Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pulsed single-blow regenerator testing

A pulsed single-blow method has been developed for testing of Stirling regenerator materials performance. The method uses a tubular flow arrangement with a steady gas flow passing through a regenerator matrix sample that packs the flow channel for a short distance. A wire grid heater spanning the gas flow channel is used to heat a plug of gas by approximately 2 K for approximately 350 ms. Foil thermocouples monitor the gas temperature entering and leaving the sample. Data analysis based on a 1D incompressible-flow thermal model allows the extraction of Stanton number. A figure of merit involving heat transfer and pressure drop is used to present results for steel screens and steel felt. The observations show a lower figure of merit for the materials tested than is expected based on correlations obtained by other methods.

Oldson, J. C.↗

Exposure History of Separated Phases from the Kapoeta Meteorite

Cosmogenic Be-10, Al-26, Cl-36, and Mn-53 were measured in clasts and matrix samples from Kapoeta. The radionuclide data are consistent with a single stage exposure lasting approximately 3 Ma. These results are not consistent with exposure ages based on cosmogenic Ne-21.

Caffee, M. W.↗

Modeling the Atmospheric Phase Effects of a Digital Antenna Array Communications System

In an antenna array system such as that used in the Deep Space Network (DSN) for satellite communication, it is often necessary to account for the effects due to the atmosphere. Typically, the atmosphere induces amplitude and phase fluctuations on the transmitted downlink signal that invalidate the assumed stationarity of the signal model. The degree to which these perturbations affect the stationarity of the model depends both on parameters of the atmosphere, including wind speed and turbulence strength, and on parameters of the communication system, such as the sampling rate used. In this article, we focus on modeling the atmospheric phase fluctuations in a digital antenna array communications system. Based on a continuous-time statistical model for the atmospheric phase effects, we show how to obtain a related discrete-time model based on sampling the continuous-time process. The effects of the nonstationarity of the resulting signal model are investigated using the sample matrix inversion (SMI) algorithm for minimum mean-squared error (MMSE) equalization of the received signal

Tkacenko, A.↗

Requirements for Portable Instrument Suites during Human Scientific Exploration of Mars

Human explorers on the surface of Mars will have access to a far wider array of scientific tools than previous crewed planetary exploration missions, but not every tool will be compatible with the restrictions of this exploration. Spectrometers on flyby, orbital, and landed missions are currently used to determine the composition and mineralogy of geological materials of various types and sizes, from small fragments to celestial bodies in the solar system. Handheld spectrometers that are capable of in situ analyses are already used for geological exploration on Earth; however, their usefulness for human exploration missions and how data from multiple handheld instruments could be combined to enhance scientific return must be further evaluated. As part of the Biologic Analog Science Associated with Lava Terrains (BASALT) research project, we incorporated two handheld instruments, a visible-near infrared spectrometer and an X-Ray Fluorescence spectrometer, into simulated Mars exploration missions conducted on basaltic terrains in Idaho and Hawai'i. To understand the data quality provided by these handheld spectrometers, we evaluated their performance under varying conditions of measurement time, distance, angle, atmosphere, and sample matrix, and we compared data quality between handheld instruments and laboratory techniques. Here, we summarize these findings, provide guidelines and requirements on how to effectively incorporate these instruments into human exploration missions to Mars, and posit that future iterations of these instruments will be beneficial for enhancing science returned from human exploration missions.

Alexander Sehlke↗

Trace Element and Isotopic Evidence for Bennu's Primitive Provenance

The delivery of material from asteroid (101955) Bennu by NASA’s OSIRIS-REx mission provides the opportunity to investigate some of the most pristine material from the early Solar System [1]. Our team at Lawrence LivermoreNational Laboratory (LLNL) utilized the equivalent of 5.0 mg from Bennu sampleOREX-803015-100 to quantify the major and trace element contents and investigate major element isotopics (Ca, Ti, Cr, Fe, and Ni). Our 5.0 mg aliquot ofOREX-803015-100 was a subsample of dissolved homogenized material representing 20.66 mg [2]. A separate 5.0 mg aliquot was sent to ETH Zürich and is discussed in a companion abstract [3]. Before any chemical separation on our 5.0 mg aliquot, the equivalent of 0.5 mg was removed and analyzed for elemental abundances at LLNL using a ThermoScientific Element XR. Our data agree exceptionally well with those reported by[2], showing that Bennu is primitive and compositionally similar to CI chondrites, Ryugu [4], and the solar photosphere [5]. The remaining ~4.5 mg underwent purification procedures to chemically isolate and purify Ca, Ti, Cr, Fe, and Ni from one another and the sample matrix. Their isotopic compositions were measured on either the Triton TIMS (Ca) at JohnsonSpace Center in Houston, Neoma MC-ICPMS (Ti, Cr) at LLNL, or the Neptune MC-ICPMS (Fe, Ni) at LLNL. Results from the Ca, Ti, Cr, Fe, and Ni isotopic compositions suggest that Bennu is closely related to CI chondrites—consistent with conclusions from elemental composition [2] and oxygen isotopics [6]reported for Bennu. The major element isotope compositions that we will present demonstrate that Bennu likely formed in a similar region of the SolarSystem as CI chondrites and potentially at a similar time of Solar System evolution.

Greg Brennecka↗

Cyclic Oxidation of FeCrAlY/Al2O3 Composites

Three-ply FeCrAlY/Al2O3 composites and FeCrAlY matrix-only samples were cyclically oxidized at 1000 C and 1100 C for up to 1000 1-hr cycles. Fiber ends were exposed at the ends of the composite samples. Following cyclic oxidation, cracks running parallel to and perpendicular to the fibers were observed on the large surface of the composite. In addition, there was evidence of increased scale damage and spallation around the exposed fiber ends, particularly around the middle ply fibers. This damage was more pronounced at the higher temperature. The exposed fiber ends showed cracking between fibers in the outer plies, occasionally with Fe and Cr-rich oxides growing out of the cracks. Large gaps developed at the fiber/matrix interface around many of the fibers, especially those in the outer plies. Oxygen penetrated many of these gaps resulting in significant oxide formation at the fiber/matrix interface far within the composite sample. Around several fibers, the matrix was also internally oxidized showing Al2O3 precipitates in a radial band around the fibers. The results show that these composites have poor cyclic oxidation resistance due to the CTE mismatch and inadequate fiber/matrix bond strength at temperatures of 1000 C and above.

Nesbitt, James A.↗

Geochemical Comparison of Four Cores from the Manson Impact Structure

Concentrations of 33 elements were determined in relatively unaltered, matrix-rich samples of impact breccia at approximately 3-m-depth intervals in the M-1 core from the Manson impact structure, Iowa. In addition, 46 matrix-rich samples from visibly altered regions of the M-7, M-8, and M-10 cores were studied, along with 42 small clasts from all four cores. Major element compositions were determined for a subset of impact breccias from the M-1 core, including matrix-rich impact-melt breccia. Major- and trace-element compositions were also determined for a suite of likely target rocks. In the M-1 core, different breccia units identified from lithologic examination of cores are compositionally distinct. There is a sharp compositional discontinuity at the boundary between the Keweenawan-shale-clast breccia and the underlying unit of impact-melt breccia (IMB) for most elements, suggesting minimal physical mixing between the two units during emplacement. Samples from the 40-m-thick IMB (M-1) are all similar to each other in composition, although there are slight increases in concentration with depth for those elements that have high concentrations in the underlying fragmental-matrix suevite breccia (SB) (e.g., Na, Ca, Fe, Sc), presumably as a result of greater clast proportions at the bottom margin of the unit of impact-melt breccia. The high degree of compositional similarity we observe in the impact-melt breccias supports the interpretation that the matrix of this unit represents impact melt. That our analyses show such compositional similarity results in part from our technique for sampling these breccias: for each sample we analyzed a few small fragments (total mass: approximately 200 mg) selected to be relatively free of large clasts and visible signs of alteration instead of subsamples of powders prepared from a large mass of breccia. The mean composition of the matrix-rich part of impact-melt breccia from the M-1 core can be modeled as a mixture of approximately 35% shale and siltstone (Proterozoic "Red Clastics"), 23% granite, 40% hornblende-biotite gneiss, and a small component (less than 2%) of mafic-dike rocks.

Korotev, Randy L.↗

Significance of major and minor element variations in plagioclase in sodic ferrogabbro and breccia matrix in lunar highlands sample 67915

Attention is given to the significance of the results of a study of Ca, K, Ti, Fe, Mn, and Mg variations in plagioclase in highlands sample 67915,84. This polymict breccia from Outhouse Rock station 11 at the Apollo 16 site has been selected for study because it contains a wide variety of clast types, including a differentiated type-sodic ferrogabbro. It is found that the data on Ca, K, Ti, Fe, Mn, and Mg in plagioclase show no evidence of reaction between sodic ferrogabbro and breccia matrix clasts. Two groups of plagioclase compositions have been recognized in the breccia matrix. The data suggest that the prebreccia characteristics of plagioclase compositions have been preserved in 67915. Data on Mg/(Mg+FE) ratios suggest that the sodic ferrogabbro and the intermediate-Ca plagioclase clasts could be related to the Mg-rich plutonic rock suite and the high-Ca plagioclase clasts to the ferroan anorthosites.

Weiblen, P. W.↗

Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

Morgan, Leah E.↗

Petrology of crystalline matrix breccias from Apollo 17 rake samples

The petrology, mineralogy, and composition of 13 crystalline matrix breccias from the Apollo 17 rake samples are described. The breccias have matrices of uniform modal mineralogy (plagioclase, 50-54%; olivine and pyroxene, 41-46%) but diverse textures. Clast characteristics, including the proportion of plagioclase, the composition in comparison with matrix, and the textures of different clast types, are reported. The majority of bulk matrix compositions plot on or very near the plagioclase-olivine cotectic in the system olivine-anorthite-silica. If the matrix compositions represent impact total melts, the inferred cotectic control requires that the source material was itself an igneous differentiate with compositions along the plagioclase-olivine cotectic. Alternatively, the proximity of the matrix compositions to the plagioclase-olivine cotectic could be accounted for if the breccia matrices represent a suite of impact-generated partial melts.

Warner, R. D.↗

Two-polarity magnetization in the Manson impact breccia

A preliminary paleomagnetic study of the impact breccia matrix and clasts has produced surprising results--nearly antipodal normal and reversed polarity magnetic vectors are observed in different portions of the core. Near-antipodal magnetizations within a segment of matrix and within individual samples rule out core inversion as the explanation of the dual polarity. In both the dense and the sandy matrix breccias, the magnetizations of clasts and matrix within the same core segment are identical; this negative 'conglomerate test' indicates that magnetization originated after impact. Paleomagnetic study of the Manson Impact Structure is an attempt to refine the Ar-40/Ar-39 age (65.7 +/- 1 m.y.) that suggests Manson to be a Cretaceous-Tertiary boundary impact. Refinement is possible because the boundary occurs within a reversed polarity interval (29R) of only 0.5 m.y. duration. The two breccia types in the Manson structure were both examined: one of a very dense matrix and apparently partially melted, and the breccia stratigraphically below it of granular or 'sandy' chloritic matrix. Samples were taken from the matrixes and a wide variety of clast compositions, including granite, diabase, gneiss, amphibolite, and melted granite. Currently, measurements have been made on 22 samples, using 30-35 steps of either alternating field (AF) or thermal demagnetization.

Steiner, M. B.↗

Chondrules and matrix in the Ornans CO3 meteorite - Possible precursor components

Bulk compositions of 17 chondrules and one sample of matrix from CO3 Ornans were determined by instrumental neutron activation analysis. Chondrule precursor components deduced from chondrule compositions are characterized by: (1) common and slightly volatile siderophiles, Cr and chalcophiles, (2) refractory lithophiles and Na, (3) Mn, Si and modal pyroxene, and (4) FeO and olivine. Component 4 may be closely related to matrix material. Precursor components have now been inferred for OC, EH, CV, CM and CO chondrules. An MN- and Si-rich component occurs exclusively among carbonaceous chondrite chondrules. Although there are significant intergroup differences, common to chondrules in all chondrite groups are refractory-lithophile-rich, common-siderophile-rich, and (with the exception of EH) common-lithophile-rich components. This indicates that the siderophile/lithophile and refractory lithophile/common lithophile fractionations recorded in chondrite whole-rocks were established prior to chondrule formation at all nebular locations.

Rubin, Alan E.↗

Wiener-matrix image restoration beyond the sampling passband

A finer-than-sampling-lattice resolution image can be obtained using multiresponse image gathering and Wiener-matrix restoration. The multiresponse image gathering weighs the within-passband and aliased signal components differently, allowing the Wiener-matrix restoration filter to unscramble these signal components and restore spatial frequencies beyond the sampling passband of the photodetector array. A multiresponse images can be reassembled into a single minimum mean square error image with a resolution that is sq rt A times finer than the photodetector-array sampling lattice.

Rahman, Zia-Ur↗

On the role of dimensionality and sample size for unstructured and structured covariance matrix estimation

The experimental observation that a surprisingly small sample size vis-a-vis dimension is needed to achieve good signal-to-interference ratio (SIR) performance with an adaptive predetection filter is explained. The adaptive filter requires estimates as obtained by a recursive stochastic algorithm of the inverse of the filter input data covariance matrix. The SIR performance with sample size is compared for the situations where the covariance matrix estimates are of unstructured (generalized) form and of structured (finite Toeplitz) form; the latter case is consistent with weak stationarity of the input data stochastic process.

Morgera, S. D.↗

Ar-39/Ar-40 systematics of Allende inclusions

A laser microprobe was used to measure the Ar isotopic contents of individual mineral grains in four neutron-irradiated Allende samples: two coarse-grained Ca-Al-rich inclusions; one fine-grained Ca-Al-rich inclusion; and one sample with matrix and miscellaneous chondrules. The following K-Ar ages (G.y.) were obtained after degassing low Ar retentive sites by preheating the samples for one hour at 675 C: matrix, 3.5 + or - 0.2; three miscellaneous chondrules, 4.4 + or - 0.1, 4.0 + or - 0.1, and 4.4 + or - 0.1; and the fine-grained inclusion, 4.5 + or - 0.2. The minerals in the coarse-grained Ca-Al-rich inclusions have ubiquitous chlorine, less than 10 ppm K and apparent ages ranging upwards from 4.6 G.y. to well over 10 G.y. Possible explanations for these apparent ages are atmospheric contamination, the decay of K-40 prior to the formation of the solar system, and the trapping of radiogenic Ar-40 lost by the matrix.

Herzog, G. F.↗

Matrix characteristics and origin of lunar breccia samples no. 12034 and 12073

The transmission electron microscope was used to investigate the nature of the matrix in two samples of lunar breccia. This matrix is composed largely of tiny (0.5 microns) grains of unaltered glass which are plastically fitted against one another, and tightly welded to the clastic fragments with which they are in contact. The breccias have an open framework of angular clastic particles composed mainly of anorthositic, basaltic and glassy fragments. Most of the anorthositic fragments have been shock metamorphosed. Over half of the glassy clasts, and also the former diaplectic glass particles produced from shocked plagioclase, were partly or wholly devitrified before inclusion in the present breccias. It is concluded that each breccia was deposited from a hot basesurge cloud of impact debris, and the tiny bits of glass in the matrix condensed from rock that was volatilized by the heat of major meteorite impact.

Waters, A. C.↗

Rb-Sr systematics for chemically defined Apollo 15 and 16 materials

Concentrations of Rb and Sr and the Sr87/86 ratios are determined in a large number of Apollo 15 samples, including KREEP basalts, mare basalts, anorthosite breccia clasts, lithic fragments, a spinel-bearing clast, green glass samples, breccia matrix, and soils. Relative concentrations of Sm, Eu, Rb, and Sr are also examined in the samples, with particular attention to Rb/Sr systematics vs other trace element abundances and total chemical compositions of rocks. Analysis of crystalline KREEP samples rich in trace elements indicates that the differentiation of these rocks has extended to -4.25 AE age, a significantly later time than the presumed time of accretion of the moon.

Nyquist, L. E.↗