Search NASA⌕ Search

SEARCH · Search NASA

Results for “microelectromechanical systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Distributed Attitude Control and Maneuvering for Deep Space SmallSats

The aim of the Distributed Attitude Control and Maneuvering for Deep Space SmallSats project is to advance a multi-purpose, deep space mission-enabling technology for low-power attitude and thermal control of small satellites to a flight demonstration technology readiness level (TRL). The film-evaporation microelectromechanical systems tunable array (FEMTA) small satellite technology combines innovative microelectromechanical systems (MEMS) microfabrication and microscale effects in fluid surface tension to produce a thermally actuated capillary valve. Using water as the propellant, the FEMTA thruster can generate finely controllable thrust at a thrust to power ratio of about 200 microNewton per Watt (W).

thermal control↗

Light-Driven Polymeric Bimorph Actuators

Light-driven polymeric bimorph actuators are being developed as alternatives to prior electrically and optically driven actuators in advanced, highly miniaturized devices and systems exemplified by microelectromechanical systems (MEMS), micro-electro-optical-mechanical systems (MEOMS), and sensor and actuator arrays in smart structures. These light-driven polymeric bimorph actuators are intended to satisfy a need for actuators that (1) in comparison with the prior actuators, are simpler and less power-hungry; (2) can be driven by low-power visible or mid-infrared light delivered through conventional optic fibers; and (3) are suitable for integration with optical sensors and multiple actuators of the same or different type. The immediate predecessors of the present light-driven polymeric bimorph actuators are bimorph actuators that exploit a photorestrictive effect in lead lanthanum zirconate titanate (PLZT) ceramics. The disadvantages of the PLZT-based actuators are that (1) it is difficult to shape the PLZT ceramics, which are hard and brittle; (2) for actuation, it is necessary to use ultraviolet light (wavelengths < 380 nm), which must be generated by use of high-power, high-pressure arc lamps or lasers; (3) it is difficult to deliver sufficient ultraviolet light through conventional optical fibers because of significant losses in the fibers; (4) the response times of the PLZT actuators are of the order of several seconds unacceptably long for typical applications; and (5) the maximum mechanical displacements of the PLZT-based actuators are limited to those characterized by low strains beyond which PLZT ceramics disintegrate because of their brittleness. The basic element of a light-driven bimorph actuator of the present developmental type is a cantilever beam comprising two layers, at least one of which is a polymer that exhibits a photomechanical effect (see figure). The dominant mechanism of the photomechanical effect is a photothermal one: absorption of light energy causes heating, which, in turn, causes thermal expansion.

Adamovsky, Gregory↗

Piezoelectrically Actuated Microvalve for Liquid Effluents

Modifications have been proposed to effect further improvement of the device described in Improved Piezoelectrically Actuated Microvalve (NPO-30158), NASA Tech Briefs, Vol. 26, No. 1 (January 2002), page 29. To recapitulate: What is being developed is a prototype of valves for microfluidic systems and other microelectromechanical systems (MEMS). The version of the valve reported in the cited previous article included a base (which contained a seat, an inlet, and an outlet), a diaphragm, and a linear actuator. With the exception of the actuator, the parts were micromachined from silicon. The linear actuator consisted of a stack of piezoelectric disks in a rigid housing. To make the diaphragm apply a large sealing force on the inlet and outlet, the piezoelectric stack was compressed into a slightly contracted condition during assembly of the valve. Application of a voltage across the stack caused the stack to contract into an even more compressed condition, lifting the diaphragm away from the seat, thereby creating a narrow channel between the inlet and outlet. The positions of the inlet and outlet, relative to the diaphragm and seat, were such that the inlet flow and pressure contributed to sealing and thus to a desired normally-closed mode of operation.

Yang, Eui-Hyeok↗

Pressure-Sensor Assembly Technique

Nielsen Engineering & Research (NEAR) recently developed an ultrathin data acquisition system for use in turbomachinery testing at NASA Glenn Research Center. This system integrates a microelectromechanical- systems- (MEMS-) based absolute pressure sensor [0 to 50 psia (0 to 345 kPa)], temperature sensor, signal-conditioning application-specific integrated circuit (ASIC), microprocessor, and digital memory into a package which is roughly 2.8 in. (7.1 cm) long by 0.75 in. (1.9 cm) wide. Each of these components is flip-chip attached to a thin, flexible circuit board and subsequently ground and polished to achieve a total system thickness of 0.006 in. (0.15 mm). Because this instrument is so thin, it can be quickly adhered to any surface of interest where data can be collected without disrupting the flow being investigated. One issue in the development of the ultrathin data acquisition system was how to attach the MEMS pressure sensor to the circuit board in a manner which allowed the sensor s diaphragm to communicate with the ambient fluid while providing enough support for the chip to survive the grinding and polishing operations. The technique, developed by NEAR and Jabil Technology Services Group (San Jose, CA), is described below. In the approach developed, the sensor is attached to the specially designed circuit board, see Figure 1, using a modified flip-chip technique. The circular diaphragm on the left side of the sensor is used to actively measure the ambient pressure, while the diaphragm on the right is used to compensate for changes in output due to temperature variations. The circuit board is fabricated with an access hole through it so that when the completed system is installed onto a wind tunnel model (chip side down), the active diaphragm is exposed to the environment. After the sensor is flip-chip attached to the circuit board, the die is underfilled to support the chip during the subsequent grinding and polishing operations. To prevent this underfill material from getting onto the sensor s diaphragms, the circuit board is fabricated with two 25- micrometer-tall polymer rings, sized so that the diaphragms fit inside the rings once the chip is attached.

Pruzan, Daniel A.↗

On-Orbit, Immuno-Based, Label-Free White Blood Cell Counting System with Microelectromechanical Sensor Technology (OILWBCS-MEMS)

Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.

Edmonds, Jessica↗

Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

Hunter, Gary W.↗

Vacuum Packaging of MEMS With Multiple Internal Seal Rings

A proposed method of design and fabrication of vacuum-packaged microelectromechanical systems (MEMS) and of individual microelectromechanical devices involves the use of multiple internal seal rings (MISRs) in conjunction with vias (through holes plated with metal for electrical contacts). The proposed method is compatible with mass production in a wafer-level fabrication process, in which the dozens of MEMS or individual microelectromechanical devices on a typical wafer are simultaneously vacuum packaged by bonding a capping wafer before the devices are singulated (cut apart by use of a dicing saw). In addition to being compatible with mass production, the proposed method would eliminate the need for some complex and expensive production steps and would yield more reliable vacuum seals. Conventionally, each MEMS or individual microelectromechanical device is fabricated as one of many identical units on a device wafer. Vacuum packaging is accomplished by bonding the device wafer to a capping wafer with metal seal rings (one ring surrounding each unit) that have been formed on the capping wafer. The electrical leads of each unit are laid out on what would otherwise be a flat surface of the device wafer, against which the seal ring is to be pressed for sealing. The resulting pattern of metal lines and their insulating oxide coverings presents a very rough and uneven surface, upon which it is difficult to pattern the sealing metal. Consequently, the seal is prone to leakage unless additional costly and complex planarization steps are performed before patterning the seal ring and bonding the wafers.

Hayworth, Ken↗

DARPA beyond CMOS RFI

The Lawrence Livermore National Laboratory Center for Micro and Nanotechnology (CMNT) is located on the LLNL campus in Livermore, CA. LLNL employs over 7000 employees with a broad range of science and engineering backgrounds with an administrative structure that encourages multidisciplinary teaming, a key ingredient in our ability to address diverse technical problems. Our CMNT facility houses a 6,400 ft 2 class 100 cleanroom (class 10 capable) with an additional 1,000 ft 2 Class 1000 space, and 6000 ft 2 of other laboratories. Most equipment can accommodate 6” wafers, although some is limited to 4”. The CMNT is a multi-user, multi-programmatic facility that offers a broad set of instruments for microfabrication to invent, develop, and apply microscale and nanoscale technologies to support national security missions in Stockpile Stewardship, Homeland Security, Directed Energy, Nonproliferation, biomedical research, and more. The research and capabilities of the Center cover materials, devices, instruments, and systems that require microfabricated components, including microelectromechanical systems (MEMS), electronics, photonics, micro- and nanostructures, bio-implantable devices, and micro- and nanoactuators.

42 ENGINEERING↗

Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System

Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.

Wiberg, D. V.↗

Position sensing circuit for an electrostatically driven MEMS device

The present disclosure relates to a system for detecting movement of a microelectromechanical system (MEMS) device. The system uses a drive voltage signal source for generating a low frequency drive voltage signal for driving the MEMS device. An excitation signal source may be used for generating an excitation signal which is also applied to the MEMS device. The excitation signal has a frequency which is above a physical response capability of the MEMS device, such that operation of the MEMS device is not significantly affected by the excitation signal. A sensing impedance is used to help generate a signal which is responsive to the capacitance of the MEMS device. The capacitance of the MEMS device changes in response to movement of the MEMS device. An output subsystem is provided which responds to changes sensed by the sensing impedance, and which produces an output voltage signal. A filter filters the output voltage signal to produce a filtered output voltage signal. The filtered output voltage signal is indicative of a position of the MEMS device.

Panas, Robert Matthew↗

Reliability Issues of COTS MEMS Packaging

During the last decade, research and development of microelectromechanical systems (MEMS) has shown a significant promise for a variety of commercial applications including automobile and medical purposes.

Microelectromechanical systems MEMS reliability IC↗

Review of Polyimides Used in the Manufacturing of Micro Systems

Since their invention, polyimides have found numerous uses in MicroElectroMechanical Systems (MEMS) technology. Polyimides can act as photoresist, sacrificial layers, structural layers, and even as a replacement for silicon as the substrate during MEMS fabrication. They enable fabrication of both low and high aspect ratio devices. Polyimides have been used to fabricate expendable molds and reusable flexible molds. Development of a variety of devices that employ polyimides for sensor applications has occurred. Micro-robotic actuator applications include hinges, thermal actuators and residual stress actuators. Currently, polyimides are being used to create new sensors and devices for aerospace applications. This paper presents a review of some of the many uses of polyimides in the development of MEMS devices, including a new polyimide based MEMS fabrication process.

Wilson, William C.↗

MEMS reliability assurance guidelines for space applications

This guideline was developed as an aid to help in the understanding of Microelectromechanical Systems (MEMS) reliability and to facilitate the insertion of this technology into high reliability applications. Modeled after the GaAs MMIC Reliability Assurance Guideline for Space Applications by Kayali, et al., is was felt that a guideline would be more advantageous to people than a strict specification.

microelectromechanical↗

MEMS AO for Planet Finding

This slide presentation reviews a method for planet finding using microelectromechanical systems (MEMS) Adaptive Optics (AO). The use of a deformable mirror (DM) is described as a part of the instrument that was designed with a nulling interferometer. The strategy that is used is described in detail.

calibration interferometer↗

Measuring the Thickness and Elastic Properties of Electroactive Thin-Film Polymers Using Platewave Dispersion Data

Electroactive thin-film polymers are candidate sensors and actuators materials. They are also finding significant potential in muscle mechanisms and microelectromechanical systems (MEMS). In these applications, polymer thin films of thickness varying between 20 and 300 micrometers are utilized. The authors are currently studying the potential use of platewave dispersion curve measurements as an effective gauging tool for electroactive thin-film polymers.

sensors actuators film thickness measurements piez↗

Low Power, Wide Dynamic Range Carbon Nanotube Vacuum Gauges

This slide presentation presents carbon nanotube vacuum pressure sensor gauges that operate at low power and exhibit a wide-dynamic range based on microelectromechanical systems (MEMS) technology. The fabrication facility, and the formation process are shown. Pressure sensitivity was found to increase rapidly as the bias power was increased. In addition, by etching part of the thermal SiO2 beneath the tubes and minimizing heat conduction through the substrate, pressure sensitivity was extended toward lower pressures. Results are compared to a conventional thin film meander resistor, which was fabricated and whose pressure response was also measured for comparative purposes.

JEOL E-beam aligner↗

Fabrication of Freestanding Metallic Ni-Mo-W Microcantilever Beams With High Dimensional Stability

Recent studies have elucidated a promising balance of physical and mechanical properties of sputter deposited nickel-molybdenum-tungsten (Ni-Mo-W) films that have a unique nanotwinned microstructure and promising potential for use in high temperature microelectromechanical systems (MEMS). Here, the current study was undertaken to establish the feasibility of making nanotwinned Ni-Mo-W microcantilevers with standard micro- fabrication processing, to assess their dimensional stability, and to demonstrate the possibility of using nanotwinned Ni-Mo-W in metal MEMS devices. Deposition of Ni-Mo-W films in commercial sputtering chambers revealed a wide processing window for the formation of the requisite nanotwinned microstructure. Conventional photolithography and etchants were employed to shape blanket Ni-Mo-W films into freestanding microcantilever beams. Monitoring microcantilever deflections via interferometry provided a direct measure of residual stresses and overall dimensional stability. Heat treatments of 200° C and 400° C were used to mimic wafer bonding temperatures. At 400°C, microcantilevers exhibited modest stress relaxation, yielding beam deflection profiles on the nanometer scale and portending dimensional stability and control for future metal MEMS devices.

36 MATERIALS SCIENCE↗