Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic shielding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pulsed Magnetic Gradiometry in Earth's Field [Poster]

We describe a novel pulsed magnetic gradiometer based on the optical interference of sidebands generated using two spatially separated alkali vapor cells. In contrast to traditional magnetic gradiometers, our approach provides a direct readout of the gradient field without the intermediate step of subtracting the outputs of two spatially separated magnetometers. Operation of the gradiometer in multiple field orientations is discussed. The noise floor is measured as low as 25$\frac{fT}{\sqrt{Hz-cm}}$ in a room without magnetic shielding.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Transformative Preparation Methods to Push up High Q&G Performance of FRIB Spare HWR Cryomodule Cavities

The FRIB accelerator project construction, a top priority of US nuclear science, was completed in January 2022, and is now moving to user operation. The stable and reliable operation of the accelerating cryomodules is essential in achieving/fulfilling DOE and user expectations. So far, FRIB cryomodules meet all FRIB specifications for cavity performance. However, during the lifetime of machine operation, degradation of cryomodule performance is possible, as reported in similar operating facilities (CEBAF, SNS). If cryomodule degradation is observed at FRIB, the under-performing cryomodule will require replacement/maintenance. In effort to manage operational reliability, FRIB plans to construct a 0.53 half-wave cryomodule to serve as an active spare. In a parallel effort, FRIB will also work toward increasing operational Q and gradient of spare cryomodule cavities to gain an overall performance margin to support future operational reliability. The current FRIB cavity designs have a potential to operate at gradients higher than 8 MV/m, but are currently limited by field emission (FE) and/or high field Q slope (HFQS); known issue in buffered chemical polished (BCP) treated cavities. The proposal looks to develop transformative surface preparation treatments to improve the operational gradient of spare cryomodules higher than 10 MV/m while maintaining high Q. Thus, increasing operational margin by 30 - 50%. With the goal to improve operational reliability set, the proposal will investigate multiple objectives as possible paths forward to achieve an overall increase in cavity performance and gain a better understanding of SRF limiting mechanisms. The proposal will study the application of different chemical surface treatments to 0.53 half-wave cavities, with the addition of low temperature bakes (LTB), and measure their effects on accelerating performance. Proposed chemical treatments to be explored in this proposal include conventional EP acid mixtures, as well as innovated EP and BCP acid mixtures designed to simplify processing paths in migrating FE and HFQS. The proposed transformative treatment wet N-doping also has the potential to replicate recent advancements in SRF technology relating to nitrogen doping and high Q operation without the requirement for an ultra-high vacuum annealing furnace; currently being developed at FNAL and JLAB. In parallel, high Q performance relating to flux trapping will be investigated with the installation of a second layer of magnetic shielding in the vertical test Dewar. The research objectives presented in the proposal, and their corresponding effects on cavity performance, will provide essential knowledge and future guidance to the SRF community and provide possible paths for future SRF based projects and applications.

43 PARTICLE ACCELERATORS↗

Design of a 915 MHz conduction-cooled cryomodule

High-power, compact, continuous-wave (CW) linear electron accelerators with beam energies of up to 10 MeV are being considered for possible industrial applications. Conduction-cooled, superconducting radio-frequency (SRF) technology allows operating such machines at high electrical efficiency, thereby reducing the operating cost significantly. A prototype conduction-cooled SRF cryomodule has been designed and components are currently being manufactured. The cryomodule features a two-cell, 915 MHz SRF cavity, two cryocoolers, a fundamental power coupler, two magnetic shields, a thermal shield and warm-to-cold transitions. The cryomodule has been designed to be able to provide an energy gain of 3.5 MeV to a CW electron beam with a current of 5 mA. This contribution focusses on thermal and mechanical design aspects of the cryomodule.

Ciovati, G. [Old Dominion Univ., Norfolk, VA (Unit↗

Eddy Current Shielding of the Magnetic Field Ripple in the EIC Electron Storage Ring Vacuum Chambers

The EIC electron storage ring (ESR) has very tight tolerances for the beam position and size stability at the interaction point. The oscillations at the proton betatron frequency and its harmonics are the most dangerous because, for instance, they could lead to unacceptable proton emittance growth from the oscillating beam-beam kick from the electrons at the amplitude of the positional oscillations as low as 10 -4 of the beam size. Even at much lower frequencies, down to the single Hz range, the position oscillations at a few percent level of the nominal beam size were found to be dangerous. These oscillations could have different causes including magnet power supply ripple, mag net vibration, noise in the main and crab RF systems, and some collective instabilities. To specify the acceptable level of the current ripple and noise of the magnet power supplies we need to accurately account for the eddy current shielding by the vacuum chamber, as well as, potentially, by the laminated magnet yokes (considered elsewhere). With some ap proximations, the chamber shielding can be described analytically. The main objective of this note is to derive these analytical expressions and to document the resulting shielding performance of the ESR chamber.

43 PARTICLE ACCELERATORS↗

Analysis of Magnetic Field Emissions and Shield Requirements for Interoperating High-Power EV Wireless Charging System

In this study, the magnetic field emission (MFE) is investigated for matching (identical primary and secondary couplers) and interoperating (different couplers) 11 kW wireless charging systems (WCS). The interoperating charging pads generate higher MFE than the matching charging-pads; hence, using interoperable couplers requires a more effective shielding. In this work, different shield topologies are investigated to suppress the MFE for interoperable conditions. Four 11 kW WCSs with the unipolar (uni) and bipolar (bi) transmitter (Tx) and receiver (Rx) pads has been investigated: 1) uniTx with uniRx, 2) uniTx with biRx, 3) biTx with uniRx, and 4) biTx with bi-Rx. The studied systems are designed for 11 kW WPT3 level with Z2 airgap class (140-150 mm) resembling the standard SAE-J2954. The WCSs are simulated in finite element analysis (FEA) and validated experimentally using a 11 kW biTx-biRx system. The experimental results match with the simulation results with <5% error. The FEA results show that a biTx needs a magnetic shield, and a uniTx needs an aluminum shield to meet the MFE under all interoperability and alignment conditions.

Mohammad, Mostak↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Improvements on the Diagnostic Residual Gas Analyzer at Wendelstein 7-X

Exhaust gas analysis provides key information on fusion processes, divertor operation, and wall state in fusion experiments and future reactors. The diagnostic residual gas analyzer (DRGA) concept has been developed for ITER with a focus on fast helium and hydrogen isotope detection. The first operation of the prototype DRGA (P-DRGA) at the stellarator Wendelstein 7-X showed potential for improvement in terms of magnetic sensor shielding, data acquisition automation, and potential new additions to the cluster of sensors on the P-DRGA. More recently, a Monte Carlo simulation of the flow of the mixed gas species effluent from the pressure-reducing orifice, down to about 8-m sampling tube and into the analysis region of the sensors, has been found to generally agree with previous calculations and measurements but revealed potential back-streaming effects for light gases, with impact on detection limits both for the prototype and for the ITER DRGA currently in design. For the upcoming campaign of the prototype, an enhanced soft iron shield will safeguard the gauges against magnetic stray field influence. The newly introduced shielding has been tested for its effect on magnetic stray fields and found to reduce the inside residual field by about two orders of magnitude.

Schlisio, G↗

Neutronics analysis of spin-polarized fuel in spherical tokamaks

The effect of spin-polarized deuterium–tritium fuel on the blanket, magnets, and surrounding structures is analyzed for a spherical tokamak fusion power plant. The focus of this paper is the neutron flux distribution in the fusion device and the corresponding engineering considerations, such as tritium breeding ratio (TBR) and magnet fluence. Significant benefits were found for anti-aligned polarization: a 2.7% increase in the total TBR (which could increase significantly with further optimization) and an approximately 68% increase in the magnet lifetime. If the inboard breeding blanket can be replaced with extra shielding and magnets, then it could significantly increase fusion power with no loss of magnet lifetime. This would be accomplished by increasing the toroidal field strength.

fusion↗

Molecular NMR shieldings, J -couplings, and magnetizabilities from numeric atom-centered orbital based density-functional calculations

This paper reports and benchmarks a new implementation of nuclear magnetic resonance shieldings, magnetizabilities, and J-couplings for molecules within semilocal density functional theory, based on numeric atom-centered orbital (NAO) basis sets. NAO basis sets are attractive for the calculation of these nuclear magnetic resonance (NMR) parameters because NAOs provide accurate atomic orbital representations especially near the nucleus, enabling high-quality results at modest computational cost. Moreover, NAOs are readily adaptable for linear scaling methods, enabling efficient calculations of large systems. Here, the paper has five main parts: (1) It reviews the formalism of density functional calculations of NMR parameters in one comprehensive text to make the mathematical background available in a self-contained way. (2) The paper quantifies the attainable precision of NAO basis sets for shieldings in comparison to specialized Gaussian basis sets, showing similar performance for similar basis set size. (3) The paper quantifies the precision of calculated magnetizabilities, where the NAO basis sets appear to outperform several established Gaussian basis sets of similar size. (4) The paper quantifies the precision of computed J-couplings, for which a group of customized NAO basis sets achieves precision of ~Hz for smaller basis set sizes than some established Gaussian basis sets. (5) The paper demonstrates that the implementation is applicable to systems beyond 1000 atoms in size.

74 ATOMIC AND MOLECULAR PHYSICS↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron irradiation & thermomechanical experiment (NITE) - design

For the reliable long-term operation of fusion power plants, it is crucial to understand and predict the lifetime of materials in use. These materials include all structural and functional materials utilized at the first wall, blanket, magnets, and shielding. The key challenge is, that the harsh environment including high heat fluxes, high thermal stress and stress cycling, neutron irradiation, and sputtering on such materials should not be viewed separately. Currently, the synergistic loads cannot be evaluated experimentally because of the lack of adequate facilities. The purpose of that work is to design a synergetic Neutron Irradiation and Thermomechanical Experiment (NITE) for fusion materials. This design will leverage the existing Advanced-Test-Reactor (ATR), a fission reactor at the Idaho National Laboratory. We also acknowledge that with existing fission reactors the exact fusion condition cannot be created, and the limitations are critically discussed. The combination of neutron irradiation with a high heat flux is the focus. This is realized with an irradiation capsule design that includes a TRISO fueled region inside the capsule to enable a steady-state heat flux on one side of the specimen. In conclusion, the experimental design modeling showed that steady-state heat fluxes of 2.4 MW/m 2 with a thermal gradient of above 250°C can be achieved in a 5 mm thick specimen.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space radiation measurements during the Artemis I lunar mission

Space radiation is a notable hazard for long-duration human spaceflight. Associated risks include cancer, cataracts, degenerative diseases and tissue reactions from large, acute exposures. Space radiation originates from diverse sources, including galactic cosmic rays, trapped-particle (Van Allen) belts5 and solar-particle events. Previous radiation data are from the International Space Station and the Space Shuttle in low-Earth orbit protected by heavy shielding and Earth’s magnetic field and lightly shielded interplanetary robotic probes such as Mars Science Laboratory and Lunar Reconnaissance Orbiter. Limited data from the Apollo missions and ground measurements with substantial caveats are also available. Here we report radiation measurements from the heavily shielded Orion spacecraft on the uncrewed Artemis I lunar mission. At differing shielding locations inside the vehicle, a fourfold difference in dose rates was observed during proton-belt passes that are similar to large, reference solar-particle events. Interplanetary cosmic-ray dose equivalent rates in Orion were as much as 60% lower than previous observations. Furthermore, a change in orientation of the spacecraft during the proton-belt transit resulted in a reduction of radiation dose rates of around 50%. These measurements validate the Orion for future crewed exploration and inform future human spaceflight mission design.

79 ASTRONOMY AND ASTROPHYSICS↗

Printed copper-nanoplate conductor for electro-magnetic interference

As one of the conductive ink materials with high electric conductivity, elemental copper (Cu) based nanocrystals promise for printable electronics. Here, single crystalline Cu nanoplates were synthesized using a facile hydrothermal method. Size engineering of Cu nanoplates can be rationalized by using the LaMer model and the versatile Cu conductive ink materials are suitable for different printing technologies. The printed Cu traces show high electric conductivity of 6 MS m -1 , exhibiting electro-magnetic interference shielding efficiency value of 75 dB at an average thicknesses of 11 μ m. Together with flexible alumina ceramic aerogel substrates, it kept 87% conductivity at the environmental temperature of 400 °C, demonstrating the potential of Cu conductive ink for high-temperature printable electronics applications.

Materials Science↗

Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab

The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets – a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. In this work, the torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗