Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro ion traps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

51 records · Page 3

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of ion-scale micro-turbulence in pedestal width of the DIII-D wide-pedestal QH mode

The low-edge rotation, intrinsically ELM-free, and improved confinement wide-pedestal quiescent H-mode (QH-mode), discovered in DIII-D tokamak, has pedestal widths exceeding the EPED-kinetic-ballooning mode (KBM) model scaling typically by at least 25%. Ion-scale ($k_yp_s$ < 1) microturbulence and its role in setting the pedestal structure is investigated using the radially local δ$f$ gyrokinetic code CGYRO. The electromagnetic trapped electron mode (TEM) is unstable at the pedestal top, while plasma beta (β$_e$) is ∼60% below the KBM onset threshold and the electron temperature gradient mode is found to be unstable in the peak gradient region. Nonlinear simulation reveals that the ion-scale turbulence could produce electron energy flux consistent with the flux inferred from power balance at the pedestal top, with a reasonable variation of the local shearing rate; and the local neoclassical transport from NEO is dominant over the simulated turbulent transport in the ion energy flux channel. The simulated ion-scale turbulence produces much lower electron energy flux than inferred from experiment in the pedestal peak gradient region. A correction to the EPED-KBM pedestal width scaling is obtained based on the two-dimensional scan of pedestal top plasma beta (β$_e$) and normalized electron density and temperature scale lengths,${a}$/${L_n}_e$, ${a}$/${L_T}_n$using CGYRO linear simulations. Mode transitions among TEM, micro-tearing mode, ion-temperature gradient mode and KBM, are observed in the 2D scan at the pedestal top. A fixed normalized growth rate for these drift-type modes is taken to determine the pedestal width scaling, which shows good consistency with the QH experimental database on pedestal heights and widths. The onset of KBM instabilities and the local E × B shear suppression criterion set the lower and upper limit for the pedestal width of standard QH-mode, wide-pedestal QH-mode and type-I ELMy H mode. A potentially higher and wider pedestal is expected from the new scaling of pedestal width. This work presents an improved understanding of the ion-scale micro-turbulence of wide-pedestal QH-mode and sheds light on a promising scenario for future reactors, including ITER and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

quadrupole ion trap↗

Ion Chromatography-on-a-chip for Water Quality Analysis

We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

Kidd, R. D.↗

New millimeter-wave diagnostics to locally probe internal density and magnetic field fluctuations in National Spherical Torus Experiment-Upgrade (invited)

A set of new millimeter-wave diagnostics will deliver unique measurement capabilities for National Spherical Torus Experiment-Upgrade to address a variety of plasma instabilities believed to be important in determining thermal and particle transport, such as micro-tearing, global Alfvén eigenmodes, kinetic ballooning, trapped electron, and electron temperature gradient modes. These diagnostics include a new integrated intermediate-k Doppler backscattering (DBS) and cross-polarization scattering (CPS) system (four channels, 82.5–87 GHz) to measure density and magnetic fluctuations, respectively. The system can access reasonably large normalized wavenumbers k θ ρ s ranging from ≤0.5 to 15 (where ion sound gyroradius ρ s = 1 cm and k θ is the binormal density turbulence wavenumber). The system addresses the challenges for making useful DBS/CPS measurements with a remote control of launch polarization (X- or O-mode), probed wavenumber, polarization match of the launch beam with the edge magnetic field pitch angle, and beam steering of the launched beam for wave-vector alignment. In addition, a low-k DBS system consisting of eight fixed frequencies (34–52 GHz) and four tunable frequencies (55–75 GHz) for low-k density turbulence and fast ion physics will be located at a nearby port location. Finally, the combined systems cover the near LCFS and pedestal regions (34–52 GHz), the pedestal or mid-radius (50–75 GHz), and core plasmas (82.5–87 GHz).

47 OTHER INSTRUMENTATION↗

Insight on electrolyte infiltration of lithium ion battery electrodes by means of a new three-dimensional-resolved lattice Boltzmann model

Electrolyte filling takes place between sealing and formation in Lithium Ion Battery (LIB) manufacturing process. This step is crucial as it is directly linked to LIB quality and affects the subsequent time consuming electrolyte wetting process. Although having fast, homogeneous and complete wetting is of paramount importance, this process has not been sufficiently examined and fully understood. For instance, experimentally available data is insufficient to fully capture the complex interplay upon filling between electrolyte and air inside the porous electrode. We report here for the first time a 3D-resolved Lattice Boltzmann Method (LBM) model able to simulate electrolyte filling upon applied pressure of LIB porous electrodes obtained both from experiments (micro X-ray tomography) and computations (stochastic generation, simulation of the manufacturing process using Coarse Grained Molecular Dynamics and Discrete Element Method). The model allows obtaining advanced insights about the impact of the electrode mesostructures on the speed of electrolyte impregnation and wetting, highlighting the importance of porosity, pore size distribution and pores interconnectivity on the filling dynamics. Furthermore, we identify scenarios where volumes with trapped air (dead zones) appear and evaluate the impact of those on the electrochemical behavior of the electrodes.

25 ENERGY STORAGE↗

Migration and Precipitation of Platinum in Anion‐Exchange Membrane Fuel Cells

Abstract Despite the recent progress in increasing the power generation of Anion‐exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X‐ray micro‐computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X‐ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt +2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo−N−C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

Raut, Aniket↗

Migration and Precipitation of Platinum in Anion–Exchange Membrane Fuel Cells

Despite the recent progress in increasing the power generation of Anion-exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X-ray micro-computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt+2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Furthermore, diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo–N–C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A future, intense source of negative hydrogen ions

By directly heating lithium hydride in a vacuum, up to 18 micro-A/sq cm of negative hydrogen has been obtained from the crystal lattice. The amount of ion current extracted and analyzed is closely related to the temperature of the sample and to the rate at which the temperature is changed. The ion current appears to be emission limited and saturates with extraction voltage. For a fixed extraction voltage, the ion current could be maximized by placing a grid between the sample surface and the extraction electrode. Electrons accompanying the negative ions were removed by a magnetic trap. A Wein velocity filter was designed and built to provide definitive mass analysis of the extracted ion species. This technique when applied to other alkali hydrides may produce even higher intensity beams possessing low values of emittance.

Siefken, Hugh↗

Ultra-narrow-linewidth hybrid-integrated self-injection locked laser at 780 nm

Narrow-linewidth lasers are essential across a wide range of applications, including classical and quantum sensing, trapped ion systems, position/navigation/timing systems, optical clocks, and microwave frequency synthesizers. In the visible and near-visible spectrum, low-noise lasers are particularly important for laser trapping and cooling techniques, which are vital for trapped ion quantum computing, sensing, and atomic clocks. In this context, our work showcases a hybrid-integrated narrow-linewidth laser that operates at 780 nm, achieving a self-heterodyne linewidth of 105 Hz. To validate the experimental results, we performed a numerical analysis that combines insights from a many-body theory applied to the gain region with a travelling-wave model to capture the laser dynamics. Our investigation further delves into how the linewidth of the self-injection locked lasers is influenced by the parameters of micro-ring resonators, aiming to assess the potential for achieving Hz-level integrated laser linewidths at 780 nm. This work not only demonstrates the technical feasibility of Hz-level narrow-linewidth lasers but also lays the groundwork for future explorations in the field.

Prokoshin, Artem (ORCID:0009000699760238)↗

Intense laser interaction with micro-bars

Intense laser fields interact very differently with micrometric rough surfaces than with flat objects. The interaction features high laser energy absorption and increased emission of MeV electrons, ions, and of hard x-rays. In this work, we irradiated isolated, translationally-symmetric objects in the form of micrometric Au bars. The interaction resulted in the emission of two forward-directed electron jets having a small opening angle, a narrow energy spread in the MeV range, and a positive angle to energy correlation. Our numerical simulations show that following ionization, those electrons that are pulled into vacuum near the object’s edge, remain in-phase with the laser pulse for long enough so that the Lorentz force they experience drive them around the object’s edge. After these electrons pass the object, they form attosecond duration bunches and interact with the laser field over large distances in vacuum in confined volumes that trap and accelerate them within a narrow range of momentum. The selectivity in energy of the interaction, its directionality, and the preservation of the attosecond duration of the electron bunches over large distances, offer new means for designing future laser-based light sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

When we last reported, our new microcalorimeter system was being prepared for delivery and permanent installation at the NIST EBIT. This occurred in June 2003 and check-out with the internal calibration source and EBIT plasma x-rays took place over the next several months during which time we modified several component parts to improve the performance. These changes included: 1) A redesign of the x-ray calibration source from a direct electron impact source to one that irradiates the microcalorimeter with fluorescent x-rays. The resulting calibration lines are free of bremsstrahlung background; 2) The microcalorimeter electronic circuit has been significantly improved to ensure long-term stability for the lengthy upcoming runs of the EBIT. Both the preamplifier feedback resistors were changed and the first stage of the preamplifier redesigned. Several photos of the new system are shown in slides 3 and 4. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours in our earlier system) and it will hold a temperature of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. The first x-ray spectra of the new calibration source made with the 4-element detector array is shown. An example of the temperature control capabilities of the ADR for a 23 hour interval is shown. The horizontal line shows the temperature stability (about +/- 3 micro kelvin). There are a few short-lived heating excursions caused by technical staff working on the EBIT machine simultaneously. During actual experimental runs these are absent. This temporal profile was interrupted to test additional components of the system; otherwise, the temperature controlling would have continued for another 24 hours.

Silver, Eric↗

Anomalous lattice expansion of bcc Ta in helium-loaded diamond anvil cells

Anomalous lattice expansion of bcc Ta is observed in helium-loaded diamond anvil cell (DAC) experiments near 6 GPa and above 400 K, while co-loaded W, Mo, and Au exhibit normal thermal expansion. The Ta volume expansion increases with temperature, reaching ~14% near 650 K before plateauing, and is largely retained after recovery to ambient conditions. Time-resolved measurements at 500 K reveal progressive expansion over several hours, consistent with gradual, thermally activated He incorporation. The largely retained expansion during subsequent cooling and holding at 400 K indicates that the incorporated He is predominantly kinetically trapped. The data reveal two distinct regimes: below ~550 K, modest and spatially uniform expansion consistent with interstitial He trapping at isolated, randomly distributed vacancies; above ~550 K, He-vacancy cluster growth producing dramatically larger expansion, peak broadening, and a core–shell microstructure revealed by micron-resolution X-ray diffraction mapping. These results demonstrate that He is not always a passive pressure medium in DAC experiments and reveal a previously unrecognized regime of He-mediated lattice modification in Ta, complementing conventional ion-implantation studies relevant to nuclear and fusion structural materials.

Diamond anvil cell↗

Chemistry and Dynamics of Supercritical Carbon Dioxide and Methane in the Slit Pores of Layered Silicates

In the mid 2010s, high-pressure diffraction and spectroscopic tools opened a window into the molecular-scale behavior of fluids at the conditions of many CO 2 sequestration and shale/tight gas reservoirs - conditions where CO 2 and CH 4 are present as variably wet supercritical fluids. Integrating high-pressure spectroscopy and diffraction with molecular modeling has revealed much about the ways that supercritical CO 2 and CH 4 behave in reservoir components, particularly in the slit-shaped micro- and meso-pores of layered silicates (phyllosilicates) abundant in caprocks and shales. This Account summarizes how supercritical CO 2 and CH 4 behave in the slit pores of swelling phyllosilicates as functions of the H 2 O activity, framework structural features, and charge-balancing cation properties at 90 bar and 323 K – conditions similar to a reservoir at ~1 km depth. Slit pores containing cations with large radii, low hydration energy, and large polarizability readily interact with CO 2 , allowing CO 2 and H 2 O to adsorb and co-exist in these interlayer pores over a wide range of fluid humidities. In contrast, cations with small radii, high hydration energy, and low polarizability weakly interact with CO 2 leading to reduced CO 2 uptake and a tendency to exclude CO 2 from interlayers when H 2 O is abundant. The reorientation dynamics of confined CO 2 depends on the interlayer pore height, which is strongly influenced by the cation properties, framework properties, and fluid humidity. The silicate structural framework also influences CO 2 uptake and behavior - for example, smectites with increasing F-for-OH substitution in the framework take up greater quantities of CO 2 . Reactions that trap CO 2 in carbonate phases have been observed in thin H 2 O films near smectite surfaces, including a dissolution-reprecipitation mechanism when the edge surface area is high and an ion exchange-precipitation mechanism when the interlayer cation can form a highly insoluble carbonate. In contrast, supercritical CH 4 does not readily associate with cations, does not react with smectites, and is only incorporated into interlayer slit mesopores when (i) the pore has a $z$-dimension large enough to accommodate CH 4 , (ii) the smectite has low charge and (iii) the H 2 O activity is low. In conclusion, the adsorption and displacement of CH 4 by CO 2 and vice-versa have been studied on the molecular scale in one shale, but opportunities remain to examine behavioral details in this more complicated, slit-pore inclusive system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Slopes To Prevent Trapping of Bubbles in Microfluidic Channels

The idea of designing a microfluidic channel to slope upward along the direction of flow of the liquid in the channel has been conceived to help prevent trapping of gas bubbles in the channel. In the original application that gave rise to this idea, the microfluidic channels are parts of micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. It is necessary to prevent trapping of gas bubbles in these devices because uninterrupted liquid pathways are essential for sustaining the electrical conduction and flows that are essential for CE. The idea is also applicable to microfluidic devices that may be developed for similar terrestrial microCE biotechnological applications or other terrestrial applications in which trapping of bubbles in microfluidic channels cannot be tolerated. A typical microCE device in the original application includes, among other things, multiple layers of borosilicate float glass wafers. Microfluidic channels are formed in the wafers, typically by use of wet chemical etching. The figure presents a simplified cross section of part of such a device in which the CE channel is formed in the lowermost wafer (denoted the channel wafer) and, according to the present innovation, slopes upward into a via hole in another wafer (denoted the manifold wafer) lying immediately above the channel wafer. Another feature of the present innovation is that the via hole in the manifold wafer is made to taper to a wider opening at the top to further reduce the tendency to trap bubbles. At the time of reporting the information for this article, an effort to identify an optimum technique for forming the slope and the taper was in progress. Of the techniques considered thus far, the one considered to be most promising is precision milling by use of femtosecond laser pulses. Other similar techniques that may work equally well are precision milling using a focused ion beam, or a small diamond-tipped drill bit.

Greer, Harold E.↗