Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spectral Analysis of Integrated Pressures on Patches with Unsteady Pressure-Sensitive Paint Measurements

This paper describes the spectral analysis of integrated pressures on patches of the scale model of the Space Launch System (SLS) Block 1B crew vehicle with the Unsteady Pressure-Sensitive Paint (uPSP) measurements, which were collected in the ascent transient aerodynamics tests with the Unitary Plan Wind Tunnel 11-by-11-foot Transonic Wind Tunnel in September 2019 at NASA Ames Research Center. Recent research has demonstrated that uPSP can be an essential tool for the assessment of the unsteady, aerodynamic phenomena. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. In this paper, 108 patches are defined with x station values and azimuth angles of the scale model. For each patch, the polygons are determined from the surface cells of the grid of the model, clipped with the edges of the patch, and each of the polygons is divided into triangles. The inputs of the pressure integration algorithm are the time series of pressure coefficients on the vertices of the grid of the model, generated by the uPSP data processing program from the videos taken with 4 Phantom high-speed cameras during the wind tunnel tests. The integrated pressure of the patch is determined as the ratio of the sum of the forces on the triangles over the sum of the areas of the triangles. For each of the test cases, the Cross Power Spectral Density (CPSD) and Magnitude-Squared Coherence (msCohere) are computed for frequencies over 1/3 octave bands from the time series of the integrated pressures on the patches. The spectral analysis outputs of different cases of the wind tunnel tests are analyzed and the coherence of patches is investigated over frequencies, x station values, azimuth angles, Mach numbers and SLS vehicle attitudes. The pressure integration and spectral analysis described in this paper were executed on the NASA Pleiades supercomputer. Funding for this research was provided by the NASA Aeroscience Evaluation and Test Capabilities (AETC) Project.

Pressure-Sensitive Paint↗

Pressure Sensitive Paint Measurements on 15% Scale Rotor Blades in Hover

This paper describes a proof of concept test to examine the feasibility of using pressure sensitive paint (PSP) to measure the pressure distributions on a rotor in hover. The test apparatus consisted of the US Army 2-meter Rotor Test Stand (2MRTS) and 15% scale swept tip rotor blades. Two camera/rotor separations were examined: 0.76 and 1.35 radii. The outer 15% of each blade was painted with PSP. Intensity and lifetime based PSP measurement techniques were attempted. Data were collected from all blades at thrust coefficients ranging from 0.004 to 0.009.

Wong, Oliver D.↗

Dynamic Mode Decomposition of Unsteady Pressure-Sensitive Paint Measurements for the NASA Unitary Plan Wind Tunnel Tests

This paper describes the Dynamic Mode Decomposition (DMD) of the pressures on the scale model of the Space Launch System (SLS) Block 1 cargo vehicle with the Unsteady Pressure-Sensitive Paint (uPSP) measurements, which were collected in the Ascent Transient Aerodynamics Tests with the Unitary Plan Wind Tunnel 11-by-11-foot Transonic Wind Tunnel in September 2019 at NASA Ames Research Center. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. The conventional DMD algorithm is based on the Singular Value Decomposition (SVD) of the data matrix. For the matrix of the uPSP measurements of the SLS ATAT, the number of rows is equal to the number of nodes in the grid of the scale model, and the number of columns is equal to the number of frames in the videos taken with 4 Phantom high-speed cameras. In this paper, it is verified that, for the time series with zero mean value, the DMD is equivalent to the decomposition with the Discrete Fourier Transform (DFT). Considering the uPSP is mainly used in the assessment of the unsteady, aerodynamic phenomena, the DMD of the uPSP measurements can be implemented in two steps: (1) subtract the mean value from the uPSP measurement on each of the grid nodes; (2) apply the Fast Fourier Transform (FFT) on the resulting zero-mean time series. The DMD of the uPSP measurements with FFT has two advantages: (1) the computational complexity of FFT is O(N*logN), where N is the length of the time series; (2) compared to the SVD-based DMD algorithm, the DMD with FFT can be easily implemented in parallel processing. A sample matrix of uPSP measurements, at the size of 341 grid nodes and 128 frames, is generated. Figures 1 and 2 show the eigenvalues and the ratios of the eigenvectors, respectively, of the sample matrix, without and with the mean value removed on each of the grid nodes, computed with the SVD-based DMD and the FFT. The figures demonstrate the equivalence of the SVD-based DMD and the decomposition with DFT/FFT for the time series with zero mean value. The results of DMD of the uPSP measurements of the SLS ATAT in September 2019 are presented in the paper. The DMD modes at different frequencies are shown, the aerodynamic phenomena (e.g. shockwave and vortex shedding) are demonstrated and the correlation of the DMD modes with the test configuration parameter (e.g., the Mach Number) is discussed. Figure 3 shows a software tool to visualize the DMD modes. The code to implement the algorithm described in this paper was written in C, with libraries of FFTW for FFT and MPI/OpenMP for parallel processing, and executed on the NASA Pleiades supercomputer. Funding for this research was provided by the NASA Aerosciences Evaluation and Test Capabilities Project.

Pressure-Sensitive Paint↗

Pressure-sensitive paint measurements on a supersonic high-sweep oblique wing model

The pressure-sensitive paint method was used in the test of a high-sweep oblique wing model, conducted in the NASA Ames 9- by 7-ft Supersonic Wind Tunnel. Surface pressure data was acquired from both the luminescent paint and conventional pressure taps at Mach numbers between M = 1.6 and 2.0. In addition, schlieren photographs of the outer flow were used to determine the location of shock waves impinging on the model. The results show that the luminescent pressure-sensitive paint can capture both global and fine features of the static surface pressure field. Comparison with conventional pressure tap data shows good agreement between the two techniques, and that the luminescent paint data can be used to make quantitative measurements of the pressure changes over the model surface. The experiment also demonstrates the practical considerations and limitations that arise in the application of this technique under supersonic flow conditions in large-scale facilities, as well as the directions in which future research is necessary in order to make this technique a more practical wind-tunnel testing tool.

McLachlan, B. G.↗

The Georgia Tech High Sensitivity Microwave Measurement System

As observations and models of the planets become increasingly more accurate and sophisticated, the need for highly accurate laboratory measurements of the microwave properties of the component gases present in their atmospheres become ever more critical. This paper describes the system that has been developed at Georgia Tech to make these measurements at wavelengths ranging from 13.3 cm to 1.38 cm with a sensitivity of 0.05 dB/km at the longest wavelength and 0.6 db/km at the shortest wavelength.

Deboer, David R.↗

Optical Modem Enabling Broadband Datacom Links for Crewed Cis-Lunar Missions

We report on the design, development, and testing of our high-power broadband optical modem supporting NASA’s crewed Artemis-2 mission. The O2O modem will be mounted in the crewed Orion module and provide a broadband 505,000 km bi-directional optical link back to earth while en route to the moon. The full-duplex modem consists of a high-power optical transmitter and receiver optimized for serially-concatenated pulse-position modulation (SCPPM). The transmitter is a master-oscillator power-amplifier optical architecture using efficient cladding-pumped amplification in erbium-ytterbium co-doped fiber. The transmitter outputs up to 1 W at ≈1550 nm (limited for eye safety) and supports 6 different user-rates ranging from 20.39 Mb/s to 260.95 Mb/s using PPM16 and PPM32 modulation formats. The optical receiver supports two user-rates: 10.19 Mb/s and 20.39 Mb/s with both rates employing PPM32. The narrowband receiver filtering is optimized to simultaneously accept four separate wavelength channels to mitigate atmospherics through spatial diversity. A configurable interleaver provides additional protection against atmospherics-based signal fading and a powerful soft-decision error correction scheme enables highly sensitive detection. The measured sensitivities at the two bit-rates are -73.8 and -71.8dBm, respectively. The architecture was designed for reliable operation in space, featuring automatic hardware interlocks, pump sparing for the amplifiers, and autonomous operation of all internal hardware and software control loops. The protoflight unit (PFU) was put through rigorous environmental testing which included pyroshock, vibration, electromagnetic interference/compatibility, and thermal-vacuum testing. The modem successfully passed all the environmental screening and has been declared at Technology Readiness Level (TRL) 6.

space communications↗

Unified Application Vapor Screen Flow Visualization and Pressure Sensitive Paint Measurement Techniques to Vortex- and Shock Wave-Dominated Flow Fields

Laser vapor screen (LVS) flow visualization and pressure sensitive paint (PSP) techniques were applied in a unified approach to wind tunnel testing of slender wing and missile configurations dominated by vortex flows and shock waves at subsonic, transonic, and supersonic speeds. The off-surface cross-flow patterns using the LVS technique were combined with global PSP surface static pressure mappings to characterize the leading-edge vortices and shock waves that coexist and interact at high angles of attack (alpha). The synthesis of LVS and PSP techniques was also effective in identifying the significant effects of passive surface porosity and the presence of vertical tail surfaces on the flow topologies. An overview is given of LVS and PSP applications in selected experiments on small-scale models of generic slender wing and missile configurations in the NASA Langley Research Center (NASA LaRC) Unitary Plan Wind Tunnel (UPWT) and 8-Foot Transonic Pressure Tunnel (8-Foot TPT).

Erickson, Gary E.↗

Unified Application of Vapor Screen Flow Visualization and Pressure Sensitive Paint Measurement Techniques to Vortex- and Shock Wave-Dominated Flow Fields

Laser vapor screen (LVS) flow visualization and pressure sensitive paint (PSP) techniques were applied in a unified approach to wind tunnel testing of slender wing and missile configurations dominated by vortex flows and shock waves at subsonic, transonic, and supersonic speeds. The off-surface cross-flow patterns using the LVS technique were combined with global PSP surface static pressure mappings to characterize the leading-edge vortices and shock waves that coexist and interact at high angles of attack. The synthesis of LVS and PSP techniques was also effective in identifying the significant effects of passive surface porosity and the presence of vertical tail surfaces on the flow topologies. An overview is given of LVS and PSP applications in selected experiments on small-scale models of generic slender wing and missile configurations in the NASA Langley Research Center (NASA LaRC) Unitary Plan Wind Tunnel (UPWT) and 8-Foot Transonic Pressure Tunnel (8-Foot TPT).

Erickson, Gary E.↗

Investigation, development and application of optimal output feedback theory. Vol. 4: Measures of eigenvalue/eigenvector sensitivity to system parameters and unmodeled dynamics

Some measures of eigenvalue and eigenvector sensitivity applicable to both continuous and discrete linear systems are developed and investigated. An infinite series representation is developed for the eigenvalues and eigenvectors of a system. The coefficients of the series are coupled, but can be obtained recursively using a nonlinear coupled vector difference equation. A new sensitivity measure is developed by considering the effects of unmodeled dynamics. It is shown that the sensitivity is high when any unmodeled eigenvalue is near a modeled eigenvalue. Using a simple example where the sensor dynamics have been neglected, it is shown that high feedback gains produce high eigenvalue/eigenvector sensitivity. The smallest singular value of the return difference is shown not to reflect eigenvalue sensitivity since it increases with the feedback gains. Using an upper bound obtained from the infinite series, a procedure to evaluate whether the sensitivity to parameter variations is within given acceptable bounds is developed and demonstrated by an example.

Halyo, Nesim↗

Pursuit Latency for Chromatic Targets

The temporal dynamics of eye movement response to a change in direction of stimulus motion has been used to compare the processing speeds of different types of stimuli (Mulligan, ARVO '97). In this study, the pursuit response to colored targets was measured to test the hypothesis that the slow response of the chromatic system (as measured using traditional temporal sensitivity measures such as contrast sensitivity) results in increased eye movement latencies. Subjects viewed a small (0.4 deg) Gaussian spot which moved downward at a speed of 6.6 deg/sec. At a variable time during the trajectory, the dot's direction of motion changed by 30 degrees, either to the right or left. Subjects were instructed to pursue the spot. Eye movements were measured using a video ophthalmoscope with an angular resolution of approximately 1 arc min and a temporal sampling rate of 60 Hz. Stimuli were modulated in chrominance for a variety of hue directions, combined with a range of small luminance increments and decrements, to insure that some of the stimuli fell in the subjects' equiluminance planes. The smooth portions of the resulting eye movement traces were fit by convolving the stimulus velocity with an exponential having variable onset latency, time constant and amplitude. Smooth eye movements with few saccades were observed for all stimuli. Pursuit responses to stimuli having a significant luminance component are well-fit by exponentials having latencies and time constants on the order of 100 msec. Increases in pursuit response latency on the order of 100-200 msec are observed in response to certain stimuli, which occur in pairs of complementary hues, corresponding to the intersection of the stimulus section with the subjects' equiluminant plane. Smooth eye movements can be made in response to purely chromatic stimuli, but are slower than responses to stimuli with a luminance component.

Mulligan, Jeffrey B.↗

An all-silicon single-wafer micro-g accelerometer with a combined surface and bulk micromachining process

This paper reports an all-silicon fully symmetrical z-axis micro-g accelerometer that is fabricated on a single-silicon wafer using a combined surface and bulk fabrication process. The microaccelerometer has high device sensitivity, low noise, and low/controllable damping that are the key factors for attaining micro g and sub-micro g resolution in capacitive accelerometers. The microfabrication process produces a large proof mass by using the whole wafer thickness and a large sense capacitance by utilizing a thin sacrificial layer. The sense/feedback electrodes are formed by a deposited 2-3 microns polysilicon film with embedded 25-35 microns-thick vertical stiffeners. These electrodes, while thin, are made very stiff by the thick embedded stiffeners so that force rebalancing of the proof mass becomes possible. The polysilicon electrodes are patterned to create damping holes. The microaccelerometers are batch-fabricated, packaged, and tested successfully. A device with a 2-mm x 1-mm proof mass and a full bridge support has a measured sensitivity of 2 pF/g. The measured sensitivity of a 4-mm x 1-mm accelerometer with a cantilever support is 19.4 pF/g. The calculated noise floor of these devices at atmosphere are 0.23 micro g/sqrt(Hz) and 0.16 micro g/sqrt(Hz), respectively.

Non-NASA Center↗

Spatiotemporal Analysis of High-Resolution Pressure-Sensitive Paint Measurements on a Launch Vehicle Wind Tunnel Model

An accurate understanding of unsteady aerodynamic loads is critical for launch vehicle structural design and for development of the vibro-acoustic environment for payload components. Analysts commonly use point-wise surface pressure measurements from wind tunnel testing to build statistical models of the in-flight turbulent boundary layer flow structures, often extrapolating over large swaths of the surface due to measurement sparsity. We present novel results from a transonic wind tunnel test using fast-response pressure-sensitive paint (PSP) and show how it can be used to visualize and quantify localized turbulent boundary layer wall pressure statistics with unprecedented spatial resolution. The wind tunnel model is a scaled model of the Space Launch System (SLS) rocket Block 1B Crew configuration and analysis focused on the compression corner between the Service Module fairing and the Universal Stage Adapter.

Corcos Model↗

Digitally Enhanced Heterodyne Interferometry

Spurious interference limits the performance of many interferometric measurements. Digitally enhanced interferometry (DEI) improves measurement sensitivity by augmenting conventional heterodyne interferometry with pseudo-random noise (PRN) code phase modulation. DEI effectively changes the measurement problem from one of hardware (optics, electronics), which may deteriorate over time, to one of software (modulation, digital signal processing), which does not. DEI isolates interferometric signals based on their delay. Interferometric signals are effectively time-tagged by phase-modulating the laser source with a PRN code. DEI improves measurement sensitivity by exploiting the autocorrelation properties of the PRN to isolate only the signal of interest and reject spurious interference. The properties of the PRN code determine the degree of isolation.

Shaddock, Daniel↗

Ground Testing of 2-µm Triple-Pulse IPDA Lidar for Carbon Dioxide and Water Vapor Measuremets

A triple-pulse, 2-µm, Integrated Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center. This active remote sensing instrument provides a technique for measuring atmospheric carbon dioxide and water vapor simultaneously and independently. A 2-µm high-energy pulsed laser is incorporated for the IPDA transmitter, which provides high signal-to-noise ratio measurements using a commercial direct detection system. This results in a high-precision measurement capability for the low troposphere weighted-average column dry-air volume mixing ratio of the gases. Recent IPDA ground testing indicated carbon dioxide and water vapor measurements sensitivities of 8% and 14%, respectively and biases of 0.1%. However, using the R30 centerline position for the on-line enhances the CO2 measurement sensitivity to 0.6%.

Refaat, Tamer F.↗

Remote sensing of atmospheric SO2 using the differential absorption LIDAR technique

The paper reports an investigation of the capabilities of a UV differential absorption lidar (DIAL) system for remote measurements of sulfur dioxide emissions. Two features of the present DIAL system are an absorption cell permitting the determination of the difference in SO2 absorption coefficients for the two transmitted wavelengths and a calibration cell permitting the linearity and performance of the system to be evaluated. The DIAL technique is described along with the transmitter, receiver, data-adquisition, and data-processing components of the investigated system. Quantitative measurements of the average SO2 concentration in a region surrounding the exhaust stack of a steam-generating plant are discussed which show that the present system has measurement sensitivities of 10 ppb at a range of 0.8 km and 20 ppb at 1.9 km. Based on performance characteristics obtained during a calibration of this system, it is predicted that a measurement sensitivity of less than 4 ppb over a 1-km path will be attained.

Hoell, J. M., Jr.↗

SXRP - An X-ray polarimeter for the SPECTRUM-X-Gamma mission

The Stellar X-ray Polarimeter (SXRP) is a focal plane instrument which will be flown on the SPECTRUM-X-Gamma mission in 1993. The polarimeter is composed of two separate instruments: the first exploits the dependence on the polarization of the Bragg reflection from a graphite crystal, and of the Thomson scattering from a metallic lithium target. The second instrument makes use of the recently discovered polarization dependence of X-ray photoemission from CsI. The SXRP will permit sensitive measurements of several classes of galactic X-ray sources, such as X-ray pulsars, black-hole candidates and supernova remnants. Moreover, and for the first time, SXRP will be able to perform highly sensitive measurements of the brightest extragalactic sources.

Costa, E.↗

Interferometric Testbed for Nanometer Level Stabilization of Environmental Motion Over Long Timescales

We developed an interferometric testbed to stabilize environmental motions over timescales of several hours and a lengthscale of 1m. Typically, thermal and seismic motions on the ground are larger than 1 micron over these scales, affecting the precision of more sensitive measurements. To suppress such motions, we built an active stabilization system composed of interferometric sensors, a hexapod actuator, and a frequency stabilized laser. With this stabilized testbed, environmental motions were suppressed down to nm level. This system will allow us to perform sensitive measurements, such as ground testing of LISA (Laser Interferometer Space Antenna), in the presence of environmental noise.

Numata, Kenji↗