Search NASA⌕ Search

SEARCH · Search NASA

Results for “leakage monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Node Monitoring as a Fault Detection Countermeasure against Information Leakage within a RISC-V Microprocessor

Advanced, superscalar microprocessors (μP) are highly susceptible to wear-out failures because of their highly complex, densely packed circuit structure and extreme operational frequencies. Although many types of fault detection and mitigation strategies have been proposed, none have addressed the specific problem of detecting faults that lead to information leakage events on I/O channels of the μP. Information leakage can be defined very generally as any type of output that the executing program did not intend to produce. In this work, we restrict this definition to output that represents a security concern, and in particular, to the leakage of plaintext or encryption keys, and propose a counter-based countermeasure to detect faults that cause this type of leakage event. Fault injection (FI) experiments are carried out on two RISC-V microprocessors emulated as soft cores on a Xilinx multi-processor System-on-chip (MPSoC) FPGA. The μP designs are instrumented with a set of counters that records the number of transitions that occur on internal nodes. The transition counts are collected from all internal nodes under both fault-free and faulty conditions, and are analyzed to determine which counters provide the highest fault coverage and lowest latency for detecting leakage faults. We show that complete coverage of all leakage faults is possible using only a single counter strategically placed within the branch compare logic of the μPs.

42 ENGINEERING↗

Economic assessment of seismic monitoring for underground hydrogen storage

Underground hydrogen storage (UHS) plays a key role in the energy landscape. However, like other subsurface engineering technologies, UHS may cause leakage into the groundwater or atmosphere and possibly induce local seismicity. To reduce these risks, seismic monitoring could be a viable technique to track the UHS plume, detect leakages, and locate induced seismicity events. Seismic monitoring has been proposed to safely monitor UHS, but research in this area is still new and requires field studies. Lab and theoretical studies have demonstrated the validity of seismic monitoring for UHS. Therefore, it is imperative to analyze the economic feasibility of seismic monitoring for UHS. Hence, we develop a cost model and open-source Python code for seismic monitoring that considers types of seismometers, comprehensive operational scenarios, detection thresholds, and long-term leakage monitoring. A case study is further provided to validate the cost model on reservoir simulations of UHS. We find that the levelized cost for a 10-year operating UHS site will range on the order of ∼0.003 $\$$/kg. The methods developed in this study could also be applied to the monitoring of groundwater, gas, and/or wastewater injection.

08 HYDROGEN↗

Quantum Fourier Transform with Leakage Control

In circuit QED (cQED) systems, one can manipulate the cavity Fock states to use quantum processing unit (QPU). Since the coherence times of the Fock states are long, qudit based computation can be possible. One of the most basic gate that can be engineered in this cQED platform is the displacement gate, $D(\alpha)$. However, accessible number of qudit-levels is finite. The truncated displacement gate on the qudit is the source of theoretical error above the logical states and needs to be addressed. In this work, we monitor and minimize the leakage in qudit systems that involves displacement gate by introducing so-called `bumper' states and a modified cost function.

Kurkcuoglu, D. [Fermilab] (ORCID:0000000311097074)↗

In-situ proton radiation testing of 2.4 micron wavelength extended InGaAs photodiodes at dry ice and room temperatures

We have successfully tested 290 µm diameter, 2.4 micron wavelength, Extended InGaAs photodiodes coupled with single mode fiber using 50 MeV Protons at both dry ice temperature (-72 °C) and room temperature (20 °C). The devices were reverse biased at 100 mV during the radiation run and their leakage current was continuously monitored insitu during the exposure. These devices find multiple applications in space for spectroscopy & sensing, inter-satellite optical communication links, rapid Doppler shift LIDAR, as well as inter-planetary and Earth-to-Moon communication links. Several photodiodes were tested using 50 MeV Protons with an average flux level of 2.11 × 10 7 protons/cm 2 /s, for a total fluence of 1.0 × 10 11 protons/cm 2 and total dose of 20 krad (water). Pre- and post-radiation results were also measured for leakage current vs. voltage, responsivity (quantum efficiency), and bandwidth of the Extended InGaAs photodiodes. Finally, all devices were found to be fully functional at normal operating conditions and at both dry ice and room temperature.

2.4 micron wavelength↗

A steerable radiator for spacecraft application

Future large space structures such as the Space Station will have high dissipation and long life requirements which dictate the requirements for steerable radiators. Several rotary coupling concepts were considered to accomplish heat transport across the steerable radiator system's rotating interface. Rotary fluid couplings were chosen over rotary contact couplings or flexible lines because of low temperature gradients and operational flexibility. A rotary fluid coupling has been designed for use on initial operating capability (IOC) and growth Space Station. Its internal seals have been demonstrated to a 10 year life with minimal (0.055 lbm NH3/year) leakage between internal passages. Materials compatibility tests have been conducted to demonstrate compatibility with ammonia. A seal leakage management system has been designed to: (1) monitor pressures between the internal seals, (2) remove leakage, and (3) store the leakage fluid in a reservoir.

Heizer, B. L.↗

Time-lapse seismic data inversion for estimating reservoir parameters using deep learning

Geologic carbon sequestration involves the injection of captured carbon dioxide ([Formula: see text]) into subsurface formations for long-term storage. The movement and fate of the injected [Formula: see text] plume is of great concern to regulators because monitoring helps to identify potential leakage zones and determines the possibility of safe long-term storage. To address this concern, we design a deep-learning framework for [Formula: see text] saturation monitoring to determine the geologic controls on the storage of the injected [Formula: see text]. We use different combinations of porosities and permeabilities for a given reservoir to generate saturation and velocity models. We train the deep-learning model with a few time-lapse seismic images and their corresponding changes in saturation values for a particular [Formula: see text] injection site. The deep-learning model learns the mapping from the change in the time-lapse seismic response to the change in [Formula: see text] saturation during the training phase. We then apply the trained model to data sets comprising different time-lapse seismic image slices (corresponding to different time instances) generated using different porosity and permeability distributions that are not part of the training to estimate the [Formula: see text] saturation values along with the plume extent. Our algorithm provides a deep-learning assisted framework for the direct estimation of [Formula: see text] saturation values and plume migration in heterogeneous formations using the time-lapse seismic data. Our method improves the efficiency of time-lapse inversion by streamlining the large number of intermediate steps in the conventional time-lapse inversion workflow. This method also helps to incorporate the geologic uncertainty for a given reservoir by accounting for the statistical distribution of porosity and permeability during the training phase. Tests on different examples verify the effectiveness of our approach.

Geochemistry & Geophysics↗

Identification of potential CO 2 leakage pathways and mechanisms in oil reservoirs using fault tree analysis

Geological storage of CO 2 technologies has become an important and effective way to reduce the greenhouse gas emissions, especially when it is combined with CO 2 enhanced oil recovery (EOR), which can not only trap CO 2 but also enhance oil recovery. However, the risk of CO 2 leakage has always been a prominent issue. In this paper, the mechanisms and pathways of CO 2 leakage during geological storage in oil reservoirs were analyzed using fault tree analysis (FTR). Besides, monitoring technologies were discussed and deployed in a CO 2 EOR demonstration project. The analysis results showed that the sealing failures of oil producer and CO2 injector wells, like well cement failure and casing failure, are the main reasons for the CO 2 leakage, which has been observed in the oil field monitoring project. The monitoring results indicated that there is no large-scale CO 2 leakage, while relatively high and abnormal CO 2 concentration in soil gas near some wellbores are observed, which indicates there is some leakage of CO 2 through incomplete cement ring and well casing string. FTR results provide guidelines for monitoring and preventing of CO 2 leakage during geological storage in oil reservoirs. Finally, the near-surface monitoring methods, especially the soil gas monitoring technologies, can effectively detect the leakage of CO 2 , and are a proper method for CO 2 leakage monitoring.

58 GEOSCIENCES↗

Susceptibility to Cracking of Different Lots of CDR35 Capacitors

On-orbit flight anomalies that occurred after several months of operation were attributed to excessive leakage currents in CDR35 style 0.47 microF 50 V capacitors operating at 10 V. In this work, a lot of capacitors similar to the lot that caused the anomaly have been evaluated in parallel with another lot of similar parts to assess their susceptibility to cracking under manual soldering conditions and get insight into a possible mechanism of failure. Leakage currents in capacitors were monitored at different voltages and environmental conditions before and after terminal solder dip testing that was used to simulate thermal shock during manual soldering. Results of cross-sectioning, acoustic microscopy, and measurements of electrical and mechanical characteristics of the parts have been analyzed, and possible mechanisms of failures considered. It is shown that the susceptibility to cracking and failures caused by manual soldering is lot-related. Recommendations for testing that would help to select lots that are more robust against manual soldering stresses and mitigate the risk of failures suggested.

cracking↗

Robotics for HVAC applications: A critical review and future perspectives

Recent advances in artificial intelligence (AI), enhanced computational capabilities, and innovations in sensors and hardware have driven the increasing development and application of robots in heating, ventilation, and air conditioning (HVAC) systems. We selected and reviewed 101 studies published between 2005 and 2025, sourced from IEEE Xplore, Scopus, Web of Science, and the ACM Digital Library. To analyze these works, we developed a five-dimensional analytical framework (morphology, sensing, navigation, task execution, and system integration), inspired by the Springer Handbook of Robotics and tailored specifically for robotic applications in HVAC. Based on the reviewed studies, six distinct tasks spanning the entire HVAC lifecycle have been identified. Among the six tasks, inspection and maintenance dominate (59 %), followed by indoor monitoring and auditing (21 %), whereas leakage detection, comfort support, and installation/retrofit remain less explored. To address the identified gaps, this review proposes future research directions including investigating robot-aware HVAC design principles, developing multimodal HVAC sensing and data fusion techniques, enhancing robot training and hardware capabilities, and expanding robotic applications beyond Maintenance and Operations (M&O). The findings from this review inform future robotics research for HVAC applications and ultimately enhance system affordability, energy efficiency, resilience or reliability, and occupant environmental comfort. Moreover, it seeks to inspire researchers to explore the intersections of robotics, computer science, building science, and HVAC engineering fostering advancements in this multidisciplinary field.

AI↗

Leak detector Patent

Fluid leakage detection system with automatic monitoring capability

Lockard, M. L.↗

Safety issues of defective lithium-ion batteries: identification and risk evaluation

Lithium-ion batteries inevitably suffer minor damage or defects caused by external mechanical abusive loading, e.g. , penetration, deformation, and scratch without triggering a hard/major short circuit. The replacement of cells becomes a dilemma if the safety risk of the defective batteries remains unknown. Herein, by introducing a representative defect form, i.e. , screw indentation, we demonstrate the safety characteristics of defective batteries. We prove that defective batteries have a significantly increased thermal risk and deteriorated mechanical integrity, but can go undetected due to prompt voltage recovery and insignificant local temperature increase. We discover that the voltage curve within the first few cycles contains sufficient information to identify defective batteries from otherwise good ones and propose methodologies to monitor the cells. Capacity loss and current leakage are two characteristics that can be estimated using the voltage curve. According to the defect size and position, the capacity loss could be 1 to 10 2 mA h and the leakage current could be 5–50 mA. Results remove the barriers for defective battery safety risk evaluation, enabling identification, monitoring, and early warning of minor damaged batteries.

25 ENERGY STORAGE↗

Legacy Well Leakage Risk Analysis at the Farnsworth Unit Site

This paper summarizes the results of the risk analysis and characterization of the CO 2 and brine leakage potential of Farnsworth Unit (FWU) site wells. The study is part of the U.S. DOE’s National Risk Assessment Partnership (NRAP) program, which aims to quantitatively evaluate long-term environmental risks under conditions of significant geologic uncertainty and variability. To achieve this, NRAP utilizes risk assessment and computational tools specifically designed to quantify uncertainties and calculate the risk associated with geologic carbon dioxide (CO 2 ) sequestration. For this study, we have developed a workflow that utilizes physics-based reservoir simulation results as input to perform leakage calculations using NRAP Tools, specifically NRAP-IAM-CS and RROM-Gen. These tools enable us to conduct leakage risk analysis based on ECLIPSE reservoir simulation results and to characterize wellbore leakage at the Farnsworth Unit Site. We analyze the risk of leakage from both individual wells and the entire field under various wellbore integrity distribution scenarios. The results of the risk analysis for the leakage potential of FWU wells indicate that, when compared to the total amount of CO 2 injected, the highest cemented well integrity distribution scenario (FutureGen high flow rate) exhibits approximately 0.01% cumulative CO 2 leakage for a 25-year CO 2 injection duration at the end of a 50-year post-injection monitoring period. In contrast, the highest possible leakage scenario (open well) shows approximately 0.1% cumulative CO 2 leakage over the same time frame.

54 ENVIRONMENTAL SCIENCES↗

Mechanistic modeling of CO 2 well leakage in a generic abandoned well through a bridge plug cement-casing gap

Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.

58 GEOSCIENCES↗

Development of spiral-groove self-acting face seals

An experimental evaluation and a 100-hour endurance test were performed on a spiral groove geometry, self-acting face seal. The seal was tested and operated successfully at maximum conditions of 243.8 m/s surface speed, 199.9 N/sq cm air pressure, and 645.4K (702 F) air temperature. The maximum speed condition of 243.8 m/s was obtained at a shaft speed of 72,500 rpm. Seal wear, gas leakage, and sealing element temperature were monitored during the test. Condition of the seal at the completion of the test was documented and found acceptable for further use. The spiral groove wear rate measured during the endurance test indicates a minimum potential seal life of over 2700 hours. Seal air leakage measured during the test program is within the range considered acceptable for consideration for use in a small gas turbine engine.

Obrien, M.↗

An adaptable technique for comparative image assessment: Application to crosswell electromagnetic survey design for fluid monitoring

Reservoir integrity stewardship accompanying carbon capture and sequestration considers fluid extraction and reinjection as a risk-mitigating method against overpressuring that could lead to caprock damage and ensuing [Formula: see text] leakage. Crosswell electromagnetics offers a technically viable monitoring method with the spatial volume coverage necessary for reservoir-encompassing pressure management. However, a certain logistic dilemma for deep gas sequestration into saline and thus electrically conductive aquifers is that crosswell magnetic-field measurements underperform in the imaging of more resistive plume bodies, further exacerbated when vertical arrays intersect, as opposed to surround, plumes. Furthermore, comparative synthetic-data plume imaging of such scenarios rates the information content of magnetic-field versus electric-field 3D crosswell layouts for reservoir and infrastructure conditions of a representative pilot site in a coastal area in Florida. The image quality of the resulting plume replications can be ranked numerically through a newly proposed semblance qualifier, appraising the model goodness of fit to a given reference. In contrast to common least-squares measures for goodness of fit, the semblance formulation uses classifying logistic function types, thus enabling a better distinction of predefined anomaly features.

58 GEOSCIENCES↗

Design of evaporator of spacelab refrigerator/freezer

An Evaporator has been designed for NASA-Johnson Space Center Life Sciences to conduct experiments in Spacelab mission SLS-1 using different samples such as blood, urine, human tissues etc. Two units will fly - one as a Refrigerator (4 C) and the other as a Freezer (-22 C). The evaporator tube is dip brazed on a grooved flat plate. Aluminum heat sink is dip brazed on the other side of the plate. Freon R5O2 is pumped through the tube and air is circulated over the finned surface to transfer heat. As freon 5O2 is considered toxic, the whole freon tube is covered with an evaporator cover to contain any freon leakage to avoid exposure to crew members. This containment is under vacuum and this pressure is monitored along with the freon pressure to determine freon leakage so that necessary steps can be taken to stop contamination of the spacelab air. An stress analysis has been done and it is found to have adequate safety margin to meet the requirements of NASA safety and reliability standards.

Hye, A.↗

Computational Tools and Workflows for Quantitative Risk Assessment and Decision Support for Geologic Carbon Storage Sites: Progress and Insights from the U.S. DOE’s National Risk Assessment Partnership

The 2005 Intergovernmental Panel on Climate Change (IPCC) Special Report on CCS raised the profile of CO2 capture and storage (CCS) as an important technology for reducing greenhouse gas (GHG) emissions. CCS is now recognized as a key component of most climate change mitigation scenarios. Since publication of that report the international research, development, and deployment (RD&D) community has advanced key technical aspects, clarified regulatory requirements, explored value chain and infrastructure solutions, and developed incentive paradigms to enable and promote large-scale deployment of CCS. These efforts have included research to better characterize geologic storage resources, to improve injection performance and storage efficiency, to assess and manage subsurface environmental risks, and to advance monitoring technologies to assure system conformance. These efforts have helped to build confidence in the viability of geologic carbon storage (GCS), but stakeholder concerns about long-term risks and liability associated with GCS remain a hurdle to broad acceptance and large-scale deployment of CCS. Since 2010, the U.S. DOE’s National Risk Assessment Partnership (NRAP) – a research collaboration between five contributing national laboratories – has worked to establish and demonstrate methods and tools to quantify and manage the subsurface environmental risks associated with GCS, amidst uncertainty. This work supports the Office of Fossil Energy and Carbon Management Carbon Transport and Storage Program’s goal of advancing safe and secure commercial-scale GCS deployment. To address the technical challenge of simulating the physical response of the GCS site to large-scale CO2 injection, NRAP has adopted an approach that relies on coupling computationally efficient reduced-order and/or data-driven proxy models of important system components (i.e., storage reservoir, sealing caprock, leakage pathways, intermediate formations, overlying groundwater aquifers, and the atmosphere) in integrated assessment framework. That integrated model of the physical system is complemented with fit-for purpose functionality to support site characterization and risk-related decisions. The recently released NRAP Phase II toolset includes the Open-Source Integrated Assessment Model (NRAP-Open-IAM) for evaluation of trends in leakage risk and potential impact, tools to support monitoring design optimization (Designs for Risk Evaluation and Management – DREAM v3.0 and Passive Seismic Monitoring Tool - PSMT), and tools for state of stress evaluation (State-of-Stress Analysis Tool - SOSAT) and forecasting induced seismicity risk. The NRAP team has also released a pair of reports describing conceptual workflows to incorporate physics-based, quantitative risk assessment into many of the design, planning, operation, and closure decisions for GCS projects. An online catalogue highlights published studies where these tools and methods are demonstrated. In this presentation, the utility of these products to assess risks and address key stakeholder questions will be highlighted through examples, and related insights about the safety and security of geologic carbon storage in qualified storage sites will be discussed. The prospect of rapid, large-scale deployment of GCS technology to aggressively reduce anthropogenic CO2 emissions requires careful consideration of interference between multiple commercial-scale storage projects within a basin. Going forward, NRAP is expanding and adapting site-scale risk quantification tools and methods to enable assessment of risks and inform management decisions for basin-scale deployment. Increasingly, this work will leverage next-generation approaches for surrogate modelling, fast prediction, and advanced visualization enabled by machine learning and artificial intelligence to promote virtual learning, scenario evaluation, and augment risk-based decision making.

quantitative risk assessment, geologic carbon stor↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗