Search NASA⌕ Search

SEARCH · Search NASA

Results for “miniature specimen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In situ sputter cleaning of thin film metal substrates for UHV-TEM corrosion studies.

A prerequisite for conducting valid corrosion experiments by in situ electron microscopy techniques is not only the achievement of UHV background pressure conditions at the site of the specimen but also the ability to clean the surface of the thin metal substrate specimen before initiation of the corrosive interaction. A miniaturized simple ion gun has been constructed for this purpose. The gun is small enough to be incorporated into an UHV electron microscope specimen chamber with hot stage in such a way as to permit bombardment of the substrate specimen while observing it by transmission electron microscopy TEM. It is shown that the ion beam generated is confined well enough to cause a sputtering removal of substrate material at a rate of approximately 5-10 A/min and to prevent the sputter deposition of contaminating material from the specimen holder.

Heinemann, K.↗

HFIR SiC Bowing Test Ready to Insert

This report describes the successful assembly of a High Flux Isotope Reactor (HFIR) irradiation experiment designed to assess radiation-induced lateral bowing of silicon carbide fiber–reinforced, silicon carbide matrix composite (SiC/SiC) components under a radial fast neutron flux gradient. Excessive bowing of a SiC/SiC channel box in a boiling water reactor could potentially interfere with control blade movements. Similar concerns exist for SiC/SiC fuel cladding in light water reactors. The experiment described herein will provide experimental validation of the structural response of a miniature SiC/SiC channel box and tube specimens with pressurized water reactor diameters during irradiation. The significant radial fast neutron flux gradients that exist in the permanent reflector of HFIR were characterized using detailed three-dimensional neutronic calculations. The three-dimensional displacement damage dose rate profile and the resulting volumetric swelling in SiC were used as inputs to structural analyses that predicted the deformation and stresses in the channel box specimen. The specimens were thoroughly characterized prior to irradiation using traditional dimensional inspection and surface profilometry so that these measurements can later be compared with similar measurements that will be made post-irradiation to determine radiation-induced deformations. Furthermore, fine engraving markers were inscribed along all outer surfaces of the specimen and mapped using a digital microscope and a three-dimensional stage. This technique allowed for accurate measurements of the marker spacings, which can be compared with similar measurements that will be made post-irradiation to provide local radiation-induced strain mapping. The experiment was successfully assembled and is scheduled for insertion during HFIR cycle 492, which is currently scheduled to run from May 25, 2021 to June 18, 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scanning Miniature Microscopes without Lenses

The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the nonpolarizing beam splitter were replaced by a polarizing one, then the specimen would be illuminated by s-polarized light. Upon reflection from the specimen, some of the s-polarized light would become p-polarized. Only the p-polarized light would contribute to the image on the CCD; in other words, the image would contain information on the polarization rotating characteristic of the specimen.

Wang, Yu↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Good Neighborhood for Cells: Bioreactor Demonstration System (BDS-05)

Good neighborhoods help you grow. As with a city, the lives of a cell are governed by its neighborhood connections Connections that do not work are implicated in a range of diseases. One of those connections - between prostate cancer and bone cells - will be studied on STS-107 using the Bioreactor Demonstration System (BDS-05). To improve the prospects for finding novel therapies, and to identify biomarkers that predict disease progression, scientists need tissue models that behave the same as metastatic or spreading cancer. This is one of several NASA-sponsored lines of cell science research that use the microgravity environment of orbit in an attempt to grow lifelike tissue models for health research. As cells replicate, they "self associate" to form a complex matrix of collagens, proteins, fibers, and other structures. This highly evolved microenvironment tells each cell who is next door, how it should grow arid into what shapes, and how to respond to bacteria, wounds, and other stimuli. Studying these mechanisms outside the body is difficult because cells do not easily self-associate outside a natural environment. Most cell cultures produce thin, flat specimens that offer limited insight into how cells work together. Ironically, growing cell cultures in the microgravity of space produces cell assemblies that more closely resemble what is found in bodies on Earth. NASA's Bioreactor comprises a miniature life support system and a rotating vessel containing cell specimens in a nutrient medium. Orbital BDS experiments that cultured colon and prostate cancers have been highly promising.

Chung, Leland W. K.↗

Miniature load cell instrumentation for finite deformation biaxial testing of elastomers

Accuracy of biaxial test equipment to examine the nonlinear mechanical behavior of thin sheet specimens of elastomeric materials has been hampered by lack of precise determination of the force distribution along the sides of the specimen. It has been necessary to use an effective width established by approximate means to obtain the stress from the overall force applied along the edges. To avoid this experimental difficulty, individual miniature proof-ring load cells utilizing semiconductor strain gages have been developed and applied to the support hooks for the thin sheet specimens. Typical results are shown for time-dependent stress distributions for all degrees of biaxiality. An accurate evaluation of the effective specimen width is now possible.

Arenz, R. J.↗

A miniature fatigue test machine

The objective is to enable the student to generate statistically sound fatigue data sets on wire specimens of varying diameter, microstructure, or material. The student can then assess the effect of these parameters of fatigue resistance. The student can also be exposed to ASTM techniques for fatigue data reduction and presentation. Experiments involving variable amplitude block loading are also easily conducted.

Tipton, Steven M.↗

Size effect in stainless steel thin wires under tension

Miniaturization of modern devices drives the exploration into how materials behave in small dimensions. However, the mechanical behaviors of micro-scale specimens under varied loading conditions are still challenging to characterize and predict. In this work, specimen size-dependent weakening effect was experimentally revealed in 316L stainless steel thin wires under tension with wire diameter decreasing from 200 μm down to 61 μm. The underlying mechanisms were primarily associated with surface grain softening and strain localization, which were largely dependent on the number of grains across wire diameter. Through an analog composite model with surface and interior grains that follows the Hall-Petch relation, the extent of surface grain softening was found to coincide with the flow stress reduction due to lack of boundary strengthening. Further using elasto-plastic self-consistent polycrystal modeling, the stress-strain behaviors of interior and surface grains were well described in analogy to those of bulk materials with similar-size grains and extremely large grains, respectively. Subsequently, the analog composite model well simulated the specimen size-dependent weakening effect under tension. This article provided more insights into the size effect exploration and proposed a practical model for describing size-dependent mechanical behaviors of small-scale materials to be applied to miniaturized devices.

316L stainless steel↗

Miniature Beryllium Split-Hopkinson Pressure Bars for Extending the Range of Achievable Strain-Rates

Conventional Split Hopkinson Pressure Bars (SHPB) or “Kolsky” bars are often used for determining the high-rate compressive yield and failure strength of materials. However, for experiments generating very high strain-rates (>10 3 /s) miniaturization of the setup is often required for minimizing the effects of elastic wave dispersion in order to enable the inference of decreasingly short loading events from the data. Miniature aluminum and steel bars are often sufficient for meeting these requirements. However, for high enough strain-rates, miniaturization of steel or aluminum Kolsky bars may require prohibitively small diameter bars and test specimens that could become inappropriate for inferring representative properties of materials with large grain size relative to the test specimen size. The use of a beryllium Kolsky bar setup is expected to enable high rates to be accessible with larger diameter bars/specimen combinations due to the inherent physical properties of beryllium, which are expected to minimize the effects of elastic wave dispersion. For this reason, a series of beryllium Kolsky bars have been developed, and, in this paper, the dispersion characteristics of these bars are measured and compare the data with those of similarly sized 7075-T6 aluminum and C350 maraging steel. The results, which agree well with the theory, show no appreciable frequency dependence of the elastic wavespeed in the data from the beryllium bars, demonstrating its advantage over aluminum and steel in application to Kolsky bars.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, February 2005

Topics discussed include: Instrumentation for Sensitive Gas Measurements; Apparatus for Testing Flat Specimens of Thermal Insulation; Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da; Miniature Laser Doppler Velocimeter for Measuring Wall Shear; Coherent Laser Instrument Would Measure Range and Velocity; Printed Microinductors for Flexible Substrates; Digital Receiver for Microwave Radiometry; Printed Antennas Made Reconfigurable by Use of MEMS Switches; Traffic-Light-Preemption Vehicle-Transponder Software Module; Intersection-Controller Software Module; Central-Monitor Software Module; Estimating Effects of Multipath Propagation on GPS Signals; Parallel Adaptive Mesh Refinement Library; Predicting Noise From Aircraft Turbine-Engine Combustors; Generating Animated Displays of Spacecraft Orbits; Diagnosis and Prognosis of Weapon Systems; Training Software in Artificial-Intelligence Computing Techniques; APGEN Version 5.0; Single-Command Approach and Instrument Placement by a Robot on a Target; Three-Dimensional Audio Client Library; Isogrid Membranes for Precise, Singly Curved Reflectors; Nickel-Tin Electrode Materials for Nonaqueous Li-Ion Cells; Photocatalytic Coats in Glass Drinking-Water Bottles; Fast Laser Shutters With Low Vibratory Disturbances; Series-Connected Buck Boost Regulators; Space Physics Data Facility Web Services; Split-Resonator, Integrated-Post Vibratory Microgyroscope; Blended Buffet-Load-Alleviation System for Fighter Airplane; Gifford-McMahon/Joule-Thomson Refrigerator Cools to 2.5 K; High-Temperature, High-Load-Capacity Radial Magnetic Bearing; Fabrication of Spherical Reflectors in Outer Space; Automated Rapid Prototyping of 3D Ceramic Parts; Tissue Engineering Using Transfected Growth-Factor Genes; Automation of Vapor-Diffusion Growth of Protein Crystals; Atom Skimmers and Atom Lasers Utilizing Them; Gears Based on Carbon Nanotubes; Patched Off-Axis Bending/Twisting Actuators for Thin Mirrors; and Improving Control in a Joule-Thomson Refrigerator.

Source record↗

Scanning Microscopes Using X Rays and Microchannels

Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the image sensor consists predominantly of radiation that was launched along the longitudinal direction of the microchannels. Therefore, most of the radiation arriving at each pixel on the sensor must have traveled along a straight line from a corresponding location on the specimen. Thus, there is a one-to-one mapping from a point on a specimen to a pixel in the image sensor, so that the output of the image sensor contains image information equivalent to that from a microscope.

Wang, Yu↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗

Advanced Material Studies for High Intensity Proton Production Targets and Windows

The titanium alloy Ti6Al4V is widely used in accelerator facilities as beam windows, which are exposed to high cycle compressive stress waves from intense pulsed proton beams. Such materials interacting with the beam are subject to various forms of radiation damage, which can adversely affect their endurance limit. However, no fatigue data is currently available for high energy proton irradiated titanium alloy. Due to limitations in proton irradiation facilities, only miniature flat samples can be used for irradiation. To address this issue, we have developed a custom-made bend fatigue tester at Fermilab specifically for testing proton irradiated titanium alloy. In this presentation, we report on the fatigue test results obtained from this custom-fatigue tester using a non-ASTM standard specimen design. We plan to validate these sparse fatigue data with ASTM standard samples using standard fatigue samples. Furthermore, we have modified another commercial bend fatigue tester to accommodate miniature samples, and discuss some inherent deficiencies of the commercial fatigue tester to test miniature samples. To overcome this issue, a new fixture design is presented, which enables satisfactory fatigue testing on miniature samples over long periods. Finally, we present an upgrade to the custom-fatigue tester, featuring this new fixture design.

43 PARTICLE ACCELERATORS↗

Advanced Material Studies for High Intensity Proton Production Targets and Windows

The titanium alloy Ti6Al4V is widely used in accelerator facilities as beam windows, which are exposed to high cycle compressive stress waves from intense pulsed proton beams. Such materials interacting with the beam are subject to various forms of radiation damage, which can adversely affect their endurance limit. However, no fatigue data is currently available for high energy proton irradiated titanium alloy. Due to limitations in proton irradiation facilities, only miniature flat samples can be used for irradiation. To address this issue, we have developed a custom-made bend fatigue tester at Fermilab specifically for testing proton irradiated titanium alloy. In this presentation, we report on the fatigue test results obtained from this custom-fatigue tester using a non-ASTM standard specimen design. We plan to validate these sparse fatigue data with ASTM standard samples using standard fatigue samples. Furthermore, we have modified another commercial bend fatigue tester to accommodate miniature samples, and discuss some inherent deficiencies of the commercial fatigue tester to test miniature samples. To overcome this issue, a new fixture design is presented, which enables satisfactory fatigue testing on miniature samples over long periods. Finally, we present an upgrade to the custom-fatigue tester, featuring this new fixture design.

43 PARTICLE ACCELERATORS↗

Blood Vessel Tension Tester

In the photo, a medical researcher is using a specially designed laboratory apparatus for measuring blood vessel tension. It was designed by Langley Research Center as a service to researchers of Norfolk General Hospital and Eastern Virginia Medical School, Norfolk, Virginia. The investigators are studying how vascular smooth muscle-muscle in the walls of blood vessels-reacts to various stimulants, such as coffee, tea, alcohol or drugs. They sought help from Langley Research Center in devising a method of measuring the tension in blood vessel segments subjected to various stimuli. The task was complicated by the extremely small size of the specimens to be tested, blood vessel "loops" resembling small rubber bands, some only half a millimeter in diameter. Langley's Instrumentation Development Section responded with a miniaturized system whose key components are a "micropositioner" for stretching a length of blood vessel and a strain gage for measuring the smooth muscle tension developed. The micropositioner is a two-pronged holder. The loop of Mood vessel is hooked over the prongs and it is stretched by increasing the distance between the prongs in minute increments, fractions of a millimeter. At each increase, the tension developed is carefully measured. In some experiments, the holder and specimen are lowered into the test tubes shown, which contain a saline solution simulating body fluid; the effect of the compound on developed tension is then measured. The device has functioned well and the investigators say it has saved several months research time.

Source record↗

Miniature Laboratory for Detecting Sparse Biomolecules

A miniature laboratory system has been proposed for use in the field to detect sparsely distributed biomolecules. By emphasizing concentration and sorting of specimens prior to detection, the underlying system concept would make it possible to attain high detection sensitivities without the need to develop ever more sensitive biosensors. The original purpose of the proposal is to aid the search for signs of life on a remote planet by enabling the detection of specimens as sparse as a few molecules or microbes in a large amount of soil, dust, rocks, water/ice, or other raw sample material. Some version of the system could prove useful on Earth for remote sensing of biological contamination, including agents of biological warfare. Processing in this system would begin with dissolution of the raw sample material in a sample-separation vessel. The solution in the vessel would contain floating microscopic magnetic beads coated with substances that could engage in chemical reactions with various target functional groups that are parts of target molecules. The chemical reactions would cause the targeted molecules to be captured on the surfaces of the beads. By use of a controlled magnetic field, the beads would be concentrated in a specified location in the vessel. Once the beads were thus concentrated, the rest of the solution would be discarded. This procedure would obviate the filtration steps and thereby also eliminate the filter-clogging difficulties of typical prior sample-concentration schemes. For ferrous dust/soil samples, the dissolution would be done first in a separate vessel before the solution is transferred to the microbead-containing vessel.

Lin, Ying↗

Miniature biaxial strain transducer

A reusable miniature strain transducer for use in the measurement of static or quasi-static, high level, biaxial strain on the surface of test specimens or structures was studied. Two cantilever arms, constructed by machining the material to appropriate flexibility, are self-aligning and constitute the transducing elements of the device. Used in conjunction with strain gages, the device enables testing beyond normal gage limits for high strains and number of load cycles. The device does not require conversion computations since the electrical output of the strain gages is directly proportional to the strain measured.

Hoffman, I. S.↗

Evaluation of the Effect of Microalloying on Cleavage of Monocrystalline NiAl Using a Miniaturized Disk-Bend Test

It was originally proposed to investigate the effect of microalloying on the ductility of monocrystalline NiAl. The idea was to deposit selected elements on oriented crystals of NiAl using magnetron sputtering, followed by annealing at high temperatures to produce the doped specimens. The project was terminated before that stage of the research was reached, but useful results needed for that study were obtained during the lifetime of the program. Those results are described in this report.

Ardell, Alan J.↗