Laser frequency stabilization using a molecular beam Final report, 1 Feb. - 31 Dec. 1969
Iodine molecular beam absorption resonance as long-term frequency reference for argon ion laser stabilization
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Iodine molecular beam absorption resonance as long-term frequency reference for argon ion laser stabilization
Long-term absolute frequency stabilization of a laser oscillator is obtained when the lasers oscillation frequency is referenced to the exact center of an atomic transition. A laser amplifier acts as a discriminant to indicate when the laser frequency deviates from the center of its atomic transistion.
A software-based method for real-time, active stabilization of tunable diode laser spectral scans is described. The procedure is suitable for use with field and laboratory instrumentation where automated, unattended spectrometer operation is required. An autocorrelation of two high-resolution reference gas infrared spectra is computed at regular intervals, and the location of the maximum value of the autocorrelation provides the relative abscissa shift between the spectra. Small adjustments to the laser scan parameters are thereby made to ensure that drifts in the laser output frequency are tracked and compensated. Calculations required for stabilization of a 512-point spectrum can be completed in under 25 ms using an inexpensive, moderate-speed, array processor installed in a PC.
Compact hollow-core photonic crystal fiber (HC-PCF)gas frequency reference cell was constructed using a novel packaging technique that relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers. The use of this gas cell for laser frequency stabilization was demonstrated by locking a tunable diode laser to the center of the P9 line from the (nu)1+(nu)3 band of acetylene with RMS frequency error of 2.06 MHz over 2 hours. This effort was performed in support of a task to miniaturize the laser frequency stabilization subsystem of JPL/LMCT Laser Absorption Spectrometer (LAS) instrument.
Frequency stabilization of laser oscillator against reference laser amplifier, noting residual AM effects
Frequency and stability measurements in far IR laser region
Frequency stabilization of far infrared laser
We are developing frequency stabilized lasers in support of NASA's time-varying-gravity mapping missions. Small changes in the distance between spacecraft will be detected using interferometric techniques between two satellites with on-board stable lasers.
Laser frequency stability and spectral purity
Frequency and stability measurements of IF signals generated between laser far IR radiations and conventional oscillators
Flight Electronics Division of Langley Research Center is developing a spaceflight experiment called the Stanford University and NASA Laser In-Space Technology (SUNLITE). The objective of the project is to explore the fundamental limits on frequency stability using an FM laser locking technique on a Nd:YAG non-planar ring (free-running linewidth of 5 KHz) oscillator in the vibration free, microgravity environment of space. Compact and automated actively stabilized terahertz laser oscillators will operate in space with an expected linewidth of less than 3 Hz. To implement and verify this experiment, NASA engineers have designed and built a state of the art, space qualified high speed data acquisition system for measuring the linewidth and stability limits of a laser oscillator. In order to achieve greater stability and better performance, an active frequency control scheme requiring the use of a feedback control loop has been applied. In the summer of 1991, the application of control theory in active frequency control as a frequency stabilization technique was investigated. The results and findings were presented in 1992 at the American Control Conference in Chicago, and have been published in Conference Proceedings. The main focus was to seek further improvement in the overall performance of the system by replacing the analogue controller by a digital algorithm.
We evaluated thermal noise (Brownian motion) in a rigid reference cavity used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with t.he direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency- reference cavity of order 1 Hz/square root Hz(0.01 Hz/square root Hz) at 10 mHz (100 Hz) at room temperature. This level coincides with the world-highest level stabilization results.
We evaluated thermal noise (Brownian motion) in a rigid reference cavity Used for frequency stabilization of lasers, based on the mechanical loss of cavity materials and the numerical analysis of the mirror-spacer mechanics with the direct application of the fluctuation dissipation theorem. This noise sets a fundamental limit for the frequency stability achieved with a rigid frequency-reference cavity of order 1 Hz/rtHz at 10mHz at room temperature. This level coincides with the world-highest level stabilization results.
Phase-locking scheme for frequency-stabilized gas laser oscillators
Frequency stabilization technique for carbon dioxide laser operating at 10.6 microns
One of the goals of the Stanford University-NASA Laser-In-space Technology Experiment (SUNLITE) program is to develop ultrastable optical frequency oscillators that can lead to high resolution time standards and ultimately standard clocks. During the past year or two there was remarkable progress towards achieving in the laboratory the fundamental quantum limits for the frequency stability of nonplanar ring oscillator (NPRO) lasers. The quantum theoretical limits for laser oscillator stability are reviewed, measured stability levels compared, and some applications of such ultrastable laser oscillator systems suggested.
The GRACE mission monitors changes in the Earth's gravity field by measuring changes in the distance between spacecraft induced by that changing field. The distance variation is measured with a microwave ranging system with sub-micron accuracy. The ranging measurement accuracy is limited by the signal-to-noise ratio and by the frequency stability of the microwave signal referenced to an ultra-stable oscillator (USO). For GRACE-2 a laser ranging system is envisioned with accuracy better than the GRACE microwave ranging system. A laser ranging system easily provides an improved signal-to-noise ratio over the microwave system. Laser frequency stability better than the GRACE USO stability has been demonstrated in several laboratories using thermally stabilized optical cavities. We are developing a space-qualifiable optical cavity and associated optics and electronics for use on GRACE-2 to provide a stable frequency reference for the laser ranging system. Two breadboard units have been developed and tested for performance and ability to survive launch and orbit environments. A prototype unit is being designed using lessons learned from tests of the breadboard units.
SUNLITE is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. This paper describes the thermal stability requirements on the cavity design and detailed thermal analysis performed, as well as thermal testing that was performed on a prototype. Analytical thermal models were correlated to the test data and additional modeling of the current design is presented. Suggestions for improving similar high-precision thermal tests are given.