Search NASA⌕ Search

SEARCH · Search NASA

Results for “lost circulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Potosi Reservoir Model 2013c, Property Modeling Update

As part of a larger project co-funded by the United States Department of Energy (US DOE) to evaluate the potential of formations within the Cambro-Ordovician strata above the Mt. Simon as potential targets for carbon sequestration in the Illinois and Michigan Basins, the Illinois Clean Coal Institute (ICCI) requested Schlumberger to evaluate the potential injectivity and carbon dioxide (CO2) plume size of the Cambrian Potosi Formation. The evaluation of this formation was accomplished using wireline data, core data, pressure data, and seismic data from this project as well as two other separately funded projects: the US DOE-funded Illinois Basin–Decatur Project (IBDP) being conducted by the Midwest Geological Sequestration Consortium (MGSC) in Macon County, Illinois, and the Illinois Industrial Carbon Capture and Sequestration (ICCS) project funded through the American Recovery and Reinvestment Act. In 2010, technical performance evaluations on the Cambrian Potosi Formation were performed through reservoir modeling. The data included formation tops from mud logs, well logs from the Verification Well #1 (VW1) and the Injection Well (CCS1), structural and stratigraphic formation from three dimensional (3D) seismic data, and field data from several waste water injection wells for Potosi Formation. The intention was for 2.2 million tons per annum (2 million tonnes per annum [MTPA]) of CO2 to be injected for 20 years. In the Task Error! Reference source not found., the 2010 Potosi heterogeneous model (referred to as the "Potosi Dynamic Model 2010") was re-run using a new injection scenario of 3.5 million tons per annum (3.2 MTPA) for 30 years. The extent of the Potosi Dynamic Model 2010, however, appeared too small for the new injection target. The models size was insufficient to accommodate the evolution of the plume. The new model, Potosi Dynamic Model 2013a, was built by extending the Potosi Dynamic Model 2010 grid to 30 by 30 mi (48 by 48 km), while preserving all property modeling workflows and layering. This model was retained as the base case. In the preceding Task [1], the Potosi reservoir model was updated to take into account the new data from the Verification Well #2 (VW2) which was drilled in 2012. The porosity and permeability modeling was revised to take into account the log data from the new well. Revisions of the 2010 modeling assumptions were also done on relative permeability, capillary pressures, formation water salinity, and the maximum allowable well bottomhole pressure. Dynamic simulations were run using the injection target of 3.5 million tons per annum (3.2 MTPA) for 30 years. This dynamic model was named Potosi Dynamic Model 2013b. In this Task, a new property modeling workflow was applied, where seismic inversion data guided the porosity mapping and geobody extraction. The static reservoir model was fully guided by PorosityCube interpretations and derivations coupled with petrophysical logs from three wells. The two main assumptions are: porosity features in the PorosityCube that correlate with lost circulation zones represent vugular zones, and that these vugular zones are laterally continuous. Extrapolation was done carefully to populate the vugular facies and their corresponding properties outside the seismic footprint up to the boundary of the 30 by 30 mi (48 by 48 km) model. Dynamic simulations were also run using the injection target of 3.5 million tons per annum (3.2 MTPA) for 30 years. This new dynamic model was named Potosi Dynamic Model 2013c. Reservoir simulation with the latest model gives a cumulative injection of 43 million tons (39 MT) in 30 years with a single well, which corresponds to 40% of the injection target. The injection rate is approx. 3.2 MTPA in the first six months as the well is injecting into the surrounding vugs, and declines rapidly to 1.8 million tons per annum (1.6 MTPA) in year 3 once the surrounding vugs are full and the CO2 start to reach the matrix. After, the injection rate declines gradually to 1.2 million tons per annum (1.1 MTPA) in year 18 and stays constant. This implies that a minimum of three (3) wells could be required in the Potosi to reach the injection target. The injectivity evaluated in this Task was higher compared to the preceding Task, since the current facies modeling (guided by the porosity map from the seismic inversion) indicated a higher density of vugs within the vugular zones. 5 As the CO2 follows the paths where vugs interconnection exists, a reasonably large and irregular plume extent was created. After 30 years of injection, the plume extends 13.7 mi (22 km) in E-W and 9.7 mi (16 km) in N-S directions. After injection finishes, the plume continues to migrate laterally, mainly driven by the remaining pressure gradient. After 60 years post-injection, the plume extends 14.2 mi (22.8 km) in E-W and 10 mi (16 km) in N-S directions, and remains constant as the remaining pressure gradient has become very low. Should the targeted cumulative injection of 106 million tons (96 MT) be achieved; a much larger plume extent could be expected. The increase of reservoir pressure at the end of injection is approximately 1,200 psia (8,274 kPa) around the injector and gradually decreases away from the well. The reservoir pressure increase is less than 10 psia (69 kPa) beyond 14 mi (23 km) away from injector. Should the targeted cumulative injection of 106 million tons (96 MT) be achieved; a much larger areal pressure increase could be expected. The reservoir pressure declines rapidly during the first 30 years post injection and the initial reservoir pressure is nearly restored after 100 years post-injection. The present evaluation is mainly associated with uncertainty on the vugs permeability and interconnectivity. The use of porosity mapping from seismic inversion might have reduced the uncertainty on the lateral vugs body distributions. However, major uncertainties on the Potosi vugs permeability remains. Therefore, injection test and pressure interference test among the wells could be considered to evaluate the local vugs permeability, extent, and interconnectivity. Facies modeling within the Potosi has yet to be thoroughly addressed. The carbonates during the time of deposition are believed to be regionally extensive. However, it may be worth delineating the reservoir with other regional wells or modern day analogues to understand the extent of the Potosi. More specifically, the model could incorporate lateral changes or trends if deemed necessary to represent facies transition. Data acquisitions to characterize the fracture pressure gradient, the formation water properties, the relative permeability, and the capillary pressure could also be considered in order to allow a more rigorous evaluation of the Potosi storage performance. A simulation using several injectors could also be considered to determine the required number of wells and appropriate spacing to achieve the injection target while taking into account the pressure interference.

Adushita, Yasmin↗

Super Hot EGS and the Newberry Deep Drilling Project

A productive geothermal well drilled into super-hot rock (SHR) with a temperature above 400°C will produce super-critical fluid. At a flow rate of 60 kg/s, a SHR well could produce 50 MWe compared to 5-7 MWe for the same flow at 200°C. Even though these deeper, super-hot wells will cost more, the high energy density means power produced by engineered geothermal systems (EGS) can meet the market ($46 MW-hr) by directly tapping the heat source. We propose a proof of concept where hot rock is close to the surface (~5 km), and the cost of drilling and EGS stimulation will be lowest. A suitable, ready-to-go SHR site is on Newberry Volcano, Oregon, one of the largest geothermal heat reservoirs in the USA, extensively studied for the last 40 years. Millions of dollars have already been invested in the site by private geothermal developers and the US Department of Energy (DOE), resulting in a ready-to-use facility with the necessary infrastructure, environmental permits, land commitments, and monitoring plans. The Newberry Deep Drilling Project (NDDP) will be located at an idle geothermal exploration well, NWG 46-16, drilled in 2008, 3500 m deep and 320°C at bottom, which will be deepened another 1000 to 1300 m to reach 500 °C. The original well was drilled with few lost circulation zones and the temperature profile indicates conductive heat flow. Compared to other SHR projects world-wide, this well would return more materials (cuttings, core and fluids) with more predictable drilling conditions, thus providing a suite of data near and across the brittle-ductile transition in silicarich rocks. After drilling, a hydraulic well stimulation will both change the pore pressure in fractures and cool the fracture walls resulting in permeability enhancement through both thermal fracturing, and hydro-shearing. The first step for the NDDP was an International Continental Drilling Program (ICDP) sponsored workshop held at the OSU-Cascades campus in Bend from Sept. 10-14, 2017. The workshop concluded by setting ambitious goals for NDDP: 1) test EGS above the critical point of water, 2) collect samples of rocks within the brittle-ductile transition, 3) investigate volcanic hazards, 4) study magmatic geomechanics, 5) calibrate geophysical imaging techniques, and 6) test technology for drilling, well completion, and geophysical monitoring in a very high temperature environment. The second step, completed January 15, 2018, was submitting a proposal to ICDP for 46-16 deepening. The next steps will be to continue building a team with project, technology, and investment partners to make NDDP a reality.

EGS, Geothermal, Newberry↗

Wabash CarbonSAFE Subtask 7.1 – Pre-drilling Site Assessment Topical Report: DOE-FE0031626-1

The Wabash CarbonSAFE project will drill a stratigraphic test well at the Wabash Valley Resources facility near Terre Haute, Indiana. Lithologic, geomechanical, and geophysical data collected from samples testing and an extensive geophysical logging suite will be used to determine the feasibility for the geologic sequestration of 50 million metric tons or more of injected carbon dioxide. The primary target reservoir and caprock to be investigated for the Wabash CarbonSAFE project are the Mt. Simon Sandstone and Eau Claire Shale, respectively. The project team has assessed the planned Wabash #1 drilling site using subsurface geologic data and analyses from both Illinois and Indiana. These data were used to generate geologic structure and isopach thickness maps for target reservoir and caprock layers which were incorporated into a detailed discussion of the nature of the Illinois Basin’s Cambro-Ordovician carbon dioxide storage complex at the drilling site. Formation tops were prognosed for 19 lithologic units to aid drilling and coring procedures. Additional GIS analysis indicates that no known structural features will negatively impact the target storage reservoir or caprock, nor will protected and sensitive areas, groundwater resources, or existing resource development be negatively affected by Wabash #1 drilling activities. The Wabash #1 Geologic/Structure Test well drilling permit was awarded by Indiana Department of Natural Resources (IN-DNR) – Division of Oil and Gas on November 12th, 2019, and the well is expected to be drilled to a total depth of approximately 8,350 feet. Potential impacts on drilling progress include abandoned underground coal mines which mined the Springfield and Survant coals until 1964 and 1954, respectively, and a lost circulation zone in the Potosi Dolomite, which has been demonstrated to have intermittent cavernous porosity from karstification. This document also details the coring and sampling program, proposed logging suite, and well testing program, all of which will be dynamically reviewed as drilling progresses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Toward Super Hot EGS: The Newberry Deep Drilling Project

Newberry Volcano in Central Oregon is an extensively studied volcano that contains one of the largest geothermal heat reservoirs in the western United States. The detailed characterization of this continental volcanic system reveals it is an excellent choice for drilling a well that will reach temperatures greater than 450°C at relatively shallow depths (< 5000 m). The main purpose of the Newberry Deep Drilling Project (NDDP) is to test the feasibility of super-hot EGS where super critical fluid can be produced with a higher energy compared to conventional EGS. NDDP will be located at an idle geothermal exploration well, NWG 46-16, drilled in 2008 on the western flank of the volcano. The project has several main goals: test EGS above the critical point of water; collect samples of rocks within the brittle-ductile transition zone; investigate volcanic hazards; study geomechanics in plastic rock and test technology for drilling, well completion, and geophysical monitoring. The well NWG 46-16, now 3500 m deep and 340-374°C at bottom, will be deepened another 1000 to 1300 m to reach 500°C into the supercritical region, and potentially approaching the brittle-ductile transition or even zones of partial melt. The original well was drilled with lost circulation zones only at very shallow depth and the temperature profile indicates conductive heat flow. Compared to other super-hot geothermal projects worldwide, this well would return more materials (cuttings, core and fluids) with more predictable drilling conditions, thus providing a suite of data near and across the brittle-ductile transition in silica-rich rocks. The well will be completed with casing and cement designed and tested to withstand the abuses of thermal cycling, hydraulic and thermal stimulation, and flow of supercritical fluids. Geothermal, volcanic, geophysical, and engineering information gained will be widely applicable to other magmatically active areas throughout the Pacific Rim and beyond.

EGS, supercritical, Newberry Volcano, brittle-duct↗

Expanding thermite reactions for downhole applications

Methods and apparatus for forming platforms and flow control features in underground wells is described, using modified thermite reactions to form a ceramic plug in place. The reactive package is engineered to expand laterally, filling the well, and may be used to form a ceramic bridge plug, porous ceramic screen sections, or mitigate lost circulation of drilling fluids. These objectives are achieved through the design of the reactive package and through use of carefully chosen reaction additives that control the molten product rheology, solidification temperature, and pore generations and sustainment.

Lowry, William Edward↗

Mixed Convection in the VHTR in the Event of a LOFA

The US Department of Energy, Office of Nuclear Energy (DOE-NE) is supporting the development of a very high temperature reactor (VHTR) concept as the primary focus of it next generation nuclear power plant (NGNP) program. The VHTR is cooled by forcing helium downwards through the core into the lower plenum and out the hot duct. In the event that the coolant circulators are lost, the driving pressure drop across the core will reduce to zero and there will be the opportunity for natural circulation to occur. During the time that the circulators are powering down, the heat transfer in the core from the graphite blocks to the helium coolant will transform from turbulent forced convection to mixed convection, where buoyancy effects become important, to free or natural convection, where buoyancy is dominant. Analysis of the nature of the forced, mixed and free convection is best done using computational fluid dynamic (CFD) software that can provide fine details of the flow and heat transfer. However, CFD analysis involves approximations in the results because of the finite nature of the spatial and temporal discretizations required, the inexact nature of the turbulence models that are used and the finite precision of the computers employed. Therefore, it is necessary to validate the CFD computations. Validation is accomplished by comparing results from specific CFD computations to experimental data that have been taken specifically for the purpose of validation and that are related to the physical phenomena in question. The present report examines the flow and heat transfer parameters (dimensionless numbers) that characterize the flow and reports ranges for their values based on specific CFD studies performed for the VHTR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MODELING STRATEGIES TO COMPUTE NATURAL CIRCULATION USING CFD IN A VHTR AFTER A LOFA

A prismatic gas-cooled very high temperature reactor (VHTR) is being developed under the next generation nuclear plant program (NGNP) of the U.S. Department of Energy, Office of Nuclear Energy. In the design of the prismatic VHTR, hexagonal shaped graphite blocks are drilled to allow insertion of fuel pins, made of compacted TRISO fuel particles, and coolant channels for the helium coolant. One of the concerns for the reactor design is the effects of a loss of flow accident (LOFA) where the coolant circulators are lost for some reason, causing a loss of forced coolant flow through the core. In such an event, it is desired to know what happens to the (reduced) heat still being generated in the core and if it represents a problem for the fuel compacts, the graphite core or the reactor vessel (RV) walls. One of the mechanisms for the transport of heat out of the core is by the natural circulation of the coolant, which is still present. That is, how much heat may be transported by natural circulation through the core and upwards to the top of the upper plenum? It is beyond current capability for a computational fluid dynamic (CFD) analysis to perform a calculation on the whole RV with a sufficiently refined mesh to examine the full potential of natural circulation in the vessel. The present paper reports the investigation of several strategies to model the flow and heat transfer in the RV. It is found that it is necessary to employ representative geometries of the core to estimate the heat transfer. However, by taking advantage of global and local symmetries, a detailed estimate of the strength of the resulting natural circulation and the level of heat transfer to the top of the upper plenum is obtained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Relationship of Loss, Mean Age of Air and the Distribution of CFCs to Stratospheric Circulation and Implications for Atmospheric Lifetimes

Man-made molecules called chlorofluorcarbons (CFCs) are broken apart in the stratosphere by high energy light, and the reactive chlorine gases that come from them cause the ozone hole. Since the ozone layer stops high energy light from reaching low altitudes, CFCs must be transported to high altitudes to be broken apart. The number of molecules per volume (the density) is much smaller at high altitudes than near the surface, and CFC molecules have a very small chance of reaching that altitude in any particular year. Many tons of CFCs were put into the atmosphere during the end of the last century, and it will take many years for all of them to be destroyed. Each CFC has an atmospheric lifetime that depends on the amount of energy required to break them apart. Two of the gases that were made the most are CFC13 and CF2C12. It takes more energy to break apart CF2C12 than CFC13, and its lifetime is about 100 years, nearly twice as long as the lifetime for CFC13. It is hard to figure out the lifetimes from surface measurements because we don't know exactly how much was released into the air each year. Atmospheric models are used to predict what will happen to ozone and other gases as the CFCs decrease and other gases like C02 continue to increase during the next century. CFC lifetimes are used to predict future concentrations and all assessment models use the predicted future concentrations. The models have different circulations and the amount of CFC lost according to the model may not match the loss that is expected according to the lifetime. In models the amount destroyed per year depends on how fast the model pushes air into the stratosphere and how much goes to high altitudes each year. This paper looks at the way the model circulation changes the lifetimes, and looks at measurements that tell us which model is more realistic. Some models do a good job reproducing the age-of-air, which tells us that these models are circulating the stratospheric air at the right speed. These same models also do a good job reproducing the amount of CFCs in the lower atmosphere where they were measured by instruments on NASA's ER-2, a research plane that flies in the lower stratosphere. The lifetime for CFC13 that is calculated using the models that do the best job matching the data is about 25% longer than most people thought. This paper shows that using these measurements to decide which models are more realistic helps us understand why their predictions are different from each other and also to decide which predictions are more likely.

Douglass, A. R.↗

Intracore Natural Circulation Study in the High Temperature Test Facility

The development of the Modular High-Temperature Gas-Cooled Reactor is a significant milestone in advanced nuclear reactor technology. One of the concerns for the reactor’s safe operation is the effects of a loss-of-flow accident (LOFA) where the coolant circulators are tripped, and forced coolant flow through the core is lost. Depending on the steam generator placement, loop or intracore natural circulation develops to help transfer heat from the core to the reactor cavity, cooling system. This paper investigates the fundamental physical phenomena associated with intracore coolant natural circulation flow in a one-sixth Computational Fluid Dynamics (CFD) model of the Oregon State University High Temperature Test Facility (OSU HTTF) following a loss-of-flow accident transient. This study employs conjugate heat transfer and steady-state flow along with an SST k-ω turbulence model to characterize the phenomenon of core channel-to-channel natural convection. Previous studies have revealed the importance of complex flow distribution in the inlet and outlet plenums with the potential to generate hot coolant jets. For this reason, complete upper and lower plenum volumes are included in the analyzed computational domain. CFD results also include parametric studies performed for a mesh sensitivity analysis, generated using the STAR-CCM+ software. The resulting channel axial velocities and flow directions support the test facility scaling analysis and similarity group distortions calculation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of the Yukon River on the Bering Sea

The distribution of near-surface, turbid water, discharged by the Yukon River, was studied based on analysis of satellite imagery. The interannual analyses indicates that the net flow of near-surface, turbid water is northward of the delta across the entrance to Norton Sound. Only turbid water to the east enters Norton Sound and consists of 25% of the total area. Approximately 10% of the water circulates into the sound along the southern coast and is lost to view in the vicinity of Unalakleet. Suspended sediments transported by this southern circulation are primarily deposited along the southern coast. Three distinct zones within the turbid water were identified based on relative brightness levels. These zones appear to be primarily related to differences in suspended-sediment concentrations and position of the sediments in the water column. The extent of turbid water varies seasonally. It is most extensive June through October even though discharge of the Yukon River decreases substantially after July.

Dean, K.↗

Body composition changes in men and women after 2-3 weeks of bed rest

Several parameters of body composition were measured in eight men before and after 14 days of continuous recumbency, and in eight women before and after 17 days of recumbency. The parameters measured included body weight, body water, body potassium, plasma volume, and plasma protein concentrations. From these, values were derived for body fat content, lean body mass, body mass, and circulating plasma proteins. In general, the men and women responded similarly to continuous recumbency. Characteristically, there was significant reduction of plasma volume and body potassium in both groups. The women showed a significant reduction in circulating plasma protein, entirely in the albumin fraction; a similar change was observed in the men. The women, but not the men, showed a significant increase in circulating fibrinogen. Both men and women lost body cell mass, while body fat content remained the same or tended to increase slightly. It is expected that similar changes would occur in weightlessness. It is further concluded that women should tolerate the weightlessness of space flight physiologically as well as men.

Pace, N.↗

The Flow of Plasmaspheric Plasma in the Inner Magnetosphere: An Introduction to a Subtopic and the Methodology

The spatial and temporal variation of plasmaspheric mass throughout the inner magnetosphere as a function of changing geomagnetic and solar wind conditions is a consequence of its transport throughout the system. It is proposed that the global measurement of 30.4 -nm EUV emission from plasmaspheric He+ can be used to derive the mass transport pathways, as well as the dynamic conditions and locations of when specific pathways are active. This is to be accomplished using observations obtained by the Extreme Ultraviolet Instrument (EUV) on the Imager for Magnetopause -to-Aurora Global Exploration Mission (IMAGE). Questions to be addressed by this approach include evaluation of whether plasmaspheric transport fully accounts for the plasma lost through erosion a nd plume formation, through inward compression of the plasmapause, or by plasma redistributed back into the ionosphere? Does plasmaspheric erosion begin near 3h MLT, sweeping plasma dawnward and duskward as some report? Can the mass in a persistent plume be accounted for by continued loss from within the body of the plasmasphere or must the ionosphere be an active source? These questions are part of the broader unresolved morphology of the global circulation of plasmaspheric plasma through the magnetosphere to be lost into the solar wind, recirculated, or returned to the ionosphere. An initial demonstrations of the methodology and corresponding results will be presented.

Gallagher, D. L.↗

Redesigned Human Metabolic Simulator

A design has been formulated for a proposed improved version of an apparatus that simulates atmospheric effects of human respiration by introducing controlled amounts of carbon dioxide, water vapor, and heat into the air. Denoted a human metabolic simulator (HMS), the apparatus is used for testing life-support equipment when human test subjects are not available. The prior version of the HMS, to be replaced, was designed to simulate the respiratory effects of as many as four persons. It exploits the catalytic combustion of methyl acetate, for which the respiratory quotient (the molar ratio of carbon dioxide produced to oxygen consumed) is very close to the human respiratory quotient of about 0.86. The design of the improved HMS provides for simulation of the respiratory effects of as many as eight persons at various levels of activity. The design would also increase safety by eliminating the use of combustion. The improved HMS (see figure) would include a computer that would exert overall control. The computer would calculate the required amounts of oxygen removal, carbon dioxide addition, water addition, and heat addition by use of empirical equations for metabolic profiles of respiration and heat. A blower would circulate air between the HMS and a chamber containing a life-support system to be tested. With the help of feedback from a mass flowmeter, the blower speed would be adjusted to regulate the rate of flow according to the number of persons to be simulated and to a temperature-regulation requirement (the air temperature would indirectly depend on the rate of flow, among other parameters). Oxygen would be removed from the circulating air by means of a commercially available molecular sieve configured as an oxygen concentrator. Oxygen, argon, and trace amounts of nitrogen would pass through a bed in the molecular sieve while carbon dioxide, the majority of nitrogen, and other trace gases would be trapped by the bed and subsequently returned to the chamber. If, as recommended, the oxygen concentrator were of a rotating twelve-bed design, then variations in the product stream could be made very small. Carbon dioxide would be added directly to the circulating air by simple injection from a supply tank. The rate of injection would be maintained at the required rate by use of a mass flowmeter/controller. In the same way, nitrogen would be added to make up for the small amount of nitrogen lost through the oxygen concentrator. Water vapor would be added to the circulating air by heating the corresponding required flow of water to steam in a heat exchanger. More heat, required to complete the simulation of the thermal effect of respiration, would be added through another heat exchanger. Heat would be supplied to both heat exchangers via a hot-oil loop.

Duffield, Bruce↗

Wind Streaks on Venus: Clues to Atmospheric Circulation

Magellan images reveal surface features on Venus attributed to wind processes. Sand dunes, wind-sculpted hills, and more than 5830 wind streaks have been identified. The streaks serve as local "wind vanes," representing wind direction at the time of streak formation and allowing the first global mapping of near-surface wind patterns on Venus. Wind streaks are oriented both toward the equator and toward the west. When streaks associated with local transient events, such as impact cratering, are deleted, the westward component is mostly lost but the equatorward component remains. This pattern is consistent with a Hadley circulation of the lower atmosphere.

Greeley, Ronald↗

Acciona Power Plant Hydrogen Mitigation Project

In 2014, Acciona Solar Power and the National Renewable Energy Laboratory initiated discussions to identify a method to solve a long-standing efficiency loss problem at parabolic trough power plants. Parabolic trough power plants begin to show lost thermal efficiency after six years of operation, due to the presence of trace concentrations of hydrogen in the heat transfer fluid that circulates in the power plant. Trace levels of hydrogen infiltrate the collector field receivers, increasing their heat loss, and decreasing the power plants’ thermal efficiency. At the time, Acciona’s Nevada Solar One power plant in Boulder City, Nevada was starting to show this efficiency loss. After several discussions, APS and NREL agreed to a collaborative effort (CRADA) to develop and implement a method to reduce hydrogen levels in the circulating HTF at the NSO power plant. The project was planned as a three-year effort, and work started in June 2015. The CRADA’s goal was to solve the long-standing lost efficiency problem caused by the buildup of hydrogen in the HTF, which significantly impacts the efficiency, electricity generation, and revenue from parabolic trough power plants.

08 HYDROGEN↗

Scalp Cooler

Composite Consulation Concepts, Inc.'s Chemo-cooler, a scalp cooling system based on NASA space suit technology, prevents hair loss in patients undergoing chemotherapy. A head covering is placed over plastic tubing through which cold water is circulated from a cylinder. A controller monitors time and temperature. With chemo-cooler, 63% of patients lost almost no hair; 9% suffered only moderate hair loss. The technique was commercialized by an ex-NASA employee.

Source record↗

Predictability of the 1997 and 1998 South Asian Summer Monsoons

The predictability of the 1997 and 1998 south Asian summer monsoon winds is examined from an ensemble of 10 Atmospheric General Circulation Model (AGCM) simulations with prescribed sea surface temperatures (SSTs) and soil moisture, The simulations are started in September 1996 so that they have lost all memory of the atmospheric initial conditions for the periods of interest. The model simulations show that the 1998 monsoon is considerably more predictable than the 1997 monsoon. During May and June of 1998 the predictability of the low-level wind anomalies is largely associated with a local response to anomalously warm Indian Ocean SSTs. Predictability increases late in the season (July and August) as a result of the strengthening of the anomalous Walker circulation and the associated development of easterly low level wind anomalies that extend westward across India and the Arabian Sea. During these months the model is also the most skillful with the observations showing a similar late-season westward extension of the easterly CD wind anomalies. The model shows little predictability or skill in the low level winds over southeast Asia during, 1997. Predictable wind anomalies do occur over the western Indian Ocean and Indonesia, however, over the Indian Ocean they are a response to SST anomalies that were wind driven and they show no skill. The reduced predictability in the low level winds during 1997 appears to be the result of a weaker (compared with 1998) simulated anomalous Walker circulation, while the reduced skill is associated with pronounced intraseasonal activity that is not well captured by the model. Remarkably, the model does produce an ensemble mean Madden-Julian Oscillation (MJO) response that is approximately in phase with (though weaker than) the observed MJ0 anomalies. This is consistent with the idea that SST coupling may play an important role in the MJO.

Schubert, Siegfred D.↗