Search NASA⌕ Search

SEARCH · Search NASA

Results for “load pattern modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Procedure for Tooth Contact Analysis of a Face Gear Meshing With a Spur Gear Using Finite Element Analysis

A procedure was developed to perform tooth contact analysis between a face gear meshing with a spur pinion using finite element analysis. The face gear surface points from a previous analysis were used to create a connected tooth solid model without gaps or overlaps. The face gear surface points were used to create a five tooth face gear Patran model (with rim) using Patran PCL commands. These commands were saved in a series of session files suitable for Patran input. A four tooth spur gear that meshes with the face gear was designed and constructed with Patran PCL commands. These commands were also saved in a session files suitable for Patran input. The orientation of the spur gear required for meshing with the face gear was determined. The required rotations and translations are described and built into the session file for the spur gear. The Abaqus commands for three-dimensional meshing were determined and verified for a simplified model containing one spur tooth and one face gear tooth. The boundary conditions, loads, and weak spring constraints were determined to make the simplified model work. The load steps and load increments to establish contact and obtain a realistic load was determined for the simplified two tooth model. Contact patterns give some insight into required mesh density. Building the two gears in two different local coordinate systems and rotating the local coordinate systems was verified as an easy way to roll the gearset through mesh. Due to limitation of swap space, disk space and time constraints of the summer period, the larger model was not completed.

Bibel, George↗

IAEA CRP on HTGR UAM: Propagation of Phase I cross section uncertainties to Phase II neutronics steady state using SCALE/SAMPLER and PHISICS/RELAP5-3D

The IAEA Coordinated Research Project (CRP) on High Temperature Gas Cooled Reactor (HTGR) Uncertainties in Modeling (UAM) has been actively supported by the HTGR Methods group at Idaho National Laboratory since 2013. The INL team is responsible for the development of the prismatic reactor design exercises, based on the 350 MW General Atomics Modular HTGR (MHTGR). The focus of this paper is the reporting of the INL results obtained for the propagation of the lattice cross section uncertainties to the stand-alone neutronics simulation of the full MHTGR-350 core. For the nominal (i.e. best-estimate) model, a series of fresh and depleted single block and super cell SCALE/KENO and SCALE/NEWT models were developed at INL to assess spectral effects in the MHTGR-350, and a combination of these lattice cells were used to construct 8-group cross section libraries for use in the INL-developed PHISICS/RELAP5-3D code suite. The block-level homogenized libraries were assigned to the 220 fuel zones utilized in the MHTGR-350 PHISICS core model, according to the fresh and mixed fresh/depleted core loading pattern. A set of 1,000 perturbed NEWT lattice and PHISICS/RELAP5-3D core calculations were performed using the stochastic sampling module SAMPLER in SCALE 6.2. The paper discusses the mean and standard deviation values obtained for the eigenvalue, power offset and peak axial power density uncertainty results for this sequence of 1,000 lattice-to-core MHTGR-350 simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prediction of reinforcement corrosion using corrosion induced cracks width in corroded reinforced concrete beams

This paper studies the evolution of reinforcement corrosion in comparison to corrosion crack width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the beam were drawn and steel reinforcement was recovered from the beam to observe the corrosion pattern and to measure the loss of mass of steel reinforcement. Maximum steel cross-section loss of the main reinforcement and average steel cross-section loss between stirrups were plotted against the crack width. The experimental results were compared with existing models proposed by Rodriguez et al., Vidal et al. and Zhang et al. Time prediction models for a given opening threshold are also compared to experimental results. Steel cross-section loss for stirrups was also measured and was plotted against the crack width. It was observed that steel cross-section loss in the stirrups had no relationship with the crack width of longitudinal corrosion cracks. -- Highlights: •Relationship between crack and corrosion of reinforcement was investigated. •Corrosion results of natural process and then corresponds to in-situ conditions. •Comparison with time predicting model is provided. •Prediction of load-bearing capacity from crack pattern was studied.

36 MATERIALS SCIENCE↗

Assessing plasma face component thermal response to rotating 3D magnetic fields for SPARC tokamak

Thermal response simulations of plasma-facing components (PFCs) in the SPARC tokamak, performed with the HEAT code, show that three-dimensional (3D) heat loads resulting from stationary n=1 perturbations require highly radiative scenarios, with up to 95% of the power crossing the separatrix (P SOL ) being radiated, to maintain PFC temperatures within acceptable operational limits, whereas the application of slowly rotating 3D fields substantially reduces the thermal loads. The HEAT module, developed to predict heat loads from non-axisymmetric plasmas, is extended to model time-dependent heat flux patterns generated by rotating 3D fields, and a comprehensive thermal analysis is performed on PFCs subjected to both the maximum and minimum power loads, as well as to rotating heat flux distributions, to evaluate the temperature evolution for varying perturbation amplitudes and rotation frequencies. The extension of this analysis to 3D fields with toroidal mode number n=2 shows that this configuration leads to weaker localized heat flux peaks relative to the n=1 case, enabling safe operation with less than 80% of the power radiated when static 3D fields of low amplitude are applied, while using slowly rotating fields at higher amplitudes. These results indicate that n=2 perturbations are generally less detrimental to divertor power exhaust, emphasizing the strong dependence of divertor power exhaust on the characteristics of the applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The analysis of reactively loaded microstrip antennas by finite difference time domain modelling

In recent years, much interest has been shown in the use of printed circuit antennas in mobile satellite and communications terminals at microwave frequencies. Although such antennas have many advantages in weight and profile size over more conventional reflector/horn configurations, they do, however, suffer from an inherently narrow bandwidth. A way of optimizing the bandwidth of such antennas by an electronic tuning technique using a loaded probe mounted within the antenna structure is examined, and the resulting far-field radiation patterns are shown. Simulation results from a 2D finite difference time domain (FDTD) model for a rectangular microstrip antenna loaded with shorting pins are given and compared to results obtained with an actual antenna. It is hoped that this work will result in a design package for the analysis of microstrip patch antenna elements.

Hilton, G. S.↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

Tectonics of planetary loading - A general model and results

The tectonics of planetary loading is investigated using an analytical model for determining the stresses in an arbitrarily thick spherical shell due to an idealized axisymmetric load. The model includes the flat plate and thin shell membrane approximations as end members, and makes it possible to determine the nature of the transition between them. Using this model, the stress states and the resulting tectonic patterns due to an idealized exponential load are determined as functions of five dimensionless parameters: the ratio of the lithospheric thickness to the planetary radius; the decay width of the load; the 'support parameter', which is the ratio of the buoyancy to the flexural support; the angular distance from the load center; and the normalized radial distance from the planet center.

Janes, D. M.↗

Modeling Electric Vehicle Charging Load Using Origin-Destination Data

The accelerating adoption of electric vehicles (EVs) poses challenges to the power grid, necessitating precise representation of mobility patterns for effective infrastructure upgrades. Traditional simulation-based charging demand estimation faces limitations in generating trip chains reflective of actual travel patterns without complex network modeling. Hence, an innovative agent-based trip chain generation model is introduced to overcome these challenges. Drawing from the National Household Travel Survey (NHTS) and the NextGen NHTS origin-destination add-on data for Clarke County, Georgia, this study proposes a simulation method capturing both temporal and spatial mobility patterns without relying on extensive network topology data. The resulting trip chains predict EV charging load at the Census Block Group level, validated with a 1.03 correlation to actual trip counts, affirming their reflective accuracy. Two charging scenarios, residential-only and charging-everywhere, reveal distinct demand profiles. The charging-everywhere scenario aligns closely with the trip profile, while the residential-only scenario exhibits an afternoon peak slightly surpassing the former. This study contributes a data-driven charging demand estimation methodology, offering critical insights for grid resiliency planning amid the evolving landscape of EV adoption.

Pan, Melrose↗

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Spatial and Temporal Structures on the Surface of Solids under Load

A model and a method are proposed to explain the origin and main specific features of the dynamic patterns of different types, which were previously observed on the free surface of solids under load in experiments. It is shown that the pattern is formed due to the dynamic instability of the flat surface of the solid under load. This instability develops at the relaxation mechanism caused by the dynamic atomic displacements due to a change in the interatomic interaction during the electron-density redistribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demo Abstract: Toward Data-driven Demand-Response Optimization in a Campus Microgrid

We describe and demonstrate a prototype software architecture to support data-driven demand response optimization (DR) in the USC campus microgrid, as part of the Los Angeles Smart Grid Demonstration Project. The architecture includes a semantic information repository that integrates diverse data sources to support DR, demand forecasting using scalable machine-learned models, and detection of load curtailment opportunities by matching complex event patterns.

Amam, Saima↗

Study of effect of PWR cold leg temperature gradient on reactor core condition

Effects of temperature and flow gradients in Westinghouse designed three-loop Pressurized Water Reactor (PWR) cold legs, the piping between the main coolant pump and the reactor vessel, were evaluated using Computational Fluid Dynamics (CFD) code STAR CCM+ and coupled neutronic and thermal-hydraulic (T/H) code system VERA. In the parametric study, several symmetric and asymmetric temperature gradients that were significantly larger than those observed from plant measurements were applied to the cold leg inlets for comparison with the base case without any temperature gradient. A CFD model using the STAR-CCM+ code was developed for a portion of the RCS region between the Reactor Coolant Pump (RCP) and the core inlet based on previously validated modeling approach. The CFD simulation results were processed for the temperature and flow rate distributions at the core inlet as input to the VERA calculations. The VERA code system consists of COBRA-TF (CTF) for thermal-hydraulics, MPACT for reactor physics and neutron transport, and ORIGEN for isotopic depletion. The VERA model was for depletion calculations of a high-burnup loading pattern with the reactor core in pin-by-pin and subchannel resolution. The results of the study indicate that the postulated temperature gradients within the PWR cold legs do not result in any significant changes in the core inlet temperature distributions and the core power distributions during the reactor operation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An engineering model of woven composites based on micromechanics

Composites with three-dimensional woven architectures exhibit large strains to failure when compared to composites made up of the same materials but not with three-dimensional interlocking tows. The fracture mechanics of such three-dimensional architectures is a subject requiring substantial investigation and experimental testing. Classical fracture mechanics concepts (for instance, an isolated defect in a homogeneous body) will not be applicable to the woven fracture test specimen. The use of an isolated singularity to characterize an entire specimen is inadequate when the density of defects is considerable and the material is heterogeneous. Modelling of such a complex system requires a great deal of insight and consideration as well as prudent choices of model sizes to make numerical schemes feasible. The purpose of this manuscript is to review our recently acquired knowledge of damage accumulation in woven composites and to describe a practicable model of the macroscopic behavior in these and other complex composite architectures based on such knowledge. In this manuscript, discussion will be limited to uniaxial compressive loading; considerations of general loading (monotonic and cyclic) will appear in a subsequent manuscript. Our modelling efforts may be briefly described as follows: the composite is subdivided into microstructural elements (microelements) in which the micromechanical modelling is either understood rigorously or can be represented adequately by statistical parameters. There can be microstructural elements for many different types of composite components, such as the various types of warp and weft and matrix for three-dimensional woven composites. The physical dimensions of microelements are made as large as possible while the response within the element can still be represented by a single micromechatlical calculation. The various elements are linked together(sometimes by associating distinct corners and edges, sometimes by superposition) in a pattern which resembles a particular weave architecture. The model can then be loaded in any manner and the linear and nonlinear elastic responses of representative weaves can be calculated. After the elastic regime, the fracture response is determined by monitoring the damage accumulation.

Carter, W. C.↗

Prefabricated High-Strength Rebar Systems with High-Performance Concrete for Accelerated Construction of Nuclear Concrete Structures

This project aimed to reduce the field construction times and fabrication costs of reinforced concrete (RC) nuclear structures through the use of: 1) high-strength steel deformed reinforcing bar (rebar); 2) prefabricated high-strength rebar (HSR) assemblies with headed anchorages; and 3) high-strength concrete (HSC). The focus of the project was not to develop new innovations on materials, but rather to fill a major knowledge gap on the effectiveness, code conformity, and viability (i.e., practicality, commercial availability) of existing high-strength materials in nuclear structures, especially in shear walls, their connections/joints, and around penetrations. These advances promote the Nuclear Energy Enabling Technologies Advanced Methods for Manufacturing (NEET-1) goals of accelerating deployment schedules by at least 6 months and reducing component fabrication costs by 20% or more. Toward this vision, the following objectives were identified and completed: Develop limit-benefit and cost-benefit analysis frameworks: The structural and economic limits and benefits of HSR and HSC in nuclear walls were evaluated. Importantly, it was found that modest increases in concrete strength up to 10.0 ksi and rebar yield strength up to 100 ksi result in the most economic designs and improved structural performance (Barbachyn et al., 2017a and Barbachyn et al., 2017b). Also, an industry survey was distributed to determine the cost benefits associated with prefabrication. Importantly, on-site worker-hours are significantly reduced, allowing for significantly accelerated construction schedules (Devine et al. 2018b). Develop an optimization methodology for structural design: An optimization study was deemed not necessary since the trivial solution with maximized use of high-strength materials and prefabrication always resulted in the largest cost and time savings. Instead, the benefits (and limits) of high-strength materials and prefabrication on construction costs and on-site construction time were investigated through a parametric study. Cost-reductions through the use of HSR and HSC were found to be greater than 40%. Also, on-site construction time of nuclear shear walls can be reduced by up to 83% through the use of prefabricated rebar assemblies. Conduct experimental evaluations of nuclear shear walls and wall-foundation joints: A large scale experimental program was completed on shear-critical RC cantilever deep beams. From these experiments, it was demonstrated that increasing rebar yield strength had a greater effect on increasing lateral strength than increasing the concrete compressive strength. Further, using HSR together with HSC resulted in the highest lateral strength and displacement ductility (Devine et al. 2018a). Additionally, large-scale reversed-cyclic lateral load tests were conducted on RC shear walls. It was demonstrated that through the utilization of HSR and HSC, a wall with 55% reduced vertical and horizontal rebar area was able to achieve 91% of the peak lateral strength of a conventional wall using state-of-practice materials with the same geometry. Further, trim reinforcement with headed anchorages around the penetrations proved to be effective. Develop validated numerical simulation models: Numerical modeling was completed in two phases during this project using 3 different finite element software packages. The first phase used existing measured data from previous experimental studies on stocky RC walls to validate simplified predictive models. Models using two different programs were validated based on a database of 38 stocky walls (Barbachyn et al., 2017a). The second phase occurred after experimental testing using a third and more detailed finite element package. Prediction improvements for the initial stiffness, lateral deformations, damage propagation, and failure mechanisms were targeted. The resulting detailed models more accurately predicted the peak lateral strength, initial and secant stiffnesses, lateral deformations, and cracking patterns of the wall test specimens subjected to reversed-cyclic lateral loading as compared to the simplified pretest models. Develop validated design procedures, tools, and criteria: This project evaluated the accuracy of existing closed-form design equations from U.S. building design standards and previous research (Barbachyn et al. 2017a and Devine et al. 2018a). It was shown that the current predictive equations for shear strength capacity need to be revisited as they provide significant scatter and gross overestimates, indicating the potential for unconservative designs. Further, for both the deep beam and shear wall specimens, the numerical models and flexural capacity predictions provided the most accurate strength predictions. Develop cost-effective field construction procedures: To promote the use of prefabricated rebar assemblies, the following construction conditions where prefabrication would be used instead of in-place rebar tying were identified from an industry survey: 1) to save on construction schedule; 2) to improve safety and/or quality control; 3) for areas with heavy rebar congestion; and 4) for structures with significant repetition in rebar layout. All of these conditions directly apply and benefit nuclear construction where construction costs and schedules are extensive, safety and quality are of utmost importance, the reinforcement is extremely dense, and the reinforcement layout is repetitive in many regions of the shear walls. Additionally, an experimental study was conducted to investigate the changes in bar spacing (with respect to code-required rebar spacing and placement tolerances) when a horizontally assembled prefabricated two-dimensional (2D) rebar mat or three-dimensional (3D) rebar cage is lifted (or tripped) to a vertical position. It was found that the bars involved in both the lateral translation of the rebar assemblies (i.e., movement of the assembly in its horizontal position) and the tripping process were most susceptible to large spacing changes, and thus, their positions within the assembly would need to be checked after the placement of the assembly in place within the formwork. Importantly, the spacings of all of the other bars in the assembly were not affected significantly by the lateral translation and tripping process, thereby eliminating the need to recheck their positions within the assembly (Devine et al. 2018b).

36 MATERIALS SCIENCE↗

Integral Full Core Multi-Physics PWR Benchmark with Measured Data

In recent years, the importance of modeling and simulation has been highlighted extensively in the DOE research portfolio with concrete examples in nuclear engineering with the CASL and NEAMS programs. These research efforts and similar efforts worldwide aim at the development of high-fidelity multi-physics analysis tools for the simulation of current and next-generation nuclear power reactors. Like all analysis tools, verification and validation is essential to guarantee proper functioning of the software and methods employed. The current approach relies mainly on the validation of single physic phenomena (e.g. critical experiment, flow loops, etc.) and there is a lack of relevant multiphysics benchmark measurements that are necessary to validate high-fidelity methods being developed today. This work introduces a new multi-cycle full-core Pressurized Water Reactor (PWR) depletion benchmark based on two operational cycles of a commercial nuclear power plant that provides a detailed description of fuel assemblies, burnable absorbers, in-core fission detectors, core loading and re-loading patterns. This benchmark enables analysts to develop extremely detailed reactor core models that can be used for testing and validation of coupled neutron transport, thermal-hydraulics, and fuel isotopic depletion. The benchmark also provides measured reactor data for Hot Zero Power (HZP) physics tests, boron letdown curves, and three-dimensional in-core flux maps from 58 instrumented assemblies. The benchmark description is now available online and has been used by many groups. However, much work remains to be done on the quantification of uncertainties and modeling sensitivities. This work aims to address these deficiencies and make this benchmark a true non-proprietary international benchmark for the validation of high-fidelity tools. This report details the BEAVRS uncertainty quantification for the first two cycle of operations and serves as the final report of the project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Load-deflection tests and computer analyses of a high-precision adhesive-bonded antenna reflector panel

New adhesive-bonded panels are being investigated as a part of an effort to extend and upgrade the 64-m to a 70-m antenna network. Load-deflection tests were conducted on a sample high-precision adhesive-bonded panel for comparison with design criteria. Two computerized structural models were developed in order to predict the deformation patterns under different types of distributed and concentrated loadings. The main purpose was to obtain empirical stiffness factors for the slit beams and girders in the panel structure. With determination and use of the empirical stiffness factors, there is a good agreement between the theoretically predicted deflections and the test measurements. It was also found that the new bonded panels satisfy the stringent design specifications and surface tolerance bounds.

Chian, C. T.↗

ATTNChecker: Highly-Optimized Fault Tolerant Attention for Large Language Model Training

Large Language Models (LLMs) have demonstrated remarkable performance in various natural language processing tasks. However, the training of these models is computationally intensive and susceptible to faults, particularly in the attention mechanism, which is a critical component of transformer-based LLMs. In this paper, we investigate the impact of faults on LLM training, focusing on INF, NaN, and near-INF values in the computation results with systematic fault injection experiments. We observe the propagation patterns of these errors, which can trigger non-trainable states in the model and disrupt training, forcing the procedure to load from checkpoints. To mitigate the impact of these faults, we propose ATTNChecker, the first Algorithm-Based Fault Tolerance (ABFT) technique tailored for the attention mechanism in LLMs. ATTNChecker is designed based on fault propagation patterns of LLM and incorporates performance optimization to adapt to both system reliability and model vulnerability while providing lightweight protection for fast LLM training. Evaluations on four LLMs show that ATTNChecker on average incurs on average 7% overhead on training while detecting and correcting all extreme errors. Compared with the state-of-the-art checkpoint/restore approach, ATTNChecker reduces recovery overhead by up to 49×.

Liang, Yuhang [University of Alabama - Birmingham]↗