Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Advantages and Limits of Metagenomic Assembly and Binning of a Giant Virus

ABSTRACT Giant viruses have large genomes, often within the size range of cellular organisms. This distinguishes them from most other viruses and demands additional effort for the successful recovery of their genomes from environmental sequence data. Here, we tested the performance of genome-resolved metagenomics on a recently isolated giant virus, Fadolivirus, by spiking it into an environmental sample from which two other giant viruses were isolated. At high spike-in levels, metagenome assembly and binning led to the successful genomic recovery of Fadolivirus from the sample. A complementary survey of the major capsid protein indicated the presence of other giant viruses in the sample matrix but did not detect the two isolated from this sample. Our results indicate that genome-resolved metagenomics is a valid approach for the recovery of near-complete giant virus genomes given that sufficient clonal particles are present. However, our data also underline that a vast majority of giant viruses remain currently undetected, even in an era of terabase-scale metagenomics. IMPORTANCE The discovery of large and giant nucleocytoplasmic large DNA viruses (NCLDV) with genomes in the megabase range and equipped with a wide variety of features typically associated with cellular organisms was one of the most unexpected, intriguing, and spectacular breakthroughs in virology. Recent studies suggest that these viruses are highly abundant in the oceans, freshwater, and soil, impact the biology and ecology of their eukaryotic hosts, and ultimately affect global nutrient cycles. Genome-resolved metagenomics is becoming an increasingly popular tool to assess the diversity and coding potential of giant viruses, but this approach is currently lacking validation.

59 BASIC BIOLOGICAL SCIENCES↗

Testing and analysis of photovoltaic modules for electrochemical corrosion

This paper describes the testing and evaluation used to characterize the mechanisms of electrochemical corrosion of photovoltaic modules - encapsulated solar cells. Accelerated exposure testing was performed on a sample matrix of cell/encapsulant combinations, and microanalytical failure analysis was performed on selected samples to confirm the correlation between the accelerated test data and the life prediction model. A quantitative correlation between field exposure time and exposure time in the accelerated multistress tests was obtained based upon the observation that equal quantities of interelectrode charge transfer resulted in equivalent degrees of electrochemical charge.

Neff, Michael↗

Post-Fragmentation Whole Genome Amplification-Based Method

This innovation is derived from a proprietary amplification scheme that is based upon random fragmentation of the genome into a series of short, overlapping templates. The resulting shorter DNA strands (<400 bp) constitute a library of DNA fragments with defined 3 and 5 termini. Specific primers to these termini are then used to isothermally amplify this library into potentially unlimited quantities that can be used immediately for multiple downstream applications including gel eletrophoresis, quantitative polymerase chain reaction (QPCR), comparative genomic hybridization microarray, SNP analysis, and sequencing. The standard reaction can be performed with minimal hands-on time, and can produce amplified DNA in as little as three hours. Post-fragmentation whole genome amplification-based technology provides a robust and accurate method of amplifying femtogram levels of starting material into microgram yields with no detectable allele bias. The amplified DNA also facilitates the preservation of samples (spacecraft samples) by amplifying scarce amounts of template DNA into microgram concentrations in just a few hours. Based on further optimization of this technology, this could be a feasible technology to use in sample preservation for potential future sample return missions. The research and technology development described here can be pivotal in dealing with backward/forward biological contamination from planetary missions. Such efforts rely heavily on an increasing understanding of the burden and diversity of microorganisms present on spacecraft surfaces throughout assembly and testing. The development and implementation of these technologies could significantly improve the comprehensiveness and resolving power of spacecraft-associated microbial population censuses, and are important to the continued evolution and advancement of planetary protection capabilities. Current molecular procedures for assaying spacecraft-associated microbial burden and diversity have inherent sample loss issues at practically every step, particularly nucleic acid extraction. In engineering a molecular means of amplifying nucleic acids directly from single cells in their native state within the sample matrix, this innovation has circumvented entirely the need for DNA extraction regimes in the sample processing scheme.

Benardini, James↗

Secondary Ion Mass Spectrometry Bias on Isotope Ratios in Dolomite-Ankerite, Part I: δ 18 O Matrix Effects

Here, we document the development of a suite of carbonate mineral reference materials for calibrating SIMS determinations of δ 18 O in samples with compositions along the dolomite–ankerite solid solution series [CaMg(CO 3 ) 2 –CaFe(CO 3 ) 2 ]. Under routine operating conditions for the analysis of carbonates for δ 18 O with an IMS 1280 instrument (at WiscSIMS, University of Wisconsin, Madison), the magnitude of instrumental bias along the dolomite–ankerite series decreased exponentially by ~ 10‰ with increasing Fe-content in the dolomite structure, but appeared insensitive to minor Mn substitution (< 2.6 mol% Mn/(Ca+Mg+Fe+Mn)). The compositional dependence of bias (i.e., the sample matrix effect) was calibrated using the Hill equation, which relates bias to the Fe# of dolomite–ankerite (i.e., molar Fe/(Mg+Fe)) for thirteen reference materials (Fe# = 0.004–0.789); for calibrations employing either 10 or 3 μm diameter spot size measurements, this yielded residual values ≤ 0.3–0.4‰ relative to CRM NBS 19 for most reference materials in the suite. Analytical precision was ± 0.3‰ (2s) for 10-μm spots and ± 0.7‰ (2s) for 3-μm spots, based on the spot-to-spot repeatability of a drift monitor material that ‘bracketed’ each set of ten sample spot analyses. Analytical uncertainty for individual sample analyses was approximated by a combination of precision and calibration residual values (propagated in quadrature), suggesting an uncertainty of ± 0.5‰ (2s) for 10-μm spots and ± 1‰ (2s) for 3-μm spots.

58 GEOSCIENCES↗

STIP-V Inspection Report

The Los Alamos National Laboratory samples from the STIP-­V irradiation arrived at LANL on December 24th, 2014, after some delays en-­route from the Paul Scherrer Institute (PSI). The samples were transferred to the Wing 9 hot cells in early January and unpacked and inspected in cell with the Hirox Digital Optical microscope. The complete sample matrix of LANL specimens can be seen in table one. Due to space and budgetary issues, no TEM samples were sent back to LANL. Additionally the HT9-­WO, HT9-­Shot and T91-Shot samples are actually bend bars, rather than the tensile samples listed.

36 MATERIALS SCIENCE↗

Mineralogy of three slightly palagonitized basaltic tephra samples from the summit of Mauna Kea, Hawaii

The paper characterizes the mineralogy and spectral properties of three slightly palagonitized basaltic tephra samples collected near the summit of Mauna Kea in order to contribute to the basis for inferring mineralogy and processes for Martian surface materials. The mineralogy of size fractions of these samples is examined by diffuse reflectance and FIR spectroscopy, optical microscopy, X-ray diffraction, Moessbauer spectroscopy, magnetic analysis, EMPA, TEM, and SEM. For the 20-1000 micron size fraction, sample HWMK11 (red) is essentially completely oxidized and has a hematite (Ti-hematite) pigment dispersed throughout the silicate matrix. Sample HWMK12 (black) has the lowest proportion of ferric-bearing phases and is thus least weathered. For HWMK11, the amount of hematite is essentially constant, and mica is present only in the coarse clay-sized fraction; smectites are low in structural Fe.

Golden, D. C.↗

Determination of ammonium ion by fluorometry or spectrophotometry after on-line derivatization with o-phthalaldehyde

A fast, sensitive, simple, and highly reproducible method for routine assay of ammonium ion (NH4+) was developed by using HPLC equipment. The method is based on the reaction of NH4+ with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol. After an on-line derivatization, the resulting NH4(+)-OPA product was quantified by using fluorometric or spectrophotometric detection. For fluorometric detection, the excitation and emission wavelengths were 410 and 470 nm, respectively. The spectrophotometric detection was made by measuring absorbance at 410 nm. Results on the effects of OPA-reagent composition and pH, reaction temperature, sample matrix, and linearity of the assay are presented. Even though it took about 2 min from the time of sample injection to the appearance of sample peak, sample injections could be overlapped at an interval of about 1 min. Thus, the actual time needed for analysis was about 1 min per assay. The method can be used in a fully automated mode by using an autosampler injector.

NASA Discipline Life Support Systems↗

Volatile/mobile trace elements in Bholghati howardite

Ag, Au, Bi, Cd, Co, Cs, Ga, In, Rb, Sb, Se, Te, Tl, U, and Zn by RNAA are determined in two kinds of material from the Bholghati howardite: a carbonaceous chondrite clast (BH-4) that originated by primary nebular condensation/accretion processes; whole-rock samples and clasts resulting from parent-body processes, especially igneous differentiation. Trace element contents in Bholghati whole-rock (matrix) samples and/or white eucritic clasts in it are high for an achondrite, and variable. These characteristics are indicative of random condensation of volcanic emanations admixed with preexisting eucrite, diogenite, and howardite layers in the HED parent body. Other HED samples show similar patterns, and the conclusion that these reflect extensive volcanism in an asteroidal-sized object is supported by other Consortium noble gas and cosmochronologic measurements.

Wang, Ming-Sheng↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The quick and ultrasensitive determination of K in NaI using inductively coupled plasma mass spectrometry

A highly sensitive, novel and quick assay method utilizing inductively coupled plasma mass spectrometry was developed for the determination of K in NaI powders and NaI(Tl) scintillator crystals for use in ultralow background applications. The determination of K (viz. 40K), as well as Th and U and their daughters, is important in ultralow background detector materials to ensure incorporation of materials of sufficiently high radiopurity. Through the use of improved instrumentation, cool plasma operating conditions, and meticulously clean sample preparations, detection limits of 11 fg natK∙g-1 (or 341 pBq 40K∙kg-1) was attained for K in pure water. Detection limits in the sample matrix (i.e., NaI) were 0.529 ng natK∙g NaI-1 (or 16.4 Bq 40K∙kg NaI -1). A number of different precursor NaI powder samples and NaI(Tl) scintillator crystals were assayed for their K content. Determinations ranged from 0.757 – 31.4 ng natK∙g NaI-1. This method allows for the screening of materials to unprecedented levels in a fraction of the time compared to gamma counting techniques, providing a useful method for a more effective screening tool of K in ultralow background detector materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Completion of the Viking Labeled Release experiment on Mars

The final Labeled Release (LR) cycle on each Viking lander tested a surface sample that had been stored for several months at approximately 10 C prior to the onset of the active sequence. At each lander site, activity was strongly diminished. This thermal sensitivity of the active agent on the surface of Mars is consistent with a biological explanation of the LR experiment. At the end of one of these cycles, the incubation mixture was heated to 50 C to release any radioactive gas trapped in the sample matrix. The results suggest that more than one carbon substrate is involved in the LR reaction on Mars. The thermal data from the stored samples, coupled with data from previous cycles, have formed the basis for evaluation of the thermal decomposition of the Mars active agent. The slope of the resulting Arrhenius plot has been used to test the fit of other flight data and to calculate the activation energy for thermal decomposition of the Mars agent. The results and their interpretation still leave unresolved the question of whether the Mars LR data were generated by biological or chemical activity.

Levin, G. V.↗

Rapid method to determine 226Ra in steel samples

The rapid measurement of 226 Ra in steel samples is very important in the event of a radiological emergency. 226 Ra (T 1/2 = 1600 y) is a natural radionuclide present in the environment and a highly toxic alpha-emitter. Due to its long life and tendency to concentrate in bones, 226 Ra ingestion or inhalation can lead to significant committed dose to individuals. A new method for the determination of 226 Ra in steel samples has been developed at the Savannah River Environmental Laboratory. The new method employs a rugged acid digestion method that includes hydrofluoric acid, followed by a single precipitation step to rapidly preconcentrate the radium and remove most of the dissolved steel sample matrix. Radium is then separated using a combination of cation exchange and extraction chromatography, and 226 Ra is measured by alpha spectrometry. This approach has a sample preparation time of ~ 8 h for steel samples, has a very high tracer yield (> 88%), and removes interferences effectively. A 133 Ba yield tracer is used so that samples can be counted immediately following the separation method, avoiding lengthy ingrowth times that are required in other methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace elements in 59 mostly highland moon rocks

New chemical analyses for up to 26 trace elements, including seldom-determined highly siderophile elements Ir, Os, Re, Au, Pd, and Ge, for 59 lunar samples are reported. Most of these samples are polymict breccias from Apollo 16. Remarkably few have Group 7 (extremely low Au/Ir) meteoritic components. Several samples have uncommonly high Au/(Ir + Re) ratios, even higher than group 1L. Volatile-element enrichments are found in several fragments from rusty rock 66095. A matrix sample from fragmental breccia 60639 shows Cd and In enrichments, also observed previously in samples of anorthosite and mare basalt from the same breccia. Evidently, for these highly labile elements, chemical exchange has affected clasts that for most other elements are pristine.

Ebihara, Mitsuru↗

An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparate height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid method for the determination of 226Ra in hydraulic fracturing wastewater samples

A new method that rapidly preconcentrates and measures 226 Ra from hydraulic fracturing wastewater samples was developed in the Savannah River Environmental Laboratory. The method improves the quality of 226 Ra measurements using gamma spectrometry by providing up to 100x preconcentration of 226 Ra from this difficult sample matrix, which contains very high levels of calcium, barium, strontium, magnesium and sodium. The high chemical yield, typically 80-90%, facilitates a low detection limit, important for lower level samples, and indicates method ruggedness. Ba-133 tracer is used to determine chemical yield and correct for geometry-related counting issues. The 226 Ra sample preparation takes < 2 hours.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bayesian estimation of Karhunen–Loève expansions; A random subspace approach

One of the most widely-used statistical procedures for dimensionality reduction of high dimensional random fields is Principal Component Analysis (PCA), which is based on the Karhunen-Lo eve expansion (KLE) of a stochastic process with finite variance. The KLE is analogous to a Fourier series expansion for a random process, where the goal is to find an orthogonal transformation for the data such that the projection of the data onto this orthogonal subspace is optimal in the L 2 sense, i.e, which minimizes the mean square error. In practice, this orthogonal transformation is determined by performing an SVD (Singular Value Decomposition) on the sample covariance matrix or on the data matrix itself. Sampling error is typically ignored when quantifying the principal components, or, equivalently, basis functions of the KLE. Furthermore, it is exacerbated when the sample size is much smaller than the dimension of the random field. In this paper, we introduce a Bayesian KLE procedure, allowing one to obtain a probabilistic model on the principal components, which can account for inaccuracies due to limited sample size. The probabilistic model is built via Bayesian inference, from which the posterior becomes the matrix Bingham density over the space of orthonormal matrices. We use a modified Gibbs sampling procedure to sample on this space and then build a probabilistic Karhunen-Lo eve expansions over random subspaces to obtain a set of low-dimensional surrogates of the stochastic process. We illustrate this probabilistic procedure with a finite dimensional stochastic process inspired by Brownian motion.

97 MATHEMATICS AND COMPUTING↗