Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improvements in Optical Surface Measurement Using Reflected Computer Vision Targets

Since 2021, NREL has been developing a system to measure heliostats by measuring the deflection of printed computer vision targets, called the Reflected Target Non-intrusive Assessment (ReTNA) [6], [7]. While this system will have lower resolution than a fringe deflectometry system, it has several important advantages that make it a complimentary technology: 2D surface slope measurement can be generated from a single image, it can operate in ambient lighting, target points can be directly located in 3D space with photogrammetry allowing for a non-flat target, and it's well suited to using a smaller target, and multiple images to measure larger optical surfaces. ReTNA has undergone several significant changes and improvements, described below. This talk will summarize new system layouts designed for commercial use, new computer vision algorithms used to automate the analysis process and validation campaigns for the ReTNA software.

computer vision↗

Influences of lidar scanning parameters on wind turbine wake retrievals in complex terrain

Abstract. Scanning lidars enable the collection of spatially distributed measurements of turbine wakes and the estimation of wake properties such as magnitude, extent, and trajectory. Lidar-based characterizations, however, may be subject to distortions due to the observational system. Distortions can arise from the resolution of the measurement points across the wake, the projection of the winds onto the beam, averaging along the beam probe volume, and intervening evolution of the flow over the scan duration. Using a large-eddy simulation and simulated measurements with a virtual lidar model, we assess how scanning lidar systems may influence the properties of the retrieved wake using a case study from the Perdigão campaign. We consider three lidars performing range-height indicator sweeps in complex terrain, based on the deployments of lidars from the Danish Technical University (DTU) and German Aerospace Center (DLR) at the Perdigão site. The unwaked flow, measured by the DTU lidar, is well-captured by the lidar, even without combining data into a multi-lidar retrieval. The two DLR lidars measure a waked transect from different downwind vantage points. In the region of the wake, the observation system reacts to the smaller spatial and temporal variations of the winds, allowing more significant observation distortions to arise. While the measurements largely capture the wake structure and trajectory over its 4–5 D extent, limited spatial resolution of measurement points and volume averaging lead to a quicker loss of the two lobes in the near wake, smearing of the vertical bounds of the wake (< 30 m), wake center displacements up to 10 m, and dampening of the maximum velocity deficit by up to a third. The virtual lidar tool, coupled with simulations, provides a means for assessing measurement capabilities in advance of measurement campaigns.

17 WIND ENERGY↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Field Evaluation of the High Efficiency Dehumidification System (HEDS) at the Timken Museum of Art - Summary of Measurement and Verification (M&V) Results from Summer 2023

The National Renewable Energy Laboratory (NREL) is performing a measurement and verification (M&V) assessment of the Conservant High Efficiency Dehumidification System (HEDS) at the Timken Museum of Art in San Diego, California. The HEDS was selected for evaluation by the U.S. Department of Energy (DOE) High Impact Technology Catalyst (HIT) evaluation program in 2022. This report documents recently completed analysis of data collected as an initial assessment of the HEDS system performance. Data was collected for the summer M&V during several weeks in August and September 2023 while operating the Timken Museum's HVAC system in several operating modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components

Introduction Bioelectrical impedance analysis (BIA) systems are gaining popularity for use in research and fitness assessments as the technology improves and becomes more affordable and easier to use. Multifrequency BIA (MF-BIA) may improve accuracy and precision using octopolar contacts for segmental analyses. Purpose Evaluate reliability, biological variability, and accuracy of component measures (total body water, mass, and composition) of commercially available MF-BIA system (InBody 770, Cerritos, California, USA). Methods Fourteen healthy military-age adults were assessed by MF-BIA in duplicate on five laboratory visits across 3 weeks (10 measures each). Participants were evaluated at the same time of day after refraining from strenuous exercise (> 48 h), alcohol consumption (> 24 h), and caffeine, nicotine, and food (> 10 h). Systematic error (test–retest reliability) and biological variability (day-to-day reliability) were summarized by intraclass correlation coefficient (ICC) values determined for body mass (fat, fat-free, total) and body water (extracellular, intracellular, total). Body composition measurements derived from BIA on the second visit were also tested for accuracy compared to dual-energy x-ray absorptiometry (DXA). Results Test–retest reliability was very high for all measurements of whole-body water and mass (ICC ≥ 0.999) and high for regional body water and mass (ICC 0.973–1.000). Biological variability was observable with very minor differences between tests (same day) for total and regional body water (0.0–0.2 L) and total and regional body mass measurements (0.0–0.2 kg); while between day differences were slightly higher (0.0–0.5 L and 0.1–0.7 kg). Compared to DXA, the MF-BIA whole-body measures showed an offset in %BF (Bias −4.0 ± 2.8%; Standard error of the estimate (SEE), 2.6%), an overprediction for total body fat-free mass (Bias 2.8 ± 2.1 kg; SEE 2.2 kg) and an underprediction of total body fat mass (Bias −2.9 ± 2.0 kg; SEE 1.9 kg). Conclusion Under controlled conditions with fit and healthy men and women, this MF-BIA system has high methodological reliability and demonstrates stable day-to-day measurements of major body composition components. Previously reported ~3% body fat offset compared to criterion methods was again confirmed. Precision of the InBody 770 shows consistency and supports further testing of this specific device as a new military standards method and suitability across a wider range of %BF.

Nutrition & Dietetics↗

Review of Ultrasonic Methods for Monitoring, Damage Detection, and Processing of Lithium-Ion Batteries Throughout Their Life Cycle

Lithium-ion batteries (LIBs) are the leading technology used in consumer electronics, electric vehicles, and grid-level electrochemical energy storage applications. The ever-increasing use of LIBs has highlighted a gap in understanding of their behavior throughout their life cycle. Current monitoring systems rely on electrical and sometimes temperature measurements to assess the internal state which limits information about complex electrochemical processes. In response, ultrasonic testing (UT) has shown promise for non-invasive assessment due to its ease of use and sensitivity to mechanical changes which are correlated with electrochemical changes within the battery. We summarize the research in UT methods applied to LIBs throughout their life cycle. We also discuss physics-based and data-driven modeling approaches used to interpret ultrasonic signals in the context of LIBs, with an emphasis on the existing challenge of establishing rigorous links between electrochemical behavior and elastic and poroelastic wave physics to gain insight regarding physical changes in the LIB that can be directly measured using UT. Finally, we discuss the challenges of implementing UT across the LIB life cycle and identify opportunities for further research. This review aims to provide helpful guidance to researchers and practitioners of UT in the growing field of UT for electrochemical battery systems.

25 ENERGY STORAGE↗

Robust Power System Stability Assessment Against Adversarial Machine Learning-Based Cyberattacks via Online Purification

The increasing complexity associated with renewable generation brings more challenges to power system stability assessment (SA). Data-driven approaches based on machine learning (ML) techniques for stability assessment have received significant research interest and shown their promising performance. However, ML-based models are recognized to be vulnerable to adversarial disturbances, where a slight perturbation to power system measurements could lead to unacceptable errors. To address this issue, this paper develops a novel lightweight mitigation strategy, i.e., robust online stability assessment (ROSA), to enhance the ML-based assessment model against both white-box and the black-box adversarial disturbances (i.e., purification) in the online implementation. The ROSA involves a supervised learning-based module for the primary stability assessment and a self-supervised learning-based module. Further, the two modules are trained jointly with different objective (loss) functions and implemented in sequence. A suitable purification objective and various time-series data augmentation methods are designed for SA applications to tackle adversarial disturbances adaptively. Case studies are performed, and the comparative results have clearly illustrated the competitive, robust accuracy against various adversarial scenarios and verified the effectiveness of the proposed online purification strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying a science‐based systems perspective to dispel misconceptions about climate effects of forest bioenergy

Abstract The scientific literature contains contrasting findings about the climate effects of forest bioenergy, partly due to the wide diversity of bioenergy systems and associated contexts, but also due to differences in assessment methods. The climate effects of bioenergy must be accurately assessed to inform policy‐making, but the complexity of bioenergy systems and associated land, industry and energy systems raises challenges for assessment. We examine misconceptions about climate effects of forest bioenergy and discuss important considerations in assessing these effects and devising measures to incentivize sustainable bioenergy as a component of climate policy. The temporal and spatial system boundary and the reference (counterfactual) scenarios are key methodology choices that strongly influence results. Focussing on carbon balances of individual forest stands and comparing emissions at the point of combustion neglect system‐level interactions that influence the climate effects of forest bioenergy. We highlight the need for a systems approach, in assessing options and developing policy for forest bioenergy that: (1) considers the whole life cycle of bioenergy systems, including effects of the associated forest management and harvesting on landscape carbon balances; (2) identifies how forest bioenergy can best be deployed to support energy system transformation required to achieve climate goals; and (3) incentivizes those forest bioenergy systems that augment the mitigation value of the forest sector as a whole. Emphasis on short‐term emissions reduction targets can lead to decisions that make medium‐ to long‐term climate goals more difficult to achieve. The most important climate change mitigation measure is the transformation of energy, industry and transport systems so that fossil carbon remains underground. Narrow perspectives obscure the significant role that bioenergy can play by displacing fossil fuels now, and supporting energy system transition. Greater transparency and consistency is needed in greenhouse gas reporting and accounting related to bioenergy.

54 ENVIRONMENTAL SCIENCES↗

Secure and Cost-Effective Micro Phasor Measurement Unit (PMU)-Like Metering for Behind-the-Meter (BTM) Solar Systems using Blockchain-Assisted Smart Inverters

Recently, there is increasing interest in using behind-the-meter (BTM) solar systems for grid services. However, providing visibility and operational situational awareness of BTM solar systems mainly operated by small-scale solar inverters is challenging due to the requirement of relatively expansive networked observation tools (e.g., micro phasor measurement units (µPMUs)) and consequent cybersecurity threats through networks. This paper presents a secure, cost-effective, µPMUs-like metering method using a blockchain-assisted smart (BAS) inverters for a BTM solar system. The proposed BAS inverter consisting of an internet of things device as a node of a local blockchain network enables the secure provision of inverter measurement data for grid services. The BAS inverter sends the encrypted local measurement data with a timestamp to a local blockchain miner. Once the blockchain miner generates a tamper-resistant metering ledger including the measurements, it is used to assess the situational awareness of the BTM solar system. The concept of the proposed metering using the BAS inverters is validated by experimental studies.

behind the meter↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗

Secure and Cost-Effective Micro Phasor Measurement Unit (PMU)-Like Metering for Behind-the-Meter (BTM) Solar Systems Using Blockchain-Assisted Smart Inverters: Preprint

Recently, there is increasing interest in using behind-the-meter (BTM) solar systems for grid services. However, providing visibility and operational situational awareness of BTM solar systems mainly operated by small-scale solar inverters is challenging due to the requirement of relatively expansive networked observation tools (e.g., micro phasor measurement units (uPMUs)) and consequent cybersecurity threats through networks. This paper presents a secure, cost-effective, uPMUs-like metering method using a blockchain-assisted smart (BAS) inverters for a BTM solar system. The proposed BAS inverter consisting of an internet-of-things device as a node of a local blockchain network enables the secure provision of inverter measurement data for grid services. The BAS inverter sends the encrypted local measurement data with a timestamp to a local blockchain miner. Once the blockchain miner generates a tamper-resistant metering ledger including the measurements, it is used to assess the situational awareness of the BTM solar system. The concept of the proposed metering using the BAS inverters is validated by experimental studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP↗

A multilayer multi-configurational approach to efficiently simulate large-scale circuit-based quantum computers on classical machines

Here, a multilayer multi-configurational theory framework is adapted to simulate circuit-based quantum computers. Quantum addition of superpositions of an exponential number of summands is performed in polynomial time with high accuracy. We demonstrate numerically accurate calculations including up to one million qubits for entangling benchmarks. Simulation cost can be assessed by entropy-based entanglement measures. For the considered systems, we show that the entanglement only grows weakly with the system size. The present simulations demonstrate how quantum algorithms in low-entropy regimes can be used efficiently on classically simulated quantum computers.

97 MATHEMATICS AND COMPUTING↗

Queued Up: 2025 Edition – Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2024 [Slides]

Electric transmission system operators (ISOs, RTOs, or utilities) require proposed power plants seeking to connect to the transmission grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. The lists of projects in this process are known as “interconnection queues”. In collaboration with interconnection.fyi, Berkeley Lab compiled, aggregated, and cleaned interconnection queue data from >50 transmission grid operators (7 ISO/RTOs and 49 non-ISO balancing areas), which collectively represent ~97% of currently installed U.S. electric generating capacity. The dataset includes requests submitted to queues through the end of 2024, and only includes requests seeking to connect to the transmission grid (not distribution-connected or behind-the-meter projects). The files below include both a PDF report and an Excel data file. The PDF report analyzes interconnection data and metrics through the end of 2024. The Excel data file includes (a) the full project-level interconnection queue dataset through 2024, (b) a codebook (data dictionary) describing each data field, and (c) 35 additional tabs featuring tables summarizing a range of interconnection metrics. Key highlights from the Queued Up: 2025 Edition (featuring data through 2024) include: • As of the end of 2024, there were ~10,300 projects actively seeking grid interconnection in the U.S., representing 1,400 GW of generation and approximately 890 GW of storage. • Historic withdrawal rates alongside relatively fewer new requests resulted in a 12% decrease in total active queue volume compared to the prior year. • Active natural gas capacity (136 GW, +72% year-over-year) increased in 2024, while solar (956 GW, -12%), storage (890 GW, -13%), and wind (271 GW, -26%) capacity decreased. • 408 GW of capacity already has a draft or executed interconnection agreement (IA) but has not yet reached commercial operations. • The time projects spend in queues before reaching COD is increasing. For the regions with available data, the median duration from IR to COD has doubled from <2 years for projects built in 2000-2007 to over 4 years for those built in 2018-2024. • Ultimately, most of this proposed capacity will not be built. Only 13% of capacity that submitted interconnection requests from 2000-2019 had reached commercial operations by the end of 2024; 77% of that capacity had been withdrawn and 10% was still active. • FERC Order 2023 and various other reforms are being implemented. These are important measures to reduce interconnection bottlenecks and enhance grid system reliability, but it is too early to measure and assess their full impact. • New additions for the 2025 edition include: (a) additional detail on data processing and gaps; (b) updates on interconnection reforms; (c) new analysis on interconnection agreements, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗