Search NASA⌕ Search

SEARCH · Search NASA

Results for “minimum sample volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Survey of Technologies to Meet PAG limits for Detection of Cesium-137 in Water

The goal of this report is to evaluate the process of adding a sorbent to the sampling process to preconcentrate Cs-137 and then analyze the sorbent to provide a rapid assessment of results to guide decisions on drinking water sources and the protection of the public. Multiple unit design variables were considered: sample configuration/geometry, sorbent efficiency, sample volume. Model simulations demonstrated through these unit design efficiencies that 10 L of sample volume processed through a sorbent provides nearly two orders of magnitude improvement in sample counting time to provide results to a decision maker than the current process. Over 60 publications and reports concerning Cs-137 and sorbents were evaluated. The key attributes were readiness of sorbent to be deployed in a mobile laboratory environment, and minimum sample preparation and conditioning. Examples of sorbents not considered further included nanomaterials, which have not been evaluated at a commercial scale and are limited in availability. The recommended sorbents for further consideration include: ferrocyanide salts, zeolite, and chemically modified granular activated carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Signal Processing and Calibration of Continuous-Wave Focused CO2 Doppler Lidars for Atmospheric Backscatter Measurement

Two continuous-wave(CW)focused C02 Doppler lidars (9.1 and 10.6 micrometers) were developed for airborne in situ aerosol backscatter measurements. The complex path of reliably calibrating these systems, with different signal processors, for accurate derivation of atmospheric backscatter coefficients is documented. Lidar calibration for absolute backscatter measurement for both lidars is based on range response over the lidar sample volume, not solely at focus. Both lidars were calibrated with a new technique using well-characterized aerosols as radiometric standard targets and related to conventional hard-target calibration. A digital signal processor (DSP), a surface acoustic and spectrum analyzer and manually tuned spectrum analyzer signal analyzers were used. The DSP signals were analyzed with an innovative method of correcting for systematic noise fluctuation; the noise statistics exhibit the chi-square distribution predicted by theory. System parametric studies and detailed calibration improved the accuracy of conversion from the measured signal-to-noise ratio to absolute backscatter. The minimum backscatter sensitivity is approximately 3 x 10(exp -12)/m/sr at 9.1 micrometers and approximately 9 x 10(exp -12)/m/sr at 10.6 micrometers. Sample measurements are shown for a flight over the remote Pacific Ocean in 1990 as part of the NASA Global Backscatter Experiment (GLOBE) survey missions, the first time to our knowledge that 9.1-10.6 micrometer lidar intercomparisons were made. Measurements at 9.1 micrometers, a potential wavelength for space-based lidar remote-sensing applications, are to our knowledge the first based on the rare isotope C-12 O(2)-18 gas.

Rothermel, Jeffry↗

Mars Sample Return Landed with Red Dragon

A Mars Sample Return (MSR) mission is the highest priority science mission for the next decade as recommended by the recent Decadal Survey of Planetary Science. However, an affordable program to carry this out has not been defined. This paper describes a study that examined use of emerging commercial capabilities to land the sample return elements, with the goal of reducing mission cost. A team at NASA Ames examined the feasibility of the following scenario for MSR: A Falcon Heavy launcher injects a SpaceX Dragon crew capsule and trunk onto a Trans Mars Injection trajectory. The capsule is modified to carry all the hardware needed to return samples collected on Mars including a Mars Ascent Vehicle (MAV), an Earth Return Vehicle (ERV) and Sample Collection and Storage hardware. The Dragon descends to land on the surface of Mars using SuperSonic Retro Propulsion (SSRP) as described by Braun and Manning [IEEEAC paper 0076, 2005]. Samples are acquired and deliverd to the MAV by a prelanded asset, possibly the proposed 2020 rover. After samples are obtained and stored in the ERV, the MAV launches the sample-containing ERV from the surface of Mars. We examined cases where the ERV is delivered to either low Mars orbit (LMO), C3 = 0 (Mars escape), or an intermediate energy state. The ERV then provides the rest of the energy (delta V) required to perform trans-Earth injection (TEI), cruise, and insertion into a Moon-trailing Earth Orbit (MTEO). A later mission, possibly a crewed Dragon launched by a Falcon Heavy (not part of the current study) retrieves the sample container, packages the sample, and performs a controlled Earth re-entry to prevent Mars materials from accidentally contaminating Earth. The key analysis methods used in the study employed a set of parametric mass estimating relationships (MERs) and standard aerospace analysis software codes modified for the MAV class of launch vehicle to determine the range of performance parameters that produced converged spacecraft designs capable of meeting mission requirements. Subsystems modeled in this study included structures, power system, propulsion system, nose fairing, thermal insulation, actuation devices, and GN&C. Best practice application of loads and design margins for all resources were used. Both storable and cryogenic propellant systems were examined. The landed mass and lander capsule size provide boundary conditions for the MAV design and packaging. We estimated the maximum mass the Dragon capsule is capable of landing. This and the volume capability to store the MAV was deduced from publically available data from SpaceX as well as our own engineering and aerodynamic estimates. Minimum gross-liftoff mass (GLOM) for the MAV were obtained for configurations that used pump-fed storable bi-propellant rocket engines for both the MAV and the ERV stage. The GLOM required fits within our internal estimate of the mass that Dragon can land at low elevation/optimal seasons on Mars. Based on the analysis, we show that a single Mars launch sample return mission is feasible using current commercial capabilities to deliver the return spacecraft assets.

Mars Ascent Vehicle (MAV)↗

Shield weight optimization using Monte Carlo transport calculations

Outlines are given of the theory used in FASTER-3 Monte Carlo computer program for the transport of neutrons and gamma rays in complex geometries. The code has the additional capability of calculating the minimum weight layered unit shield configuration which will meet a specified dose rate constraint. It includes the treatment of geometric regions bounded by quadratic and quardric surfaces with multiple radiation sources which have a specified space, angle, and energy dependence. The program calculates, using importance sampling, the resulting number and energy fluxes at specified point, surface, and volume detectors. Results are presented for sample problems involving primary neutron and both primary and secondary photon transport in a spherical reactor shield configuration. These results include the optimization of the shield configuration.

Jordan, T. M.↗

Advances in Resin Management Using 3R-Scan - 20154

The most important factor underlying optimal waste management is developing a clear picture of the radioactivity content of the waste and its impact on waste disposal cost. For over 35 years since the publishing of 10CFR61, waste characterization has relied on sampling the final waste product after formation. In the days following 10CFR61, the cost of final disposal was marginal with only a small impact on the overall costs. Constraints were added by provisions of the Low Level Waste Policy Act of 1985 leading to increasingly limited access to those disposal sites that remained available. In addition, Nuclear Regulatory Commission (NRC) pressure promoting waste volume reduction led to disposal costs inevitably rising. Despite this, characterization practices in monitoring of waste generation for activity content still center on the same dated processes. This results in a disposal classification on the basis of endpoint sampling without consideration of the homogeneity of the waste mixture. It can also disregard consideration of the representativeness of the single or small sample base. As a minimum effort, a formalized sampling program of a fixed grouping of waste streams can be implemented that could account for more than 95% of all of the activity carried in solid waste products. The sample results for each radionuclide could then be trended as time passes to develop reasonable scaling factors for difficult to measure radionuclides. This process, identified in NRC guidance, has been rigorously followed by a relatively small number of facilities. The trended scaling factors serve to improve accuracy by identifying anomalous results that could otherwise go undetected. Direct monitoring of the accumulation of activity in process streams generating solid radwaste, including demineralizers and filter streams, is a more precise approach. Nearly all of these streams are monitored by plant chemistry on a regular schedule to maintain water quality. This paper discusses viable options for developing the basis for characterization through process monitoring of the accumulation of activity at the point of generation. Special focus is on resin bed tracking and how process knowledge of these streams can be brought together to form a consistent and precise solid waste radioactivity inventory. Some of the specific points covered in this paper include the merger of the fission product release computer program, 3R-STAT, with the radwaste sample analysis computer program, SCAN4 to create 3R-SCAN, the importance of individual waste stream influences on the overall source term, and the use of historic sample data to develop scaling factors using an automated process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Results of an exploration of the relationship between ultrasonic attenuation and fatigue survivability of graphite fiber epoxy composites fabricated under different cure conditions are reported. A total of 9 27 x 40 cm eight-ply graphite epoxy laminated specimens were formed, and fatigue tests were run on five partial samples at 73.5 N varying at 30 Hz, with tests ending at a 1.27 cm deflection. A pulsed oscillator generated sinusoidal waves and transducers recorded the passage of the ultrasonic waves for display on oscilloscopes. Cure pressures ranged from 0.52-0.85 MPa and cure temperatures were in the 150-200 C interval. Ultrasonic through-transmission at 4 MHz was performed prior to and during fatigue testing. The minimum void volume fraction occurred at 175 C and 0.86 MPa. The flexural stiffness decreased with the number of fatigue cycles past 10,000, when the attenuation also increased. Correlations were found between the 4.0 MHz signal attenuation and the void volume fraction, and between the number of fatigue cycles to failure and the 4.0 MHz signal attenuation.

Williams, J. H., Jr.↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Top Loading Helium Cryostat Integrated with High-Pressure Cell with Fast Remote Pressure Control (Final Report for SBIR Phase 1)

A large number of physical phenomena, such as superconductivity and quantum critical phenomena, often appear only at very low temperatures below 5 K. There is an immense interest to investigate these phenomena at high pressure as a means of tuning interatomic distances, and thus the interaction parameters controlling these phenomena, in a continuous and controlled fashion. The current P-T condition for neutron scattering experiments are limited to either relatively low pressures of about 2 GPa at temperatures below 5 K, or to relatively high temperatures at pressures or tens of GPa. The purpose of this research is to develop neutron sample environment instrumentation for reaching 10-20 GPa at 1-2K with rapid and reliable online pressure and temperature control (i.e. without having to interrupt the experiment). The ultimate goal of the project is to design an integrated fast-cooling low-temperature sample environment cryogenic system compatible with state of the art neutron diamond anvil cells suitable for single-crystal neutron scattering experiments for temperatures down to 2K and pressures of several tens of GPa. The integrated system will consist of top-loading Helium flow cryostat with in-situ sample alignment mechanisms, large-volume diamond anvil cells (DAC) made from novel superalloy Pascalloy and optimized for fast cooling and heating, and a compact remote pressure control mechanism for the DAC based on a novel concept of inflatable bellows integrated with a lever-arm based force amplifier. In Phase I, we have designed, manufactured, and tested prototypes of the novel compact force-amplified pneumatic pressure control mechanism for Neutron Diamond Anvil Cell (nDAC), which allows to use pneumatic bellows system for smooth remote pressure control in the nDAC inside a top-loading cryostat with bore size of 70 mm or larger. This allows significant minimum temperature decrease in remotely controlled nDAC from 5-10 K down to 2 K. We also studied mechanical properties of a novel non-magnetic superalloy Pascalloy with different heat-treatment conditions and preliminary results indicate that up to date this is probably the strongest and most suitable material for making more compact and lightweight cryogenic nDACs for neuron scattering experiments at extreme conditions, allowing much faster cooling and heating. Potential applications: The new developments will allow to create a wide range of compact Diamond Anvil Cells for neutron diffraction which can reach several tens of GPA pressure at 2-4 K while preserving accurate remote pressure control capabilities. The new concepts can be used for developing sample environment instrumentation outside the neutron scattering field. The new development have very strong potential for expanding experimental capabilities in materials sciences and have high commercialization potential. The proposed new cryogenic high-pressure system or any of its individual components will be in high demand not only in neutron scattering facilities, but also at synchrotron beamlines and other high-pressure research facilities around the world.

36 MATERIALS SCIENCE↗

Mafic explosive volcanism at Llaima Volcano: 3D x-ray microtomography reconstruction of pyroclasts to constrain shallow conduit processes

Abstract Mafic volcanic activity is dominated by effusive to mildly explosive eruptions. Plinian and ignimbrite-forming mafic eruptions, while rare, are also possible; however, the conditions that promote such explosivity are still being explored. Eruption style is determined by the ability of gas to escape as magma ascends, which tends to be easier in low-viscosity, mafic magmas. If magma permeability is sufficiently high to reduce bubble overpressure during ascent, volatiles may escape from the magma, inhibiting violent explosive activity. In contrast, if the permeability is sufficiently low to retain the gas phase within the magma during ascent, bubble overpressure may drive magma fragmentation. Rapid ascent may induce disequilibrium crystallization, increasing viscosity and affecting the bubble network with consequences for permeability, and hence, explosivity. To explore the conditions that promote strongly explosive mafic volcanism, we combine microlite textural analyses with synchrotron x-ray computed microtomography of 10 pyroclasts from the 12.6 ka mafic Curacautín Ignimbrite (Llaima Volcano, Chile). We quantify microlite crystal size distributions (CSD), microlite number densities, porosity, bubble interconnectivity, bubble number density, and geometrical properties of the porous media to investigate the role of magma degassing processes at mafic explosive eruptions. We use an analytical technique to estimate permeability and tortuosity by combing the Kozeny-Carman relationship, tortuosity factor, and pyroclast vesicle textures. The groundmass of our samples is composed of up to 44% plagioclase microlites, > 85% of which are < 10 µm in length. In addition, we identify two populations of vesicles in our samples: (1) a convoluted interconnected vesicle network produced by extensive coalescence of smaller vesicles (> 99% of pore volume), and (2) a population of very small and completely isolated vesicles (< 1% of porosity). Computed permeability ranges from 3.0 × 10 −13 to 6.3 × 10 −12 m 2 , which are lower than the similarly explosive mafic eruptions of Tarawera (1886; New Zealand) and Etna (112 BC; Italy). The combination of our CSDs, microlite number densities, and 3D vesicle textures evidence rapid ascent that induced high disequilibrium conditions, promoting rapid syn-eruptive crystallization of microlites within the shallow conduit. We interpret that microlite crystallization increased viscosity while simultaneously forcing bubbles to deform as they grew together, resulting in the permeable by highly tortuous network of vesicles. Using the bubble number densities for the isolated vesicles (0.1-3 −3 × 10 4 bubbles per mm 3 ), we obtain a minimum average decompression rate of 1.4 MPa/s. Despite the textural evidence that the Curacautín magma reached the percolation threshold, we propose that rapid ascent suppressed outgassing and increased bubble overpressures, leading to explosive fragmentation. Further, using the porosity and permeability of our samples, we estimated that a bubble overpressure > 5 MPa could have been sufficient to fragment the Curacautín magma. Other mafic explosive eruptions report similar disequilibrium conditions induced by rapid ascent rate, implying that syn-eruptive disequilibrium conditions may control the explosivity of mafic eruptions more generally.

Valdivia, Pedro↗

Absorption coefficients for the 6190-A CH4 band between 290 and 100 K with application to Uranus' atmosphere

A novel laser intracavity photoacoustic spectroscopy method allowing high sample control accuracy due to the small sample volume required has been used to obtain absorption coefficients for the CH4 6190 A band as a function of temperature, from 290 to 100 K. The peak absorption coefficient is found to increase from 0.6 to 1.0/cm, and to be accompanied by significant band shape changes. When used to further constrain the Baines and Bergstrahl (1986) standard model of the Uranus atmosphere, the low-temperature data yield an excellent fit to the bandshape near the 6190 A band's minimum.

Smith, Wm. Hayden↗

Liquid hydrogen turbopump rapid start program

This program was to analyze, test, and evaluate methods of achieving rapid-start of a liquid hydrogen feed system (inlet duct and turbopump) using a minimum of thermal preconditioning time and propellant. The program was divided into four tasks. Task 1 includes analytical studies of the testing conducted in the other three tasks. Task 2 describes the results from laboratory testing of coating samples and the successful adherence of a KX-635 coating to the internal surfaces of the feed system tested in Task 4. Task 3 presents results of testing an uncoated feed system. Tank pressure was varied to determine the effect of flowrate on preconditioning. The discharge volume and the discharge pressure which initiates opening of the discharge valve were varied to determine the effect on deadhead (no through-flow) start transients. Task 4 describes results of testing a similar, internally coated feed system and illustrates the savings in preconditioning time and propellant resulting from the coatings.

Wong, G. S.↗

How Much Blue Carbon do Hudson Estuary Marshes Sequester? A Full-Depth Carbon Stock Estimation of Iona Marsh, Lower Hudson, NY

Tidal marshes function as a key ecosystem, by serving as nurseries, improving water quality, protecting biodiversity, preventing erosion of coastlines, and preserving archives of paleoclimate and paleoecology. In the last few decades, researchers have come to appreciate coastal marshes’ carbon sequestration function. However, full peat depth is required for estimating the true carbon content of marshes, and very little research has been done to discover the full peat depth along coastlines. We selected Iona Marsh (73°58’44.972”W, 41°18’6.366”N), situated adjacent to Bear Mountain Park and part of the National Estuarine Research Reserve, to document the belowground storage of blue carbon. In order to calculate marsh volume, three full-depth transects were performed from 2020 to 2022, two from east to west in different regions of the marsh, and one from north to south at a minimum of 10 m intervals. We found that marsh depth ranged from 5.1 m to 13.2 m. We calculated marsh volume from the full peat depth and marsh area, obtained through the National Wetlands Inventory database, by applying the average marsh depth over its entire surface area. In order to calculate carbon content, we extracted a 9m sediment core and used loss-on-ignition (LOI) to determine organic matter, then estimate carbon content as half of the organic matter. We used 198 LOI samples to calculate the carbon, which formed at this site over 6000 years ago. We intend to apply this methodology framework to other marshes in the Hudson region. Because many previous carbon stock estimates only account for the top 1 m of peat, the role of these ecosystems in carbon sequestration is significantly underestimated. By determining the full-depth carbon stock of these marshes, we hope to emphasize the value of marshes to the community, beyond what is traditionally recognized, particularly in light of sea level rise and the vulnerability of marshes to erosion.

Tidal marshes↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)↗

Benchmarking image processing techniques for porosity measurement in polymer additive manufacturing: Review and experimental analysis

An image processing workflow is proposed for porosity measurement in polymer additive manufacturing. Various techniques, including global and local thresholding, region growing, and K-means clustering, were applied to microscopic images of carbon fiber reinforced acrylonitrile butadiene styrene (CF-ABS) and benchmarked for their ability to accurately measure porosity. Global methods included Otsu, minimum error, iterative, and entropy-based thresholding, while local methods included Niblack, Bernsen, Sauvola, and Bradley-Roth algorithms. Artificial uneven illumination was introduced to test local adaptive thresholds. Results showed significant differences in porosity values across methods. Otsu, region growing, and K-means clustering excelled under uniform illumination, while Sauvola and Bradley-Roth performed better with uneven illumination. Comparison with X-ray computed tomography (XCT) revealed slightly lower porosity values (2.55 %) than optimized methods (2.73–2.79 %) due to XCT's lower resolution excluding smaller pores. While XCT offers finer pore detection, it limits sample volume and underestimates porosity due to spatial variation. Validation using artificial grayscale images with 5 % porosity confirmed that Otsu, Bradley-Roth, region growing, and Sauvola algorithms produced accurate results. Although tested on a single material system, these methods can be adapted to others with optimization. In conclusion, given XCT's high computational and time costs, this study highlights suitable image processing techniques as cost-effective alternatives for porosity analysis in polymer composites.

Additive manufacturing↗

Estimation of Rain Intensity Spectra over the Continental US Using Ground Radar-Gauge Measurements

A high-resolution surface rainfall product is used to estimate rain characteristics over the continental US as a function of rain intensity. By defining each data at 4-km horizontal resolutions and 1-h temporal resolutions as an individual precipitating/nonprecipitating sample, statistics of rain occurrence and rain volume including their geographical and seasonal variations are documented. Quantitative estimations are also conducted to evaluate the impact of missing light rain events due to satellite sensors' detection capabilities. It is found that statistics of rain characteristics have large seasonal and geographical variations across the continental US. Although heavy rain events (> 10 mm/hr.) only occupy 2.6% of total rain occurrence, they may contribute to 27% of total rain volume. Light rain events (< 1.0 mm/hr.), occurring much more frequently (65%) than heavy rain events, can also make important contributions (15%) to the total rain volume. For minimum detectable rain rates setting at 0.5 and 0.2 mm/hr which are close to sensitivities of the current and future space-borne precipitation radars, there are about 43% and 11% of total rain occurrence below these thresholds, and they respectively represent 7% and 0.8% of total rain volume. For passive microwave sensors with their rain pixel sizes ranging from 14 to 16 km and the minimum detectable rain rates around 1 mm/hr., the missed light rain events may account for 70% of train occurrence and 16% of rain volume. Statistics of rain characteristics are also examined on domains with different temporal and spatial resolutions. Current issues in estimates of rain characteristics from satellite measurements and model outputs are discussed.

Lin, Xin↗

USAF shale oil program status

The test and evaluation program on shale derived fuel being conducted by the Air Force is intended to accomplish the minimum amount of testing necessary to assure both the safe use of shale oil derived turbine fuels in operational USAF aircraft and its compatibility with USAF handling systems. This program, which was designed to take advantage of existing R&D testing programs, began in 1981. However, due to a problem in acquiring the necessary fuel, the testing program was suspended until July 1983 when an additional sample of shale derived fuel was received. Tentatively, the Air Force is planning to make three relatively minor revisions to the procurement specifications requirements for the production shale derived fuel. These are: (1) Aromatic Contest (min) - 9% (by volume); (2) Nitrogen (max - 20 ppm by weight); and (3) Antioxidants - 9.1 g/100 gal (U.S.)

Delaney, C. L.↗