Ionization Mechanisms in a Laser-Produced Plasma for Single Particle Aerosol Mass Spectrometers.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: IONICON High-Resolution PTR-TOF-MS - Trace VOC Analyzer. Concentrations were calculated based on theoretical reaction rates of each species with H3O+. Details of the calculation are found in the PTR-MS Ionicon Manual. Data Notes: It is a high-resolution PTR-TOF-MS we have sub-selected relevant species. Contact us if you want additional data products from this instrument. Header: - CalculatedAcetonitrile[ppbv]: The concentration of acetonitrile expressed in parts per billion by volume (ppbv). - CalculatedAcetaldehyde[ppbv]: The concentration of acetaldehyde expressed in parts per billion by volume (ppbv). - CalculatedAcetone[ppbv]: The concentration of acetone expressed in parts per billion by volume (ppbv). - CalculatedAceticAcid[ppbv]: The concentration of acetic acid expressed in parts per billion by volume (ppbv). - CalculatedIsoprene[ppbv]: The concentration of isoprene expressed in parts per billion by volume (ppbv). - CalculatedMVK[ppbv]: The concentration of methyl vinyl ketone (MVK) and methacrolein (MACR) expressed in parts per billion by volume (ppbv). - CalculatedMEK[ppbv]: The concentration of methyl ethyl ketone (MEK) expressed in parts per billion by volume (ppbv). - CalculatedBenzene[ppbv]: The concentration of benzene expressed in parts per billion by volume (ppbv). - CalculatedToluene[ppbv]: The concentration of toluene expressed in parts per billion by volume (ppbv).
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.
A method for analyzing single cells by mass spectrometry includes the steps of providing a plurality of cells in a liquid medium and placing the cells and liquid medium in a single cell isolation and ejection system. Liquid medium containing a single cell is released from the single cell isolation and ejection system. The liquid medium and single cell are captured in a capture probe containing a flowing capture probe solvent. The cell is lysed by a lysis inducer in the capture probe to disperse single cell components into the medium. The lysed single cell components are transported to a mass spectrometer, where the lysed single cell components entering the mass spectrometer are spatially and temporally separated from any dispersed components of another single cell from the sample entering the mass spectrometer. Mass spectrometry is conducted on the lysed single-cell components. A system for analyzing single cells by mass spectrometry is also disclosed.
A method for analyzing single cells by mass spectrometry includes the steps of providing a plurality of cells in a liquid medium and placing the cells and liquid medium in a single cell isolation and ejection system. Liquid medium containing a single cell is released from the single cell isolation and ejection system. The liquid medium and single cell are captured in a capture probe containing a flowing capture probe solvent. The cell is lysed by a lysis inducer in the capture probe to disperse single cell components into the medium. The lysed single cell components are transported to a mass spectrometer, where the lysed single cell components entering the mass spectrometer are spatially and temporally separated from any dispersed components of another single cell from the sample entering the mass spectrometer. Mass spectrometry is conducted on the lysed single-cell components. A system for analyzing single cells by mass spectrometry is also disclosed.
The Rare-RI Ring (R3) is a recently commissioned cyclotronlike storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Isotope Beam Factory (RIBF) in RIKEN. The first application of mass measurement using the R3 mass spectrometer at RIBF is reported. Rare isotopes produced at RIBF— 127 Sn, 126 In, 125 Cd, 124 Ag, 123 Pd—were injected in R3. Masses of 126 In, 125 Cd, and 123 Pd were measured whereby the mass uncertainty of 123 Pd was improved. This is the first reported measurement with a new storage ring mass spectrometry technique realized at a heavy-ion cyclotron and employing individual injection of the preidentified rare nuclei. The latter is essential for the future mass measurements of the rarest isotopes produced at RIBF. The impact of the new 123 Pd result on the solar r-process abundances in a neutron star merger event is investigated by performing reaction network calculations of 20 trajectories with varying electron fraction Y e . It is found that the neutron capture cross section on 123 Pd increases by a factor of 2.2 and β-delayed neutron emission probability, P 1n , of 123 Rh increases by 14%. The neutron capture cross section on 122 Pd decreases by a factor of 2.6 leading to pileup of material at A = 122, thus reproducing the trend of the solar r-process abundances. The trend of the two-neutron separation energies (S 2n ) was investigated for the Pd isotopic chain. The new mass measurement with improved uncertainty excludes large changes of the S 2n value at N = 77. Finally, such large increase of the S 2n values before N = 82 was proposed as an alternative to the quenching of the N = 82 shell gap to reproduce r-process abundances in the mass region of A = 112 – 124.
We report precision mass measurements of 133 Sb 133g,m Te, and 133g,m I, produced at CARIBU at Argonne National Laboratory's ATLAS facility and measured using the Canadian Penning Trap mass spectrometer. These masses clarify an anomaly in the 133 Te β-decay. The masses reported in the 2020 Atomic Mass Evaluation (M. Wang et al., 2021) produce Q B - ( 133 Te)=2920(6) keV; however, the highest-lying 133 I level populated in this decay is observed at E i = 2935.83(15) keV, resulting in an anomalous Q$^i_B-$ = -16(6)keV. Our new measurements give Q B - ( 133 Te)=2934.8(11) keV, a factor of five more precise, yielding Q$^i_B$ = -1.0(12) keV, a 3σ shift from the previous results. This resolves this anomaly, but indicates further anomalies in our understanding of the structure of this isotope.
Atomic masses are a foundational quantity in our understanding of nuclear structure, astrophysics, and fundamental symmetries. The longstanding goal of creating a predictive global model for the binding energy of a nucleus remains a significant challenge, however, and prompts the need for precise measurements of atomic masses to serve as anchor points for model developments. We present precise mass measurements of neutron-rich Ru and Pd isotopes performed at the Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory using the Canadian Penning Trap mass spectrometer. The masses of 108 Ru, 110 Ru, and 116 Pd were measured to a relative mass precision $\delta$$m/m$ ≈ 10 -8 via the phase-imaging ion-cyclotron-resonance technique, and represent an improvement of approximately an order of magnitude over previous measurements. Further, these mass data were used in conjunction with the physically interpretable machine learning (PIML) model, which uses a mixture density neural network to model mass excesses via a mixture of Gaussian distributions. The effects of our new mass data on a Bayesian-updating of a PIML model are presented.
The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.
Introduction (120 words max) Understanding metal-cluster chemistry occuring at solvent boundaries in the aqueous and organic phases has applications in environments from cellular processes to nuclear fuel reprocessing. Transport of metal ions at the boundaries from aqueous to organic phases involves forming a metal-ligand complex, and wherever the initial metal coordination environment is significantly different from the final one, the metal transitions through a series of transient species in passing from one phase to another. Here an investigation of the role of coordination in the chemistry of the transient species using gas-phase measurements that are free of solvent effects to better understand the binding of complexes of metals with triphenylphosphine chalcogenide ligands, examining metal-ligand homo- and hetero-dimers to better understand transient species. Methods (120 word max) Mass spectrometry and collision induced dissociation (CID) experiments were performed with a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer (QTOF) and Bruker amaZon speed ETD (ion trap). High resolution/high mass accuracy spectra were generated using the QTOF. External calibration was performed with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Both mass spectrometers were equipped with either the electrospray ionization source or nanospray sources. Metal samples were prepared between 40 – 60 uM of the metal-ligand complex in 25% water and 75% acetonitrile. Metal-ion clusters were isolated and subjected to collision induced dissociation. Density functional theory calculations were performed. Preliminary Data or Plenary Speakers Abstract (300 words max) Metal ion clusters with triphenylphosphine chalcogenide ligands were observed for group I metals with triphenylphosphine chalcogenide samples in the mass spectrum upon electrospray ionization. For each metal ligand complex of interest, the parent ion was isolated and collision induced dissociation fragmentation spectra were acquired. We observed clusters of group I metal with triphenylphosphine oxide, triphenyl phosphine sulfide, and triphenylphosphine selenide, with homodimers and heterodimer formation. In samples where the ligands were mixed, we observed mixed sodium ligand clusters at varying amounts. These mixed ligand clusters were fragmented. Metal clusters of mixed ligand dimers containing triphenylphosphine oxide showed preferential loss of the other ligand, either triphenylphosphine sulfide or triphenyl selenide. In samples with mixed triphenylphosphine sulfide and triphenylphosphine selenium ligands, sodium bound similarly between the ligands, and losses were more evenly split, showing loss ratio upon CID with losses of triphenylphosphine sulfide:triphenylphosphine selenide 43:57 ratio observed on CID. These results suggest that the oxide binds significantly more strongly than either the selenium or sulfur triphenylphosphine ligand, and the sulfur and selenium ligands are more evenly bound. Calculations were performed using density functional theory to calculate likely structures and bond energies between the group I metal and the ligands. Novel Aspect Novel analysis of sodium bound dimers with chalcogenide triphenylphosphine ligands were investigated using mass spectrometry and theoretical calculations.
Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.