Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Non-Ionizing Millimeter Waves Non-Thermal Radiation of Saccharomyces cerevisiae—Insights and Interactions

Non-ionizing millimeter-waves (MMW) interact with cells in a variety of ways. Here the inhibited cell division effect was investigated using 85–105 GHz MMW irradiation within the International Commission on Non-Ionizing Radiation Protection (ICNIRP) non-thermal 20 mW/cm 2 safety standards. Irradiation using a power density of about 1.0 mW/cm 2 SAR over 5–6 h on 50 cells/μL samples of Saccharomyces cerevisiae model organism resulted in 62% growth rate reduction compared to the control (sham). The effect was specific for 85–105 GHz range and was energy- and cell density-dependent. Irradiation of wild type and Δrad52 (DNA damage repair gene) deleted cells presented no differences of colony growth profiles indicating non-thermal MMW treatment does not cause permanent genetic alterations. Dose versus response relations studied using a standard horn antenna (~1.0 mW/cm 2 ) and compared to that of a compact waveguide (17.17 mW/cm 2 ) for increased power delivery resulted in complete termination of cell division via non-thermal processes supported by temperature rise measurements. We have shown that non-thermal MMW radiation has potential for future use in treatment of yeast related diseases and other targeted biomedical outcomes.

59 BASIC BIOLOGICAL SCIENCES↗

The Atacama Cosmology Telescope: Detection of Millimeter-wave Transient Sources

Here we report on the serendipitous discovery of three transient millimeter-wave sources using data from the Atacama Cosmology Telescope. The first, detected at R.A. = 273.8138, decl. = -49.4628 at ~50σ total, brightened from less than 5 mJy to at least 1100 mJy at 150 GHz with an unknown rise time shorter than 13 days, during which the increase from 250 mJy to 1100 mJy took only 8 minutes. Maximum flux was observed on 2019 November 8. The source's spectral index in flux between 90-150 GHz was positive, α = 1.5 ± 0.2. The second, detected at R.A. = 105.1584, decl. = -11.2434 at ~20σ total, brightened from less than 20 mJy to at least 300 mJy at 150 GHz with an unknown rise time shorter than 8 days. Maximum flux was observed on 2019 December 15. Its spectral index was also positive, α = 1.8 ± 0.2. The third, detected at R.A. = 301.9952, decl. = 16.1652 at ~40σ total, brightened from less than 8 mJy to at least 300 mJy at 150 GHz over a day or less but decayed over a few days. Maximum flux was observed on 2018 September 11. Its spectrum was approximately flat, with a spectral index of α = -0.2 ± 0.1. None of the sources were polarized to the limits of these measurements. The two rising-spectrum sources are coincident in position with M and K stars, while the third is coincident with a G star.

79 ASTRONOMY AND ASTROPHYSICS↗

BASS XXXII: Studying the Nuclear Millimeter-wave Continuum Emission of AGNs with ALMA at Scales ≲100–200 pc

To understand the origin of nuclear (≲100 pc) millimeter-wave (mm-wave) continuum emission in active galactic nuclei (AGNs), we systematically analyzed subarcsecond resolution Band-6 (211–275 GHz) Atacama Large Millimeter/submillimeter Array data of 98 nearby AGNs (z < 0.05) from the 70 month Swift/BAT catalog. The sample, almost unbiased for obscured systems, provides the largest number of AGNs to date with high mm-wave spatial resolution sampling (~1–200 pc), and spans broad ranges of 14–150 keV luminosity {$40\lt \mathrm{log}[{L}_{14-150}/(\mathrm{erg}\,{{\rm{s}}}^{-1})]\lt 45$}, black hole mass $[5\lt \mathrm{log}({M}_{\mathrm{BH}}/{M}_{\odot })\lt 10$], and Eddington ratio ($-4\lt \mathrm{log}{\lambda }_{\mathrm{Edd}}\lt 2$). We find a significant correlation between 1.3 mm (230 GHz) and 14–150 keV luminosities. Its scatter is ≈0.36 dex, and the mm-wave emission may serve as a good proxy of the AGN luminosity, free of dust extinction up to N H ~ 10 26 cm –2 . While the mm-wave emission could be self-absorbed synchrotron radiation around the X-ray corona according to past works, we also discuss different possible origins of the mm-wave emission: AGN-related dust emission, outflow-driven shocks, and a small-scale (<200 pc) jet. The dust emission is unlikely to be dominant, as the mm-wave slope is generally flatter than expected. Also, due to no increase in the mm-wave luminosity with the Eddington ratio, a radiation-driven outflow model is possibly not the common mechanism. Furthermore, we find independence of the mm-wave luminosity on indicators of the inclination angle from the polar axis of the nuclear structure, which is inconsistent with a jet model whose luminosity depends only on the angle.

79 ASTRONOMY AND ASTROPHYSICS↗

Asteroid Measurements at Millimeter Wavelengths with the South Pole Telescope

Abstract We present the first measurements of asteroids in millimeter wavelength data from the South Pole Telescope (SPT), which is used primarily to study the cosmic microwave background (CMB). We analyze maps of two ∼270 deg2 sky regions near the ecliptic plane, each observed with the SPTpol camera ∼100 times over 1 month. We subtract the mean of all maps of a given field, removing static sky signal, and then average the mean-subtracted maps at known asteroid locations. We detect three asteroids—(324) Bamberga, (13) Egeria, and (22) Kalliope—with signal-to-noise ratios (S/N) of 11.2, 10.4, and 6.1, respectively, at 2.0 mm (150 GHz); we also detect (324) Bamberga with an S/N of 4.1 at 3.2 mm (95 GHz). We place constraints on these asteroids’ effective emissivities, brightness temperatures, and light-curve modulation amplitude. Our flux density measurements of (324) Bamberga and (13) Egeria roughly agree with predictions, while our measurements of (22) Kalliope suggest lower flux, corresponding to effective emissivities of 0.64 ± 0.11 at 2.0 and < 0.47 at 3.2 mm. We predict the asteroids detectable in other SPT data sets and find good agreement with detections of (772) Tanete and (1093) Freda in recent data from the SPT-3G camera, which has ∼10× the mapping speed of SPTpol. This work is the first focused analysis of asteroids in data from CMB surveys, and it demonstrates we can repurpose historic and future data sets for asteroid studies. Future SPT measurements can help constrain the distribution of surface properties over a larger asteroid population.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared-Transparent Semiconductor Membranes for Electromagnetic Interference Shielding of Millimeter Waves

Here, it is demonstrated that single-crystalline and highly doped GaAs membranes are excellent candidates for realizing infrared-transparent shields of electromagnetic interference at millimeter frequencies. Measured optical transmittance spectra for the semiconductor membranes show resonant features between 750 and 2500 nm, with a 100% maximum transmittance. The shielding effectiveness of the membranes is extracted from measured scattering parameters between 65 and 85 GHz. Selected GaAs membranes and membranes/polyamide films exhibit shielding effectiveness ranging from 22 to 40 dB, which are suitable values to ensure the safe operation of infrared devices for commercial applications. Theoretical calculations based on a plane wave model show that the interplay of primary reflection and multiple internal reflections of the radio-frequency waves results in broadband shielding capabilities of the membrane between 10 and 300 GHz.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Planar Self-similar Antennas for Broadband Millimeter-Wave Measurements

Self-similar antennas offer extremely broadband functionality and easily scalable designs. Self-similar designs with a four-arm layout are also suited for dual polarization through excitations of opposing arms, although there has only been limited use of them for millimeter-wave detectors. These antennas have been used for measurements of the cosmic microwave background (CMB), which encompass a wide frequency range and are now actively focusing more on polarization anisotropies. Here, we analyze multiple planar self-similar antenna designs with simulations in high-frequency structure simulator and ongoing physical testing. They all exhibit broadband operation between 130 and 230 GHz and can couple to both linear polarizations through the previously mentioned four-arm symmetry. Furthermore, simulations include each antenna design coupled to an extended hemispherical, AR-coated lenslet. From these, a basic bowtie-like arm design produced minimal polarization wobble with moderate beam efficiency, while a hybrid trapezoidal design provided high beam efficiency with small polarization wobble. Current fabrication versions of each are being tested, coupled to multichroic microwave kinetic inductance detectors. These planar self-similar antennas, when implemented in CMB and other detectors, could improve observations while simultaneously simplifying fabrication and detector layout.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Millimeter-Scale Exfoliation of hBN with Tunable Flake Thickness for Scalable Encapsulation

As a two-dimensional (2D) dielectric material, hexagonal boron nitride (hBN) is in high demand for applications in photonics, nonlinear optics, and nanoelectronics. Unfortunately, the high-throughput preparation of macroscopic-scale, high-quality hBN flakes with controlled thickness is an ongoing challenge, limiting device fabrication and technological integration. In this report we present a metal thin-film exfoliation method to prepare hBN flakes with millimeter-scale dimension, near-unity yields, and tunable flake thickness distribution from 1-7 layers, a substantial improvement over scotch tape exfoliation. The single crystallinity and high quality of the exfoliated hBN are demonstrated with optical microscopy, atomic force microscopy, Raman spectroscopy, and second harmonic generation. We further explore a possible mechanism for the effectiveness and selectivity based on thin-film residual stress measurements, density functional theory calculations, and transmission electron microscopy imaging of the deposited metal films. We find that the magnitude of the residual tensile stress induced by thin film deposition plays a key role in determining exfoliated flake thickness in a manner which closely resembles 3D semiconductor spalling. Lastly, we demonstrate that our exfoliated, large-area hBN flakes can be readily incorporated as encapsulating layers for other 2D monolayers. Altogether, this method brings us one step closer to the high throughput, mass production of hBN-based 2D photonic, optoelectronic, and quantum devices.

2D materials↗

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

Millimeter-wave observations of Euclid Deep Field South using the South Pole Telescope: A data release of temperature maps and catalogs

Context. The South Pole Telescope third-generation camera (SPT-3G) has observed over 10,000 square degrees of sky at 95, 150, and 220 GHz (3.3, 2.0, 1.4 mm, respectively) and will significantly overlap the ongoing 14,000 square-degree Euclid Wide Survey. The Euclid collaboration recently released Euclid Deep Field South (EDF-S) observations of 23 square degrees at wide field depths in the first quick data release (Q1). Aims. With the goal of releasing complementary millimeter-wave data and encouraging legacy science, we performed dedicated observations of a 57-square-degree field overlapping the EDF-S. Methods. The observing time totaled 20 days, and we reached noise depths of 4.3, 3.8, and 13.2 $μ$K-arcmin at 95, 150, and 220 GHz, respectively. Results. In this work we present the temperature maps and two catalogs constructed from these data. The emissive source catalog contains 601 objects (334 inside EDF-S) with 54% synchrotron-dominated sources and 46% thermal dust emission-dominated sources. The 5$σ$ detection thresholds are 1.7, 2.0, and 6.5 mJy in the three bands. The cluster catalog contains 217 cluster candidates (121 inside EDF-S) with median mass $M_{500c}=2.12 \times 10^{14} M_{\odot}/h_{70}$ and median redshift $z$ = 0.70, corresponding to an order-of-magnitude improvement in cluster density over previous tSZ-selected catalogs in this region (3.81 clusters per square degree). Conclusions. The overlap between SPT and Euclid data will enable a range of multiwavelength studies of the aforementioned source populations. This work serves as the first step toward joint projects between SPT and Euclid and provides a rich dataset containing information on galaxies, clusters, and their environments.

Archipley, M. [Chicago U., Astron. Astrophys. Ctr.↗

Thermal kinetic inductance detectors for millimeter-wave detection

Thermal Kinetic-Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of millimeter-wave instruments. In this paper, we first discuss the expected noise sources in TKIDs and derive the limits where the phonon noise contribution dominates over the other detector noise terms: generation–recombination, amplifier, and two-level system noise. Second, we characterize aluminum TKIDs in a dark environment. We present measurements of TKID resonators with quality factors of about 10 5 at 80 mK. We also discuss the bolometer thermal conductance, heat capacity, and time constants. These were measured by the use of a resistor on the thermal island to excite the bolometers. These dark aluminum TKIDs demonstrate a noise equivalent power, NEP = 2 × 10 − 17 W / Hz , with a 1 / f knee at 0.1 Hz, which provides background noise limited performance for ground-based telescopes observing at 150 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A co-axial electron gun to generate millimeter-wave RF using the two-stream instability

A novel source for broadband millimeter-wave RF is being designed at Los Alamos National Laboratory utilizing the two-stream instability. This RF source offers the potential for consistent output power over a large bandwidth on a single device. The source is designed to use two co-axial electron beams coupled into solenoidal magnetic fields. This is accomplished using two cathodes independently modulated nested in each other. The electron beam energy from the innermost cathode will fall in the range between 15 and 20 keV with the beam energy from the outer cathode being 75%–95% of the inner beam energy. In order to efficiently match the beam from the outer cathode into the solenoidal magnetic field, shields are used around the cathodes to shape the electric field in the gun region to extend the electrostatic focal length of the beams for better coupling into the magnetic field. As a result, we present the design of electron guns and expected performance using Trak simulations.

47 OTHER INSTRUMENTATION↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

Millimeter-wave electromagnetic monitoring for liquid metal droplet-on-demand printing

As new printing approaches emerge, in situ diagnostics to monitor the print quality in real-time become essential for long-term monitoring and feedback control. In this article, we present a millimeter-wave electromagnetic monitoring approach for liquid metal droplet-on-demand printing to support the high-speed and real-time evaluation of droplet ejection. An open-ended rectangular waveguide is placed perpendicular to a jetted droplet stream and operated at a continuous-wave frequency of 40 GHz. Liquid metal droplets with diameters as low as 1.2 mm are characterized, and droplet jetting events on the order of 500 μm are detected at ejection rates up to 80 Hz. The measured results demonstrate that trends at the macro-level (large-scale print variation and anomalies at the nozzle tip) as well as micro-level (droplet size, position, and dynamics) can be detected using this technique.

42 ENGINEERING↗

Reactive burn model calibration using high-throughput initiation experiments at sub-millimeter length scales

We report a first-of-its-kind model calibration was performed using Sandia National Laboratories’ high-throughput initiation (HTI) experiment for two types of vapor-deposited explosive films consisting of hexanitrostilbene (HNS) or pentaerythritol tetranitrate (PETN). These films exhibit prompt initiation, and they reach steady detonation at sub-millimeter length scales. Following prior work on HNS, we test the hypothesis of approximating these explosive films as fine-grained homogeneous solids with simple Arrhenius kinetics burn models. The model calibration process is described herein using a single-step as well as a two-step Arrhenius rate law, and it consists of systematic parameter sampling leading to a reduction in the model degrees of freedom. Multiple local minima are observed; results are given for seven different optimized parameter sets. Each model set is further evaluated in a two-dimensional simulation of the critical failure thickness for a sustained detonation. Overall, the two-step Arrhenius kinetics model captures the observed behavior for HNS; however, neither model produces a good fit to the PETN data. We hypothesize that the HTI results for PETN correspond to a heterogeneous response, owing to the smaller reaction zone of PETN compared to HNS (i.e., it does not homogenize the fine-grained hot spots as well). Future work should consider using the ignition and growth model for PETN, as well as other reactive burn models such as xHVRB, AWSD, PiSURF, and CREST.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗