Search NASA⌕ Search

SEARCH · Search NASA

Results for “low refractive index”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High Refractive Index Adhesives for Laser Glass Cladding Applications (ABBREVIATED Report)

To eliminate parasitic light oscillations (amplified spontaneous emission (ASE)), high energy laser systems often utilize polymeric materials to adhere optically absorptive cladding materials to laser gain media (glass or crystal). Most of these polymeric optical adhesives are index matched to lower index gain media, and there was no capability to achieve refractive indices (RI) greater than 1.60 with low color, while also maintaining mechanical compliance to serve as adhesives for cladding applications. The completion of LDRD 23-FS-043 shows we can chemically develop novel suitable adhesive candidates with refractive indices above 1.64 at 532 nm while also exhibiting Shore A hardness between 50-90, with high optical clarity, low color, and minimal haze for films ~1-2 mm thick (84 %Transmission at 532 nm). This will enable us to begin mapping a process space to allow future customizable adhesive formulations for building a variety of laser systems with tunable refractive index matching for various gain and cladding media.

36 MATERIALS SCIENCE↗

Structural Phase Transitions between Layered Indium Selenide for Integrated Photonic Memory

The primary mechanism of optical memoristive devices relies on phase transitions between amorphous and crystalline states. The slow or energy-hungry amorphous–crystalline transitions in optical phase-change materials are detrimental to the scalability and performance of devices. Leveraging an integrated photonic platform, nonvolatile and reversible switching between two layered structures of indium selenide (In 2 Se 3 ) triggered by a single nanosecond pulse is demonstrated. The high-resolution pair distribution function reveals the detailed atomistic transition pathways between the layered structures. With interlayer “shear glide” and isosymmetric phase transition, switching between the α- and β-structural states contains low re-configurational entropy, allowing reversible switching between layered structures. Broadband refractive index contrast, optical transparency, and volumetric effect in the crystalline–crystalline phase transition are experimentally characterized in molecular-beam-epitaxy-grown thin films and compared to ab initio calculations. Finally, the nonlinear resonator transmission spectra measure of incremental linear loss rate of 3.3 GHz, introduced by a 1.5 µm-long In 2 Se 3 -covered layer, resulted from the combinations of material absorption and scattering.

36 MATERIALS SCIENCE↗

Casimir force, causality, and the Gurzhi model

An extended Drude model, termed the Gurzhi model, which takes into account the electron-phonon and electron-electron interactions, is applied to calculate the Casimir force between two metallic plates. It is shown that although the dielectric permittivity of the Gurzhi model has a first-order pole in the upper half-plane of complex frequencies and, thus, violates the causality principle, it can be used in a restricted frequency interval in combination with the experimental permittivity determined by the optical data for the complex index of refraction. The imaginary part of the Gurzhi dielectric permittivity of Au at low frequencies demonstrates better agreement with the permittivity given by the optical data than the simple Drude model. The Casimir pressure between two Au plates is computed using the Gurzhi, Drude, and plasma model approaches, taking into account the optical data, as well as with the simple Drude and plasma models. Finally, the contribution of the electron-electron scattering to the Casimir pressure is estimated. Although a comparison with the measurement data of two precise experiments shows that the Gurzhi model does not resolve the Casimir puzzle, the obtained results suggest further clarification of this fundamental problem.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Engineering cellular metabolism for targeted biosynthesis can require extensive design-build-test-learn (DBTL) cycles as the engineer works around the cell's survival requirements. Alternatively, carrying out DBTL cycles in cell-free environments can accelerate this process and alleviate concerns with host compatibility. A promising approach to cell-free metabolic engineering (CFME) leverages metabolically active crude cell extracts as platforms for biomanufacturing and for rapidly discovering and prototyping modified proteins and pathways. Realizing these capabilities and optimizing CFME performance requires methods to characterize the metabolome of lysate-based cell-free platforms. That is, analytical tools are necessary for monitoring improvements in targeted metabolite conversions and in elucidating alterations to metabolite flux when manipulating lysate metabolism. In this work, metabolite analyses using high-performance liquid chromatography (HPLC) coupled with either optical or mass spectrometric detection were applied to characterize metabolite production and flux in E. coli S30 lysates. Specifically, this report describes the preparation of samples from CFME lysates for HPLC analyses using refractive index detection (RID) to quantify the generation of central metabolic intermediates and by-products in the conversion of low-cost substrates (i.e., glucose) to various high-value products. The analysis of metabolite conversion in CFME reactions fed with 13 C-labeled glucose through reversed-phase liquid chromatography coupled to tandem mass spectrometry (MS/MS), a powerful tool for characterizing specific metabolite yields and lysate metabolic flux from starting materials, is also presented. Altogether, applying these analytical methods to CFME lysate metabolism enables the advancement of these systems as alternative platforms for executing faster or novel metabolic engineering tasks.

59 BASIC BIOLOGICAL SCIENCES↗

Low Index Contrast Valley Hall Topological Photonics for Robust Transport in the Visible Spectrum

We report topological photonics is an emerging platform to study light-matter interactions with promising features such as robust edge state transmission that could be advantageous for quantum information applications. However, applying common topological photonic designs for visible wavelength light-matter interactions is challenging because materials compatible with the visible spectrum have lower refractive index contrasts. We design and demonstrate a novel valley Hall topological photonic crystal that can support a complete topological band gap in the visible spectrum. We also show an overetch procedure can be used to reduce the leakage loss common for low index contrast materials. To demonstrate these advantages, we fabricate topological photonic devices following these design principles and show that edge states at energies in the complete band gap have robust transmission around sharp corners. The compatibility of this photonic structure with straightforward fabrication methods will facilitate the study of interactions between topologically nontrivial photons and nanomaterials active in the visible spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Biomass-Based Fuels and Fuel Blends for Low-Emissions, Advanced Compression Ignition Engines (Final Report)

The goal of the Co-Optima program was to accelerate deployment of co-optimized fuels and engines that will reduce fuel consumption, and criterion pollutants and greenhouse gas (GHG) emissions for both spark and compression-ignited engines. In this project, combustion measurements from a constant pressure flow rig (CPFR) with optical access were used to assess fundamental combustion behavior of number of different candidate fuels and fuel blends. This chamber and its peripheral systems allowed stable control of ambient air pressure and temperature and fuel injection pressure and timing for hundreds of repeat injections allowing statistical interpretation of the results. The optical diagnostics enabled capturing of liquid length, vapor length, ignition timing, lift-off length as well as localized (temporal and spatially resolved) mixture refractive index, flame structure, and soot mass. The operating conditions allowed the study of combustion conditions promoting lean lifted flame combustion (LLFC), a mixing-controlled low-temperature combustion (LTC) strategy to reduce soot production in Advanced Compression Ignition (ACI) engines.

09 BIOMASS FUELS↗

Multiphoton and Harmonic Imaging of Microarchitected Materials

Microadditive manufacturing has revolutionized the production of complex, nano- to microscale components across various fields. This work investigates two-photon (2P) and three-photon (3P) fluorescence imaging, as well as third-harmonic generation (THG) microscopy, to examine periodic microarchitected lattice structures fabricated using multiphoton lithography (MPL). By immersing the structures in refractive index matching fluids, we demonstrate high-fidelity 3D reconstructions of both fluorescent structures using 2P and 3P microscopy as well as low-fluorescence structures using THG microscopy. These results show that multiphoton fluorescence (MPF) imaging offers reduced signal decay with respect to depth compared to single-photon techniques in the examined structures. We further demonstrate the ability to nondestructively identify intentional internal modifications of the structure that are not immediately visible with scanning electron microscope (SEM) images and compression-induced fractures, highlighting the potential of these techniques for quality control and defect detection in microadditively manufactured components.

36 MATERIALS SCIENCE↗

Giant Modulation of Refractive Index from Picoscale Atomic Displacements

Abstract It is shown that structural disorder—in the form of anisotropic, picoscale atomic displacements—modulates the refractive index tensor and results in the giant optical anisotropy observed in BaTiS 3 , a quasi‐1D hexagonal chalcogenide. Single‐crystal X‐ray diffraction studies reveal the presence of antipolar displacements of Ti atoms within adjacent TiS 6 chains along the c ‐axis, and threefold degenerate Ti displacements in the a – b plane. 47/49 Ti solid‐state NMR provides additional evidence for those Ti displacements in the form of a three‐horned NMR lineshape resulting from a low symmetry local environment around Ti atoms. Scanning transmission electron microscopy is used to directly observe the globally disordered Ti a–b plane displacements and find them to be ordered locally over a few unit cells. First‐principles calculations show that the Ti a – b plane displacements selectively reduce the refractive index along the ab ‐plane, while having minimal impact on the refractive index along the chain direction, thus resulting in a giant enhancement in the optical anisotropy. By showing a strong connection between structural disorder with picoscale displacements and the optical response in BaTiS 3 , this study opens a pathway for designing optical materials with high refractive index and functionalities such as large optical anisotropy and nonlinearity.

36 MATERIALS SCIENCE↗

Holotomography Phase-Retrieval

Holotomography is a non-destructive x-ray imaging technique which allows to visualize the interior morphology of object without damaging them. It is similar to x-ray computed tomography (CT), but unlike conventional CT, which is based on the attenuation of x-rays passing through the object, holotomography exploits the phase shift caused by the sample. This phase-contrast imaging allows to increase image contrast by recovering refractive index of materials and is proven to be more sensitive to density variations than conventional absorption-based X-ray imaging when applied to low-Z materials. In holotomography, the phase is retrieved by measuring the variations in intensity of the object at different sample to detector distances. Several algorithms exist to perform this task such as, contrast transfer function (CTF), transport of intensity equation (TIE), and a mixed approach which combine both TIE and CTF.

Forien, Jean-Baptiste↗

Digital and Gradient Refractive Index Planar Optics by Nanoimprinting Mesoporous Silicon

We report the realization of digital and gradient index flat-optics and planar waveguides using the ‘nanoimprinting refractive index’ (NIRI) technique applied to mesoporous silicon. This technique combines the distinct optical and mechanical metamaterial qualities of mesoporous silicon, including its widely tunable effective refractive index and ability to undergo plastic deformation with a near zero Poisson ratio. Nanoimprinting with premastered and reusable stamps containing analog or digital features enables the continuous or discontinuous patterning of refractive index with high contrast Δn ≥ 0.8 and subwavelength resolution. Using NIRI we experimentally demonstrate a wavefront shaping flat microlens array operating in the visible (405–635 nm) and mesoporous silicon and silica waveguides operating near 1310 nm. This study demonstrates the viability of patterning arbitrary refractive index distributions, n(x,y), on the surface of a chip while circumventing the challenges and limitations of top-down lithographic techniques – thus opening a low-cost and scalable approach for the realization of advanced planar optical technologies.

36 MATERIALS SCIENCE↗

Atomic Layer Deposition for Enhanced Light Confinement in Nonlinear Metasurfaces

Metasurfaces enable the generation of strong nonlinear signals, with nanoantenna resonances significantly enhancing the nonlinear response through tailored light–matter interactions. Commonly used nonlinear materials, such as lithium niobate and other similar crystals, have relatively moderate refractive indices, limiting their ability to achieve the strong mode localization attainable with high-refractive-index materials like silicon. Here, we report on enhancing mode confinement in nonlinear metasurfaces by employing conformal coatings of titania with atomic layer deposition (ALD). We develop a low-temperature ALD that enables the augmentation of resonances in materials that cannot withstand high-temperature processing, including polymers. We report on the design of a metasurface incorporating a nonlinear crystal and an ALD coating, achieving enhanced mode localization through this approach in the near-infrared wavelength range. We numerically demonstrate a significant enhancement in second-harmonic generation in the designed metasurface, achieved by optimizing the thickness of the ALD coating for the telecommunication wavelength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Weight Distribution Analysis of Pyrolysis Oils by Gel Permeation Chromatography

Comprehensive analysis of the molecular weight distribution of raw and catalytic fast pyrolysis oils derived from biomass remains a key technical hurdle to understanding oil quality as it relates to downstream use and multiple methods may be necessary to accurately represent all components present. Here, we report the molecular weight distribution metrics of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) oils as determined by gel permeation chromatography (GPC) combined with UV-diode array (UV), differential refractive index (RI), and multi-angle laser light scattering (MALS) detection. The measured molar mass distributions revealed that FP oil consisted of a higher proportion of larger products relative to the low molecular weight products contained in the CFP oil. GPC/RI and UV methods showed FP oil to have higher weight-average molecular weight (Mw) and number-average molecular weight (Mn) than CFP oil based on elution time. However, GPC/MALS, determined the two oils to have similar overall molecular weight distribution metrics (Mw and Mn) and yielded values significantly higher than those determined by RI and UV detectors relative to external standards. Overall, the use of a multiple detection GPC method could enable a more accurate comparison and determination of true molecular weight metrics of bio-oils.

BIOMASS FUELS↗

Graded Buffer Bragg Reflectors with High Reflectivity and Transparency for Metamorphic Optoelectronics

A graded buffer Bragg reflector (GBBR) is a bifunctional device component that provides the reflection of a distributed Bragg reflector and the adjustable lattice constant of a compositionally graded buffer. Prior work showed that these properties can be combined with low threading dislocation density and high reflectivity. Here, we design and demonstrate complex GBBRs for specific metamorphic solar cell applications. We design buffers that provide (1) high reflectivity over a narrow bandwidth, for quantum well solar cells, (2) reflectivity over a wide bandwidth, for optically thin solar cells, and (3) low sidelobe reflection, for multijunction devices that demand low out-of-band reflection. Apodized and triple GBBRs are demonstrated, and transparency is always considered, requiring designs with carefully engineered material combinations. A GBBR with a reflection of 99% is demonstrated, as well as a triple GBBR that has over 80% reflection for 100?nm of the spectrum around 800?nm. We also analyze potential deviations in a baseline GBBR from that of a perfect DBR using transmission electron microscopy to analyze imperfections in the material and modeling to analyze the impact of imperfect refractive index data for lattice-mismatched AlGaInAs. Minimal crosshatch roughness and unintentional thickness variation occur throughout the buffer, which likely influences reflection slightly. Small deviations between the calculated AlGaInAs and utilized AlGaAs refractive index exist, giving methods for future GBBR improvement. While the GBBR designs are intended for metamorphic solar cells, the broad and high reflection may also be useful for other optoelectronic devices such as light-emitting diodes or lasers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

An eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the EAST tokamak in order to study the n|| evolution of lower hybrid waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n|| up to n|| =5 for 4.6GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency (IF) stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n|| of the LH wave in the scrape-off layer (SOL) has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n|| of the lower hybrid waves is about 2.1, corresponding to the main peak 2.04 of the launched n|| spectrum. The n|| deduced by the least square linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n||.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Estimation of Aerosol Columnar Size Distribution from Spectral Extinction Data in Coastal and Maritime Environment

Aerosol columnar size distributions (SDs) are commonly provided by aerosol inversions based on measurements of both spectral extinction and sky radiance. These inversions developed for a fully clear sky offer few SDs for areas with abundant clouds. Here, we estimate SDs from spectral extinction data alone for cloudy coastal and maritime regions using aerosol refractive index (RI) obtained from chemical composition data. Our estimation involves finding volume and mean radius of lognormally distributed modes of an assumed bimodal size distribution through fitting of the spectral extinction data. We demonstrate that vertically integrated SDs obtained from aircraft measurements over a coastal site have distinct seasonal changes, and these changes are captured reasonably well by the estimated columnar SDs. We also demonstrate that similar seasonal changes occur at a maritime site, and columnar SDs retrieved from the combined extinction and sky radiance measurements are approximated quite well by their extinction only counterparts (correlation exceeds 0.9) during a 7-year period (2013–2019). The level of agreement between the estimated and retrieved SDs depends weakly on wavelength selection within a given spectral interval (roughly 0.4–1 µm). Since the extinction-based estimations can be performed frequently for partly cloudy skies, the number of periods where SDs can be found is greatly increased.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Tracking of Carbon Dioxide Concentration Using an Optical Microsphere Resonator Sensor

Whispering gallery mode resonator sensors are nondisruptive optical sensors that can detect and monitor perturbations in a gaseous environment. Through its resonant properties of peak wavelength, amplitude, and quality factor (Q factor), changes in concentration can be quantified within seconds and monitored over days with great stability. In addition, the small footprint, low cost, and high sensitivity are ideal properties for a disposable sensor that can be utilized in extreme environments. Further, the large Q factor of the resonant cavity enables long interaction lengths and amplifies the effect of small changes in the background refractive index, which is detectable in picometer shifts of the resonance wavelength. However, this measurement is susceptible to changes in other environmental factors such as temperature, pressure, and humidity, which manifest on the picometer wavelength scale, reinforcing the need to decouple the variables. In this work, we compare the spectral response of different diameter resonators to carbon dioxide, nitrogen, and its mixtures, observing the spectral shifting and broadening of the cavity resonance near 1550 nm. In addition, the effect of environmental temperature on spectral shifting due to the thermo-optic effect is characterized and quantified. Lastly, the gas concentrations are changed in real time to showcase the tracking and recovery capabilities of the resonator sensor.

47 OTHER INSTRUMENTATION↗