Search NASA⌕ Search

SEARCH · Search NASA

Results for “membrane degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mathematical Modeling of the Potential and Time Dependence of Ir Dissolution from Hydrous Ir Oxide Oxygen Evolution Catalysts

One of the main degradation mechanisms of hydrous iridium oxide acidic oxygen evolution reaction (OER) catalysts is dissolution and loss into the acidic membrane. While degradation models have been proposed, there is a gap in understanding the potential and time dependence of the iridium dissolution reaction and its mechanistic underpinnings. In this work, Ir dissolution rates measured as a function of time and potential via time-resolved inductively-coupled plasma mass spectrometry (ICP-MS) in aqueous acidic electrolyte are used to establish a mathematical model for Ir dissolution. The mathematical model is generated using proposed formation and dissolution reactions for Ir species. Through comparison with the ICP-MS data and existing information on the potential-dependent Ir phase, we find that the potential and time-dependence of dissolution can be modeled as dissolution of an oxide phase, here represented as IrO 2 , with potential dependent kinetics and formation of a passivating species, a process with a rate-limiting step that is not potential dependent. This understanding of the potential dependence of dissolution and passivation kinetics using aqueous electrolyte half-cell measurements can be used to predict the degradation of Ir oxide in operating energy conversion devices relying on the OER, such as proton-exchange membrane water electrolyzers.

Kariuki, Nancy N. [Argonne National Laboratory (AN↗

Links between autophagy and lipid droplet dynamics

Abstract Autophagy is a catabolic process in which cytoplasmic components are delivered to vacuoles or lysosomes for degradation and nutrient recycling. Autophagy-mediated degradation of membrane lipids provides a source of fatty acids for the synthesis of energy-rich, storage lipid esters such as triacylglycerol (TAG). In eukaryotes, storage lipids are packaged into dynamic subcellular organelles, lipid droplets. In times of energy scarcity, lipid droplets can be degraded via autophagy in a process termed lipophagy to release fatty acids for energy production via fatty acid β-oxidation. On the other hand, emerging evidence suggests that lipid droplets are required for the efficient execution of autophagic processes. Here, we review recent advances in our understanding of metabolic interactions between autophagy and TAG storage, and discuss mechanisms of lipophagy. Free fatty acids are cytotoxic due to their detergent-like properties and their incorporation into lipid intermediates that are toxic at high levels. Thus, we also discuss how cells manage lipotoxic stresses during autophagy-mediated mobilization of fatty acids from lipid droplets and organellar membranes for energy generation.

59 BASIC BIOLOGICAL SCIENCES↗

PdAu/YSZ composite hydrogen separation membranes with enhanced stability in the presence of CO

The effects of gold composition on the tolerance of palladium-based composite membranes to CO exposure was studied under the presence of high CO concentrations. Membranes with PdAu compositions ranging up to 41% by mass were exposed to binary 50/50 H 2 /CO gas atmospheres and both hydrogen flux and purity were monitored over time. It was observed that the highest gold composition (41%) suffered no degradation in membrane performance in terms of permeate hydrogen purity and hydrogen permeation flux during the 48 h exposure. Furthermore, for lower gold compositions, X-ray diffraction patterns suggested that carbon entered the film and could be removed by exposure to a non-CO containing gas mixture over time. However, removal of the carbon adversely affected purity; interestingly, some of the purity decline could be reversed upon re-exposure to the CO gas mixture. It is hypothesized that carbon loading in the palladium films causes lattice expansion and may even fill pore defects, thus lowering leaks through the Pd films. Furthermore, this study suggests that a membrane exposed to a CO mixture should not be cycled between CO and non-CO environments, but rather run continuously for best performance. Additionally, the choice of Pd-alloy and metal composition should be considered in regard to its carbon solubility to best predict lifetime performance.

08 HYDROGEN↗

Acceleration of Pd-V intermetallic diffusion by hydrogen

Vanadium-based membranes have great potential for hydrogen purification due to their perfect selectivity, high permeability, and relatively low cost. With appropriate surface cleaning, V efficiently permeates hydrogen at elevated temperature, but performance declines due to its affinity to absorb impurities. Here, the application of palladium thin films maintains a clean surface that catalyzes hydrogen dissociation and recombination. Hydrogen permeation in Pd-V-Pd membranes initially reach theoretical permeability, but declines due to Pd-V interdiffusion. The objective of this work was to quantify the intermetallic diffusion process as a function of temperature and ambient. Pd-V composites were subjected to various annealing treatments and characterized using Auger electron spectroscopy, X-ray diffraction, and energy dispersive X-ray spectroscopy, as well as correlated to measurements of membrane permeability. In an inert environment Pd-V interdiffusion was observable as low as 300 °C, and the diffusion coefficient had an activation energy of 44 kJ/mol. Furthermore, the presence of hydrogen at partial pressures > 10 kPa accelerated interdiffusion six-fold at T = 400 °C. Membrane performance degraded with an activation energy 75 kJ/mol, suggesting that intermetallic diffusion leads to both a loss of catalytic activity and as well as degradation of bulk permeability. These findings provide a baseline for evaluating hydrogen permeable interdiffusion barriers to overcome these challenges.

08 HYDROGEN↗

Understanding Recoverable vs Unrecoverable Voltage Losses and Long-Term Degradation Mechanisms in Anion Exchange Membrane Fuel Cells

Anion exchange membrane fuel cells (AEMFCs) have recently shown excellent progress in terms of their performance – e.g., achievable power and current density. However, very few AEMFCs have been demonstrated with the ability to operate for a long duration (>1000 h). In addition, it is unknown whether performance losses observed during operation are reversible, irreversible, or a combination of the two. In this study, a high-performance AEMFC operated continuously at 600 mA/cm 2 for 3600 h (150 days) at 80 °C with H 2 /O 2 reacting gases was demonstrated. Throughout testing, the electrochemical properties of the AEMFC were probed to provide information about performance degradation pathways and their degree of reversibility. It was found that a portion of the performance loss that occurs during AEMFC operation was due to suboptimal reaction conditions and can be recovered. At the end of the experiment, the cell was disassembled, and its structure and composition were evaluated at the nanoscale by aberration-corrected scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy. The structure and composition of the electrode were compared to cells at the beginning of their operational life. It was found that the primary mechanism for long-term AEMFC performance loss was catalyst agglomeration. During the operational time, there was no evidence of significant polymer degradation, likely due to the high hydration state of the cell. By documenting the long-term changes in high-performing AEMFCs, this work provides important information for the systematic design of cell components and demonstrates the importance of controlling cell operation, which can aid in the commercialization and widespread deployment of low-cost, long-life AEMFCs.

30 DIRECT ENERGY CONVERSION↗

Transforming an ATP-dependent enzyme into a dissipative, self-assembling system

Nucleoside triphosphate (NTP)-dependent protein assemblies such as microtubules and actin filaments have inspired the development of diverse chemically fueled molecular machines and active materials but their functional sophistication has yet to be matched by design. Given this challenge, we asked whether it is possible to transform a natural adenosine 5'-triphosphate (ATP)-dependent enzyme into a dissipative self-assembling system, thereby altering the structural and functional mode in which chemical energy is used. Furthermore we report that FtsH (filamentous temperature-sensitive protease H), a hexameric ATPase involved in membrane protein degradation, can be readily engineered to form one-dimensional helical nanotubes. FtsH nanotubes require constant energy input to maintain their integrity and degrade over time with the concomitant hydrolysis of ATP, analogous to natural NTP-dependent cytoskeletal assemblies. Yet, in contrast to natural dissipative systems, ATP hydrolysis is catalyzed by free FtsH protomers and FtsH nanotubes serve to conserve ATP, leading to transient assemblies whose lifetimes can be tuned from days to minutes through the inclusion of external ATPases in solution.

59 BASIC BIOLOGICAL SCIENCES↗

NiFeCo-based catalysts in high current zero-gap anion exchange membrane water electrolyzers

Understanding degradation mechanisms in pure water anion exchange membrane water electrolyzers is essential for developing durable and precious metal-free hydrogen production systems, yet electronic, chemical, and transport-driven pathways often occur simultaneously at the anode. To separate these effects, we establish a morphology invariant Ni/Fe/Co thin film model catalyst platform using physical vapor deposition and systematically compare composition-dependent behavior under both pure water and 0.1 M KOH feeds. Devices were operated under industrially relevant current density conditions, galvanostatically at 1 A cm −2 for 24 hours; metal dissolution, ionomer oxidation, and resistance growth were quantified using inductively coupled plasma mass spectrometry, X-ray photoelectron spectroscopy (XPS), and electrochemical impedance spectroscopy. Under pure-water operation, Ni-rich films showed voltage increases that correlated with rising total cell resistance (ΔV ≈ 243 mV, ΔR ≈ 0.17 Ω cm 2 ). Co-rich films maintained near constant voltages with minimal resistance change (ΔV < 10 mV, ΔR ≈ 0.03 Ω cm 2 ) but induced pronounced ionomer oxidation observed by XPS. In 0.1 M KOH, ionomer oxidation is suppressed, and impedance growth is minimized (<0.08 Ω cm 2 ) across all compositions, consistent with reduced transport limitations and improved ionic conduction relative to pure-water feeds. These results demonstrate how a controlled thin film model platform can isolate composition electrolyte relationships and provide mechanistic design principles for stable pure water anion exchange membrane electrolyzers.

Milenia Rojas Mendoza, B. [Stanford Univ., CA (Uni↗

High-Current Density Durability of Pt/C and PtCo/C Catalysts at Similar Particle Sizes in PEMFCs

The durability of carbon supported PtCo-alloy based nanoparticle catalysts play a key role in the longevity of proton-exchange membrane fuel cells (PEMFC) in electric vehicle applications. To improve its durability, it is important to understand and mitigate the various factors that cause PtCo-based cathode catalyst layers (CCL) to lose performance over time. These factors include i) electrochemical surface area (ECSA) loss, ii) specific activity loss, iii) H + /O 2 -transport changes and iv) Co 2+ contamination effects. We use a catalyst-specific accelerated stress test (AST) voltage cycling protocol to compare the durability of Pt and PtCo catalysts at similar average nanoparticle size and distribution. Our studies indicate that while Pt and PtCo nanoparticle catalysts suffer from similar magnitudes of electrochemical surface area (ECSA) losses, PtCo catalyst shows a significantly larger cell voltage loss at high current densities upon durability testing. The distinctive factor causing the large cell voltage loss of PtCo catalyst appears to be the secondary effects of the leached Co 2+ cations that contaminate the electrode ionomer. A 1D performance model has been used to quantify the cell voltage losses arising from various factors causing degradation of the membrane electrode assembly (MEA).

08 HYDROGEN↗

Steady-State Vacuum Ultraviolet Exposure Facility With Automated Lamp Calibration and Sample Positioning Fabricated

The Next Generation Space Telescope (NGST) will be placed in an orbit that will subject it to constant solar radiation during its planned 10-year mission. A sunshield will be necessary to passively cool the telescope, protecting it from the Sun s energy and assuring proper operating temperatures for the telescope s instruments. This sunshield will be composed of metalized polymer multilayer insulation with an outer polymer membrane (12 to 25 mm in thickness) that will be metalized on the back to assure maximum reflectance of sunlight. The sunshield must maintain mechanical integrity and optical properties for the full 10 years. This durability requirement is most challenging for the outermost, constantly solar-facing polymer membrane of the sunshield. One of the potential threats to the membrane material s durability is from vacuum ultraviolet (VUV) radiation in wavelengths below 200 nm. Such radiation can be absorbed in the bulk of these thin polymer membrane materials and degrade the polymer s optical and mechanical properties. So that a suitable membrane material can be selected that demonstrates durability to solar VUV radiation, ground-based testing of candidate materials must be conducted to simulate the total 10- year VUV exposure expected during the Next Generation Space Telescope mission. The Steady State Vacuum Ultraviolet exposure facility was designed and fabricated at the NASA Glenn Research Center at Lewis Field to provide unattended 24-hr exposure of candidate materials to VUV radiation of 3 to 5 times the Sun s intensity in the wavelength range of 115 to 200 nm. The facility s chamber, which maintains a pressure of approximately 5 10(exp -6) torr, is divided into three individual exposure cells, each with a separate VUV source and sample-positioning mechanism. The three test cells are separated by a water-cooled copper shield plate assembly to minimize thermal effects from adjacent test cells. Part of the interior sample positioning mechanism of one test cell is shown in the illustration. Of primary concern in VUV exposure is the maintenance of constant measured radiation intensity so that the sample s total exposure can be determined in equivalent Sun hours. This is complicated by the fact that a VUV lamp s intensity degrades over time, necessitating a decrease in the distance between the test samples and the lamp. The facility overcomes this challenge by periodically measuring the lamp s intensity with a cesium-iodide phototube and adjusting the sample distance as required to maintain constant exposure intensity. Sample positioning and periodic phototube location under the lamp are both achieved by a single lead-screw assembly. The lamps can be isolated from the main vacuum chamber for cleaning or replacement so that samples are not exposed to the atmosphere during a test.

Sechkar, Edward A.↗

Spatially resolved performance and degradation in a perfluorinated anion exchange membrane fuel cell

Anion exchange membrane fuel cells may enable future operation with non-precious metal-based catalysts. These systems have a delicate sensitivity to operating conditions such as humidification levels and the presence of CO2 in the air oxidant stream. We present spatially resolved in-situ performance results that shed light on phenomena that are unique to anion exchange membrane fuel cells. For cell construction, a highly conductive perfluorinated anion exchange polymer was used as the membrane and the material in powder form as the ionomer. Experiments were conducted to investigate the effects of humidification, fuel/oxidant concentration, and carbonation effects on the performance and its distribution in the cell. The results indicated that (i) dry conditions at the cathode have a stronger effect than at the anode on overall cell performance, (ii) performance significantly suffered when humidification was below 90%, (iii) fuel and oxidant dilution effects lead mass-transport losses and were stronger than flow rate effects, (iv) CO2 in the cathode feed stream creates an equilibration disparity between the inlet and outlet sections and CO2 purging is affected by flooding conditions, and (v) after >500 h of operation, performance deteriorates predominantly at the inlet.

2+1D fuel cell model↗

Degradation Effects at the Porous Transport Layer/Catalyst Layer Interface in Polymer Electrolyte Membrane Water Electrolyzer

The porous transport layer (PTL)/catalyst layer (CL) interface plays a crucial role in the achievement of high performance and efficiency in polymer electrolyte membrane water electrolyzers (PEMWEs). This study investigated the effects of the PTL/CL interface on the degradation of membrane electrode assemblies (MEAs) during a 4000 h test, comparing the MEAs assembled with uncoated and Ir-coated Ti PTLs. Our results show that compared to an uncoated PTL/CL interface, an optimized interface formed when using a platinum group metal (PGM) coating, i.e., an iridium layer at the PTL/CL interface, and reduced the degradation of the MEA. The agglomeration and formation of voids and cracks could be found for both MEAs after the long-term test, but the incorporation of an Ir coating on the PTL did not affect the morphology change or oxidation of IrO x in the catalyst layer. In addition, our studies suggest that the ionomer loss and restructuring of the anodic MEA can also be reduced by Ir coating of the PTL/CL interface. Optimization of the PTL/CL interface improves the performance and durability of a PEMWE.

30 DIRECT ENERGY CONVERSION↗

Evidence for a membrane defect in Alzheimer disease brain

To determine whether neurodegeneration in Alzheimer disease brain is associated with degradation of structural cell membrane molecules, we measured tissue levels of the major membrane phospholipids and their metabolites in three cortical areas from postmortem brains of Alzheimer disease patients and matched controls. Among phospholipids, there was a significant (P less than 0.05) decrease in phosphatidylcholine and phosphatidylethanolamine. There were significant (P less than 0.05) decreases in the initial phospholipid precursors choline and ethanolamine and increases in the phospholipid deacylation product glycerophosphocholine. The ratios of glycerophosphocholine to choline and glycerophosphoethanolamine to ethanolamine were significantly increased in all examined Alzheimer disease brain regions. The activity of the glycerophosphocholine-degrading enzyme glycerophosphocholine choline-phosphodiesterase was normal in Alzheimer disease brain. There was a near stoichiometric relationship between the decrease in phospholipids and the increase of phospholipid catabolites. These data are consistent with increased membrane phospholipid degradation in Alzheimer disease brain. Similar phospholipid abnormalities were not detected in brains of patients with Huntington disease, Parkinson disease, or Down syndrome. We conclude that the phospholipid abnormalities described here are not an epiphenomenon of neurodegeneration and that they may be specific for the pathomechanism of Alzheimer disease.

NASA Discipline Regulatory Physiology↗

Mitigating cerium migration for perfluorosulfonic acid membranes using organic ligands

Improving the electrochemical stability of proton exchange membranes is a pressing priority for heavy-duty fuel cell vehicles. The lifetime of the most widely used perfluorosulfonic acid membranes is limited by reactive free radicals generated inside the system. Cerium has been found to reduce the chemical degradation of the membranes. However, cerium migration during fuel cell operation limits the chemical durability enhancement effect expected from the radical scavenging activity of cerium. Here we investigate a wide range of organic immobilizers for cerium, measuring their suitability concerning cerium retention, radical scavenging activity, and fuel cell performance. Further, we report that partially fluorinated phosphonic acids enhance cerium retention up to 45 times and reduce fluoride emission rate by 38% compared to the commercial Nafion™ XL membrane pre-impregnated with cerium. The energetics of cerium-phosphonic acid complex systems by density functional theory calculations rationalizes effective cerium immobilization.

25 ENERGY STORAGE↗

Mitigating cerium migration for perfluorosulfonic acid membranes using organic ligands

Improving the electrochemical stability of proton exchange membranes is a pressing priority for heavy-duty fuel cell vehicles. The lifetime of the most widely used perfluorosulfonic acid membranes is limited by reactive free radicals generated inside the system. Cerium has been found to reduce the chemical degradation of the membranes. However, cerium migration during fuel cell operation limits the chemical durability enhancement effect expected from the radical scavenging activity of cerium. Here we investigate a wide range of organic immobilizers for cerium, measuring their suitability concerning cerium retention, radical scavenging activity, and fuel cell performance. We report that partially fluorinated phosphonic acids enhance cerium retention up to 45 times and reduce fluoride emission rate by 38% compared to the commercial Nafion™ XL membrane pre-impregnated with cerium. The energetics of cerium-phosphonic acid complex systems by density functional theory calculations rationalizes effective cerium immobilization.

30 DIRECT ENERGY CONVERSION↗