Search NASA⌕ Search

SEARCH · Search NASA

Results for “maximize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Maximal exercise as a countermeasure to orthostatic intolerance after spaceflight

Previous investigators have suggested that maximal exercise performed 24 h before the end of bed rest, a spaceflight analog, restores prebed rest plasma volume, baroreflex responses, and orthostatic tolerance. PURPOSE: In this case report, we examined the effect of a similar exercise protocol 24 h before a Shuttle landing on the orthostatic responses of four crewmembers (EX) after spaceflights of 8-14 d. Four additional crewmembers (CON) served as controls and did not perform exercise during the final day of the flight. METHODS: Each crewmember performed a 10-min stand test approximately 10 d before launch (L-10) and within 1-2 h of landing (R+0). Cardiac stroke volume was measured (Doppler ultrasound) supine and during each min of standing for three EX and three CON subjects. RESULTS: Preflight, all crewmembers completed the stand test and each group had similar heart rate and blood pressure responses. Postflight, all subjects also completed the 10-min stand test. Each group had similarly elevated supine and standing heart rates, elevated diastolic and mean arterial blood pressures, and reduced pulse pressures compared to L-10. However, postflight cardiac output, mean +/- SEM, (EX: 4.5+/-0.6 L x min(-1); CON: 3.1+/-0.3 L x min(-1)) and stroke volume (EX: 43+/-7 mL x beat; CON: 30+/-6 mL x beat) were higher after 10 min standing in the EX subjects compared to CON subjects. CONCLUSIONS: For these four crewmembers, maximal exercise performed 24 h before landing may have helped maintain stroke volume but did not maintain heart rate and blood pressure responses during standing compared to preflight.

Flight Experiment↗

Application of acute maximal exercise to protect orthostatic tolerance after simulated microgravity

We tested the hypothesis that one bout of maximal exercise performed at the conclusion of prolonged simulated microgravity would improve blood pressure stability during an orthostatic challenge. Heart rate (HR), mean arterial blood pressure (MAP), norepinephrine (NE), epinephrine (E), arginine vasopressin (AVP), plasma renin activity (PRA), atrial natriuretic peptide (ANP), cardiac output (Q), forearm vascular resistance (FVR), and changes in leg volume were measured during lower body negative pressure (LBNP) to presyncope in seven subjects immediately prior to reambulation from 16 days of 6 degrees head-down tilt (HDT) under two experimental conditions: 1) after maximal supine cycle ergometry performed 24 h before returning to the upright posture (exercise) and 2) without exercise (control). After HDT, the reduction of LBNP tolerance time from pre-HDT levels was greater (P = 0.041) in the control condition (-2.0 +/- 0.2 min) compared with the exercise condition (-0.4 +/- 0.2 min). At presyncope after HDT, FVR and NE were higher (P < 0.05) after exercise compared with control, whereas MAP, HR, E, AVP, PRA, ANP, and leg volume were similar in both conditions. Plasma volume (PV) and carotid-cardiac baroreflex sensitivity were reduced after control HDT, but were restored by the exercise treatment. Maintenance of orthostatic tolerance by application of acute intense exercise after 16 days of simulated microgravity was associated with greater circulating levels of NE, vasoconstriction, Q, baroreflex sensitivity, and PV.

NASA Discipline Cardiopulmonary↗

Response of slow and fast muscle to hypothyroidism: maximal shortening velocity and myosin isoforms

This study examined both the shortening velocity and myosin isoform distribution of slow- (soleus) and fast-twitch (plantaris) skeletal muscles under hypothyroid conditions. Adult female Sprague-Dawley rats were randomly assigned to one of two groups: control (n = 7) or hypothyroid (n = 7). In both muscles, the relative contents of native slow myosin (SM) and type I myosin heavy chain (MHC) increased in response to the hypothyroid treatment. The effects were such that the hypothyroid soleus muscle expressed only the native SM and type I MHC isoforms while repressing native intermediate myosin and type IIA MHC. In the plantaris, the relative content of native SM and type I MHC isoforms increased from 5 to 13% and from 4 to 10% of the total myosin pool, respectively. Maximal shortening velocity of the soleus and plantaris as measured by the slack test decreased by 32 and 19%, respectively, in response to hypothyroidism. In contrast, maximal shortening velocity as estimated by force-velocity data decreased only in the soleus (-19%). No significant change was observed for the plantaris.

Non-NASA Center↗

Skeletal muscle fiber type composition and performance during repeated bouts of maximal, concentric contractions

Force output and fatigue and recovery patterns were studied during intermittent short-term exercise. 27 men performed three bouts of 30 maximal unilateral knee extensions on 2 different occasions. Blood flow was maintained or occluded during recovery periods (60 s). Blood flow was restricted by inflating a pneumatic cuff placed around the proximal thigh. Muscle biopsies from vastus lateralis were analyzed for identification of fast twitch (FT) and slow twitch (ST) fibers and relative FT area. Peak torque decreased during each bout of exercise and more when blood flow was restricted during recovery. Initial peak torque (IPT) and average peak torque (APT) decreased over the three exercise bouts. This response was 3 fold greater without than with blood flow during recovery. IPT and APT decreased more in individuals with mainly FT fibers than in those with mainly ST fibers. It is suggested that performance during repeated bouts of maximal concentric contractions differs between individuals with different fiber type composition. Specifically, in high intensity, intermittent exercise with emphasis on anaerobic energy release a high FT composition may not necessarily be advantageous for performance.

Muscle Contraction↗

Coding for Parallel Links to Maximize the Expected Value of Decodable Messages

When multiple parallel communication links are available, it is useful to consider link-utilization strategies that provide tradeoffs between reliability and throughput. Interesting cases arise when there are three or more available links. Under the model considered, the links have known probabilities of being in working order, and each link has a known capacity. The sender has a number of messages to send to the receiver. Each message has a size and a value (i.e., a worth or priority). Messages may be divided into pieces arbitrarily, and the value of each piece is proportional to its size. The goal is to choose combinations of messages to send on the links so that the expected value of the messages decodable by the receiver is maximized. There are three parts to the innovation: (1) Applying coding to parallel links under the model; (2) Linear programming formulation for finding the optimal combinations of messages to send on the links; and (3) Algorithms for assisting in finding feasible combinations of messages, as support for the linear programming formulation. There are similarities between this innovation and methods developed in the field of network coding. However, network coding has generally been concerned with either maximizing throughput in a fixed network, or robust communication of a fixed volume of data. In contrast, under this model, the throughput is expected to vary depending on the state of the network. Examples of error-correcting codes that are useful under this model but which are not needed under previous models have been found. This model can represent either a one-shot communication attempt, or a stream of communications. Under the one-shot model, message sizes and link capacities are quantities of information (e.g., measured in bits), while under the communications stream model, message sizes and link capacities are information rates (e.g., measured in bits/second). This work has the potential to increase the value of data returned from spacecraft under certain conditions.

Klimesh, Matthew A.↗

Improving the Accuracy of Predicting Maximal Oxygen Consumption (VO2pk)

Maximal oxygen (VO2pk) is the maximum amount of oxygen that the body can use during intense exercise and is used for benchmarking endurance exercise capacity. The most accurate method to determineVO2pk requires continuous measurements of ventilation and gas exchange during an exercise test to maximal effort, which necessitates expensive equipment, a trained staff, and time to set-up the equipment. For astronauts, accurate VO2pk measures are important to assess mission critical task performance capabilities and to prescribe exercise intensities to optimize performance. Currently, astronauts perform submaximal exercise tests during flight to predict VO2pk; however, while submaximal VO2pk prediction equations provide reliable estimates of mean VO2pk for populations, they can be unacceptably inaccurate for a given individual. The error in current predictions and logistical limitations of measuring VO2pk, particularly during spaceflight, highlights the need for improved estimation methods.

Downs, Meghan E.↗

Gate Drive Technology Evaluation and Development to Maximize Switching Speed of SiC Discrete Devices and Power Modules in Hard Switching Applications

To understand the limitation of maximizing the switching speed of SiC low current discrete devices and high current power modules in hard switching applications, double pulse tests are conducted and the testing results are analyzed. For power modules, the switching speed is generally limited by the parasitics rather than the gate drive capability. For the discrete SiC device, the conventional voltage source gate drive (VSG) is not sufficient to maximize the switching speed even if the external gate resistance is minimized. The limitation of existing current source gate drives (CSG) are analyzed, and a CSG dedicated for SiC discrete devices is proposed, which can provide constant current during the switching transient regardless of the high Miller voltage and large internal gate resistance. Compared with the conventional VSG, the proposed CSG achieves 67% faster turnon time and 50% turn-off time, and 68% reduction in switching loss at full load condition.

Handong Gui↗

The PIAA-Vortex Coronagraph: A New Coronagraph Technology to Maximize Exo-Earth Yields in the Astro2020 Era

Detecting and characterizing the atmospheres of terrestrial exoplanets is a main goal of the IR/O/UV flagship mission recommended by the Astro2020 Report. Achieving this goal depends critically on developing coronagraph technology that maximizes the potential number of terrestrial exoplanets we predict we can characterize, i.e. the exoEarth yield. Stringent constraints on low-order aberration sensitivity, inner working angle, and throughput as a function of telescope pupil complexity have been one of the main limiting factors affecting the yield of coronagraphs, and is a driving factor for telescope design considerations such as whether to use an off-axis or on-axis architecture. We present a hybrid PIAA-Vortex coronagraph concept that relaxes many of these constraints, and makes on-axis telescopes with centrally obstructed pupils a viable region of the design trade-space for the IR/O/UV flagship. Using the LUVOIR-A pupil as a baseline to design around, we present a coronagraph architecture with a small, ~2.5 lambda/D working angle that is insensitive to tip/tilt aberrations and stellar angular diameters on the order of 0.1 lambda/D. Pupil-plane apodization is achieved with PIAA-style mirror apodizations we obtain using a formalism we have developed to simultaneously optimize the contrast and low-order aberration sensitivity of coronagraphs designed for arbitrary telescope pupils and dark-hole geometries. By using PIAA to apodize in the pupil plane, the PIAA-Vortex coronagraph mitigates the trade-off between planet throughput, IWA, and aberration sensitivity, resulting in significantly higher yields for coronagraphs on obstructed pupils and new opportunities to maximize our ability to detect biomarkers in the Astro2020 era.

Kevin Fogarty↗

A Joinable Undercarriage to Maximize Payload (JUMP) Lunar Lander for Cargo Delivery to the Lunar Surface

Currently, NASA has engaged industry to develop a series of small to medium capacity landers with payload capacities of up to 5-9 tons by the mid to late 2020s. This contrasts with the former Constellation program, where the Altair lunar lander was targeting a payload capability of roughly 14-20 tons. Investment in smaller landers may present future challenges in delivering habitat modules larger than lunar lander cabins or small logistics modules to the lunar surface. Additionally, given a projected SLS flight rate of 1-2 launches per year, a lunar surface buildup from small elements seems problematic at best. While commercial launchers provide a supplement to SLS, many of the current and projected launch vehicles deliver less than 20 tons to a Trans-Lunar Injection – even fewer to the lunar surface. However, a possible solution could emerge if the lander itself could be launched in pieces with a buildup in Cislunar space. Thus, launchers with these capacities could contribute to a lunar lander capable of delivering 30 tons or more to the lunar surface. This paper introduces the notional concept of a Joinable Undercarriage to Maximized Payload (JUMP) lander. Key elements of a proposed JUMP lander concept will be discussed, followed by recommendations and forward work.

Human spaceflight↗