Search NASA⌕ Search

SEARCH · Search NASA

Results for “microtomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Poisson’s ratio of eTPU molded bead foams in compression via in situ synchrotron X-ray microtomography

In situ synchrotron X-ray microtomography was used to characterize the bulk deformation behavior by computing the Poisson's ratio of expanded thermoplastic polyurethane (eTPU) molded bead foams used in footwear midsole during compression. Quantitative data on morphological characteristics were obtained using an iterative image processing workflow. Image correlation on the 4D datasets using DVC was performed to calculate the volumetric and axial strain to estimate the Poisson ratio. Strain maps from DVC showed the influence of variability in ligament thickness distribution on the global mechanical behavior exhibited which dominated the response seen in these bead foams. Lastly, our results showed a strong correlation between Poisson ratio and distribution of ligament thickness in foams.

36 MATERIALS SCIENCE↗

Microtomography and pore-scale modeling of two-phase Fluid Distribution

Synchrotron-based X-ray microtomography (micro CT) at the Advanced Light Source (ALS) line 8.3.2 at the Lawrence Berkeley National Laboratory produces three-dimensional micron-scale-resolution digital images of the pore space of the reservoir rock along with the spacial distribution of the fluids. Pore-scale visualization of carbon dioxide flooding experiments performed at a reservoir pressure demonstrates that the injected gas fills some pores and pore clusters, and entirely bypasses the others. Using 3D digital images of the pore space as input data, the method of maximal inscribed spheres (MIS) predicts two-phase fluid distribution in capillary equilibrium. Verification against the tomography images shows a good agreement between the computed fluid distribution in the pores and the experimental data. The model-predicted capillary pressure curves and tomography-based porosimetry distributions compared favorably with the mercury injection data. Thus, micro CT in combination with modeling based on the MIS is a viable approach to study the pore-scale mechanisms of CO{sub 2} injection into an aquifer, as well as more general multi-phase flows.

54 ENVIRONMENTAL SCIENCES↗

Deformation and fracture behavior of a laser powder bed fusion processed stainless steel: In situ synchrotron x-ray computed microtomography study

Tensile plastic deformation and fracture behavior of a laser powder bed fusion processed 316L stainless steel alloy was investigated in situ using high-resolution synchrotron x-ray computed microtomography (sXCT). Three different cases were studied: (1) specimen A1, near full-density with initial porosity of 0.04%, (2) specimen B1, initial lack-of-fusion (LOF) porosity of about 3% with the major axis of defects aligned nearly perpendicular to the tensile loading direction (LD), and (3) specimen B, similar to B1 but with the major axis of LOF defects aligned nearly parallel to LD. The effects of type, density, and orientation of defects in as-printed samples on plastic deformation and failure modes were studied by analyzing sXCT image sequences and quantitative defect properties. Specifically, the evolutions of porosity, size, aspect ratio, and angle of gas pores and LOF defects were characterized as a function of applied strain. Moreover, interactions between as-printed defects and deformation-induced crack propagation were investigated. The tensile behavior of specimen A1 was comparable to that of a commercial wrought plate. Furthermore, the quantitative in-situ sXCT results showed a void-growth phenomenon in A1 but without noticeable coalescence, resulting in a ductile cup-cone failure. Specimen B1 showed damage-driven brittle failure with limited plasticity due to early and rapid propagation of open voids. On the other hand, specimen B, with a similar amount of LOF defects as B1, showed deceivingly strong and ductile tensile behavior similar to A1 without any major crack propagations due to the favorable orientation relationship between LOF defects and the LD.

36 MATERIALS SCIENCE↗

About microcracking due to leaching in cementitious composites: X-ray microtomography description and numerical approach

Chemical shock of cement based materials leads to significant degradation of their physical properties. A typical scenario is a calcium leaching due to water (water with very low pH compared with that of pore fluid). The main objective of this paper is to evaluate the evolution of microstructure induced by leaching of a cementitious composite using synchrotron X-ray micro tomography, mainly from an experimental point of view. In this particular case, it was possible to identify cracking induced by leaching. After a description of the degradation mechanism and the X-ray synchrotron microtomographic analysis, numerical simulations are performed in order to show that cracking is induced by an initial pre-stressing of the composite, coupled with decalcification shrinkage and dramatic decrease in tensile strength during leaching. X-ray microtomography analysis allowed to make evidence of an induced microcracking in cementitious material submitted to leaching.

36 MATERIALS SCIENCE↗

X-ray microtomography shows pore structure and tortuosity in alkali-activated binders

Durability of alkali-activated binders is of vital importance in their commercial application, and depends strongly on microstructure and pore network characteristics. X-ray microtomography ({mu}CT) offers, for the first time, direct insight into microstructural and pore structure characteristics in three dimensions. Here, {mu}CT is performed on a set of sodium metasilicate-activated fly ash/slag blends, using a synchrotron beamline instrument. Segmentation of the samples into pore and solid regions is then conducted, and pore tortuosity is calculated by a random walker method. Segmented porosity and diffusion tortuosity are correlated, and vary as a function of slag content (slag addition reduces porosity and increases tortuosity), and sample age (extended curing gives lower porosity and higher tortuosity). This is particularly notable for samples with {>=} 50% slag content, where a space-filling calcium (alumino)silicate hydrate gel provides porosity reductions which are not observed for the sodium aluminosilicate ('geopolymer') gels which do not chemically bind water of hydration.

36 MATERIALS SCIENCE↗

Quantitative characterization of soil micro-aggregates: New opportunities from sub-micron resolution synchrotron X-ray microtomography

Soil microaggregates are the fundamental building block, at the micron scale, of the highly hierarchical structure of soils, and can exert a significant control on the local biological metabolism and microbial community partitioning. In this study we propose an analysis protocol for the morphometric characterization of complete soil microaggregates based on sub-micron resolution synchrotron X-ray microtomography. A comprehensive characterization of the aggregate morphology is the first step towards a complete characterization of the soil microaggregates, when trying to correlate morphometric parameters with physical and/or biological properties, or when building models (e.g., effective diffusivity, microbial distribution, etc.). In this study, we demonstrate our characterization approach on two single microaggregate samples from dramatically different soil environments: one from Kansas, primarily composed by inorganic particles, and one from Barrow (Alaska) dominated by plant fragments. A series of state-of-the-art morphometric analysis techniques have been employed providing quantitative results highlighting specific differences of the two samples. The role of the microstructure in a scenario microbial population development has been discussed and it has been found that the Barrow microaggregate seems to be more favorable, from a purely geometrical point of view, as also confirmed by a simple model presented in this work. Finally, the potential of this approach, when coupled with chemical and biological analysis for a fully comprehensive characterization of soil aggregates in the larger picture of enhanced biological activity, is evident.

54 ENVIRONMENTAL SCIENCES↗

X-ray microtomography of field-induced macro-structures in a ferrofluid.

X-ray microtomography is used to visualize, in-situ, the three-dimensional nature of the magnetic field induced macro-structures (>1 ?m) inside a bulk (not, vert, similar1 mm diameter) magnetite-particle-mineral oil ferrofluid sample. Columnar structures of not, vert, similar10 ?m diameter were seen under a 0.35 kG applied magnetic field, while labyrinth type structures not, vert, similar4 ?m in width were seen at 0.55 kG. The structures have height/width aspect ratios >100. The results show that the magnetite volume fraction is not constant within the structures and on average is considerably less than a random sphere packing model.

36 MATERIALS SCIENCE↗

X-ray microtomography

In this tutorial, we describe X-ray microtomography as a technique to nondestructively characterize material microstructure in three dimensions at a micron level spatial resolution. While commercially available laboratory scale instrumentation is available, we focus our attention on synchrotron-based systems, where we can exploit a high flux, monochromatic X-ray beam to produce high fidelity three-dimensional images. A brief description of the physics and the mathematical analysis behind the technique is followed by example applications to specific materials characterization problems, with a particular focus on the utilization of three-dimensional image processing that can be used to extract a wide range of useful information.

36 MATERIALS SCIENCE↗

Comparing the Purity of Rolled versus Evaporated Lithium Metal Films Using X-ray Microtomography

Here, we present a comparison of lithium metal films produced via rolling and thermal evaporation using synchrotron hard X-ray microtomography. In past studies of rolled lithium metal foils, a large number of C, O, and N impurities were found and identified as the key cause for failure in lithium metal cells. In this comparison, the X-ray tomography data show that the evaporated lithium metal films have an average impurity concentration of 19 particles/mm3 in comparison to 1350 particles/mm3 in the rolled lithium metal. An analysis of the inner substrate/lithium interface and outer lithium surface of the thermally evaporated film shows a much greater concentration of impurities at these interfaces, further emphasizing the importance of interface engineering in producing high-quality lithium metal batteries. Furthermore, we show that, if surface contamination can be avoided, it is possible to obtain lithium films with no impurities detectable by synchrotron hard X-ray tomography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Visualization of Li-Whisker with Grating-Interferometry-Based Tricontrast X-ray Microtomography

The lithium-ion battery has demonstrated tremendous economic and social impacts. Upon battery operation under different conditions, lithium changes its chemical state and physical formation, leading to undesired side reactions, e.g., lithium dendrite growth that degrades the cell performance and causes safety concerns. In situ detection and visualization of lithium metal in functional batteries could offer insights with both scientific and industrial significance but remain a frontier challenge. In this work, we demonstrate in situ three-dimensional imaging of lithium whisker using a grating-interferometry-based tricontrast X-ray microtomography method. Our approach explicitly reveals the micromorphology of the electrochemically developed porous lithium whisker with micrometer-level spatial resolution while offering sensitivity to the nanoporosity that is smaller than the nominal resolution limit. Our result reveals valuable structural information on the lithium whisker that is otherwise inaccessible. This method is also readily applicable to a broad range of battery research, including all-solid-state batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Wellbore Cement Degradation by Carbon Dioxide under Geologic Sequestration Conditions Using X-ray Computed Microtomography

ABSTRACT: X-ray microtomography (XMT), a nondestructive three-dimensional imaging technique, was applied to demonstrate its capability to visualize the mineralogical alteration and microstructure changes in hydrated Portland cement exposed to carbon dioxide under geologic sequestration conditions. Steel coupons and basalt fragments were added to the cement paste in order to simulate cement-steel and cement-rock interfaces. XMT image analysis showed the changes of material density and porosity in the degradation front (density: 1.98 g/cm3, porosity: 40%) and the carbonated zone (density: 2.27 g/cm3, porosity: 23%) after reaction with CO2- saturated water for 5 months compared to unaltered cement (density: 2.15 g/cm3, porosity: 30%). Three-dimensional XMT imaging was capable of displaying spatially heterogeneous alteration in cement pores, calcium carbonate precipitation in cement cracks, and preferential cement alteration along the cement-steel and cement-rock interfaces. This result also indicates that the interface between cement and host rock or steel casing is likely more vulnerable to a CO2 attack than the cement matrix in a wellbore environment. It is shown here that XMT imaging can potentially provide a new insight into the physical and chemical degradation of wellbore cement by CO2 leakage.

Imaging Wellbore Cement Degradation by Carbon Diox↗

Spatial resolution of synchrotron x-ray microtomography in high energy range: Effect of x-ray energy and sample-to-detector distance

Spatial resolution of three-dimensional images obtained by synchrotron X-ray microtomography technique is evaluated using cyclic bar patterns machined on a steel wire. Influences of X-ray energy and the sample-to-detector distance on spatial resolution were investigated. High X-ray energies of 33-78 keV are applied due to the high X-ray absorption of transition metals. Best spatial resolution of about 1.2 {mu}m pitch was observed at the sample-to-detector distance range of 20-110 mm and at the energy range of 68-78 keV. Several factors such as X-ray scattering and diffraction phenomena affecting the degradation of spatial resolution are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of liquid gallium as a function of pressure and temperature using synchrotron x-ray microtomography and x-ray diffraction

The volume change of liquid and solid gallium has been studied as a function of pressure and temperature up to 3.02 GPa at 300 K and up to 3.63 GPa at 330 K using synchrotron x-ray microtomography combined with energy dispersive x-ray diffraction techniques. Two sets of directly measured P-V data at 300 K and 330 K were obtained from 3D tomography reconstruction data, and the corresponding isothermal bulk moduli were determined as 23.6 (0.5) GPa and 24.6 (0.4) GPa, respectively. The existence of a liquid-liquid phase transition region is proposed based on the abnormal compressibility of Ga melt at about 2.44 GPa and 330 K conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography

An experimental study about the anisotropic wetting behavior of a surface patterned with parallel grooves is presented as an application example of a novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography. Shape of glycerin droplets on such surface is investigated by X-ray micro computed tomography (microCT) acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution. The reconstructed drop volumes enable to estimate the exact volumes of the drops, their base contours, and 3D static contact angles, based on true cross-sections of the drop-surface couple. Droplet base contours are compared to approximate geometrical contour shapes proposed in the literature. Contact angles along slices parallel and perpendicular to the grooves direction are compared with each other. The effect of the sessile drop volume on the wetting behavior is discussed. The proposed technique, which is applicable for any structured surface, enables the direct measure of Wenzel ratio based on the microCT scan in the wetted region usually inapproachable by any others. Comparisons with simplified models are presented and congruence of results with respect to the minimum resolution needed is evaluated and commented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent progress of hard x-ray imaging microscopy and microtomography at BL37XU of SPring-8

A hard x-ray imaging microscopy and microtomography system is now being developed at the beamline 37XU of SPring-8. In the latest improvement, a spatial resolution of about 50 nm is achieved in two-dimensional imaging at 6 keV x-ray energy using a Fresnel zone plate objective with an outermost zone width of 35 nm. In the tomographic measurement, a spatial resolution of about 100 nm is achieved at 8 keV using an x-ray guide tube condenser optic and a Fresnel zone plate objective with an outermost zone width of 50 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of ∼1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional reconstruction of statistically optimal unit cells of polydisperse particulate composites from microtomography

In this paper, we present a systematic approach for characterization and reconstruction of statistically optimal representative unit cells of polydisperse particulate composites. Microtomography is used to gather rich three-dimensional data of a packed glass bead system. First-, second-, and third-order probability functions are used to characterize the morphology of the material, and the parallel augmented simulated annealing algorithm is employed for reconstruction of the statistically equivalent medium. Both the fully resolved probability spectrum and the geometrically exact particle shapes are considered in this study, rendering the optimization problem multidimensional with a highly complex objective function. A ten-phase particulate composite composed of packed glass beads in a cylindrical specimen is investigated, and a unit cell is reconstructed on massively parallel computers. Further, rigorous error analysis of the statistical descriptors (probability functions) is presented and a detailed comparison between statistics of the voxel-derived pack and the representative cell is made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact and flexible induction furnace for in situ X-ray microradiograhy and computed microtomography at Elettra: design, characterization and first tests

A compact and versatile induction furnace for in situ high-resolution synchrotron and laboratory hard X-ray microradiography and computed microtomography is described. The furnace can operate from 773 to 1723 K. Its programmable controller enables the user to specify multiple heating and cooling ramp rates as well as variable dwell times at fixed temperatures allowing precise control of heating and cooling rates to within 5 K. The instrument can work under a controlled atmosphere. Thanks to the circular geometry of the induction coils, the heat is homogeneously distributed in the internal volume of the graphite cell ( ca . 150 mm 3 ) where the sample holder is located. The thermal gradient within the furnace is less than 5 K over a height of ca . 5 mm. This new furnace design is well suited to the study of melting and solidification processes in geomaterials, ceramics and several metallic alloys, allowing fast heating (tested up to 6.5 K s -1 ) and quenching (up to 21 K s -1 ) in order to freeze the sample microstructure and chemistry under high-temperature conditions. The sample can be held at high temperatures for several hours, which is essential to follow phenomena with relatively slow dynamics, such as crystallization processes in geomaterials. The utility of the furnace is demonstrated through a few examples of experimental applications performed at the Elettra synchrotron laboratory (Trieste, Italy).

Kudrna Prašek, Marko↗