Search NASASearch

SEARCH · Search NASA

Results for “laser operating parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Interplanetary Microlaser Transponders

The feasibility of an asynchronous (i.e. independently firing) interplanetary laser transponder, capable of ranging between Earth and Mars and using the automated SLR2000 Satellite Laser Ranging (SLR) system as an Earth base station, has been suggested. Since that time, we have received a small amount of discretionary funding to further explore the transponder concept and to develop and test an engineering breadboard. Candidate operational scenarios for acquiring and tracking the opposite laser terminal over interplanetary distances have been developed, and breadboard engineering parameters were chosen to reflect the requirements of an Earth-Mars link Laboratory tests have been devised to simulate the Earth- Mars link between two independent SLR2000 transceivers and to demonstrate the transfer of range and time in single photon mode. The present paper reviews the concept of the asynchronous microlaser transponder, the transponder breadboard design, an operational scenario recently developed for an asteroid rendezvous, and the laboratory test setup. The optical head of the transponder breadboard fits within a cylinder roughly 15 cm in diameter and 32 cm in length and is mounted in a commercial two axis gimbal driven by two computer-controlled stepper motors which allows the receiver optical axis to be centered on a simulated Earth image. The optical head is built around a small optical bench which supports a 14.7 cm diameter refractive telescope, a prototype 2 kHz SLR2000 microlaser transmitter, a quadrant microchannel plate photomultiplier (MCP/PMT), a CCD array camera, spatial and spectral filters, assorted lenses and mirrors, and protective covers and sun shields. The microlaser is end-pumped by a fiber-coupled diode laser array. An annular mirror is employed as a passive transmit/receive (T/R) switch in an aperture-sharing arrangement wherein the transmitted beam passes through the central hole and illuminates only the central 2.5 cm of the common telescope (adequate to achieve a 10 arcsecond full laser beam divergence) while the receiver uses the remainder of the 14.7 cm aperture. Additional electronic instrumentation includes the diode pump array and associated heat sink and current drivers, rubidium frequency standard, timing distribution module, range gate generator, a recently developed all-digital correlation range receiver, and system computer. Acquisition of the opposite transponder terminal requires a search within a three-dimensional volume determined by the initial pointing uncertainty and a maximum 500 microsecond uncertainty in the laser time of fire at the opposite terminal for totally uncorrelated Earth and spacecraft clocks. The angular search is aided by a sensitive CCD array capable of imaging the Earth, Moon, and surrounding stars within the nominal + 0.5 degree cone of uncertainty associated with the initial pointing of a spacecraft body or microwave communications dish.

Degnan, John J.

Long-duration Operation of 2-micron Coherent Doppler Lidar in Space

The reliability and lifetime of laser remote sensing systems that can operate autonomously over a sufficiently long period are mainly constrained by the laser diode arrays (LDAs) used for pumping their laser transmitters. The lifetime of a 2-micron coherent lidar operating in space is particularly of concern in lieu of required pump pulse duration of Thulium and Holmium solid state lasers (approx. 1msec) that are considerably longer than those of more widely used 1-micron lasers (< 0.2 msec). A factor of 5 to 10 times longer pulse duration can easily translate to over an order of magnitude shorter lifetime for a typical commercially available high-power 2-D array. Therefore, it is imperative to address the lifetime and reliability of LDAs for pumping 2-micron lasers by exploring all the potential options that significantly prolong their life meeting the required operational lifetime of space-based coherent Doppler lidars. The leading causes of sudden failure and premature degradation of LDAs are intrinsic semiconductor defects, optical facet breakdown resulting from excessive localized heating, and thermo-mechanical stresses due to the extreme thermal cycling of the laser active regions1-2. Long pulse operation grossly amplifies the impact of these failure/degradation causes, particularly the thermo-mechanical stresses due to pulse-to-pulse thermal cycling. Therefore, several experimental setups have been developed to investigate each of the failure mechanisms and causes of premature degradation in order to evaluate various package designs, define the best operating parameters, and to guide the technology advancement, leading to highly reliable and very long lifetime LDAs5. Several areas of improvement in the packaging and fabrication process of laser diodes have already been identified and efforts towards implementing these improvements are well underway. These efforts include the use of advanced high thermal conductivity materials for packaging of laser diode arrays and new fabrication techniques for mechanically attaching laser diode bars and submounts. But even using the existing LDAs, it may be possible to increase the lifetime by careful selection of the package type, number of bars per package and their pitch, operational temperature, and operating parameters such repetition rate, pulsewidth, and applied current. Obviously, the LDA specification and operational parameters will involve a system level trade analysis to ensure that the lidar instrument meets its performance objectives. One goal of this work is to enable such trade analysis by evaluating LDAs from different suppliers in different package types and quantifying their performance as a function of their operational parameters.

Amzajerdian, Farzin

Optimized Biasing of Pump Laser Diodes in a Highly Reliable Metrology Source for Long-Duration Space Missions

Optical metrology system reliability during a prolonged space mission is often limited by the reliability of pump laser diodes. We developed a metrology laser pump module architecture that meets NASA SIM Lite instrument optical power and reliability requirements by combining the outputs of multiple single-mode pump diodes in a low-loss, high port count fiber coupler. We describe Monte-Carlo simulations used to calculate the reliability of the laser pump module and introduce a combined laser farm aging parameter that serves as a load-sharing optimization metric. Employing these tools, we select pump module architecture, operating conditions, biasing approach and perform parameter sensitivity studies to investigate the robustness of the obtained solution.

808 mm diode pumps

Mission Status, On-Orbit Performance, and Lessons Learned of the Global Ecosystem Dynamics Investigation (GEDI) Lidar Laser Transmitters

The Global Ecosystems Dynamics Investigation (GEDI) Lidar, is a global 3-dimensional biomass lidar instrument aboard the International Space Station (ISS) and the Japanese Experiment Module (JEM). Its core mission is to measure the global carbon balance of Earth’s forests with 3 laser transmitters using multi-beam waveform-capture methods. GEDI’s laser transmitter concept was originally funded by NASA Goddard’s Earth Science Technology Office (ESTO) for future Earth Altimetry and Lidar missions ~ 20 years ago, and after a long road of development, the first flight-ready unit was a 10 mJ-class system for GEDI’s ISS-based specifications. Furthermore, no adjustment in drive parameters has been required nor significant decay detected after 4 years of near continuous operation of 3 on-board lasers, which were designed for a 2-year mission. We report on the GEDI laser design process, their on-orbit performance, the major lessons learned, and some critical insight into our in-house flight quality development process that enabled their delivery within budget, schedule, and low risk extended mission life capability.

D. Barry Coyle

Optimizing a Laser Process for Making Carbon Nanotubes

A systematic experimental study has been performed to determine the effects of each of the operating conditions in a double-pulse laser ablation process that is used to produce single-wall carbon nanotubes (SWCNTs). The comprehensive data compiled in this study have been analyzed to recommend conditions for optimizing the process and scaling up the process for mass production. The double-pulse laser ablation process for making SWCNTs was developed by Rice University researchers. Of all currently known nanotube-synthesizing processes (arc and chemical vapor deposition), this process yields the greatest proportion of SWCNTs in the product material. The aforementioned process conditions are important for optimizing the production of SWCNTs and scaling up production. Reports of previous research (mostly at Rice University) toward optimization of process conditions mention effects of oven temperature and briefly mention effects of flow conditions, but no systematic, comprehensive study of the effects of process conditions was done prior to the study described here. This was a parametric study, in which several production runs were carried out, changing one operating condition for each run. The study involved variation of a total of nine parameters: the sequence of the laser pulses, pulse-separation time, laser pulse energy density, buffer gas (helium or nitrogen instead of argon), oven temperature, pressure, flow speed, inner diameter of the flow tube, and flow-tube material.

Arepalli, Sivaram

Initial conceptual design study of self-critical nuclear pumped laser systems

An analytical study of self-critical nuclear pumped laser system concepts was performed. Primary emphasis was placed on reactor concepts employing gaseous uranium hexafluoride (UF6) as the fissionable material. Relationships were developed between the key reactor design parameters including reactor power level, critical mass, neutron flux level, reactor size, operating pressure, and UF6 optical properties. The results were used to select a reference conceptual laser system configuration. In the reference configuration, the 3.2 m cubed lasing volume is surrounded by a graphite internal moderator and a region of heavy water. Results of neutronics calculations yield a critical mass of 4.9 U(235) in the form (235)UF6. The configuration appears capable of operating in a continuous steady-state mode. The average gas temperature in the core is 600 K and the UF6 partial pressure within the lasing volume is 0.34 atm.

Rodgers, R. J.

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: Spectroscopic in situ nanotube detection using spectral absorption and surface temperature measurements by black body emission

Carbon nanotubes hold great promise for material advancements in the areas of composites and electronics. The advancement of research in these areas is dependent upon the availability of carbon nanotubes to a broad spectrum of academic and industrial researchers. Although there has been much progress made in reducing the costs of carbon nanotubes and increasing the quality and purity of the products, an increase in demand for still less expensive and specific nanotubes types has also grown. This summer's work has involved two experiments that have been designed to further the understanding of the dynamics and chemical mechanisms of carbon nanotube formation. It is expected that a better understanding of the process of formation of nanotubes will aid current production designs and stimulate ideas for future production designs increasing the quantity, quality, and production control of carbon nanotubes. The first experiment involved the measurement of surface temperature of the target as a function of time with respect to the ablation lasers. A peak surface temperature of 5000 K was determined from spectral analysis of black body emission from the target surface. The surface temperature as a function of various changes in operating parameters was also obtained. This data is expected to aid the modeling of ablation and plume dynamics. The second experiment involved a time and spatial measurement of the spectrally resolved absorbance of the laser produced plume. This experiment explored the possibility of developing absorbance and fluorescence to detect carbon nanotubes during production. To attain control over the production of nanotubes with specific properties and reduce costs, a real time in situ diagnostics method would be very beneficial. Results from this summer's work indicate that detection of nanotubes during production may possibly be used for production feed back control.

DeBoer, Gary D.

Comparison of laser models

Progress on the comparison of laser models is reported. Equations for an oscillatory model and a nonoscillatory model for the simulation of iodine laser operation are solved. Reaction rate coefficients used in both models are listed. Currently there are four models for the simulation of iodine laser operation are solved. Reaction rate coefficients used in both models are listed. Currently there are four models for the simulation of an iodine laser. They are: (1) a time dependent model; (2) a quasi-steady state model; (3) a noncompressible model; and (4) a compressible flow laser model. Current research is being directed toward: (1) parameter studies using the compressible flow laser model; (2) development of a two-pass amplifier model; and (3) solving a system of equations describing operation of the high powered iodine MOPA (master oscillator power amplifier).

Heinbockel, John H.

Interfaces for high-speed fiber-optic links - Analysis and experiment

An analysis of directly and externally modulated fiberoptic links is presented. The theoretical analysis is based on the signal flow diagram of the interface circuits to the laser diode, Mach-Zehnder electro-optic modulator, and p-i-n photodiode. System parameters such as gain, noise figure, two-tone intermodulation distortion, and spurious free and compression dynamic range are expressed as a function of frequency and operating point of the laser and external modulator. Two directly and externally modulated fiber-optic links were designed and fabricated to verify the analytical models. The direct modulation FO link was developed at the Ku-band (11.6-12.4 GHz), whereas the external modulation link was at L-band (875-925 MHz). Spurious-free dynamic ranges of 95.8 dB-Hz exp 2/3 and 113 dB-Hz exp 2/3, respectively, were achieved. The predictions based on the analytical models match the measured results.

Daryoush, Afshin S.

Performance Considerations for the SIMPL Single Photon, Polarimetric, Two-Color Laser Altimeter as Applied to Measurements of Forest Canopy Structure and Composition

The Slope Imaging Multi-polarization Photon-counting Lidar (SIMPL) is a multi-beam, micropulse airborne laser altimeter that acquires active and passive polarimetric optical remote sensing measurements at visible and near-infrared wavelengths. SIMPL was developed to demonstrate advanced measurement approaches of potential benefit for improved, more efficient spaceflight laser altimeter missions. SIMPL data have been acquired for wide diversity of forest types in the summers of 2010 and 2011 in order to assess the potential of its novel capabilities for characterization of vegetation structure and composition. On each of its four beams SIMPL provides highly-resolved measurements of forest canopy structure by detecting single-photons with 15 cm ranging precision using a narrow-beam system operating at a laser repetition rate of 11 kHz. Associated with that ranging data SIMPL provides eight amplitude parameters per beam unlike the single amplitude provided by typical laser altimeters. Those eight parameters are received energy that is parallel and perpendicular to that of the plane-polarized transmit pulse at 532 nm (green) and 1064 nm (near IR), for both the active laser backscatter retro-reflectance and the passive solar bi-directional reflectance. This poster presentation will cover the instrument architecture and highlight the performance of the SIMPL instrument with examples taken from measurements for several sites with distinct canopy structures and compositions. Specific performance areas such as probability of detection, after pulsing, and dead time, will be highlighted and addressed, along with examples of their impact on the measurements and how they limit the ability to accurately model and recover the canopy properties. To assess the sensitivity of SIMPL's measurements to canopy properties an instrument model has been implemented in the FLIGHT radiative transfer code, based on Monte Carlo simulation of photon transport. SIMPL data collected in 2010 over the Smithsonian Environmental Research Center, MD are currently being modelled and compared to other remote sensing and in situ data sets. Results on the adaptation of FLIGHT to model micropulse, single'photon ranging measurements are presented elsewhere at this conference. NASA's ICESat-2 spaceflight mission, scheduled for launch in 2016, will utilize a multi-beam, micropulse, single-photon ranging measurement approach (although non-polarimetric and only at 532 nm). Insights gained from the analysis and modelling of SIMPL data will help guide preparations for that mission, including development of calibration/validation plans and algorithms for the estimation of forest biophysical parameters.

Dabney, Philip W.

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N

Optimized matching conditions for self-guided laser wakefield accelerators

We revisit the matching conditions for self-guided laser pulse propagation in plasma and refine their formulation to maximize the energy of electrons produced via laser wakefield acceleration. Bayesian optimization, combined with particle-in-cell simulations carried out in a quasi-three-dimensional geometry and a Lorentz-boosted frame, is employed. The optimization identifies the maximum electron energy that a self-guided laser wakefield accelerator, driven by a laser of a given energy, can produce, together with the corresponding acceleration distance. Our results further demonstrate that electrons with energies close to the maximum value can be obtained across a relatively wide range of input parameters and without the need for their precise tuning. This provides substantial flexibility for experimental implementation and significantly relaxes the operational constraints associated with self-guided laser wakefield accelerators.

43 PARTICLE ACCELERATORS

A piston-actuated shock-tube, with laser-Schlieren diagnostics

The essential construction features of a piston actuated shock tube are described, and its advantages relative to the conventional use of diaphragm ruptures for shock initiation are listed. Typical operational parameters are presented to illustrate the levels of reproducibility achieved. Tests with He and N2 drivers into about 99 percent Ar covered shock speeds from 1.539 +/- 0.002-0.8143 +/- 0.002 mm/microsec, corresponding to 2390-847 K incident shock temperatures. Application of this tube for recording postshock front density gradients of the endoergic dissociation of ethane and the exoergic condensation of iron atoms via the laser-Schlieren technique is described.

Hurst, S. M.

Real-time atmospheric absorption spectra for in-flight tuning of an airborne dial system

Real-time measurements of atmospheric absorption spectra are displayed and used to precisely calibrate and fix the frequency of an Alexandrite laser to specific oxygen absorption features for airborne Differential Absorption Lidar (DIAL) measurements of atmospheric pressure and temperature. The DIAL system used contains two narrowband tunable Alexandrite lasers: one is electronically scanned to tune to oxygen absorption features for on-line signals while the second is used to obtain off-line (nonabsorbed) atmospheric return signals. The lidar operator may select the number of shots to be averaged, the altitude, and altitude interval over which the signals are averaged using single key stroke commands. The operator also determines exactly which oxygen absorption lines are scanned by comparing the line spacings and relative strengths with known line parameters, thus calibrating the laser wavelength readout. The system was used successfully to measure the atmospheric pressure profile on the first flights of this lidar, November 20, and December 9, 1985, aboard the NASA Wallops Electra aircraft.

Dombrowski, M.

Closed cycle electric discharge laser design investigation

Closed cycle CO2 and CO electric discharge lasers were studied. An analytical investigation assessed scale-up parameters and design features for CO2, closed cycle, continuous wave, unstable resonator, electric discharge lasing systems operating in space and airborne environments. A space based CO system was also examined. The program objectives were the conceptual designs of six CO2 systems and one CO system. Three airborne CO2 designs, with one, five, and ten megawatt outputs, were produced. These designs were based upon five minute run times. Three space based CO2 designs, with the same output levels, were also produced, but based upon one year run times. In addition, a conceptual design for a one megawatt space based CO laser system was also produced. These designs include the flow loop, compressor, and heat exchanger, as well as the laser cavity itself. The designs resulted in a laser loop weight for the space based five megawatt system that is within the space shuttle capacity. For the one megawatt systems, the estimated weight of the entire system including laser loop, solar power generator, and heat radiator is less than the shuttle capacity.

Baily, P. K.

Preliminary submillimeter spectroscopic measurements using a submillimeter heterodyne radiometer

A submillimeter heterodyne radiometer uses a submillimeter laser, pumped by a CO2 laser, as a local oscillator and a room temperature Schottky barrier diode as the first IF mixer. The radiometer can resolve spectral lines in the submillimeter region of the spectrum (arising from pure rotational molecular transitions) to within 0.3 MHz, using acousto-optic spectrum analyzer which measures the power spectrum by simultaneously sampling 0.3 MHz wide channels over a 100 MHz bandwidth spanning the line. Preliminary observations of eight spectral lines of H2O2, CO, NH3 and H2O, all lying in the 434-524 micrometer wavelength range are described. All eight lines were observed using two local oscillator frequencies obtained by operating the submillimeter laser with either methyl fluoride (CH3F) or formic acid (HCOOH) as the lasing gas. Sample calculations of line parameters from the observed data show good agreement with established values. One development goal is the size and weight reduction of the package to make it suitable for balloon or shuttle experiments to detect trace gases in the upper atmosphere.

Safren, H. G.

Qualification Testing of Laser Diode Pump Arrays for a Space-Based 2-micron Coherent Doppler Lidar

The 2-micron thulium and holmium-based lasers being considered as the transmitter source for space-based coherent Doppler lidar require high power laser diode pump arrays operating in a long pulse regime of about 1 msec. Operating laser diode arrays over such long pulses drastically impact their useful lifetime due to the excessive localized heating and substantial pulse-to-pulse thermal cycling of their active regions. This paper describes the long pulse performance of laser diode arrays and their critical thermal characteristics. A viable approach is then offered that allows for determining the optimum operational parameters leading to the maximum attainable lifetime.

Amzajerdian, Farzin

Theory of the optimally coupled Q-switched laser

The general equations describing Q-switched laser operation are transcendental in nature and require numerical solutions, which greatly complicates the optimization of real devices. Here, it is shown that, using the mathematical technique of Lagrange multipliers, one can derive simple analytic expressions for all of the key parameters of the optimally coupled laser, i.e., one which uses an optimum reflector to obtain maximum laser efficiency for a given pump level. These parameters can all be expressed as functions of a single dimensionless variable z, defined as the ratio of the unsaturated small-signal gain to the dissipative (nonuseful) optical loss, multiplied by a few simple constants. Laser design tradeoff studies and performance projections can be accomplished quickly with the help of several graphs and a simple hand calculator. Sample calculations for a high-gain Nd:YAG and a low-gain alexandrite laser are presented as illustrations of the technique.

Degnan, John J.