Search NASA⌕ Search

SEARCH · Search NASA

Results for “lighting system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hierarchical Self‐Assembly of Multidimensional Functional Materials from Sequence‐Defined Peptoids

Abstract Hierarchical self‐assembly represents a powerful strategy for the fabrication of functional materials across various length scales. However, achieving precise formation of functional hierarchical assemblies remains a significant challenge and requires a profound understanding of molecular assembly interactions. In this study, we present a molecular‐level understanding of the hierarchical assembly of sequence‐defined peptoids into multidimensional functional materials, including twisted nanotube bundles serving as a highly efficient artificial light harvesting system. By employing synchrotron‐based powder X‐ray diffraction and analyzing single crystal structures of model compounds, we elucidated the molecular packing and mechanisms underlying the assembly of peptoids into multidimensional nanostructures. Our findings demonstrate that incorporating aromatic functional groups, such as tetraphenyl ethylene (TPE), at the termini of assembling peptoid sequences promotes the formation of twisted bundles of nanotubes and nanosheets, thus enabling the creation of a highly efficient artificial light harvesting system. This research exemplifies the potential of leveraging sequence‐defined synthetic polymers to translate microscopic molecular structures into macroscopic assemblies. It holds promise for the development of functional materials with precisely controlled hierarchical structures and designed functions.

Shao, Li↗

The IDEA detector concept for FCC-ee

A detector concept, named IDEA, optimized for the physics and running conditions at the FCC-ee is presented. After discussing the expected running conditions and the main physics drivers, a detailed description of the individual sub-detectors is given. These include: a very light tracking system with a powerful vertex detector inside a large drift chamber surrounded by a silicon wrapper, a high resolution dual readout crystal electromagnetic calorimeter, an HTS based superconducting solenoid, a dual readout fiber calorimeter and three layers of muon chambers embedded in the magnet flux return yoke. Some examples of the expected detector performance, based on fast and full simulation, are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of Energy Transport and Transduction in Photosynthetic Down-Conversion (Final Technical Report)

The research conducted under this contract focused on three areas related to control of energy transport and transduction in natural and synthetic light harvesting systems: (1) experimental and theoretical studies exploring the use of ultrafast laser pulse shaping to manipulate the initially excited states of multi-chromophore biological light harvesting networks and influence the early time energy transfer and electronic and vibrational relaxation pathways, (2) fundamental theoretical developments aimed at computing and analyzing the dynamics of excitations of complex heterogeneous environments and nano structures, and (3) joint experimental and theoretical design studies of artificial light harvesting materials exploring the influence of incorporating different types of organic layers in low dimensional lead halide perovskite materials on their hot carrier relaxation dynamics, and theoretical studies of the design of nano structured light harvesting antenna systems. These research projects supported the training of three theoretical and computational graduate students, one experimental graduate student, and one experimental post-doctoral researcher. The research has been published in seven peer reviewed papers and presented at several international meetings and workshops.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transverse orbital angular momentum and polarization entangled spatiotemporal structured light

Intra-system entanglement occurs between non-separable modes within the same system. For optical systems, the various degrees of freedom of light represent different modes, and the potential use of light to create higher dimensional classical entangle states offers a promising potential to drive new technological developments. In this work, we present experimental results demonstrating the orthogonality between transverse orbital angular momentum (t-OAM) of different spatiotemporal topological charges, a previously unverified property of t-OAM. Based on those results, we developed methods to create and characterize a novel family of t-OAM and polarization entangled spatiotemporal structured light. We further provide theoretical analysis to support our study of the entanglement between those modes. By demonstrating the feasibility of leveraging t-OAM as a new family of modes for classical entanglement, our work represents a new advancement towards higher dimensional classical entanglement strategies.

42 ENGINEERING↗

Direct determination of the temperatures of the Carbon targets at the CNI polarimeters in RHIC when hit by the proton beam

Up to now, the temperatures of the carbon fiber targets used in the RHIC CNI polarimeters during proton beam interactions cannot be directly measured, yet their survival indicates that they remain below the sublimation threshold of Tsub = 3915 K. This study investigates the feasibility of using light emission as a diagnostic tool to determine the target temperatures. A dedicated optical light collection system was implemented in IP12 to capture and analyze emitted light across the visible and near-infrared spectrum. This note focuses on the initial results from the RHIC run 24 and outlines the next steps for further investigation during run 25. A proposal for an APEX run [1] was submitted as an option in case a dedicated proton beam is not available during run 25. This work is critical for assessing the applicability of carbon fiber targets in the Electron-Ion Collider (EIC) under increased beam currents.

43 PARTICLE ACCELERATORS↗

Red-Light-Driven Biophotochemical Diode Based on a Microorganism–Silicon Nanowire Interface for Stable and Efficient Bias-Free CO 2 Reduction

Artificial photosynthesis offers a promising route for sustainable liquid fuel and feedstock production, yet integrating efficient CO 2 reduction catalysts with light-harvesting systems remains challenging. Here, in this study, we present a biophotochemical diode that couples microorganism-driven CO 2 reduction with glycerol oxidation, enabled by silicon nanowire photoelectrodes under varying red-light intensities. Tuning the biotic-abiotic interface─by increasing biocatalyst loading and adjusting the catholyte pH to mitigate local alkalization─significantly improves performance and stability. The enhanced-loading biocathode maintains a high faradaic efficiency across a wide potential range, even under elevated light intensities. At 60 mW/cm 2 , the system achieves a bias-free current density of 3.5 mA/cm 2 . Long-term stability testing at 40 mW/cm 2 demonstrates stable operation for over 100 h. The photoanode generates valuable C 3 products, primarily glycerate and lactate, enhancing the economic viability. This work showcases the importance of microenvironmental control at the biotic-abiotic interface and establishes a scalable platform for light-driven CO 2 reduction using earth-abundant silicon.

Artificial Photosynthesis↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

Dissipative Phase Transition in the Two-Photon Dicke Model

We explore the dissipative phase transition of the two-photon Dicke model, a topic that has garnered significant attention recently. Our analysis reveals that while single-photon loss does not stabilize the intrinsic instability in the model, the inclusion of two-photon loss restores stability, leading to the emergence of superradiant states, which coexist with the normal vacuum states. Using a second-order cumulant expansion for the photons, we derive an analytical description of the system in the thermodynamic limit, which agrees well with the exact calculation results. Additionally, we present the Wigner function for the system, shedding light on the breaking of the 𝑍4 symmetry inherent in the model. These findings offer valuable insights into stabilization mechanisms in open quantum systems and pave the way for exploring complex nonlinear dynamics in two-photon Dicke models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconductivity in the lightly doped Hubbard model on the cylindrical honeycomb lattice

Here, we have performed large-scale density-matrix renormalization group studies of the lightly doped Hubbard model on the honeycomb lattice on long three- and four-leg cylinders. We find that the ground state of the system upon lightly doping is consistent with that of a superconducting state with coexisting quasi-long-range superconducting and charge density wave orders. Both the superconducting and charge density wave correlations decay as a power law at long distances with corresponding exponents 𝐾 𝑠⁢𝑐 < 2 and 𝐾 𝑐 < 2. On the contrary, the spin-spin and single-particle correlations decay exponentially, although with relatively long correlation lengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physical and Operational Status of the Photovoltaic Systems in the Municipality of Pinotepa de Don Luis, Oaxaca, One Year after Their Installation [Estado fisico y operativo de los sistemas fotovoltaicos en el municipio de Pinotepa de Don Luis, Oaxaca un ano despues de su instalacion]

In November 1990, an inspection visit was made to the residential lighting photovoltaic systems that had been installed approximately one year before in the rural communities of the Municipality of Pinotepa de Don Luis, in the State of Oaxaca. The main purpose of the visit was to evaluate the physical and operational status of these systems. The systems typically consist of a photovoltaic module with a capacity of 30 or 35 Watts, an automotive type battery, an indicator of the status of charge of the battery, 3 fluorescent lamps and the corresponding installation, including cables, connection or outlet box and switches. It can be seen that the systems are in good physical condition and do not show any signs of intentionally caused damage. However, the incidence of failures is higher than what had been expected; therefore the operational status of these systems is considered to be below a level that could be accepted, with a tendency to getting worse. The main problem that has been detected is the lack of automatic charge controllers. This problem has caused other important failures. Serious deficiencies were appreciated in the installations, which show evidence of the poor workmanship of the installers. The lack of system standardization is evident, both regarding the components and the installation. As a consequence, there are technical factors which indicate that the installed systems will keep deteriorating at a rate faster than normal, and will stop operating in a short time unless urgent preventive and corrective measures are taken. The attitude of the users with respect to the systems is generally positive. However, there are elements that make the correct operation and maintenance of these systems a very difficult task. The users did not receive any training regarding the best way to operate and take care of their systems, nor any other information in relation to their technical limitations.

14 SOLAR ENERGY↗

Characterization of the X-ARAPUCA Systems' Response for SBND's Light Detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, as well as characterizing the behavior of the baseline artifact. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [U. Illinois, Chicago]↗

Characterization of the X-ARAPUCA systems' response for SBND's light detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, which was able to be accomplished. The behavior of the baseline artifact was also characterized, which appeared only at high voltages/bright events, and separates further from the prompt peak as the voltage/brightness increases. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [Fermilab]↗

Dataset describing two reference models for full-spectral lighting and daylight simulations together with implementations for two software systems

A dataset of two spectral lighting simulation reference models - one office and one factory hall - is presented. It aims to demonstrate and support full-spectral daylight and electric lighting simulations and facilitate evaluation of non-visual effects of light. The dataset includes Rhino CAD geometry, comprehensive spectral material and light source data and window system BSDF data. Example implementations in the two software tools, Radiance and OWL, enable reproducible workflows and support adoption in other software. The dataset is openly available on Zenodo. The office model reproduces Room 518 at the University of Innsbruck, including a west-facing façade and interior furnishings. The factory hall model follows the proposed geometry in the European standard 15193 for building energy performance. Interior reflectances in the office were measured in-situ using a handheld spectrometer. Exterior spectra and factory hall materials matching specified reflectances were obtained from an online spectral materials database. Glazing transmittance was derived from IGDB data using LBNL Optics/WINDOW. BSDFs for venetian blinds at various tilt angles, and for a diffusing pane adapted from the Complex Glazing Database, were generated in WINDOW. Luminaires in both models are specified with photometric files (Eulumdat/IES) and lamp spectra (Fluorescent 840, 4000 K LED). The provided example implementations (Radiance, OWL) include prepared input data and scripts to run first spectral simulations; example results are also included. The dataset is prepared to support reuse by researchers, designers and software developers for method validation, software engineering and comparison, and development of spectral metrics and controls.

Geisler-Moroder, David↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2025 Intern Poster

The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

Volumetric imaging of the 3D orientation of cellular structures with a polarized fluorescence light-sheet microscope

Polarized fluorescence microscopy is a valuable tool for measuring molecular orientations in biological samples, but techniques for recovering three-dimensional orientations and positions of fluorescent ensembles are limited. We report a polarized dual-view light-sheet system for determining the diffraction-limited three-dimensional distribution of the orientations and positions of ensembles of fluorescent dipoles that label biological structures. We share a set of visualization, histogram, and profiling tools for interpreting these positions and orientations. We model the distributions based on the polarization-dependent efficiency of excitation and detection of emitted fluorescence, using coarse-grained representations we call orientation distribution functions (ODFs). We apply ODFs to create physics-informed models of image formation with spatio-angular point-spread and transfer functions. We use theory and experiment to conclude that light-sheet tilting is a necessary part of our design for recovering all three-dimensional orientations. We use our system to extend known two-dimensional results to three dimensions in FM1-43-labeled giant unilamellar vesicles, fast-scarlet-labeled cellulose in xylem cells, and phalloidin-labeled actin in U2OS cells. Additionally, we observe phalloidin-labeled actin in mouse fibroblasts grown on grids of labeled nanowires and identify correlations between local actin alignment and global cell-scale orientation, indicating cellular coordination across length scales.

Science & Technology - Other Topics↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗