Search NASA⌕ Search

SEARCH · Search NASA

Results for “miniature specimen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

51 records · Page 3

Advanced Material Studies for High Intensity Proton Production Targets and Windows

The titanium alloy Ti6Al4V is widely used in accelerator facilities as beam windows, which are exposed to high cycle compressive stress waves from intense pulsed proton beams. Such materials interacting with the beam are subject to various forms of radiation damage, which can adversely affect their endurance limit. However, no fatigue data is currently available for high energy proton irradiated titanium alloy. Due to limitations in proton irradiation facilities, only miniature flat samples can be used for irradiation. To address this issue, we have developed a custom-made bend fatigue tester at Fermilab specifically for testing proton irradiated titanium alloy. In this presentation, we report on the fatigue test results obtained from this custom-fatigue tester using a non-ASTM standard specimen design. We plan to validate these sparse fatigue data with ASTM standard samples using standard fatigue samples. Furthermore, we have modified another commercial bend fatigue tester to accommodate miniature samples, and discuss some inherent deficiencies of the commercial fatigue tester to test miniature samples. To overcome this issue, a new fixture design is presented, which enables satisfactory fatigue testing on miniature samples over long periods. Finally, we present an upgrade to the custom-fatigue tester, featuring this new fixture design.

43 PARTICLE ACCELERATORS↗

Advanced Material Studies for High Intensity Proton Production Targets and Windows

The titanium alloy Ti6Al4V is widely used in accelerator facilities as beam windows, which are exposed to high cycle compressive stress waves from intense pulsed proton beams. Such materials interacting with the beam are subject to various forms of radiation damage, which can adversely affect their endurance limit. However, no fatigue data is currently available for high energy proton irradiated titanium alloy. Due to limitations in proton irradiation facilities, only miniature flat samples can be used for irradiation. To address this issue, we have developed a custom-made bend fatigue tester at Fermilab specifically for testing proton irradiated titanium alloy. In this presentation, we report on the fatigue test results obtained from this custom-fatigue tester using a non-ASTM standard specimen design. We plan to validate these sparse fatigue data with ASTM standard samples using standard fatigue samples. Furthermore, we have modified another commercial bend fatigue tester to accommodate miniature samples, and discuss some inherent deficiencies of the commercial fatigue tester to test miniature samples. To overcome this issue, a new fixture design is presented, which enables satisfactory fatigue testing on miniature samples over long periods. Finally, we present an upgrade to the custom-fatigue tester, featuring this new fixture design.

43 PARTICLE ACCELERATORS↗

Irradiation creep measurement and microstructural analysis of chromium nitride–coated zirconium alloy using pressurized tubes

Environmental barrier coatings for Zr-based materials are currently under development to reduce oxidation and embrittlement in light-water reactors. Chromium nitride is one such candidate for this application, particularly as accident-tolerant fuel cladding. However, quantifying the impact of coatings on the irradiation-induced creep of zircaloy (Zry) is critical as this mechanism often exceeds thermal creep rates under light-water reactor operating conditions and can be a limiting design characteristic. Additionally, examining irradiation effects in the microstructure at the coating interface is key to understanding the compatibility of the material system. Here, to accelerate the experimental measurement of irradiation creep and microstructure evolution in CrN-Zry, compact, pressurized creep tubes were fabricated and irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Miniature, thin-walled rodlets fabricated from annealed Zr-Sn barstock were coated with CrN using physical vapor deposition (PVD) to nominal thicknesses of 4 and 8 μm. Coated and uncoated rodlet specimens were internally pressurized and welded, generating nominal circumferential hoop stresses of 0, 90, or 180 MPa under 300°C irradiation conditions. Twelve specimens were measured diametrically prior to irradiation using a low-cost, automated, contactless laser profilometer developed for this work. Specimens were irradiated in sealed capsules for one 25-day HFIR cycle, accumulating approximately 1.8 $\times$ 10 21 n/cm 2 fast fluence (E n > 10 MeV). The irradiated samples were retrieved and remeasured using the same profilometry system in a shielded hot cell facility. Irradiation creep between specimens was compared using standard statistical tests and showed that both thicknesses of CrN coating had a negligible effect on the irradiation creep strain of the Zry material. Microstructure characterization of pre- and post-irradiated CrN-Zry specimens showed minimal changes due to irradiation but did show a substantial O-rich region at the Zry-CrN interface.

36 MATERIALS SCIENCE↗

Additive manufacturing process parameter determination for a new Fe-C-Cu alloy

As a potential replacement for stainless steel alloys commonly used to print parts with laser powder bed fusion, a new Cu precipitation strengthened ferrous alloy, with composition Fe-0.2C-6Cu (wt%), was recently developed. This material is Co- and Ni-free, printable, has mechanical properties comparable to that of high strength stainless steels (approximately 1300 MPa UTS), and is cost-advantaged relative to existing low-alloy steels for additive manufacturing of parts with complex shapes. To gain traction for broader application, optimal laser powder bed fusion (LPBF) processing conditions to produce nearly defect-free parts without compromising mechanical strength are needed. Here, an optimal processing window based upon laser speeds that achieve minimal porosity was quantified via comparisons of measured melt pool penetration, scan speeds, printed material density and laser beam energy density on a commercial LPBF unit operating at 350 W, 80 μm hatch spacing, and 50 μm layer thickness based upon optimal parameters for 17-4PH. Furthermore, the window is 300 to 500 mm/s to achieve >99.8 % dense Fe-0.2C-6Cu (wt%) specimens. Other defects such as burning, spatter, and lack of fusion were also avoided in this window. The window was validated with in-situ synchrotron X-ray imaging that enabled visualization of the vapor cavity, melting, and solidification during a single laser track scan on a miniature powder bed sample. In addition, in-situ infrared imaging provided temperature fields, cooling rate and solidification range, and confirmed minimal printing defects and spatter within the processing window.

36 MATERIALS SCIENCE↗

AMMT FY23 HFIR Irradiation Test Matrix – Supported by the Design of a Miniature Bend Bar Irradiation Vehicle

With the continued advancement of additive manufacturing (AM) techniques, interest has grown in the development and qualification of steels produced via these methods for use in the structural components of advanced nuclear reactors. Therefore, it is crucial that the properties of these materials such as the tensile strength and fracture toughness be investigated following neutron irradiation to support their use in industry. To that end, a test plan to irradiate several tensile and bend bar specimens in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory was proposed, along with the development of a new “MINBEN” capsule design that features MBS-1 bend bar specimens that have a larger cross-sectional area than those of previous designs, which allows for higher temperature out-of-pile testing. The specimens include AM 316H stainless steel with wrought 316H and A709 stainless steels for reference, and they will be irradiated at 2 dpa and 10 dpa—corresponding to roughly 1 and 5 cycles at the HFIR midplane—at temperatures of 400°C and 600°C. The MINBEN design was found to be capable of providing specimen test plane average temperatures in the range of 220–660°C for six specimens, with a min-max spread in this temperature of ~40°C and a 95% confidence interval of ~24°C. This analysis shows that the capsule provides an effective vehicle for gathering needed high-temperature fracture toughness data.

36 MATERIALS SCIENCE↗

A Miniaturized, High-Bandwidth Optical Fiber Fabry–Perot Cavity Vibration Sensor Demonstrated up to 800 °C

A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.

Birri, Anthony [Oak Ridge National Laboratory (ORN↗

ROADRUNNER MiniFuel Experiment: Irradiation Target Design and Sample Characterization

High-density uranium nitride (UN) is a fuel candidate for several advanced nuclear reactor designs currently under development. Because there are limited UN performance data relative to fuel fabrication impurity and density variation, an irradiation campaign has been developed as part of a collaborative effort among the University of Texas at San Antonio (UTSA), Westinghouse Electric Company, Oak Ridge National Laboratory (ORNL), and Los Alamos National Laboratory (LANL) under the Nuclear Science User Facilities program. This project, entitled ROADRUNNER, or Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments, aimsto support UN fuel qualification for advanced reactors by investigating the impact of density and impurity variations on UN performance as a function of irradiation temperature and burnup. The MiniFuel experiment vehicle developed by ORNL, which leverages the High Flux Isotope Reactor, was selected to perform this accelerated separate-effects irradiation testing. The experiment test matrix consists of six MiniFuel targets containing miniature UN fuel disks, and targets three distinct burnup levels (37.5, 60, and 75 MWd/kg U) and three distinct temperatures (600, 900, and 1200°C). Neutronics and thermal analyses were performed to determine the experimental parameters needed to meet the desired irradiation conditions and to predict the experiment components temperatures. UN pellets were fabricated at LANL with tightly controlled parameters to produce specimens with three distinct densities and three levels of carbon content. The pellets were then thinned down by UTSA to the experiment-required thickness. The pre-characterization of the specimens includes density measurements, carbon and oxygen contents, microstructure analysis, and x-ray computed tomography. The selected specimens will be assembled into the MiniFuel experiment, and the first ROADRUNNER MiniFuel targets are intended for HFIR insertion during the Fall of 2024. After irradiation, the targets will be shipped to ORNL’s hot cell facility for disassembly. The post-irradiation examination on the fuel specimens includes fission gas release measurements, visual inspection, fuel swelling measurements, gamma spectroscopy, and microstructure analysis. The data collected post-irradiation will be used to develop fuel performance models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UCO TRISO Minifuel FY23 NSUF-Kairos Power Post-Irradiation Examination Status Report

Irradiation of miniature tristructural isotropic (TRISO)–coated particle fuel compacts at high-power particle was performed in the Oak Ridge National Laboratory’s (ORNL’s) High Flux Isotope Reactor (HFIR) using the MiniFuel irradiation capability. Each compact comprised 20 TRISO particles with a low-enriched uranium carbide uranium oxide (UCO), natural UCO, or low-enriched UO 2 kernel within a graphitic matrix. After irradiation, the MiniFuel targets and subcapsules were disassembled to recover the irradiated fuel specimens and pursue post-irradiation examination (PIE) to inform Kairos Power on the fuel specimen performance. This report describes the PIE results collected to date, including dilatometry on the passive thermometry to confirm the irradiation temperature, fission gas release measurements, and gamma counting. This work was funded by the Nuclear Science User Facilities program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Entropy Alloy R&D for Accelerator Beam Window Applications

High-Entropy Alloys are a class of novel material that can offer improved resistance to beam-induced radiation damage and thermal shock. Development of these new alloys to serve as beam windows in multi-megawatt accelerator target applications is ongoing at Fermilab. Currently we are investigating AlCoCrMnTiV alloy systems of 4-6 components for service as beam windows; these compositions are predicted by CALPHAD simulation to have a low density and single-phase BCC crystal structure. The microstructures of these systems are being studied by electron microscopy techniques such as energy dispersive X-ray spectroscopy (EDS) to determine elemental homogeneity and composition, electron backscatter diffraction (EBSD) to quantify grain structure and orientation, and transmission electron microscopy (TEM) to observe defect structures and precipitate formation; nanoindentation is used to probe microstructural mechanical properties. Initial bulk property characterization utilizes differential scanning calorimetry to quantify specific heat capacity (cp), dilatometry to determine the coefficient of thermal expansion (CTE), and time-domain thermoreflectance (TDTR) to measure thermal conductivity (K). A miniature tensile testing apparatus is also being developed to test tensile properties. Post-irradiation examination is currently ongoing for several of these compositions that have been irradiated by low-energy ions to damage levels and at a temperature relevant to beam window applications at future next-generation accelerator facilities. This talk will briefly describe the alloy design and synthesis before going into more depth covering microstructural pre-characterization, and post-irradiation examination results from low-energy ion irradiated specimens. This will be followed by the plans for alloy down selection and future prototypic proton irradiations.

43 PARTICLE ACCELERATORS↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ SEM High Strain Rate Testing of Large Diameter Micropillars Followed by TEM and EBSD Postmortem Analysis

Background Dislocation dynamic simulations are intended as a tool to understand and predict the mechanical behavior of metallic materials, but its prediction has never been directly verified by experiments due to differences in specimen strain rate and size. Objective In this work, a comprehensive experimental framework is proposed to attempt direct comparison between experiments and discrete dislocation dynamics (DDD) modelling. Methods By integrating high-throughput sample fabrication and a customized testing apparatus, the sample size and strain rate typically employed in DDD simulations are explored experimentally. Constitutive properties such as stress-strain response are measured, and microstructural information is obtained from transmission electron microscopy (TEM) imaging, electron backscatter diffraction (EBSD), and TEM-based orientation mapping. Results Magnesium and copper were selected, as case studies, to demonstrate the newly developed experimental procedure. Measured stress-strain responses for Mg are consistent with those obtained with a miniaturized Hopkison bar experiments. Furthermore, by exploiting the validated workflow, the effect of strain rate on micropillar heterogeneous deformation and associated dislocation plasticity were revealed. Conclusion The work establishes a methodology for the systematic study of not only metals but also other materials and structures at the microscale and high strain rates.

42 ENGINEERING↗

Residual Stress Measurements in Extreme Environments for Hazardous, Layered Specimens

In nuclear fuel plates of low-enriched U-10Mo (LEU) clad with aluminum by hot isostatic pressing (HIP), post-irradiation stresses arising during reactor shutdown are a major concern for safe reactor operations. Measurement of those residual stresses has not previously been possible because the high radioactivity of the plates requires handling only by remote manipulation in a hot cell. The incremental slitting method for measuring through-thickness stress profiles was modified, and a system for automated, remote operation was built and tested. Experimental modifications consisted of replacing electric-discharge machining (EDM) with a small end mill and strain-gauge measurements with cantilever displacement measurements. The inverse method used to calculate stresses was the pulse-regularization method modified to allow discontinuities across material interfaces. The new system was validated by comparing with conventional slitting on a depleted U-10Mo (DU) fuel plate. The new system was applied to two measurements each on six as-fabricated (pre-irradiation) LEU miniature fuel plates. Variations between the measurements at two locations in the same plate were strongly correlated with measured geometrical heterogeneity in the plate—a tilt in the fuel foil. Compressive stresses in the U-10Mo were shown to increase from 20 to 250 MPa as the ratio of aluminum thickness to U-10Mo thickness increased causing increased constraint during cooling. Faster cooling rates during processing also increased stress magnitudes. The measurements trends agreed with data in the literature from similar plates made with DU, which further validates the method. Because other methods are impractical in a hot cell, the modified slitting method is now poised for the first measurements of post-irradiation stresses.

36 MATERIALS SCIENCE↗

Fabrication and Testing of Two Passively Actuated Creep-Fatigue Surveillance Test Articles

This report describes the fabrication, testing, and analysis of two families of passively-actuated creep-fatigue test articles. These test articles induce cyclic mechanical load in a test section actuated solely through a mismatch in the thermal expansion coefficient of two materials and driven by a change in the specimen temperature. Test articles of this type could provide material degradation data for a materials surveillance program in future operating molten salt reactors, where variations in the reactor temperature caused by normal or upset cycles would provide the temperature change in the sample. The purpose of the current experimental campaign is to demonstrate the feasibility of fabricating realistically-sized test articles, test the articles under repeated thermal cycling to assess their robustness, particularly the reliability of the bimetallic welds, and collect strain data from instrumented samples to validate the methods used to size the test articles to match key features of the mechanical response of operating reactor components. The thermal cycling tests are ongoing but the test data to date suggests the current test article design is viable, robust, and can be successfully designed to match a target mechanical response. Finally, the report describes preliminary work on welding refractory alloys to 316H stainless steel. Replacing the test article driver material, currently Alloy 617, with a refractory would increase the coefficient of thermal expansion mismatch and support further miniaturization of the test articles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗