Search NASA⌕ Search

SEARCH · Search NASA

Results for “miniature mass spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Miniature micromachined quadrupole mass spectrometer array and method of making the same

The present invention provides a quadrupole mass spectrometer and an ion filter for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.

Chutjian, Ara↗

Miniature micromachined quadrupole mass spectrometer array and method of making the same

The present invention provides a quadrupole mass spectrometer and an ion filter, or pole array, for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.

Chutjian, Ara↗

Miniature micromachined quadrupole mass spectrometer array and method of making the same

The present invention provides a quadrupole mass spectrometer and an ion filter for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.

Chutjian, Ara↗

Miniature micromachined quadrupole mass spectrometer array and method of making the same

The present invention provides a quadrupole mass spectrometer and an ion filter, or pole array, for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.

Chutjian, Ara↗

Miniature micromachined quadrupole mass spectrometer array and method of making the same

The present invention provides a quadrupole mass spectrometer and an ion filter for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and aligrnent for use in a final quadrupole mass spectrometer device.

Chutjian, Ara↗

Miniature micromachined quadrupole mass spectrometer array and method of making the same

The present invention provides a quadrupole mass spectrometer and an ion filter, or pole array, for use in the quadrupole mass spectrometer. The ion filter includes a thin patterned layer including a two-dimensional array of poles forming one or more quadrupoles. The patterned layer design permits the use of very short poles and with a very dense spacing of the poles, so that the ion filter may be made very small. Also provided is a method for making the ion filter and the quadrupole mass spectrometer. The method involves forming the patterned layer of the ion filter in such a way that as the poles of the patterned layer are formed, they have the relative positioning and alignment for use in a final quadrupole mass spectrometer device.

Chutjian, Ara↗

Identification and Quantitative Measurements of Chemical Species by Mass Spectrometry

The development of a miniature gas chromatograph/mass spectrometer system for the measurement of chemical species of interest to combustion is described. The completed system is a fully-contained, automated instrument consisting of a sampling inlet, a small-scale gas chromatograph, a miniature, quadrupole mass spectrometer, vacuum pumps, and software. A pair of computer-driven valves controls the gas sampling and introduction to the chromatographic column. The column has a stainless steel exterior and a silica interior, and contains an adsorbent of that is used to separate organic species. The detection system is based on a quadrupole mass spectrometer consisting of a micropole array, electrometer, and a computer interface. The vacuum system has two miniature pumps to maintain the low pressure needed for the mass spectrometer. A laptop computer uses custom software to control the entire system and collect the data. In a laboratory demonstration, the system separated calibration mixtures containing 1000 ppm of alkanes and alkenes.

Zondlo, Mark A.↗

Development of a miniaturized gas chromatograph-mass spectrometer with a microbore capillary column and an array detector

A review is presented of the demonstration of a miniaturized focal plane mass spectrograph using a microbore capillary column with an array detector to measure multiple mass spectra from narrow and closely eluted gas chromatograph peaks. It is shown that the system possesses high sensitivity and a high speed of spectral mass measurements. The combination of the capillary column with the miniaturized mass spectrograph is uniquely suited for the development of a field-portable, high-performance system.

Sinha, Mahadeva P.↗

Miniaturized Ion and Neutral Mass Spectrometer for CubeSat Atmospheric Measurements

To increase the number of single point in-situ measurements of thermosphere and exosphere ion and neutral composition and density, miniaturized instrumentation is in high demand to take advantage of the increasing platform opportunities available in the smallsat/cubesat industry. The INMS (Ion-Neutral Mass Spectrometer) addresses this need by providing simultaneous measurements of both the neutral and ion environment, essentially providing two instruments in one compact model. The 1.3U volume, 570 gram, 1.8W nominal power INMS instrument makes implementation into cubesat designs (3U and above) practical and feasible. With high dynamic range (0.1-500eV), mass dynamic range of 1-40amu, sharp time resolution (0.1s), and mass resolution of MdM16, the INMS instrument addresses the atmospheric science needs that otherwise would have required larger more expensive instrumentation. INMS-v1 (version 1) launched on Exocube (CalPoly 3U cubesat) in 2015 and INMS-v2 (version 2) is scheduled to launch on Dellingr (GSFC 6U cubesat) in 2017. New versions of INMS are currently being developed to increase and add measurement capabilities, while maintaining its smallsat/cubesat form.

science↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗

Numerical Investigation of Ion Transport in the MOMA Ion Mass Spectrometer

The Mars Organic Molecule Analyzer (MOMA) is a miniature ion trap mass spectrometer designed for the upcoming ExoMars Rover mission. The spectrometer uses laser desorption to ionize a Martian soil sample within an instrument internal clean zone maintained at ambient Martian pressure. A high-speed aperture valve transiently opens to allow ionized constituents, along with the ambient gas, to enter a vacuum cavity containing a linear ion trap mass spectrometer. The ambient clean zone and the vacuum cavity are connected via a few centimeter long aperture valve ion guide tube. In this paper, we present results from a recently completed numerical investigation of ion transport from the ion source across the ion guide. Specifically, we focus on collisional coupling between ions and the neutral molecules flowing into the vacuum cavity. The simulation domain contains the ambient region, and we consider the variation in ion conductance with ambient pressure. We also analyze the impact of a fixed potential bias applied to the aperture valve. Simulations are performed with a two-dimensional axisymmetric PIC / DSMC code Starfish. Numerical results are compared to experimental data.

Breida, Lubos↗

Simulation of a Miniature, Low-Power Time-of-Flight Mass Spectrometer for In Situ Analysis of Planetary Atmospheres

We are implementing nano- and micro-technologies to develop a miniaturized electron impact ionization mass spectrometer for planetary science. Microfabrication technology is used to fabricate the ion and electron optics, and a carbon nanotube (CNT) cathode is used to generate the ionizing electron beam. Future NASA planetary science missions demand miniaturized, low power mass spectrometers that exhibit high resolution and sensitivity to search for evidence of past and present habitability on the surface and in the atmosphere of priority targets such as Mars, Titan, Enceladus, Venus, Europa, and short-period comets. Toward this objective, we are developing a miniature, high resolution reflectron time-of-flight mass spectrometer (Mini TOF-MS) that features a low-power CNT field emission electron impact ionization source and microfabricated ion optics and reflectron mass analyzer in a parallel-plate geometry that is scalable. Charged particle electrodynamic modeling (SIMION 8.0.4) is employed to guide the iterative design of electron and ion optic components and to characterize the overall performance of the Mini TOF-MS device via simulation. Miniature (less than 1000 cubic centimeters) TOF-MS designs (ion source, mass analyzer, detector only) demonstrate simulated mass resolutions greater than 600 at sensitivity levels on the order of 10(exp -3) cps/molecule N2/cc while consuming 1.3 W of power and are comparable to current spaceflight mass spectrometers. Higher performance designs have also been simulated and indicate mass resolutions approximately 1000, though at the expense of sensitivity and instrument volume.

King, Todd T.↗