Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry

A fully automated method for the separation of low-concentration uranium from plutonium in environmental swipe samples has been developed. The offline chromatography system features renewable 1 mL Eichrom TEVA and UTEVA column generation from bulk resin slurry. Discrete fractions of the separated actinides are delivered into user defined vials for future analysis. Clean room background levels were achieved outside of a cleanroom environment with this method. Purification of uranium and plutonium from various sample matrixes and at various concentrations was successful. Major and minor isotope ratios for both elements were measured via multiple collector inductively coupled plasma mass spectrometry and were in good agreement with certified reference values. Lastly, validation of the separation method was conducted on archived environmental samples and agreed with values previously reported using standard column chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Randomized Projection for Rank-Revealing Matrix Factorizations and Low-Rank Approximations

Rank-revealing matrix decompositions provide an essential tool in spectral analysis of matrices, including the Singular Value Decomposition (SVD) and related low-rank approximation techniques. QR with Column Pivoting (QRCP) is usually suitable for these purposes, but it can be much slower than the unpivoted QR algorithm. For large matrices, the difference in performance is due to increased communication between the processor and slow memory, which QRCP needs in order to choose pivots during decomposition. Our main algorithm, Randomized QR with Column Pivoting (RQRCP), uses randomized projection to make pivot decisions from a much smaller sample matrix, which we can construct to reside in a faster level of memory than the original matrix. This technique may be understood as trading vastly reduced communication for a controlled increase in uncertainty during the decision process. Furthermore, for rank-revealing purposes, the selection mechanism in RQRCP produces results that are the same quality as the standard algorithm, but with performance near that of unpivoted QR (often an order of magnitude faster for large matrices). Additionally, we also propose two formulas that facilitate further performance improvements. The first efficiently updates sample matrices to avoid computing new randomized projections. The second avoids large trailing updates during the decomposition in truncated low-rank approximations. Our truncated version of RQRCP also provides a key initial step in our truncated SVD approximation, TUXV. These advances open up a new performance domain for large matrix factorizations that will support efficient problem-solving techniques for challenging applications in science, engineering, and data analysis.

97 MATHEMATICS AND COMPUTING↗

Add-a-Source Analysis Method for Neutron Coincidence Counting of Waste: Laboratory Exercises

In this session you will setup the INCC code to perform calibration and verification measurements on simulated waste drums using the Waste Drum Assay System (WDAS) detector, which uses the add-a-source (AAS) method. The basis of the AAS method is to measure the change in the counting rate from a small 252 Cf source (~3x10 4 n/s) located outside of the drum and to use this information to correct the count rate from material inside the drum for any changes caused by the matrix inside the drum. The count rate of the material inside the drum is corrected to the empty drum case so that only a single mass calibration curve has to be measured (for the empty drum configuration). In the WDAS system, the AAS neutron source has one location, centered beneath the waste drum. The sample matrix has two primary effects on the neutrons: (1) energy reduction by scattering reactions and (2) neutron absorption of the low-energy neutrons. In general, the counter is designed with an optimum moderator (CH 2 ) thickness to be relatively insensitive to the energy reduction; however, as the hydrogen density in the drum increases, the adsorption process significantly reduces the measured neutron signal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a System for Rapid Detection of Contaminants in Water Supplies Using Magnetic Resonance and Nanoparticles

To keep the water supply safe and to ensure a swift and accurate response to a water supply contamination event, rapid and robust methods for microbial testing are necessary. Current technologies are complex, lengthy and costly and there is a need for rapid, reliable, and precise approaches that can readily address this fundamental security and safety issue. T2 Biosystems is focused on providing solutions to this problem by making breakthroughs in nanotechnology and biosensor techniques that address the current technical restrictions facing rapid, molecular analysis in complex samples. In order to apply the T2 Biosystems nucleic acid detection procedure to the analysis of nucleic acid targets in unprocessed water samples, Bacillus thuringeinsis was selected as a model organism and local river water was selected as the sample matrix. The initial assay reagent formulation was conceived with a manual magnetic resonance reader, was optimized using a high throughput system, and transferred back to the MR reader for potential field use. The final assay employing the designed and manufactured instruments was capable of detecting 10 CFU/mL of B. thuringiensis directly within the environmental water sample within 90 minutes. Further, discrimination of two closely related species of Bacilli was accomplished using the methods of this project; greater than 3-fold discrimination between B. cereus and B. thuringiensis at a concentrations spanning 10 CFU/mL to 10 5 CFU/mL was observed.

60 APPLIED LIFE SCIENCES↗

Considerations and Lessons Learned from the Use of Gamma Spectroscopy Systems at FUSRAP Project Sites - 17459

This paper will discuss the application of gamma spectroscopy systems for analysis of environmental media samples for parents and daughter progeny of the Natural Uranium and Thorium Decay Series radionuclides. The concentrations and relative ratios of naturally occurring isotopes are used to confirm the presence of FUSRAP-related wastes and for understanding the associated potential dose and health risks. Focus will be given to lessons learned from the set-up and operation of onsite gamma spectroscopy laboratories used to provide stakeholders with defensible and timely results to support FUSRAP site investigations and remediation including adaptive survey design implementation, physical remediation and waste transport, and confirmatory final status survey activities. This paper focuses on the potential impacts to gamma spectroscopy measurement accuracy from the following: - Bias caused by sample matrix effects as well as use of different library reference values between performance evaluation study providers and testing laboratories; - Use of calibration sources with limited energy ranges, and; - Selection of available alternative isotopic decay reference data for the input of line energies and their intensities. These lessons learned include discussing how inter-laboratory measurement differences from blind performance evaluation samples are affected by the manufacturer's measurement method, including equilibrium assumptions; the isotope decay information source library used by the study provider and participating laboratories; and calibration source geometry/density variances from actual sample conditions. Any of these factors can significantly impact the accuracy of reported results data. Deepening the reader's understanding of the various factors that impact the accuracy, interpretation, and overall usability of gamma spectroscopy results data from laboratories will help ensure defensible decision-making and cost-effective mission implementation within FUSRAP and similar remediation programs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BRAVE_EBC-TMT.1.0

Exhaled breath condensate (EBC) represents a low-cost and non-invasive means of examining respiratory health. EBC has been used to discover and validate exhaled volatile and non-volatile biomarkers of disease related to the respiratory system distress such as asthma, COPD, lung cancer, and secondary infections. One newly emerging utilization of EBC, is proteomics analysis, which can provide an unbiased snapshot into ongoing biological processes in the airway. Fully characterizing the biological landscape of EBC collections is challenging though, due to sample variability, and low detection sensitivity. EBC is primarily composed of condensed water, causing technical challenges with detecting key macromolecules from the dilute sample matrix; therefore, high sensitivity techniques are required to unlock the full capability of EBC as a method for non-invasive biomarker detection. To overcome some of these technical challenges for proteomic analyses, we applied our recently developed microscale proteomic techniques and developed a novel TMT based approach which enabled reliable, relative quantification with significantly improved detection of low abundance peptides/proteins across multiple healthy volunteer EBC samples. Our EBC collection design includes longitudinal EBC collections from five individual healthy volunteers on three separate days of the week with triplicate, back-to-back donations each day. Here, we report a total of 235 quantifiable proteins corresponding to 1,877 non-redundant peptides for evaluating sample collection reproducibility and establishing a healthy (human host) baseline EBC biomarker proteome studies. This work will pave the way for further investigations of EBC protein expression profiles and showcase the value of using non-invasive collection method techniques for clinically relevant biomarker discovery. This research was supported by the LDRD Biomedical Resilience And Readiness in AdVerse Operating Environments (BRAVE) Project (73748), and was conducted at Pacific Northwest National Laboratory (PNNL) in Richland, WA. PNNL is a multiprogram national laboratory operated by Battelle for the Department of Energy (DOE) under Contract DE-AC05-76RLO 1830.

59 BASIC BIOLOGICAL SCIENCES↗

Plutonium oxalate precipitation for trace elemental determination in plutonium materials

In this study, an analytical chemistry method has been developed that removes the plutonium (Pu) matrix from the dissolved Pu metal or oxide solution prior to the determination of trace impurities that are present in the metal or oxide. In this study, a Pu oxalate approach was employed to separate Pu from trace impurities. After Pu(III) was precipitated with oxalic acid and separated by centrifugation, trace elemental constituents in the supernatant were analyzed by inductively coupled plasma-optical emission spectroscopy with minimized spectral interferences from the sample matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating Lipidomic Method Development through in Silico Simulation

Judicious selection of mass spectrometry (MS) acquisition parameters is essential for effectively profiling the broad diversity and dynamic range of biomolecules. Typically, acquisition parameters are individually optimized to maximally characterize analytes from each new sample matrix. This time-consuming process often ignores the synergistic relationship between MS method parameters, producing suboptimal results. Here in this paper, we detail the creation of an algorithm which accurately simulates LC-MS/MS lipidomic data acquisition performance for a benchtop quadrupole-Orbitrap MS system. By coupling this simulation tool with a genetic algorithm for constrained parameter optimization, we demonstrate the efficient identification of LC-MS/MS method parameter sets individually suited for specific sample matrices. Finally, we utilize the in silico simulation to examine how continued developments in MS acquisition speed and sensitivity will further increase the power of MS lipidomics as a vital tool for impactful biochemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Matrix Extension Validation of AOCS Ce 2c‐11 for Omega‐3 Polyunsaturated Fatty Acids in Conventional Foods and Dietary Supplements Containing Added Marine Oil

Abstract Marine oils are commonly added to conventional foods and dietary supplements to enhance their contents of omega‐3 polyunsaturated fatty acids (PUFA), including eicosapentaenoic acid (EPA; 20:5n‐3) and docosahexaenoic acid (DHA; 22:6n‐3), which have been associated with numerous potential health benefits. This study compared American Oil Chemists’ Society (AOCS) Official Methods Ce 2b‐11 and Ce 2c‐11 for determining EPA and DHA in foods and dietary supplements and found that AOCS Ce 2c‐11 produces significantly higher analyzed values, which could be attributed to a more comprehensive breakdown of the sample matrix and derivatization of fatty acids. Our subsequent food matrix extension validation of AOCS Ce 2c‐11 demonstrated that the method produces true, accurate, sensitive, and precise determinations of EPA, DHA, and total omega‐3 PUFA in foods and dietary supplements containing added marine oil, including those formulated with emulsified and microencapsulated oils. The method detection limits for EPA and DHA were 0.012 ± 0.002 and 0.011 ± 0.003 mg g −1 , respectively (means ± SD). The analyzed contents of EPA (1.26–386 mg serving −1 ), DHA (1.37–563 mg serving −1 ), and total omega‐3 PUFA (2.69–1270 mg serving −1 ) were reported for 27 conventional food and dietary supplement products. Eighteen products declared contents of DHA, EPA + DHA, or total omega‐3 PUFA on product labels, and the analyzed contents of those fatty acids varied from 95 to 162% of label declarations for all but two of the products.

Li, Ziyi↗

Rapid determination of 226 Ra in emergency urine samples

A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226 Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed. The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226 Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226 Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226 Ra with DGA Resin, saving time. 133 Ba was used instead of 225 Ra as tracer to allow immediate counting; however, 225 Ra can still be used as an option. The rapid purification of 226 Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226 Ra, with rapid removal of isobaric interferences.

61 RADIATION PROTECTION AND DOSIMETRY↗

Refinement of Salt Dissolution Inhibitor Requirements (Final Report)

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. It has been proposed that these corrosion control limits be revisited to evaluate the corrosion susceptibility of carbon steel in environments that more closely resemble current operating conditions at SRS. An experimental matrix was designed to evaluate the use of the pitting factor for supernate chemistries characteristic to SRS, particularly during the salt dissolution process. Two electrochemical methods were identified to determine the susceptibility of A537 and A285 low-carbon steels to pitting corrosion with this chemistry envelope at temperatures up to 75 °C. The predominant electrochemical test method was Cyclic Potentiodynamic Polarization (CPP) studies. Through CPP, the pitting factor was used, based on Hanford Site corrosion studies, to accurately identify pitting susceptibility within the compositional range studied with some conservatism. Additionally, sulfate was determined to have no statistically significant influence, at concentrations up to 0.6 M, on pitting behavior in more concentrated solutions where other aggressive species govern pitting susceptibility. Where CPP was inconclusive, Modified ASTM G192 was successfully used to evaluate pitting susceptibility conditions and allowed for a pass/fail result to be determined. In all cases, the pitting factor was determined to be applicable to the simulants tested, with this metric accurately predicting incidences in which pitting occurred. Based upon the findings in this work, a pitting factor of 1.2 is being proposed to build in a safety factor and remain consistent with the Hanford Site approach. Additionally, a minimum pH limit of 12 is proposed to ensure carbon steel passivity and localized corrosion the primary degradation mechanism. Susceptibility to SCC was evaluated using a reduced matrix of tests at 75 °C. No failures due SCC were observed at open circuit. In addition, tests polarized anodically by 200 mV only resulted in failures for trials with pitting factors less than 0.86. However, a test with a passing condition based upon the pitting factor metric (pitting factor = 1.40) did exhibit a failure with an applied potential of +300 mV vs. OCP. This result is contrary to the prediction based upon the pitting factor, however, a polarization of 300 mV, or even 200 mV, from open circuit is substantial. The relationship between these testing parameters and service environment/conditions and the desired level of conservatism in the metric should be further evaluated in the determination of the significance of this result. While the pitting factor accurately predicted susceptibility to SCC at temperatures up to 75 °C and with positive overpotentials up to 200 mV, the relatively small sample matrix and failure of a passing pitting factor with a 300 mV polarization resulted in an inconclusive determination of whether the pitting factor may be used for predicting susceptibility to SCC at temperatures between 50 °C and 75 °C. As such, additional testing is recommended to evaluate the validity of the pitting factor for SCC susceptibility prediction at temperatures between 50 °C and 75 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BENCHMARKING ORTEC ISOTOPIC MEASUREMENTS AND CALCULATIONS

This report represents a description of compiled benchmark tests conducted to probe and to demonstrate the extensive utility of the Ortec ISOTOPIC {gamma}-ray analysis computer program. The ISOTOPIC program performs analyses of {gamma}-ray spectra applied to specific acquisition configurations in order to apply finite-geometry correction factors and sample-matrix-container photon absorption correction factors. The analysis program provides an extensive set of preset acquisition configurations to which the user can add relevant parameters in order to build the geometry and absorption correction factors that the program determines from calculus and from nuclear g-ray absorption and scatter data. The Analytical Development Section field nuclear measurement group of the Savannah River National Laboratory uses the Ortec ISOTOPIC analysis program extensively for analyses of solid waste and process holdup applied to passive {gamma}-ray acquisitions. Frequently the results of these {gamma}-ray acquisitions and analyses are to determine compliance with facility criticality safety guidelines. Another use of results is to designate 55-gallon drum solid waste as qualified TRU waste3 or as low-level waste. Other examples of the application of the ISOTOPIC analysis technique to passive {gamma}-ray acquisitions include analyses of standard waste box items and unique solid waste configurations. In many passive {gamma}-ray acquisition circumstances the container and sample have sufficient density that the calculated energy-dependent transmission correction factors have intrinsic uncertainties in the range 15%-100%. This is frequently the case when assaying 55-gallon drums of solid waste with masses of up to 400 kg and when assaying solid waste in extensive unique containers. Often an accurate assay of the transuranic content of these containers is not required, but rather a good defensible designation as >100 nCi/g (TRU waste) or <100 nCi/g (low level solid waste) is required. In these cases the ISOTOPIC analysis program is especially valuable because it allows a rapid, defensible, reproducible analysis of radioactive content without tedious and repetitive experimental measurement of {gamma}-ray transmission through the sample and container at multiple photon energies. The ISOTOPIC analysis technique is also especially valuable in facility holdup measurements where the acquisition configuration does not fit the accepted generalized geometries where detector efficiencies have been solved exactly with good calculus. Generally in facility passive {gamma}-ray holdup measurements the acquisition geometry is only approximately reproducible, and the sample (object) is an extensive glovebox or HEPA filter component. In these cases accuracy of analyses is rarely possible, however demonstrating fissile Pu and U content within criticality safety guidelines yields valuable operating information. Demonstrating such content can be performed with broad assumptions and within broad factors (e.g. 2-8) of conservatism. The ISOTOPIC analysis program yields rapid defensible analyses of content within acceptable uncertainty and within acceptable conservatism without extensive repetitive experimental measurements. In addition to transmission correction determinations based on the mass and composition of objects, the ISOTOPIC program performs finite geometry corrections based on object shape and dimensions. These geometry corrections are based upon finite element summation to approximate exact closed form calculus. In this report we provide several benchmark comparisons to the same technique provided by the Canberra In Situ Object Counting System (ISOCS) and to the finite thickness calculations described by Russo in reference 10. This report describes the benchmark comparisons we have performed to demonstrate and to document that the ISOTOPIC analysis program yields the results we claim to our customers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prompt Gamma Analysis of ARIES Materials and Updates to the 2015 Calibration Equations

Prompt gamma (PG) analysis is a nondestructive, nuclear, elemental analysis technique that uses charged particle reactions to interrogate a sample, and elements present in the sample matrix are identified through the characteristic gamma-rays emitted from the product nuclei in alpha-p and alpha-n nuclear reactions. This technique has been applied to plutonium oxide packaged in over 4,000 individual 3013 containers, and the concentrations of certain light elements were determined from the integrated peak areas based on a calibration that was published previously. This report provides the results for a new population of 3013 containers packaged with oxide materials produced by the conversion of metal by Advanced Recovery and Integrated Extraction System (ARIES) project using the direct metal oxidation (DMO) process and muffle furnaces. New PG and analytical chemistry data collected since 2015 were added to the existing calibration data sets to refine the calibration parameters. Calibration equations were also developed for determining beryllium and fluorine at low concentrations in high-purity ARIES product oxides. The new fluorine calibration provides an order of magnitude greater sensitivity and results in an additional 1,408 containers in the original population identified as having fluorine as an impurity. Additionally, equations for calculating the lower limits of detection (LLDs) as a function of the actual counting time (live time) were obtained using WLS regression technique for samples in the calibration data set. This resulted in changes to the LLDs published previously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanostructured materials for selective collection of trace-level metals from aqueous systems.

Nanostructured materials for selective collection of trace-level metals from aqueous systems A critical ability for responding to situations involving environmental contaminants is the ability to quickly identify the contaminant(s) involved and the scope of the contamination. Simple field-screening methods are needed to enable on-site, information allocation and decision making. Currently, analytical technology does not exist to allow quick, accurate, and efficient analysis. Existing field-screening methods lack the selectivity and sensitivity needed to provide key information. A large leap in performance is needed and is very unlikely to be achieved with incremental improvements in procedure, instrument design, or improved electronics. A new analytical approach is required. Deficiencies in selectivity and sensitivity can be addressed with high-performance sorbent materials capable of selectively concentrating the target analytes and removing them from the sample matrix. By concentrating and removing the target analyte, these sorbent materials provide a well-defined matrix for analysis. This chapter examines the use of nanostructured materials for the selective collection of trace-level metals from aqueous systems. The focus lies on thiol-functionalized materials. Focusing on thiol surface chemistry allows comparison of mesoporous silica, activated carbon, and superparamagnetic nanoparticles. The chapter also discusses zeolites, imprinted polymer materials, and activated carbon in general. The materials reviewed here are evaluated based on capacity, selectivity, and affinity for target analytes. Research presented here shows that correctly constructed nanostructured materials are superior to conventional sorbents.

nanomaterials, nanostructures, SAMMS, trace level ↗

Comprehensive review of combustion ion chromatography for the analysis of total, adsorbable, and extractable organic fluorine

Poly‐ and perfluoroalkyl substances (PFAS) are a class of persistent organic pollutants whose high stability and appreciable water solubility have led to near‐global contamination. PFAS are bioaccumulative toxins that have been linked to a myriad of disorders and have been detected nearly universally in human blood. Liquid chromatography‐tandem mass spectrometry is the most frequent method used for quantitation, though this typically only measures a few dozen of the >14 000 known PFAS and has been shown to account for a small portion of the total organic fluorine present. Sum parameter methods such as total, extractable, and adsorbable organic fluorine have emerged as alternative measurements for PFAS determination. Combustion ion chromatography has become the preferred method for organofluorine measurement where the sorbent or extract containing PFAS is combusted and the emitted hydrofluoric acid (HF) is a measure of the cumulative organofluorine present. Herein we critically review the types of organofluorine measurement, their separation from the sample matrix, and key parameters of the analytical instrument that affect sensitivity, reproducibility, and recovery with regards to PFAS analysis.

Chemistry↗

Acylation as a successful derivatization strategy for the analysis of pinacolyl alcohol in a glycerol-rich matrix by GC-MS: application during an OPCW Proficiency Test

A derivatization protocol based on the acylation of pinacolyl alcohol (PA), an important marker for the nerve agent soman, is presented. The procedure provides a convenient means of detecting, by gas chromatography-mass spectrometry (GC-MS), PA when present at a low concentration in a complex glycerol/alcohol-rich matrix. While there are only two reports describing the specific analysis of PA in matrices at low concentrations, the protocol described herein represents the first of its kind in the analysis of PA in a highly reactive matrix. Two alternative paths for the protocol’s execution are presented. The first involves the direct derivatization of the PA with either acetyl or benzoyl chloride; both reactions yield ester products with significantly different retention times than those of the interferences of the reactive glycerol-rich matrix and in areas of the GC-chromatogram featuring lower levels of matrix interferences. A second procedure involved an initial diethyl ether/aqueous extraction of the matrix; while the extraction was found to substantially remove many of the hydrophilic matrix components and improve the overall derivatization, it also led to some loss of PA available for the derivatization. Both protocols were applied to the successful derivatization and analysis of PA by GC-MS when present at a 5 μg.mL -1 concentration in a glycerol-rich matrix sample administered during the 48th Proficiency Test administered by the Organisation for the Prohibition of Chemical Weapons (OPCW).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of urban debris material on the extraction chromatographic separation of strontium: Part II: cement and concrete

The majority of radiochemical separation schemes available have been developed for environmental samples that are not necessarily representative of those found in an urban environment. However, it is much more likely that an incident involving a radiation dispersal device (RDD) would occur in an urban or metropolitan area. It is unclear if the currently available separation schemes would be effective in such an event. It is therefore important to determine if the current schemes would be adequate, or to find efficient and accurate ways to separate radiological material from urban debris. One important radiological material that could be used in an RDD is 90 Sr. Part I of this work investigated the effects steel had on strontium separations, while this work investigates cement and concrete. This research demonstrates that the individual elements present in a cement and concrete sample matrix can give rise to significant interferences with extraction chromatographic separations. In conclusion, solutions of the constituents mixed in representative ratios; however, show fewer problems

36 MATERIALS SCIENCE↗

Plasma-Based Ambient Desorption/Ionization Mass Spectrometry for the Analysis of Liquid Crystals Employed in Display Devices

Liquid-crystal displays (LCDs) are the most frequently used display technology worldwide these days. Due to the rather complex manufacturing process and purity requirements for the chemicals used, quality control and display failure analysis are important analytical tasks. Currently, the state-of-the-art techniques (e.g., high-performance liquid chromatography (HPLC), gas chromatography (GC) coupled to mass spectrometry (MS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), or high-resolution microscopy) are costly and time-consuming. Hence, a new pathway to precisely analyze liquid-crystalline materials and LCDs in their native state is reported. A new approach for direct analysis via plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) offers an inexpensive and faster alternative. In this study, direct analysis in real time (DART), the low-temperature plasma (LTP) probe, and flowing atmospheric-pressure afterglow (FAPA) ADI sources coupled to high-resolution mass spectrometry (HR-MS) are compared based on their capabilities and performance for liquid-crystal analysis. These sources enable direct analyte desorption from a sample surface at ambient conditions and ionize the vaporized analyte molecules in a subsequent step. Primarily, the ionization capabilities of the three ADI sources are compared for individual liquid-crystal standards, mixtures of liquid crystals (LCs), and complex liquid crystal/additive mixtures applied in commercially available LCDs. Furthermore, direct surface analysis from a glass substrate is also performed with ADI-MS to compare their applicability to this type of sample matrix. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗