Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Characteristics of coherent population trapping in multilevel systems for magnetometry in plasma research

An analysis is presented of the feasibility of measurements of local poloidal magnetic fields in toroidal magnetic fusion devices using coherent population trapping (CPT) in hydrogen-like probing atoms. A measurement scheme is examined in which CPT suppresses the resonance fluorescence from a probing beam of light neutrals with Zeeman-split levels. Feasibility requirements for CPT in three- and five-level systems are discussed. As a result, a theory of CPT-based magnetometry is developed for a system significantly more complex than the conventional three-level {Lambda} system. A theoretical analysis shows that this technique can be used to measure a local safety factor in a toroidal device to an accuracy of a few percent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear optical magnetometry with accessible in situ optical squeezing

In this paper, we demonstrate compact and accessible squeezed-light magnetometry using four-wave mixing in a single hot rubidium vapor cell. The strong intrinsic coherence of the four-wave mixing process results in nonlinear magneto-optical rotation (NMOR) on each mode of a two-mode relative-intensity squeezed state. Finally, this framework enables 4.7 dB of quantum noise reduction while the opposing polarization rotation signals of the probe and conjugate fields add to increase the total signal to noise ratio.

47 OTHER INSTRUMENTATION↗

Low-T magnetometry study of S = 1 Q2D [Ni(pyz) 2 (H 2 O) 2 ](BF 4 ) 2 (pyz = pyrazine)

[Ni(pyz) 2 (H 2 O) 2 ](BF 4 ) 2 (pyz = N 2 C 4 H 4 ) was synthesized by a solvent-free technique and its structure solved by synchrotron X-ray powder diffraction.1 The compound contains S = 1 Ni(II) ions and has tetragonal symmetry. Two-D [Ni(pyz) 2 (H 2 O) 2 ] 2+ square lattices propagate in the ab-plane and stack along the c-axis (Fig. 1). Water ligands occupy axial sites and form H-bonds with interlayer BF 4 - ions. SQUID magnetometry shows a possible transition to long-range magnetic order near 3 K. We measured the magnetization of [Ni(pyz) 2 (H 2 O) 2 ](BF 4 ) 2 as a function of temperature to search for field-induced phase transitions and briefly report those findings here.

36 MATERIALS SCIENCE↗

Spaceborne magnetometry

Low orbit (160 km altitude) satellite magnetometry is discussed. Magnetic field simulations and theoretical analyses were performed. They suggest that at 160 km, resolution value is 10, compared to 0.6 for Magsat, and that the satellite can reveal significant information on crustal tectonics. Vector and scalar magnetometers should be carried.

Taylor, P. T.↗

Mercury's Surface Magnetic Field Determined from Proton-Reflection Magnetometry

Solar wind protons observed by the MESSENGER spacecraft in orbit about Mercury exhibit signatures of precipitation loss to Mercury's surface. We apply proton-reflection magnetometry to sense Mercury's surface magnetic field intensity in the planet's northern and southern hemispheres. The results are consistent with a dipole field offset to the north and show that the technique may be used to resolve regional-scale fields at the surface. The proton loss cones indicate persistent ion precipitation to the surface in the northern magnetospheric cusp region and in the southern hemisphere at low nightside latitudes. The latter observation implies that most of the surface in Mercury's southern hemisphere is continuously bombarded by plasma, in contrast with the premise that the global magnetic field largely protects the planetary surface from the solar wind.

loss cone↗

FORWARD: A Toolset for Multiwavelength Coronal Magnetometry

Determining the 3D coronal magnetic field is a critical, but extremely difficult problem to solve. Since different types of multiwavelength coronal data probe different aspects of the coronal magnetic field, ideally these data should be used together to validate and constrain specifications of that field. Such a task requires the ability to create observable quantities at a range of wavelengths from a distribution of magnetic field and associated plasma i.e., to perform forward calculations. In this paper we describe the capabilities of the FORWARD SolarSoft IDL package, a uniquely comprehensive toolset for coronal magnetometry. FORWARD is a community resource that may be used both to synthesize a broad range of coronal observables, and to access and compare synthetic observables to existing data. It enables forward fitting of specific observations, and helps to build intuition into how the physical properties of coronal magnetic structures translate to observable properties. FORWARD can also be used to generate synthetic test beds from MHD simulations in order to facilitate the development of coronal magnetometric inversion methods, and to prepare for the analysis of future large solar telescope data.

Sun: magnetic fields↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

Curl up with a good B : detecting ultralight dark matter with differential magnetometry

Ultralight dark matter (such as kinetically mixed dark-photon dark matter or axionlike dark matter) can source an oscillating magnetic-field signal at the Earth’s surface, which can be measured by a synchronized array of ground-based magnetometers. The global signal of ultralight dark matter can be robustly predicted for low masses, when the wavelength of the dark matter is larger than the radius of the Earth, $λ_{DM}$ $\gg$ R. However, at higher masses, environmental effects, such as the Schumann resonances, can become relevant, making the global magnetic-field signal B difficult to reliably model. In this work, we show that ∇ × B is robust to global environmental details, and instead only depends on the local dark matter amplitude. We therefore propose to measure the local curl of the magnetic field at the Earth’s surface, as a means for detecting ultralight dark matter with $λ_{DM}$ ≲ R. As this measurement requires vertical gradients, it can be done near a hill/mountain. Our measurement scheme not only allows for a robust prediction, but also acts as a background rejection scheme for external noise sources. We show that our technique can be the most sensitive terrestrial probe of dark-photon dark matter for frequencies 10 Hz ≤ $f_{A'}$ ≤ 1 kHz (corresponding to masses 4 × 10 –14 eV ≤ $m_{A'}$ ≤ 4 × 10 –12 eV). It can also achieve sensitivities to axionlike dark matter comparable to the CAST helioscope, in the same frequency range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust absolute magnetometry with organic thin-film devices

Magnetic field sensors based on organic thin-film materials have attracted considerable interest in recent years as they can be manufactured at very low cost and on flexible substrates. However, the technological relevance of such magnetoresistive sensors is limited owing to their narrow magnetic field ranges (~30mT) and the continuous calibration required to compensate temperature fluctuations and material degradation. Conversely, magnetic resonance (MR)- based sensors, which utilize fundamental physical relationships for extremely precise measurements of fields, are usually large and expensive. Here we demonstrate an organic magnetic resonance-based magnetometer, employing spin-dependent electronic transitions in an organic diode, which combines the low-cost thin-film fabrication and integration properties of organic electronics with the precision of a MR-based sensor. We show that the device never requires calibration, operates over large temperature and magnetic field ranges, is robust against materials degradation and allows for absolute sensitivities of <50nTHz -1/2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonant torsion magnetometry in anisotropic quantum materials

Unusual behavior in quantum materials commonly arises from their effective low-dimensional physics, reflecting the underlying anisotropy in the spin and charge degrees of freedom. Here we introduce the magnetotropic coefficient k = ∂ 2 F/∂θ 2 , the second derivative of the free energy F with respect to the magnetic field orientation θ in the crystal. We show that the magnetotropic coefficient can be quantitatively determined from a shift in the resonant frequency of a commercially available atomic force microscopy cantilever under magnetic field. This detection method enables part per 100 million sensitivity and the ability to measure magnetic anisotropy in nanogram-scale samples, as demonstrated on the Weyl semimetal NbP. Measurement of the magnetotropic coefficient in the spin-liquid candidate RuCl 3 highlights its sensitivity to anisotropic phase transitions and allows a quantitative comparison to other thermodynamic coefficients via the Ehrenfest relations.

36 MATERIALS SCIENCE↗

High field magnetometry with hyperpolarized nuclear spins

Abstract Quantum sensors have attracted broad interest in the quest towards sub-micronscale NMR spectroscopy. Such sensors predominantly operate at low magnetic fields. Instead, however, for high resolution spectroscopy, the high-field regime is naturally advantageous because it allows high absolute chemical shift discrimination. Here we demonstrate a high-field spin magnetometer constructed from an ensemble of hyperpolarized 13 C nuclear spins in diamond. They are initialized by Nitrogen Vacancy (NV) centers and protected along a transverse Bloch sphere axis for minute-long periods. When exposed to a time-varying (AC) magnetic field, they undergo secondary precessions that carry an imprint of its frequency and amplitude. For quantum sensing at 7T, we demonstrate detection bandwidth up to 7 kHz, a spectral resolution < 100mHz, and single-shot sensitivity of 410pT $$/\sqrt{{{{{{{{\rm{Hz}}}}}}}}}$$ / Hz . This work anticipates opportunities for microscale NMR chemical sensors constructed from hyperpolarized nanodiamonds and suggests applications of dynamic nuclear polarization (DNP) in quantum sensing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarization rotation under two-photon Raman resonance for magnetometry

The polarization rotation and coherent population trapping signal arising due to two photon process using linearly polarized light are found to be significantly enhanced for a Zeeman degenerate system. The zero crossing of the dispersive profile is found to be shifting proportional to the applied magnetic field, albeit the absorptive profile position remains invariant for a slightly imbalanced orthogonal circular polarization component. It provides an alternative method for precise measurement of vector magnetic field without requirement of a bias field. The use of polarization rotation signal for magnetic field measurement offers added advantage due to improved signal to noise ratio.

74 ATOMIC AND MOLECULAR PHYSICS↗

Proximity effect bilayer nano superconducting quantum interference devices for millikelvin magnetometry

Superconducting quantum interference devices (SQUIDs) incorporating thin film nanobridges as weak links have sensitivities approaching that required for single spin detection at 4.2 K. However, due to thermal hysteresis they are difficult to operate at much lower temperatures which hinder their application to many quantum measurements. To overcome this, we have developed nanoscale SQUIDs made from titanium-gold proximity bilayers. We show that their electrical properties are consistent with a theoretical model developed for heat flow in bilayers and demonstrate that they enable magnetic measurements to be made on a sample at system temperatures down to 60 mK.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

AlN/Fe/AlN nanostructures for magnetooptic magnetometry

AlN/Fe/AlN/Cu nanostructures with ultrathin Fe grown by sputtering on Si substrates are evaluated as probes for magnetooptical (MO) mapping of weak currents. They are considered for a laser wavelength of λ = 410 nm (3.02 eV) and operate at oblique light incidence angles, φ{sup (0)}, to enable detection of both in-plane and out-of-plane magnetization. Their performance is evaluated in terms of MO reflected wave electric field amplitudes. The maximal MO amplitudes in AlN/Fe/AlN/Cu are achieved by a proper choice of layer thicknesses. The nanostructures were characterized by MO polar Kerr effect at φ{sup (0)} ≈ 5° and longitudinal Kerr effect spectra (φ{sup (0)} = 45°) at photon energies between 1 and 5 eV. The nominal profiles were refined using a model-based analysis of the spectra. Closed form analytical expressions are provided, which are useful in the search for maximal MO amplitudes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal and soft magnetic properties of Co{sub 40}Fe{sub 22}Ta{sub 8}B{sub 30} glassy particles: In-situ X-ray diffraction and magnetometry studies

The structural evolution of Co{sub 40}Fe{sub 22}Ta{sub 8}B{sub 30} glassy particles has been studied by in-situ high-energy synchrotron X-ray diffraction (XRD) upon isochronal annealing. The changes in position, intensity, and full width at half maximum (FWHM) of the first and second diffuse maxima of the XRD patterns suggest the occurrence of irreversible structural relaxation upon the first heating up to a temperature close to the glass transition temperature T{sub g}. The variations in reduced pair correlation functions upon annealing are discussed in the frame of the topological fluctuation theory for structural relaxation. Isochronal annealing of the Co{sub 40}Fe{sub 22}Ta{sub 8}B{sub 30} glassy particles improves their soft magnetic properties through decreasing the coercivity and increasing the magnetic susceptibility, saturation magnetization, and Curie temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetometry of single ferromagnetic nanoparticles using magneto-optical indicator films with spatial amplification

We present a magneto-optical technique to spatially amplify and image fringe fields from single ferromagnetic nanorods. The fringe fields nucleate magnetic domains in a low-coercivity, perpendicularly magnetized indicator film, which are expanded by an applied out-of-plane field from the nanoscale to the microscale for measurement with polar Kerr microscopy. The nucleation location and therefore magnetic orientation of the sample nanorod are detected as spatially dependent field biases in locally measured hysteresis loops of the indicator film. We first discuss our method to fabricate the high-sensitivity indicator film with low energy argon ion irradiation. We then present a map of the amplified signal produced from a single nanorod as measured by the indicator film and compare it with a simultaneously obtained, unamplified fringe field map. The comparison demonstrates the advantage of the amplification mechanism and the capability of the technique to be performed with single-spot magneto-optical Kerr effect magnetometers. Our signal-to-noise ratio determines a minimum measureable particle diameter of tens of nanometers for typical transition metals. We finally use our method to obtain hysteresis loops from multiple nanorods in parallel. Our technique is unperturbed by applied in-plane fields for magnetic manipulation of nanoparticles, is robust against many common noise sources, and is applicable in a variety of test environments. We conclude with a discussion of the future optimization and application of our indicator film technique.