before entering the PLS model, thereby limiting the spectral features being regressed to those with greater correlations to concentration. This allowed for the number of latent variables used in the PLS models to be reduced to four, three, and three for Gd, Nd, and Sm, respectively. Finally, the genetic algorithm-filtered PLS models were used to predict the concentrations of the aerosol stream on a real-time dataset and resulted in a 73%, 18%, and 25% improvement in root mean squared error of prediction compared to the original PLS models developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of hydrogen and lithium isotopes using Laser-Induced Breakdown Spectroscopy

The detection and quantification of hydrogen (1,2,3H) and lithium (6,7Li) isotopes are critical to several energy and defense application areas, including hydrogen storage, nuclear forensics, and safeguards/non-proliferation. In this context, laser-induced breakdown spectroscopy (LIBS) is very promising and it comes with certain advantages such as rapid detection, and standoff capability. Although LIBS provides experimental simplicity and is capable of detecting all elements in the periodic table in any phase (solid, liquid, or gas), there exist certain challenges for isotopic analyses of H and Li due to spectral broadening, the presence of closely spaced fine and hyperfine structures, and line distortion effects (e.g., self-absorption and self-reversal) present in laser-produced plasmas. This article reports recent developments in H and Li isotopic analysis using LIBS, and existing challenges.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dust Removal on Mars Using Laser-Induced Breakdown Spectroscopy

Dust coatings on the surface of Mars complicate and, if sufficiently thick, mask the spectral characteristics and compositional determination of underlying material from in situ and remote sensing instrumentation. The Laser-Induced Breakdown Spectroscopy (LIBS) portion of the Chemistry & Camera (ChemCam) instrument, aboard the Mars Science Laboratory (MSL) rover, will be the first active remote sensing technique deployed on Mars able to remove dust. ChemCam utilizes a 5 ns pulsed 1067 nm high-powered laser focused to less than 400 m diameter on targets at distances up to 7 m [1,2]. With multiple laser pulses, dust and weathering coatings can be remotely analyzed and potentially removed using this technique [2,3]. A typical LIBS measurement during MSL surface operations is planned to consist of 50 laser pulses at ~14 mJ, with the first 5 to 10 pulses used to analyze as well as remove any surface coating. Additionally, ChemCam's Remote Micro-Imager (RMI) is capable of resolving 200 m details at a distance of 2 m, or 1 mm at 10 m [1,4]. In this study, we report on initial laboratory experiments conducted to characterize the removal of dust coatings using similar LIBS parameters as ChemCam under Mars-like conditions. These experiments serve to better understand the removal of surface dust using LIBS and to facilitate the analysis of ChemCam LIBS spectral data and RMI images.

Graff, T. G.↗

Partial Least Squares and Neural Networks for Quantitative Calibration of Laser-induced Breakdown Spectroscopy (LIBs) of Geologic Samples

The ChemCam instrument [1] on the Mars Science Laboratory (MSL) rover will be used to obtain the chemical composition of surface targets within 7 m of the rover using Laser Induced Breakdown Spectroscopy (LIBS). ChemCam analyzes atomic emission spectra (240-800 nm) from a plasma created by a pulsed Nd:KGW 1067 nm laser. The LIBS spectra can be used in a semiquantitative way to rapidly classify targets (e.g., basalt, andesite, carbonate, sulfate, etc.) and in a quantitative way to estimate their major and minor element chemical compositions. Quantitative chemical analysis from LIBS spectra is complicated by a number of factors, including chemical matrix effects [2]. Recent work has shown promising results using multivariate techniques such as partial least squares (PLS) regression and artificial neural networks (ANN) to predict elemental abundances in samples [e.g. 2-6]. To develop, refine, and evaluate analysis schemes for LIBS spectra of geologic materials, we collected spectra of a diverse set of well-characterized natural geologic samples and are comparing the predictive abilities of PLS, cascade correlation ANN (CC-ANN) and multilayer perceptron ANN (MLP-ANN) analysis procedures.

Anderson, R. B.↗