Search NASA⌕ Search

SEARCH · Search NASA

Results for “load analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles

This paper provides new regression models for demand reduction of Demand Response programs for the purpose of ex ante evaluation of the programs and screening for recruiting customer enrollment into the programs. The proposed regression models employ load sensitivity to outside air temperature and representative load pattern derived from cluster analysis of customer baseline load as explanatory variables. The proposed models examined their performances from the viewpoint of validity of explanatory variables and fitness of regressions, using actual load profile data of Pacific Gas and Electric Company's commercial and industrial customers who participated in the 2008 Critical Peak Pricing program including Manual and Automated Demand Response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Following Analysis of the Holos-Quad 10MWe Micro-Reactor with Plant Dynamics Code

This report presents the load following analysis of the “Holos-Quad” 10MWe micro-reactor design developed by HolosGen LLC. This analysis is focused on the Holos-Quad micro-reactor ability to match the changing grid demand at 10%/min rate. The control mechanisms for the plant are identified, simulated, and compared. Based on the comparison results, control strategy for load following of the Holos-Quad micro-reactor is developed. The control strategy and load following capabilities are demonstrated in a full-range down-and-up reactor power transient from 100% to 0% and back to 100% load at 10%/min rate. All calculations are carried out with Argonne’s Plant Dynamics Code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Structural Analysis Results of Thermal, Operating and Seismic Analysis for Hanford Single-Shell Tank Integrity - 12261

Since Hanford's 149 Single-Shell Tanks (SSTs) are well beyond their design life, the U.S. Department of Energy has commissioned a state of the art engineering analysis to assess the structural integrity of the tanks to ensure that they are fit for service during the cleanup and closure phase. The structural integrity analysis has several challenging factors. There are four different tank sizes in various configurations that require analysis. Within each tank type there are different waste level and temperature histories, soil overburden depths, tank floor arrangements, riser sizes and locations, and other on-tank structures that need to be addressed. Furthermore, soil properties vary throughout the tank farms. This paper describes the structural integrity analysis that was performed for the SSTs using finite element models that incorporate the detailed design features of each tank type. The analysis was performed with two different models: an ANSYS static model for the Thermal and Operating Loads Analysis, and an ANSYS dynamic model for the seismic analysis. The TOLA analyses simulate the waste level and thermal history and it included a matrix of analysis cases that bounded the material property uncertainties. The TOLA also predicts the occurrence of concrete thermal degradations and cracking, reinforcement yielding, and soil plasticity. The seismic analysis matrix included uncertainty in waste properties, waste height and the soil modulus. In seismic analysis the tank concrete was modeled as a linear elastic material that was adjusted for the present day degraded conditions. Also, the soil was treated as a linear elastic material while special modeling techniques were used to avoid soil arching and achieve proper soil pressure on the tank walls. Seismic time histories in both the horizontal and vertical directions were applied to the seismic model. Structural demands from both Thermal and Operating Loads Analysis and seismic models were extracted in the form of section forces and moments for sections throughout the tank under the appropriate load combinations. These demands were evaluated against the American Concrete Institute (ACI) code requirements for nuclear safety-related concrete structures as defined in ACI-349-06. Structural integrity analysis of Hanford's Type II and Type III Single-Shell Tanks (SSTs) was performed using finite element models (ANSYS software) that incorporate the detailed design features of each tank type. The analysis was performed with two different models: a static model for the Thermal and Operating Loads Analysis, and a dynamic model for the seismic analysis. Structural demands from both Thermal and Operating Loads Analysis and seismic models were evaluated against the American Concrete Institute (ACI) code requirements for nuclear safety-related concrete structures as defined in ACI-349-06. The ratio of demand to capacity (D/C) was reported as a measure of structural integrity for the applicable ACI-349-06 load combinations. Although the Type II and Type III analysis matrix showed varying demands depending on the material combinations, all of the tank regions that are critical to structural stability passed the ACI 349-06 acceptance criteria. This was true for the conservative combination of maximum recorded thermal loads and maximum soil overburden depth combined with the analysis matrix of bounding material property combinations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytic analysis of load alignment for coning extreme‐scale rotors

Abstract Extreme‐scale wind turbines (rated powers greater than 10 MW) with large rotor diameters and conventional upwind designs must resist extreme downwind and gravity loads. This can lead to significant structural design challenges and high blade masses that can impede the reduction of levelized cost of wind energy. Herein, the theoretical basis for downwind load alignment is developed. This alignment can be addressed with active downwind coning to reduce/eliminate flapwise bending loads by balancing the transverse components of thrust, centrifugal, and gravitational force. Equations are developed herein that estimates the optimal coning angle that reduces flapwise loads by a specified amount. This analysis is then applied to a 13.2‐MW scale with 100‐m‐level wind turbine blades, where it is found that a load alignment coning schedule can substantially reduce the root flapwise bending moments. This moment reduction in this example can allow the rotor mass to be decreased significantly when compared with a conventional upwind three‐bladed rotor while maintaining structural performance and annual energy output.

Noyes, Carlos↗

Autonomous plug and play electric vehicle charging scenarios including reactive power provision: a probabilistic load flow analysis

Electric vehicle (EV) charging can have various impacts on low‐voltage distribution systems, along with increasing the uncertainty of network load levels. One method for capturing the statistical uncertainty is probabilistic load flow (PLF). A primary concern of such an approach is determining the correlation between the input variables. Since data are limited, a 1 min resolution bottom‐up time‐variant load model, capturing the changing voltage dependencies of the load, is used for modelling household electrical demand to provide pseudo‐meter data for the three‐phase PLF analysis of a residential distribution network. The correlation between the household and EV charging loads are implicitly taken into account by modelling the EV plug‐in and departure times with the corresponding occupancy model. Two autonomous plug‐and‐play charging scenarios are compared with a standard charging arrangement at both unity and 0.95 capacitive power factors. Four different PLF input correlation scenarios, varying from fully correlated to fully independent, are considered. The proposed charging scenarios and reactive power provision reduce the likelihood of system voltage violations introduced by EVs. The PLF results are verified against those from the initial time‐series analysis providing valuable insight into the uncertainty introduced by EVs and the correlation between household and EV loads.

Melhorn, Alexander C.↗

Load Decomposition Analysis Tool

This project tests the application of Bennet Meyers' signal decomposition to the residential end-use load decomposition problem.

Chassin, David P.↗

Detecting and Blocking Network Attacks at Ultra High Speeds

Stateful, in-depth, in-line traffic analysis for intrusion detection and prevention has grown increasingly more difficult as the data rates of modern networks rise. One point in the design space for high-performance network analysis - pursued by a number of commercial products - is the use of sophisticated custom hardware. For very high-speed processing, such systems often cast the entire analysis process in ASICs. This project pursued a different architectural approach, which we term Shunting. Shunting marries a conceptually quite simple hardware device with an Intrusion Prevention System (IPS) running on commodity PC hardware. The overall design goal is was to keep the hardware both cheap and readily scalable to future higher speeds, yet also retain the unparalleled flexibility that running the main IPS analysis in a full general-computing environment provides. The Shunting architecture we developed uses a simple in-line hardware element that maintains several large state tables indexed by packet header fields, including IP/TCP flags, source and destination IP addresses, and connection tuples. The tables yield decision values the element makes on a packet-by-packet basis: forward the packet, drop it, or divert ('shunt') it through the IPS (the default). By manipulating table entries, the IPS can, on a fine-grained basis: (i) specify the traffic it wishes to examine, (ii) directly block malicious traffic, and (iii) 'cut through' traffic streams once it has had an opportunity to 'vet' them, or (iv) skip over large items within a stream before proceeding to further analyze it. For the Shunting architecture to yield benefits, it needs to operate in an environment for which the monitored network traffic has the property that - after proper vetting - much of it can be safely skipped. This property does not universally hold. For example, if a bank needs to examine all Web traffic involving its servers for regulatory compliance, then a monitor in front of one of the bank's server farms cannot safely omit a subset of the traffic from analysis. In this environment, Shunting cannot realize its main performance benefits, and the monitoring task likely calls for using custom hardware instead. However, in many other environments we find Shunting holds promise for delivering major performance gains. This arises due to the the widely documented 'heavy tail' nature of most forms of network traffic, which we might express as 'a few of the connections carry just about all the bytes.' The key additional insight is '... and very often for these few large connections, the very beginning of the connection contains nearly all the information of interest from a security analysis perspective.' We argue that this second claim holds because it is at the beginning of connections that authentication exchanges occur, data or file names and types are specified, request and reply status codes conveyed, and encryption is negotiated. Once these occur, we have seen most of the interesting facets of the dialog. Certainly the remainder of the connection might also yield some grist for analysis, but this is generally less likely, and thus if we want to lower analysis load at as small a loss as possible of information relevant to security analysis, we might best do so by skipping the bulk of large connections. In a different context, the 'Time Machine' work by Kornexl and colleagues likewise shows that in some environments we can realize major reductions in the volume of network traffic processed, by limiting the processing to the first 10-20 KB of each connection. As a concrete example, consider an IPS that monitors SSH traffic. When a new SSH connection arrives and the Shunt fails to find an entry for it in any of its tables (per-address, per-port, per-connection), it executes the default action of diverting the connection through the IPS. The IPS analyzes the beginning of the connection in this fashion. As long as it is satisified with the dialog, it reinjects the packets forwarded to it so that the connection can continue. If the connection successfully negotiates encryption, the IPS can no longer profitably analyze it, so it downloads a per-connection table entry to the Shunt specifying that the action for the connection in the future is 'forward.' For heavy-tailed connections, this means a very large majority of the connection's packets will now pass through the Shunt device without burdening the IPS with any further analysis load. On the other hand, if the IPS is dissatisfied with some element of the initial dialog, it downloads a 'drop' entry to terminate the connection. Note that by providing for reinjection, we can promote an intrusion detection system into an intrusion prevention system, one that does not merely detect attacks but can block them before they complete. Reinjection also allows the IPS to normalize traffic to remove ambiguities that attackers can leverage to evade the IPS.

99 GENERAL AND MISCELLANEOUS↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.

decomposition↗

Load Flexibility Analysis of Residential HVAC and Water Heating and Commercial Refrigeration

The emergence of connected devices and the Internet of Things has opened the door to the concept of widespread use of building equipment for load-side flexibility. This stems from the increased use of distributed and clean energy resources for electric generation and the growing demand for a more resilient and reliable grid. A significant challenge associated with the use of building equipment as a distributed energy resource is quantifying the magnitude of power or energy flexibility. Unlike batteries that have well-defined and relatively constant capacity and maximum charge/discharge rates, building equipment often has characteristics that vary based on external factors (e.g., weather or occupant behavior). This makes quantifying the availability and flexibility of these resources difficult. Controlling a fleet of equipment while minimizing any adverse impacts to the occupants (e.g., discomfort or food spoilage) is a nontrivial matter. Although there are many different control methodologies available, this study focuses on two: priority-based control (PBC) and model-predictive control (MPC). These were selected because they represent two ends of the control spectrum. PBC is a relatively simple control strategy that requires only the current state of the devices to be controlled and an estimate of how much power each device consumes when turned on. MPC is much more complex and requires a model of the system and forecasts of any disturbances that influence the system. Because MPC has a predictive element, it can prepare for a desired response before the event and therefore is expected to provide a more optimal control relative to PBC. Both MPC and PBC are compared with a baseline simulation that uses feedback control typical of the thermostatically controlled devices being evaluated. This report investigates the load flexibility of three building systems: residential air conditioners, residential water heaters, and commercial refrigeration. Air heating and cooling and water heating account for 45% of residential electricity use, making them good candidates for providing load flexibility. Refrigeration in commercial buildings accounts for 16% of commercial building electricity use, making it another good candidate. Simplified models of each system were generated and validated based on measured data from actual equipment. These models were used to simulate the thermal and power response of the systems using PBC and MPC for a fleet of devices trying to achieve a variety of different responses, including hourly load shed, hourly load up, and daily peak demand reduction. Significant findings from each piece of equipment follow.

42 ENGINEERING↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

FAST Modularization Framework for Wind Turbine Simulation: Full-System Linearization: Preprint

The wind engineering community relies on multiphysics engineering software to run nonlinear time-domain simulations e.g. for design-standards-based loads analysis. Although most physics involved in wind energy are nonlinear, linearization of the underlying nonlinear system equations is often advantageous to understand the system response and exploit well-established methods and tools for analyzing linear systems. This paper presents the development and verification of the new linearization functionality of the open-source engineering tool FAST v8 for land-based wind turbines, as well as the concepts and mathematical background needed to understand and apply it correctly.

17 WIND ENERGY↗

Sensitivity analysis of the effect of wind characteristics and turbine properties on wind turbine loads

Proper wind turbine design relies on the ability to accurately predict ultimate and fatigue loads of turbines. The load analysis process requires precise knowledge of the expected wind-inflow conditions as well as turbine structural and aerodynamic properties. However, uncertainty in most parameters is inevitable. It is therefore important to understand the impact such uncertainties have on the resulting loads. The goal of this work is to assess which input parameters have the greatest influence on turbine power, fatigue loads, and ultimate loads during normal turbine operation. An elementary effects sensitivity analysis is performed to identify the most sensitive parameters. Separate case studies are performed on (1) wind-inflow conditions and (2) turbine structural and aerodynamic properties, both cases using the National Renewable Energy Laboratory 5 MW baseline wind turbine. The Veers model was used to generate synthetic International Electrotechnical Commission (IEC) Kaimal turbulence spectrum inflow. The focus is on individual parameter sensitivity, though interactions between parameters are considered. The results of this work show that for wind-inflow conditions, turbulence in the primary wind direction and shear are the most sensitive parameters for turbine loads, which is expected. Secondary parameters of importance are identified as veer, u -direction integral length, and u components of the IEC coherence model, as well as the exponent. For the turbine properties, the most sensitive parameters are yaw misalignment and outboard lift coefficient distribution; secondary parameters of importance are inboard lift distribution, blade-twist distribution, and blade mass imbalance. This information can be used to help establish uncertainty bars around the predictions of engineering models during validation efforts, and provide insight to probabilistic design methods and site-suitability analyses.

17 WIND ENERGY↗