Surface extraction from micro-computed tomography data for additive manufacturing
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract not provided.
Abstract not provided
Abstract not provided
Abstract not provided
This document details the microCT data collection systems in use at the Transportation Security Laboratory, Lawrence Livermore National Laboratory, and Tyndall Air Force Base for homemade explosive characterization. X-ray source, detector, and motional control hardware are specified as well as specimen platforms, containers, and reference material types. Most of the details on the LLNL and Tyndall systems are derived from References 2 and 3. The steps that constitute the raw data processing and CT reconstruction are also recorded. Sources for further information on the processing, and technical subsystems, are given in the Section 3 References.
HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) is a powerful high explosive that is routinely used in formulations such as PBX 9501. Much remains to be learned about the performance and mechanical properties of HMX formulations such as these, particularly after dynamic damage has occurred. We have prepared formulations with HMX using hydroxyl terminated polybutadiene (HTPB) binder in order to form an explosive that is relatively insensitive to mild stimuli, analogous to PBXB-110 (different only is substitution of dioctyladipate (DO) for isodecyl pelargonate).
No abstract available
Abstract not provided
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Micro X-ray computed tomography (XCT) was used to analyze the 3D adhesive penetration behavior of different wood–adhesive bondlines. Three adhesives, a phenol formaldehyde (PF), a polymeric diphenylmethane diisocyanate (pMDI), and a hybrid polyvinyl acetate (PVA), all tagged with iodine for enhanced X-ray attenuation, were used to prepare single-bondline laminates in two softwoods, Douglas-fir and loblolly pine, and one hardwood, a hybrid polar. Adhesive penetration depth was measured with two separate calculations, and results were compared with 2D fluorescent micrographs. A total of 54 XCT scans were collected, representing six replicates of each treatment type; each replicate, however, consisted of approximately 1500 individual, cross-section slices stacked along the specimen length. As these adhesives were highly modified, the presented results do not indicate typical behavior for their broader adhesive classes. Still, clear penetration differences were observed between each adhesive type, and between wood species bonded with both the PF and pMDI adhesives. Furthermore, penetration results depended on the calculation method used. Two adhesive types with noticeably different resin distributions in the cured bondline, showed relatively similar penetration depths when calculated with a traditional effective penetration equation. However, when the same data was calculated with a weighted penetration calculation, which accounts for both adhesive area and depth, the results appeared to better represent the different distributions depicted in the photomicrographs and tomograms. Additionally, individual replicate comparisons showed variation due to specimen anatomy, not easily observed or interpreted from 2D images. Finally, 3D views of segmented 3D adhesive phases offered unique, in-situ views of the cured adhesive structures. In particular, voids formed by CO 2 bubbles generated during pMDI cure were clearly visible in penetrated columns of the solidified adhesive.
Closed-cell foams in compression exhibit complex deformation characteristics that remain incompletely understood. In this paper the microstructural evolution of closed-cell polymethacrylimide foam was simulated in compression undergoing elastic, compaction, and densification stages. The three-dimensional microstructure of the foam is determined using Micro-Computed Tomography ({micro}-CT), and is converted to material points for simulations using the material point method (MPM). The properties of the cell-walls are determined from nanoindentation on the wall of the foam. MPM simulations captured the three stages of deformations in foam compression. Features of the microstructures from simulations are compared qualitatively with the in-situ observations of the foam under compression using {micro}-CT. The stress-strain curve simulated from MPM compares reasonably with the experimental results. Based on the results from {micro}-CT and MPM simulations, it was found that elastic buckling of cell-walls occurs even in the elastic regime of compression. Within the elastic region, less than 35% of the cell-wall material carries the majority of the compressive load. In the experiment, a shear band was observed as a result of collapse of cells in a weak zone. From this collapsed weak zone a compaction (collapse) wave was seen traveling which eventually lead to the collapse of the entire foam cell-structure. Overall, this methodology will allow prediction of material properties for microstructures driving the optimization of processing and performance in foam materials.
Purpose: In our previous study a preclinical multi-modality quality assurance (QA) phantom that contains five tumor-simulating test objects with 2, 4, 7, 10 and 14 mm diameters was developed for accurate tumor size measurement by researchers during cancer drug development and testing. This study analyzed the errors during tumor volume measurement from preclinical magnetic resonance (MR), micro-computed tomography (micro- CT) and ultrasound (US) images acquired in a rodent tumor model using the preclinical multi-modality QA phantom. Methods: Using preclinical 7-Tesla MR, US and micro-CT scanners, images were acquired of subcutaneous SCC4 tumor xenografts in nude rats (3–4 rats per group; 5 groups) along with the QA phantom using the same imaging protocols. After tumors were excised, in-air micro-CT imaging was performed to determine reference tumor volume. Volumes measured for the rat tumors and phantom test objects were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three imaging modalities. Then linear regression analysis was performed to compare image-based tumor volumes with the reference tumor volume and known test object volume for the rats and the phantom respectively. Results: The slopes of regression lines for in-vivo tumor volumes measured by three imaging modalities were 1.021, 1.101 and 0.862 for MRI, micro-CT and US respectively. For phantom, the slopes were 0.9485, 0.9971 and 0.9734 for MRI, micro-CT and US respectively. Conclusion: For both animal and phantom studies, random and systematic errors were observed. Random errors were observer-dependent and systematic errors were mainly due to selected imaging protocols and/or measurement method. In the animal study, there were additional systematic errors attributed to ellipsoidal assumption for tumor shape. The systematic errors measured using the QA phantom need to be taken into account to reduce measurement errors during the animal study.