Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cross-correlation of the extragalactic gamma-ray background with the thermal Sunyaev-Zel’dovich effect in the cosmic microwave background

Cosmic rays in galaxy clusters are unique probes of energetic processes operating with large-scale structures in the Universe. Precise measurements of cosmic rays in galaxy clusters are essential for improving our understanding of nonthermal components in the intracluster medium (ICM) as well as the accuracy of cluster mass estimates in cosmological analyses. In this paper, we perform a cross-correlation analysis with the extragalactic gamma-ray background and the thermal Sunyaev-Zeldovich (tSZ) effect in the cosmic microwave background. The expected cross-correlation signal would contain rich information about the cosmic-ray-induced gamma-ray emission in the most massive galaxy clusters at $\textit{z}$ ~ 0.1 – 0.2 . We analyze the gamma-ray background map with 8 years of data taken by the Large Area Telescope onboard Fermi satellite and the publicly available tSZ map by Planck. We confirm that the measured cross-correlation is consistent with a null detection, and thus it enables us to put the tightest constraint on the acceleration efficiency of cosmic-ray protons at shocks in and around galaxy clusters. In this work, we find the acceleration efficiency must be below 5% with a 2σ confidence level when the hydrostatic mass bias of clusters is assumed to be 30%, and our result is not significantly affected by the assumed value of the hydrostatic mass bias. Our constraint implies that the nonthermal cosmic-ray pressure in the ICM can introduce only a≲3% level of the hydrostatic mass bias, highlighting that cosmic rays alone do not account for the mass bias inferred by the Planck analyses. Finally, we discuss future detectability prospects of cosmic-ray-induced gamma rays from the Perseus cluster for the Cherenkov Telescope Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement and calibration of non-linear shear terms in galaxy cluster fields

Introduction Galaxy cluster lensing is a powerful tool for measuring the mass of galaxy clusters, but accurate shear measurement and calibration are critical to obtaining reliable results. This study focuses on the measurement and calibration of weak lensing shears to improve mass estimates in cluster lensing. To deal with the problem, we first developed an image simulation pipeline, jedisim, which utilizes galaxy images extracted from the Hubble Space Telescope (HST) Ultra Deep Field (UDF) and the Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS). Methods The simulations represent realistic galaxy distributions and morphologies as input sources. The foreground halo with a Navarro–Frenk–White (NFW) profile is constructed such that the lensing signals of background galaxies can be measured by the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) Science Pipelines. By comparing the measured reduced shear g meas and the true reduced shear g true , we observe non-linearity up to g ≲ 0.6 . We fit polynomials to the data with quadratic correction adequate to g ≲ 0.4 . Meanwhile, we conduct mass estimates using the pzmassfitter code on four different clusters. Results The mass estimate results are significantly improved after applying the shear calibration derived from the present work—from 4.954 ± 0.504 × 1 0 14 M ⊙ to 10.507 ± 0.498 × 1 0 14 M ⊙ after calibration for a simulated cluster with the mass of 10 × 1 0 14 M ⊙ . In multiple cases of validation, the estimated results are all consistent with true cluster mass. Discussion This study yields the first relationship between reality and shape measurement of the LSST Science Pipelines and serves as the first step toward the overall goal of mass calibration in cluster lensing. By addressing the challenges in shear measurement and calibration, we aim to enhance the accuracy and reliability of mass estimates in galaxy cluster lensing studies.

Astronomy & Astrophysics↗

Scheduling strategies for the ESPRESSO follow-up of TESS targets

ABSTRACT Radial-velocity follow-up of stars harbouring transiting planets detected by TESS is expected to require very large amounts of expensive telescope time in the next few years. Therefore, scheduling strategies should be implemented to maximize the amount of information gathered about the target planetary systems. We consider myopic and non-myopic versions of a novel uniform-in-phase scheduler, as well as a random scheduler, and compare these scheduling strategies with respect to the bias, accuracy and precision achieved in recovering the mass and orbital parameters of transiting and non-transiting planets. This comparison is carried out based on realistic simulations of radial-velocity follow-up with ESPRESSO of a sample of 50 TESS target stars, with simulated planetary systems containing at least one transiting planet with a radius below 4R⊕. Radial-velocity data sets were generated under reasonable assumptions about their noise component, including that resulting from stellar activity, and analysed using a fully Bayesian methodology. We find the random scheduler leads to a more biased, less accurate, and less precise, estimation of the mass of the transiting exoplanets. No significant differences are found between the results of the myopic and non-myopic implementations of the uniform-in-phase scheduler. With only about 22 radial velocity measurements per data set, our novel uniform-in-phase scheduler enables an unbiased (at the level of 1 per cent) measurement of the masses of the transiting planets, while keeping the average relative accuracy and precision around 16 per cent and 23 per cent, respectively. The number of non-transiting planets detected is similar for all the scheduling strategies considered, as well as the bias, accuracy and precision with which their masses and orbital parameters are recovered.

Cabona, L.↗

Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.

Penning trap mass spectrometry↗

Improving initialization and evolution accuracy of cosmological neutrino simulations

Neutrino mass constraints are a primary focus of current and future large-scale structure (LSS) surveys. Non-linear LSS models rely heavily on cosmological simulations — the impact of massive neutrinos should therefore be included in these simulations in a realistic, computationally tractable, and controlled manner. Here, a recent proposal to reduce the related computational cost employs a symmetric neutrino momentum sampling strategy in the initial conditions. We implement a modified version of this strategy into the Hardware/Hybrid Accelerated Cosmology Code (HACC) and perform convergence tests on its internal parameters. We illustrate that this method can impart Script $\mathcal{O}$(1%) numerical artifacts on the total matter field on small scales, similar to previous findings, and present a method to remove these artifacts using Fourier-space filtering of the neutrino density field. Moreover, we show that the converged neutrino power spectrum does not follow linear theory predictions on relatively large scales at early times at the 15% level, prompting a more careful study of systematics in particle-based neutrino simulations. We also present an improved method for backscaling linear transfer functions for initial conditions in massive neutrino cosmologies that is based on achieving the same relative neutrino growth as computed with Boltzmann solvers. Our self-consistent backscaling method yields sub-percent accuracy in the total matter growth function. Comparisons for the non-linear power spectrum with the Mira-Titan emulator at a neutrino mass of m ν = 0.15 eV are in very good agreement with the expected level of errors in the emulator and in the direct N-body simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of property covariance on cluster weak lensing scaling relations

ABSTRACT We present an investigation into a hitherto unexplored systematic that affects the accuracy of galaxy cluster mass estimates with weak gravitational lensing. Specifically, we study the covariance between the weak lensing signal, ΔΣ, and the ‘true’ cluster galaxy number count, Ngal, as measured within a spherical volume that is void of projection effects. By quantifying the impact of this covariance on mass calibration, this work reveals a significant source of systematic uncertainty. Using the MDPL2 simulation with galaxies traced by the SAGE semi-analytic model, we measure the intrinsic property covariance between these observables within the three-dimensional vicinity of the cluster, spanning a range of dynamical mass and redshift values relevant for optical cluster surveys. Our results reveal a negative covariance at small radial scales (R ≲ R200c) and a null covariance at large scales (R ≳ R200c) across most mass and redshift bins. We also find that this covariance results in a $2{\!-\!}3~{{\ \rm per\ cent}}$ bias in the halo mass estimates in most bins. Furthermore, by modelling Ngal and ΔΣ as multi-(log)-linear equations of secondary halo properties, we provide a quantitative explanation for the physical origin of the negative covariance at small scales. Specifically, we demonstrate that the Ngal–ΔΣ covariance can be explained by the secondary properties of haloes that probe their formation history. We attribute the difference between our results and the positive bias seen in other works with (mock)-cluster finders to projection effects. These findings highlight the importance of accounting for the covariance between observables in cluster mass estimation, which is crucial for obtaining accurate constraints on cosmological parameters.

Astronomy & Astrophysics↗

A mass conservative, well balanced, tangency preserving and energy decaying method for the shallow water equations on a sphere

Here a fully discrete surface finite element method is proposed for solving the viscous shallow water equations in a bounded Lipschitz domain on the sphere based on a general triangular mesh. The method consists of a modified Crank–Nicolson method in time and a Galerkin surface finite element method in space for the fluid thickness H and the fluid velocity u. A finite element space tangential to the sphere at all finite element nodes is proposed to approximate the fluid velocity u. The proposed method has second-order accuracy in time and first-order accuracy in space, and preserves mass conservation, well balancedness, tangency of velocity to the sphere, and energy decay. Numerical experiments are presented to illustrate the accuracy of the proposed method and the preservation of the physical properties, including mass conservation, well balancedness, and energy decay. A numerical simulation of ocean mesoscale activity on a circular basin with a continental shelf is provided.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

The freely available “Stopping and Range of Ions in Matter” (SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2–6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. Finally, the ion straggle shows excellent agreement between simulation and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Chemistry↗

Random forest models accurately classify synthetic opioids using high-dimensionality mass spectrometry datasets

Detection of novel threat agents presents several challenges, a principle one being the development of untargeted methods to screen an increasing number of threat chemicals whose exact structures are unknown. With the use of Machine Learning (ML) tools, we can guide the development of analytical methods for broad-spectrum detection of unbounded threat chemical families in complex mixtures. Toward this goal, we used nominal mass and high-resolution mass spectrometry data for hundreds of synthetic opioids and non-opioid compounds. We tested two ML techniques, logistic regression and random forest, to develop models towards a practical, implementable method for opioid detection. We found that of these tested ML methods, random forest models resulted in the highest validation accuracy (95+%) for both nominal mass and high-resolution classification of opioids versus non-opioids, with low false positive and false negative rates. The RF models were then used to successfully predict the classification of 10 compounds—five opioids and five non-opioids not part of the training and validation analysis. This application of ML is a critical step towards the development of field-deployable nominal mass spectrometers with ML-driven analyses for classification of emergent threats.

Arasteh, Kourosh [Lawrence Livermore National Labo↗

Correlations between the Neutron Star Mass–Radius Relation and the Equation of State of Dense Matter

We develop an analytic method of inverting the Tolman–Oppenheimer–Volkoff relations to high accuracy. In principle, a specified energy density–pressure relation gives a unique mass–radius (M–R) relation and vice versa. Our method is developed from the strong correlations that are shown to exist between the neutron star mass–radius curve and the equation of state (EOS) or pressure–energy density relation. Selecting points that have masses equal to fixed fractions of the maximum mass, we find a semi-universal power-law relation between the central energy densities, pressures, sound speeds, chemical potentials, and number densities of those stars, with the maximum mass and the radii of one or more fractional maximum mass points. Rms fitting accuracies, for EOSs without large first-order phase transitions, are typically 0.5% for all quantities at all mass points. The method also works well, although less accurately, in reconstructing the EOS of hybrid stars with first-order phase transitions. These results permit, in effect, an analytic method of inverting an arbitrary M–R curve to yield its underlying EOS. We discuss applications of this inversion technique to the inference of the dense matter EOS from measurements of neutron star masses and radii as a possible alternative to traditional Bayesian approaches.

Bayesian statistics↗

Higgs-mass predictions in the MSSM and beyond

Abstract Predictions for the Higgs masses are a distinctive feature of supersymmetric extensions of the Standard Model, where they play a crucial role in constraining the parameter space. The discovery of a Higgs boson and the remarkably precise measurement of its mass at the LHC have spurred new efforts aimed at improving the accuracy of the theoretical predictions for the Higgs masses in supersymmetric models. The “ Precision SUSY Higgs Mass Calculation Initiative ” (KUTS) was launched in 2014 to provide a forum for discussions between the different groups involved in these efforts. This report aims to present a comprehensive overview of the current status of Higgs-mass calculations in supersymmetric models, to document the many advances that were achieved in recent years and were discussed during the KUTS meetings, and to outline the prospects for future improvements in these calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multifidelity methods for uncertainty quantification of a nonlocal model for phase changes in materials

This study is devoted to the construction of a multifidelity Monte Carlo (MFMC) method for the uncertainty quantification of a nonlocal, non-mass-conserving Cahn-Hilliard model for phase transitions with an obstacle potential. Here, we are interested in estimating the expected value of an output of interest (OoI) that depends on the solution of the nonlocal Cahn-Hilliard model. As opposed to its local counterpart, the nonlocal model captures sharp interfaces without the need for significant mesh refinement. However, the computational cost of the nonlocal Cahn-Hilliard model is higher than that of its local counterpart with similar mesh refinement, inhibiting its use for outer-loop applications such as uncertainty quantification. The MFMC method augments the desired high-fidelity, high-cost OoI with a set of lower-fidelity, lower-cost OoIs to alleviate the computational burden associated with nonlocality. Most of the computational budget is allocated to sampling the cheap surrogate models to achieve speedup, whereas the high-fidelity model is sparsely sampled to maintain accuracy. For the non-mass-conserving nonlocal Cahn-Hilliard model, the use of the MFMC method results in, for a given computational budget, about an order of magnitude reduction in the mean-squared error of the expected value of the OoI relative to that of the Monte Carlo method.

97 MATHEMATICS AND COMPUTING↗

Dynamics-based halo model for large scale structure

Accurate modeling of the one-to-two halo transition has long been difficult to achieve. Here, we demonstrate that physically motivated halo definitions that respect the bimodal phase-space distribution of dark matter particles near halos resolves this difficulty. Specifically, the two phase-space components are overlapping and correspond to (1) particles orbiting the halo and (2) particles infalling into the halo for the first time. Motivated by this decomposition, García et al. [Mon. Not. R. Astron. Soc. 521, 2464 (2023)] advocated for defining halos as the collection of particles orbiting their self-generated potential. This definition identifies the traditional one-halo term of the halo-mass correlation function with the distribution of orbiting particles around a halo, while the two-halo term governs the distribution of infalling particles. We use dark matter simulations to demonstrate that the distribution of orbiting particles is finite and can be characterized by a single physical scale 𝑟 h , which we refer to as the halo radius. The two-halo term is described using a simple yet accurate empirical model based on the Zel’dovich correlation function. We further demonstrate that the halo radius imprints itself on the distribution of infalling particles at small scales. Our final model for the halo-mass correlation function is accurate at the ≈ 2% level for 𝑟∈ [0.1, 50] ℎ −1 Mpc. The Fourier transform of our best-fit model describes the halo-mass power spectrum with comparable accuracy for 𝑘 ∈ [0.06, 6.0] ℎ Mpc −1 .

79 ASTRONOMY AND ASTROPHYSICS↗

Utilizing CellBox to Describe Varied Dynamical Systems

CellBox is a hybrid modeling framework that integrates machine-learning approaches with explicit mathematical modeling to determine the behavior of dynamical systems, intended for determining the complex interactions of molecule and phenotype within a cellular environment using perturbation/response-based data. The original work utilized analysis of a melanoma cell line, SK-Mel-133, which we sought to expand to and evaluate effectiveness in describing other nonlinear systems both within and outside of biology. We evaluated with two models. One model is based upon the free-fall of an object under a velocity-dependent drag force; this produced inherent perturbation/response data. The other model is based upon a form of mass-action molecular kinetics; for this, we ran the simulation to steady state in each species for each perturbation and select the steady state as input for CellBox. We determined that CellBox, outside of its original use case, can still strongly predict even non-biological dynamical systems in the small-perturbation regime, with r = 0.99977 to 0.85123, p < 0.05 for freefall. However, CellBox cannot accurately predict behavior within large-perturbation regimes, p >> 0.05 for freefall. In addition, we performed a naïve comparison of CellBox network structure to known network structure in the mass-action model to assess accuracy.

97 MATHEMATICS AND COMPUTING↗

Physics-tailored machine learning reveals unexpected physics in dusty plasmas

Dusty plasma is a mixture of ions, electrons, and macroscopic charged particles that is commonly found in space and planetary environments. The particles interact through Coulomb forces mediated by the surrounding plasma, and as a result, the effective forces between particles can be nonconservative and nonreciprocal. Machine learning (ML) models are a promising route to learn these complex forces, yet their structure should match the underlying physical constraints to provide useful insight. Here, we demonstrate and experimentally validate an ML approach that incorporates physical intuition to infer force laws in a laboratory dusty plasma. Trained on 3D particle trajectories, the model accounts for inherent symmetries, nonidentical particles, and learns the effective nonreciprocal forces between particles with exquisite accuracy (R 2 > 0.99). We validate the model by inferring particle masses in two independent yet consistent ways. The model’s accuracy enables precise measurements of particle charge and screening length, identifying large deviations from common theoretical assumptions. Our ability to identify unknown physics from experimental data demonstrates how ML-powered approaches can guide new routes of scientific discovery in many-body systems. Furthermore, we anticipate our ML approach to be a starting point for inferring laws from dynamics in a wide range of many-body systems, from colloids to living organisms.

Science & Technology - Other Topics↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Collaborative investigation of the internal flow and near-nozzle flow of an eight-hole gasoline injector (Engine Combustion Network Spray G)

The internal details of fuel injectors have a profound impact on the emissions from gasoline direct injection engines. However, the impact of injector design features is not currently understood, due to the difficulty in observing and modeling internal injector flows. Gasoline direct injection flows involve moving geometry, flash boiling, and high levels of turbulent two-phase mixing. In order to better simulate these injectors, five different modeling approaches have been employed to study the engine combustion network Spray G injector. Here these simulation results have been compared to experimental measurements obtained, among other techniques, with X-ray diagnostics, allowing the predictions to be evaluated and critiqued. The ability of the models to predict mass flow rate through the injector is confirmed, but other features of the predictions vary in their accuracy. The prediction of plume width and fuel mass distribution varies widely, with volume-of-fluid tending to overly concentrate the fuel. All the simulations, however, seem to struggle with predicting fuel dispersion and by inference, jet velocity. This shortcoming of the predictions suggests a need to improve Eulerian modeling of dense fuel jets.

ECN↗