Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical coolers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3

High-Burnup LOCA Burst Susceptibility BISON Analysis in PWRs and BWRs

Accurately assessing high-burnup fuel behavior during loss-of-coolant accidents (LOCAs) is essential for understanding fuel fragmentation, relocation, and dispersal (FFRD) risks across the US light-water reactor fleet. This work updates previous Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program multiphysics LOCA analyses for a pressurized water reactor (PWR) and a boiling water reactor (BWR) by incorporating recent model and material property advancements in the BISON fuel performance code, including a high-burnup structure (HBS) model, revised cladding burst criteria, and updated thermal–mechanical correlations. This update was needed to support ongoing industry initiatives and upcoming regulatory changes. Full-core, rod-resolved operating histories generated using Virtual Environment for Reactor Analysis (VERA) and system-level LOCA conditions obtained from TRACE were applied to statistically representative rod samples in BISON to evaluate burst behavior and FFRD susceptibility. These calculations used two cladding burst correlations and three fuel pulverization models so that the predictions of these models could be compared. The updated PWR simulations show markedly improved numerical stability as the number of crashed simulations decreased by 95% compared to the previous study, and hence higher confidence in results. The updated PWR simulations predicted cladding bursts exclusively among once-burned, high-power rods, with two different cladding burst models identifying the same burst-susceptible population. Resulting FFRD susceptibility estimates are significantly reduced compared with earlier studies, driven by cooler predicted fuel and plenum temperatures, lower hoop strains, and reduced fission gas release in the updated models. In contrast, none of the BWR rods were predicted to burst under either burst criterion, reaffirming minimal BWR FFRD susceptibility even with updated HBS and material models. Comparisons between the PWR and BWR end-of-cycle predictions are made. Comparison with prior work highlights significant shifts in PWR fuel performance metrics and confirmation of earlier BWR conclusions. Overall, the updated results underscore the importance of having high-resolution detailed modeling capability and continuously integrating evolving material models and physics into high-resolution multiphysics simulations. The unified assessment presented here strengthens confidence in predicting high-burnup LOCA behavior by improving agreement between different cladding burst correlations. These results also provide an improved foundation for future BISON model development, FFRD susceptibility calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Advanced CO 2 Capture Solvent Systems for Dynamic Power Generation: Quarterly Research Performance Progress Report, QR4 (Q4FY24)

We developed an integrated Computational Fluid Dynamics (CFD) model to simulate the multi-physics coupled cooling process of mixed gas by cold water within a Direct Contact Cooler (DCC) equipped with a rotating packing bed (RPB). The model captures the interactions between fluid dynamics, heat transfer, mass transport, and phase transitions, while accounting for key operational variables such as RPB rotational speed and the mass flow rates of both liquid and gas. The CFD model has been validated using experimental data, specifically by comparing predicted outflow gas and liquid temperatures to measured results. Our findings demonstrate the significant effects of RPB rotational speed and mass flow rates on cooling performance, providing valuable insights for optimizing DCC efficiency in industrial applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A cryogenic torsion balance using a liquid-cryogen free, ultra-low vibration cryostat

We describe a liquid-cryogen free cryostat with ultra-low vibration levels, which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. Here, the torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3–10 mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.

47 OTHER INSTRUMENTATION↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗