Search NASA⌕ Search

SEARCH · Search NASA

Results for “millimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An On-Chip Superconducting Kinetic Inductance Fourier Transform Spectrometer for Millimeter-Wave Astronomy

An on-chip FTS consists of two waveguides coupled to long superconducting transmission lines (STLs) (similar to 620 mm) using two coupling probes. The signal propagating on one of the STLs is phase-shifted with respect to the other line with a bias current that affects the nonlinear dependence of kinetic inductance, Lk(I)of the STL material. Here we describe the design and simulation of a superconducting on-chip FTS coupled to a dual polarization W-band (90-110 GHz) waveguide. These devices have applications in ground-based and space-based millimeter-wave spectral surveys.

Fourier transform spectrometer↗

Preparation of high orbital angular momentum Rydberg states by optical-millimeter-wave STIRAP

Rydberg states of molecules are intrinsically challenging to study due to the presence of fast non-radiative decay pathways, such as predissociation. However, selectively exciting Rydberg states with values of the orbital angular momentum (ℓ) ℓ ≳ 3 is a productive strategy to minimize this rapid decay and to populate molecular Rydberg states with lifetimes that approach those of atoms. Here, in this proof-of-principle demonstration, we transfer population to an nf Rydberg state of the calcium atom by stimulated Raman adiabatic passage, in which an optical and a millimeter-wave field couple the initial and final states via an intermediate nd Rydberg state. Numerical simulations reproduce the observed time and frequency dependences of the population transfer and suggest the utility of this scheme to populate high-ℓ Rydberg states of molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

BASS XXXII: Studying the Nuclear Millimeter-wave Continuum Emission of AGNs with ALMA at Scales ≲100–200 pc

To understand the origin of nuclear (≲100 pc) millimeter-wave (mm-wave) continuum emission in active galactic nuclei (AGNs), we systematically analyzed subarcsecond resolution Band-6 (211–275 GHz) Atacama Large Millimeter/submillimeter Array data of 98 nearby AGNs (z < 0.05) from the 70 month Swift/BAT catalog. The sample, almost unbiased for obscured systems, provides the largest number of AGNs to date with high mm-wave spatial resolution sampling (~1–200 pc), and spans broad ranges of 14–150 keV luminosity {$40\lt \mathrm{log}[{L}_{14-150}/(\mathrm{erg}\,{{\rm{s}}}^{-1})]\lt 45$}, black hole mass $[5\lt \mathrm{log}({M}_{\mathrm{BH}}/{M}_{\odot })\lt 10$], and Eddington ratio ($-4\lt \mathrm{log}{\lambda }_{\mathrm{Edd}}\lt 2$). We find a significant correlation between 1.3 mm (230 GHz) and 14–150 keV luminosities. Its scatter is ≈0.36 dex, and the mm-wave emission may serve as a good proxy of the AGN luminosity, free of dust extinction up to N H ~ 10 26 cm –2 . While the mm-wave emission could be self-absorbed synchrotron radiation around the X-ray corona according to past works, we also discuss different possible origins of the mm-wave emission: AGN-related dust emission, outflow-driven shocks, and a small-scale (<200 pc) jet. The dust emission is unlikely to be dominant, as the mm-wave slope is generally flatter than expected. Also, due to no increase in the mm-wave luminosity with the Eddington ratio, a radiation-driven outflow model is possibly not the common mechanism. Furthermore, we find independence of the mm-wave luminosity on indicators of the inclination angle from the polar axis of the nuclear structure, which is inconsistent with a jet model whose luminosity depends only on the angle.

79 ASTRONOMY AND ASTROPHYSICS↗

Millimeter-wave high-wavenumber scattering diagnostic developments on EAST and NSTX-U

A pioneering 4-channel, high-k poloidal, millimeter-wave collective scattering system has been successfully developed for the Experimental Advanced Superconducting Tokamak (EAST). Engineered to explore high-k electron density fluctuations, this innovative system deploys a 270 GHz mm-wave probe beam launched from Port K and directed toward Port P (both ports lie on the midplane and are 110° part), where large aperture optics capture radiation across four simultaneous scattering angles. Tailored to measure density fluctuations with a poloidal wavenumber of up to 20 cm -1 , this high-k scattering system underwent rigorous laboratory testing in 2023, and the installation is currently being carried out on EAST. Its primary purpose lies in scrutinizing ion and electron-scale instabilities, such as the electron temperature gradient (ETG) mode, by furnishing measurements of the k θ (poloidal wavenumber) spectrum. This advancement significantly bolsters the capacity to probe high-k electron density fluctuations within the framework of EAST. Finally, beam tracing and data interpretation modules developed for both EAST and NSTX-U high-k scattering diagnostics are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics

Here, we present two prescriptions for broadband (~77 -252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano–convex elements, the other for densely packed arrays of quasi-optical elements—in our case, 5 mm diameter half-spheres (called “lenslets”). The coatings comprise three layers of commercially available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly, while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions, then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97±2)% transmittance, and the lenslet coating sample achieves (94±3)% transmittance.

36 MATERIALS SCIENCE↗

A High Gain Lens-Coupled On-Chip Antenna Module for Miniature-Sized Millimeter-Wave Wireless Transceivers

This paper presents high gain and compact Transmit/Receive (TX/RX) integrated antennas in a standard BiCMOS 130nm technology for millimeter-scale millimeter-wave (mm-wave) applications, including high data rate radios and high resolution radars. The proposed TX/RX antenna module utilizes an integrated dipole antenna for the receiver and a slot antenna for the transmitter, placed orthogonally. The achieved gain and radiation efficiency are 5.7dBi and 41.3% for the slot antenna, respectively, and 6dBi and 39% for the dipole antenna. The link budget is improved by 16dB by optimization on the geometry aswell as application of a high resistivity hemispheric silicon dielectric lens.

Engineering↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

New millimeter-wave diagnostics to locally probe internal density and magnetic field fluctuations in National Spherical Torus Experiment-Upgrade (invited)

A set of new millimeter-wave diagnostics will deliver unique measurement capabilities for National Spherical Torus Experiment-Upgrade to address a variety of plasma instabilities believed to be important in determining thermal and particle transport, such as micro-tearing, global Alfvén eigenmodes, kinetic ballooning, trapped electron, and electron temperature gradient modes. These diagnostics include a new integrated intermediate-k Doppler backscattering (DBS) and cross-polarization scattering (CPS) system (four channels, 82.5–87 GHz) to measure density and magnetic fluctuations, respectively. The system can access reasonably large normalized wavenumbers k θ ρ s ranging from ≤0.5 to 15 (where ion sound gyroradius ρ s = 1 cm and k θ is the binormal density turbulence wavenumber). The system addresses the challenges for making useful DBS/CPS measurements with a remote control of launch polarization (X- or O-mode), probed wavenumber, polarization match of the launch beam with the edge magnetic field pitch angle, and beam steering of the launched beam for wave-vector alignment. In addition, a low-k DBS system consisting of eight fixed frequencies (34–52 GHz) and four tunable frequencies (55–75 GHz) for low-k density turbulence and fast ion physics will be located at a nearby port location. Finally, the combined systems cover the near LCFS and pedestal regions (34–52 GHz), the pedestal or mid-radius (50–75 GHz), and core plasmas (82.5–87 GHz).

47 OTHER INSTRUMENTATION↗

Precise equilibrium structures of 1 H - and 2 H -1,2,3-triazoles (C 2 H 3 N 3 ) by millimeter-wave spectroscopy

The 1H- and 2H-1,2,3-triazoles are isomeric five-membered ring, aromatic heterocycles that may undergo chemical equilibration by virtue of intramolecular hydrogen migration (tautomerization). Using millimeter-wave spectroscopy in the 130–375 GHz frequency range, we measured the spectroscopic constants for thirteen 1H-1,2,3-triazole and sixteen 2H-1,2,3-triazole isotopologues. Herein, we provide highly accurate and highly precise semi-experimental equilibrium (r e SE ) structures for the two tautomers based on the spectroscopic constants of each set of isotopologues, together with vibration–rotation interaction and electron-mass distribution corrections calculated using coupled-cluster singles, doubles, and perturbative triples calculations [CCSD(T)/cc-pCVTZ]. The resultant structures are compared with a “best theoretical estimate” (BTE), which has recently been shown to be in exceptional agreement with the semi-experimental equilibrium structures of other aromatic molecules. Bond distances of the 1H tautomer are determined to <0.0008 Å and bond angles to <0.2°. For the 2H tautomer, bond angles are also determined to <0.2°, but bond distances are less precise (2σ ≤ 0.0015). Finally, agreement between BTE and r e SE values is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal kinetic inductance detectors for millimeter-wave detection

Thermal Kinetic-Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of millimeter-wave instruments. In this paper, we first discuss the expected noise sources in TKIDs and derive the limits where the phonon noise contribution dominates over the other detector noise terms: generation–recombination, amplifier, and two-level system noise. Second, we characterize aluminum TKIDs in a dark environment. We present measurements of TKID resonators with quality factors of about 10 5 at 80 mK. We also discuss the bolometer thermal conductance, heat capacity, and time constants. These were measured by the use of a resistor on the thermal island to excite the bolometers. These dark aluminum TKIDs demonstrate a noise equivalent power, NEP = 2 × 10 − 17 W / Hz , with a 1 / f knee at 0.1 Hz, which provides background noise limited performance for ground-based telescopes observing at 150 GHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter-wave electromagnetic monitoring for liquid metal droplet-on-demand printing

As new printing approaches emerge, in situ diagnostics to monitor the print quality in real-time become essential for long-term monitoring and feedback control. In this article, we present a millimeter-wave electromagnetic monitoring approach for liquid metal droplet-on-demand printing to support the high-speed and real-time evaluation of droplet ejection. An open-ended rectangular waveguide is placed perpendicular to a jetted droplet stream and operated at a continuous-wave frequency of 40 GHz. Liquid metal droplets with diameters as low as 1.2 mm are characterized, and droplet jetting events on the order of 500 μm are detected at ejection rates up to 80 Hz. The measured results demonstrate that trends at the macro-level (large-scale print variation and anomalies at the nozzle tip) as well as micro-level (droplet size, position, and dynamics) can be detected using this technique.

42 ENGINEERING↗

Planar Self-similar Antennas for Broadband Millimeter-Wave Measurements

Self-similar antennas offer extremely broadband functionality and easily scalable designs. Self-similar designs with a four-arm layout are also suited for dual polarization through excitations of opposing arms, although there has only been limited use of them for millimeter-wave detectors. These antennas have been used for measurements of the cosmic microwave background (CMB), which encompass a wide frequency range and are now actively focusing more on polarization anisotropies. Here, we analyze multiple planar self-similar antenna designs with simulations in high-frequency structure simulator and ongoing physical testing. They all exhibit broadband operation between 130 and 230 GHz and can couple to both linear polarizations through the previously mentioned four-arm symmetry. Furthermore, simulations include each antenna design coupled to an extended hemispherical, AR-coated lenslet. From these, a basic bowtie-like arm design produced minimal polarization wobble with moderate beam efficiency, while a hybrid trapezoidal design provided high beam efficiency with small polarization wobble. Current fabrication versions of each are being tested, coupled to multichroic microwave kinetic inductance detectors. These planar self-similar antennas, when implemented in CMB and other detectors, could improve observations while simultaneously simplifying fabrication and detector layout.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic nanostructures and composites for millimeter wave absorption

A product includes a nanostructure having a core and a shell. The core has a coercive field of at least 3 kOe and the shell has a saturation magnetization of at least 50 emu per gram. A product includes a nanostructure having a core and a shell. The shell has a coercive field of at least 3 kOe and the core has a saturation magnetization of at least 50 emu per gram. A method includes forming core/shell nanostructures and forming millimeter wave absorbers including the core/shell nanostructures and a support structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Feasibility Study of Millimeter Wave Radars For Safeguards Applications

Containment and surveillance are fundamental measures in nuclear safeguards. Techniques such as video surveillance and laser curtain for containment provide effective monitoring in areas where maintaining continuity of knowledge is required. These systems, however, can be susceptible to loss of monitoring capabilities under certain environmental conditions such as poor visibility (i.e. low light conditions, smoke, fog, etc.) or extended power loss past the duration that the backup power system is designed for. Brookhaven National Laboratory has been investigating the feasibility of millimeter waves (mmWave) as a new perimeter seal in which radio frequency waves in the range of 60-64 GHz are used to detect and monitor objects of interest. Signals in this frequency range are not susceptible to environmental conditions. For proof-of-concept tests, mmWave sensors from Texas Instruments (TI), specificallyIWR6843, are used in a test bed at BNL's Waste Management facility to simulate the operations at nuclear facilities. The unique design of TI mmWave sensors requires less memory and power consumption compared to counterpart systems. These devices are capable of exporting 3D point-cloud data, which is visualized graphically and compared to videos recorded at the same time to validate the performance of the mmWave sensor. A set of experiments were planned to test the feasibility of the mmWave in this application, including monitoring static containers in a storage area and detecting intrusions at the boundaries of the area. In addition, the experiments also identify potential blind spots relative to sensor position and utilize multiple operating sensors simultaneously to reduce or eliminate such blind spots. The optimal positioning of multiple sensors was determined for the experimental room configuration. In this paper, we will discuss the details of this novel perimeter sealing concept and present the test results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Millimeter-wave observations of Euclid Deep Field South using the South Pole Telescope: A data release of temperature maps and catalogs

Context. The South Pole Telescope third-generation camera (SPT-3G) has observed over 10,000 square degrees of sky at 95, 150, and 220 GHz (3.3, 2.0, 1.4 mm, respectively) and will significantly overlap the ongoing 14,000 square-degree Euclid Wide Survey. The Euclid collaboration recently released Euclid Deep Field South (EDF-S) observations of 23 square degrees at wide field depths in the first quick data release (Q1). Aims. With the goal of releasing complementary millimeter-wave data and encouraging legacy science, we performed dedicated observations of a 57-square-degree field overlapping the EDF-S. Methods. The observing time totaled 20 days, and we reached noise depths of 4.3, 3.8, and 13.2 $μ$K-arcmin at 95, 150, and 220 GHz, respectively. Results. In this work we present the temperature maps and two catalogs constructed from these data. The emissive source catalog contains 601 objects (334 inside EDF-S) with 54% synchrotron-dominated sources and 46% thermal dust emission-dominated sources. The 5$σ$ detection thresholds are 1.7, 2.0, and 6.5 mJy in the three bands. The cluster catalog contains 217 cluster candidates (121 inside EDF-S) with median mass $M_{500c}=2.12 \times 10^{14} M_{\odot}/h_{70}$ and median redshift $z$ = 0.70, corresponding to an order-of-magnitude improvement in cluster density over previous tSZ-selected catalogs in this region (3.81 clusters per square degree). Conclusions. The overlap between SPT and Euclid data will enable a range of multiwavelength studies of the aforementioned source populations. This work serves as the first step toward joint projects between SPT and Euclid and provides a rich dataset containing information on galaxies, clusters, and their environments.

Archipley, M. [Chicago U., Astron. Astrophys. Ctr.↗