Search NASA⌕ Search

SEARCH · Search NASA

Results for “module temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Close roof-mounted system temperature estimation for compliance to IEC TS 63126

When photovoltaic (PV) modules are installed on rooftops, the module temperature depends primarily on the geographic location and the mounting configuration. If the mounting structure does not provide sufficient airflow in a hot environment, the 98th percentile temperature will exceed 70°C, which according to IEC TS 63126 ED. 1, requires higher levels of thermal stability testing. However, there is no clear way to determine the temperature level needed for a particular location and system design. Here, in this work, we identify a relationship between the module standoff to the rooftop and the module temperature and propose methods to describe a minimum standoff for typical PV modules in a simple mounting configuration installed in a given location. For more complex system designs, we show how to determine an equivalent “effective standoff” that can be applied to generic calculations. Lastly, we show measurements and calculations from several systems to demonstrate how this method could work.

14 SOLAR ENERGY↗

Effect of collisional heat transfer in ICRF power modulation experiment on ASDEX Upgrade

ICRF (ion cyclotron range of frequencies) heating experiments were performed in D-H plasmas at various H concentrations on ASDEX Upgrade. The rf power was modulated to measure the electron power deposition profile from electron temperature modulation. To minimize the contribution from indirect collisional heating and the effect of radial transport, the rf power was modulated at 50 Hz. However, peaking of electron temperature modulation was still observed around the hydrogen cyclotron resonance indicating collisional heating contribution. Time dependent simulation of the hydrogen distribution function was performed for the discharges, using the full-wave code AORSA (E.F. Jaeger, et al., Phys. Plasmas, Vol. 8, page 1573 (2001)) coupled to the Fokker-Planck code CQL3D (R.W. Harvey, et al., Proc. IAEA (1992)). In the present experimental conditions, it was found that modulation of the collisional heating was comparable to that of direct wave damping. Impact of radial transport was also analyzed and found to appreciably smear out the modulation profile and reduce the phase delay.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature-insensitive laser frequency locking near absorption lines

Combined magnetically induced circular dichroism and Faraday rotation of an atomic vapor are used to develop a variant of the dichroic atomic vapor laser lock that eliminates lock sensitivity to temperature fluctuations of the cell. Operating conditions that eliminate first-order sensitivity to temperature fluctuations can be determined by low-frequency temperature modulation. This temperature-insensitive gyrotropic laser lock can be accurately understood with a simple model, that is in excellent agreement with observations in potassium vapor at laser frequencies in a 2 GHz range about the 770.1 nm absorption line. The methods can be readily adapted for other absorption lines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive bias temperature compensation circuit module

A passive bias temperature compensation module for silicon photomultiplier, avalanche photodiodes and similar photodetectors that possess a moderately linear temperature coefficient of gain and that may be compensated by varying an applied bias voltage. The module includes an electrical circuit and a method for determining component values to provide a constant voltage source to stabilize the gain of one or more photodetector devices. A temperature sensor in the module is held in close thermal contact with the photodetector and a filter capacitor is electrically close to the photodetector. The module is based on the concept of temperature sensitive voltage division which is applicable to situations in which large numbers of photodetectors must be gain-compensated for temperature variations over a wide range while maintaining excellent gain matching. The passive bias temperature compensation method enables multiple photodetectors to share a single constant voltage supply without loss of matching performance.

42 ENGINEERING↗

Nonvolatile logic elements based on magnetically coupled FSF structures.

We demonstrate the evolution of the anisotropic conductivity in the superconductor that is magnetically coupled with two adjacent ferromagnetic layers. Stripe magnetic domain structure in the ferromagnetic layers results in directional superconducting order parameter in the superconducting layer. The conductance anisotropy strongly depends on the period of the magnetic domains and the strength of the local magnetization. The anisotropic conductivity of up to three orders of magnitude can be achieved with spatial critical temperature modulation of 5% of Tc. The effect could be exploited in low temperature nonvolatile logic and storage elements

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reversible two-way tuning of thermal conductivity in an end-linked star-shaped thermoset

Polymeric thermal switches that can reversibly tune and significantly enhance their thermal conductivities are desirable for diverse applications in electronics, aerospace, automotives, and medicine; however, they are rarely achieved. Here, we report a polymer-based thermal switch consisting of an end-linked star-shaped thermoset with two independent thermal conductivity tuning mechanisms—strain and temperature modulation—that rapidly, reversibly, and cyclically modulate thermal conductivity. The end-linked star-shaped thermoset exhibits a strain-modulated thermal conductivity enhancement up to 11.5 at a fixed temperature of 60 °C (increasing from 0.15 to 2.1 W m –1 K –1 ). Additionally, it demonstrates a temperature-modulated thermal conductivity tuning ratio up to 2.3 at a fixed stretch of 2.5 (increasing from 0.17 to 0.39 W m –1 K –1 ). When combined, these two effects collectively enable the end-linked star-shaped thermoset to achieve a thermal conductivity tuning ratio up to 14.2. Moreover, the end-linked star-shaped thermoset demonstrates reversible tuning for over 1000 cycles. The reversible two-way tuning of thermal conductivity is attributed to the synergy of aligned amorphous chains, oriented crystalline domains, and increased crystallinity by elastically deforming the end-linked star-shaped thermoset.

42 ENGINEERING↗

Prediction of Climate-Specific Degradation Rate for Photovoltaic Encapsulant Discoloration

Encapsulant discoloration is a well-known field degradation mode of crystalline-silicon photovoltaic modules, particularly in the hot climate zones. The discoloration rate is influenced by several weathering factors, such as UV light, module temperature, and humidity, as well as the permeability of oxygen into the module. Here, a rate dependence model employing the modified Arrhenius equations to predict the degradation rate for encapsulant discoloration in different climates is presented. Two modeling approaches are introduced, which utilize the field and accelerated UV testing degradation data in conjunction with the field meteorological data to determine the acceleration factor for encapsulant browning. A novel method of accelerated UV stress testing at three simultaneous module temperatures in a single environmental chamber test run is implemented to estimate the activation energy for browning. The test was performed on three field-retrieved modules to capture the wear-out failure mechanism. The degradation in short-circuit current Isc rather than maximum power is used as a decisive parameter for the discoloration analysis. Furthermore, the developed model has been used to predict the Isc degradation rate for the Arizona field characterized by a hot and dry climate and is validated against the field-measured value. It has also been applied to other climate types, e.g., the cold and dry climate of New York.

14 SOLAR ENERGY↗

Machine-Learned Force Field for Molecular Dynamics Simulations of Nonequilibrium Ammonia Synthesis on Iron Catalysts

Ammonia (NH 3 ) is one of the most important industrial chemicals. The conventional NH 3 synthesis method-the Haber–Bosch process-converts atmospheric nitrogen (N 2 ) into NH 3 using H 2 with an iron (Fe) catalyst. However, this process requires high pressures (100–200 atm) and temperatures (700–800 K) near thermal equilibrium. Recently, Fe-based nanocatalysts have been reported to produce promising NH 3 yields under atmospheric pressures and temperature-modulated nonequilibrium conditions. Understanding the mechanism of nonequilibrium catalysis with programmed temperature variation could help to optimize this fully electrified and less energy-intensive process. Although reactive molecular dynamics (RMD) simulations can be a useful tool to model nonequilibrium catalytic processes, they require the development of accurate force fields (i.e., interatomic potentials). Here, we present a machine-learned (ML) force field within the Deep Potential MD (DPMD) framework, trained using periodic density functional theory (DFT) calculations, to model NH 3 synthesis on Fe catalysts with various surface adsorbates such as *N, *H, *N 2 , *H 2 , *NH, *NH 2 , and *NH 3 . Here, we generated the DFT data from static models of elementary reactions on the most stable (110) surface of body-centered cubic Fe, which then were augmented by data from constant number of particles–volume–temperature (NVT) DFT-MD trajectories at various temperatures. Finally, we utilized the fully optimized ML force field to investigate reaction dynamics at an Fe(110) surface at linearly increasing temperatures using NVT-DPMD simulations. Our simulations indicate that pulsed temperature ramping could prove favorable for NH3 synthesis. For example, we conducted ramping under multiple sets of conditions: (i) from 900 to 1200 K over periods of 0.1–0.3 ns for Fe surfaces precovered with N or NH along with H; and (ii) from 300 to 600 K over 0.1–0.3 ns for Fe surfaces precovered with NH 3 . While our simulations so far are limited to short time scales (very rapid heating), these observations shed light on the mechanism of the high NH 3 synthesis rate achieved in a novel temperature-modulated nonequilibrium catalytic reactor using pulsed heating and cooling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of second ion temperature on modulation stability of dust-acoustic solitary waves with dust charge variation

The derivative expansion perturbation method is applied to a cold plasma system consisting of dust grains with varying dust charge, electrons, and two species of ions with different temperatures. The basic system of equations is reduced to a nonlinear Schroedinger-type equation. The effect of the temperature of low temperature ions on the system parameters, e.g., angular frequency, group velocity, dispersion coefficient, and nonlinear coefficient, is investigated. It is found that the presence of low-temperature ions enhances the stability of the system. The small wave number limits of the coefficients of the nonlinear Schroedinger-type equation are found to agree exactly with the coefficients of the nonlinear Schroedinger-type equation obtained from the oscillatory solution of the Korteweg-de Vries equation of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reducing Operating Temperature in Photovoltaic Modules

Reducing the operating temperature of photovoltaic modules increases their efficiency and lifetime. This can be achieved by reducing the production of waste heat or by improving the rejection of waste heat. We tested, using a combination of simulation and experiment, several thermal modifications in each category. To predict operating temperature and energy yield changes in response to changes to the module, we implemented a physics-based transient simulation framework based almost entirely on measured properties. The most effective thermal modifications reduced the production of waste heat by reflecting unusable light from the cell or the module. Consistent with previous results and verified in this work through year-long simulations, the ideal reflector resulted in an annual irradiance-weighted temperature reduction of 3.8 K for crystalline silicon (c-Si). Our results illustrate that more realistic reflector concepts must balance detrimental optical effects with the intended thermal effects to realize the optimal energy production advantage. Methods improving thermal conductivity or back-side emissivity showed only modest improvements of less than 1 K. We also studied a GaAs module, which uses high-efficiency and high-subbandgap reflectivity to operate at an annual irradiance-weighted temperature 12 K cooler than that of a c-Si module under the same conditions.

14 SOLAR ENERGY↗

Barrier/bonding layers on bismuth telluride (Bi2Te3) for high temperature thermoelectric modules

In this research, a fundamental study is conducted to identify the materials and develop the processes for producing barrier/bonding composite on Bi 2 Te 3 for high temperature thermoelectric applications. The composite must meet four basic requirements: (a) prevent inter-diffusion between the electrode material, for our design, silver(Ag) and Bi 2 Te 3 , (b) bond well to Bi 2 Te 3 , (c) bond well to Ag electrode, and (d) do not themselves diffuse into Bi 2 Te 3 . The composites investigated include palladium (Pd), nickel/gold (Ni/Au), Ag, and titanium/gold (Ti/Au). After annealing at 250 °C for 200 h, only the Ti/Au design meets all four requirements. The thickness of Ti and Au, respectively, is only 100 nm. Other than meeting these four requirements, the Ti/Au layers exhibit excellent step coverage on the rough Bi 2 Te 3 surface even after the annealing process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling needs for very large systems.

Most system performance models assume a point measurement for irradiance and that, except for the impact of shading from nearby obstacles, incident irradiance is uniform across the array. Module temperature is also assumed to be uniform across the array. For small arrays and hourly-averaged simulations, this may be a reasonable assumption. Stein is conducting research to characterize variability in large systems and to develop models that can better accommodate large system factors. In large, multi-MW arrays, passing clouds may block sunlight from a portion of the array but never affect another portion. Figure 22 shows that two irradiance measurements at opposite ends of a multi-MW PV plant appear to have similar irradiance (left), but in fact the irradiance is not always the same (right). Module temperature may also vary across the array, with modules on the edges being cooler because they have greater wind exposure. Large arrays will also have long wire runs and will be subject to associated losses. Soiling patterns may also vary, with modules closer to the source of soiling, such as an agricultural field, receiving more dust load. One of the primary concerns associated with this effort is how to work with integrators to gain access to better and more comprehensive data for model development and validation.

14 SOLAR ENERGY↗

Interplay of pressure and temperature in modulating the magnetic properties of Cr 2 O 3

The spin-lattice interaction is pivotal in tailoring materials properties and is crucial for developing novel spintronic devices. Here, in the current work, we aim to explore the effects of pressure and temperature on the magnetic properties of Cr 2 O 3 to gain insights into its spin-lattice interaction. Through high-pressure neutron diffraction experiments, we observed an enhancement of the magnetic Bragg intensity with increasing pressure and it becomes more pronounced as the temperature increases. Results from first-principles calculations reveal a strengthening of the easy-axis magnetic anisotropy, doubling from 0 to 20 GPa. The exchange parameters, calculated based on this spin orientation, show an enhancement of the dominant magnetic interactions and an increase of magnetic ordering temperature when pressure increases. These findings suggest that the contributions from these two mechanisms are responsible for the observed increase in magnetic Bragg intensity.

Cr2O3↗

Pantropical Indo-Atlantic temperature gradient modulates multi-decadal AMOC variability in models and observations

Abstract Interconnections between ocean basins are recognized as an important driver of climate variability. Recent modeling evidence suggests that the North Atlantic climate can respond to persistent warming of the tropical Indian Ocean sea surface temperature (SST) relative to the rest of the tropics (rTIO). Here, we use observational data to demonstrate that multi-decadal changes in pantropical ocean temperature gradients lead to variations of an SST-based proxy of the Atlantic Meridional Overturning Circulation (AMOC). The largest contribution to this temperature gradient-AMOCconnection comes from gradients between the Indian and Atlantic Oceans. TherTIOindex yields the strongest connection of this tropical temperature gradient to theAMOC. Focusing on the internally generated signal in three observational products reveals that an SST-basedAMOCproxy index has closely followed low-frequency changes ofrTIOtemperature with about 26-year lag since 1870. Analyzing the pre-industrial control simulations of 44 CMIP6 climate models shows that theAMOCproxy index lags simulated mid-latitudeAMOCvariations by 4 ± 4 years. These model simulations reveal the mechanism connectingAMOCvariations to pantropical ocean temperature gradients at a 27 ± 2 years lag, matching the observed time lag in 28 out of the 44 analyzed models. rTIO temperature changes affect the North Atlantic climate through atmospheric planetary waves, impacting temperature and salinity in the subpolar North Atlantic, which modifies deep convection and ultimately the AMOC. Through this mechanism, observed internalrTIOvariations can serve as a multi-decadal precursor ofAMOCchanges with important implications forAMOCdynamics and predictability.

Meteorology & Atmospheric Sciences↗

Temperature-Dependent Light-Stabilized States in Thin-Film PV Modules: Preprint

Thin-film photovoltaic modules are known to exhibit light-induced transient behavior which interferes with accurate and repeatable measurements of power. Typically power measurements are made after a light exposure in order to target a 'light state' of the module that is representative of outdoor performance. Here we show that the concept of a unique light state is poorly defined for both CIGS and CdTe modules. Instead we find that their metastable state after a light exposure can depend on the temperature of the module during the exposure. We observe changes in power as large as 5.8% for a 20 degrees C difference in light exposure temperature. These results lead us to conclude that for applications in which reproducibility and repeatability are critical, module temperature should be tightly controlled during light exposure.

14 SOLAR ENERGY↗