Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Learning random networks for compression of still and moving images

Image compression for both still and moving images is an extremely important area of investigation, with numerous applications to videoconferencing, interactive education, home entertainment, and potential applications to earth observations, medical imaging, digital libraries, and many other areas. We describe work on a neural network methodology to compress/decompress still and moving images. We use the 'point-process' type neural network model which is closer to biophysical reality than standard models, and yet is mathematically much more tractable. We currently achieve compression ratios of the order of 120:1 for moving grey-level images, based on a combination of motion detection and compression. The observed signal-to-noise ratio varies from values above 25 to more than 35. The method is computationally fast so that compression and decompression can be carried out in real-time. It uses the adaptive capabilities of a set of neural networks so as to select varying compression ratios in real-time as a function of quality achieved. It also uses a motion detector which will avoid retransmitting portions of the image which have varied little from the previous frame. Further improvements can be achieved by using on-line learning during compression, and by appropriate compensation of nonlinearities in the compression/decompression scheme. We expect to go well beyond the 250:1 compression level for color images with good quality levels.

Gelenbe, Erol↗

Stabilization of posture by precision contact of the index finger

Postural sway during quiet stance increases if sight of the surroundings is denied. We studied how sensory-motor information about body displacement provided by contact of the index finger with a stationary bar can be used to stabilize balance in the absence of vision. Stabilization equivalent to the contribution conferred by vision was achieved at contact force levels less than 1 N. This value is much below that necessary to provide significant physical stabilization of the body. We interpret our findings in relation to tactile thresholds for motion detection, "precision grip," and proprioceptive and sensory-motor information about the configuration of the arm to the torso. In conditions allowing higher force levels at the fingertip (5-8 N), subjects assumed a passively stable state to stabilize their stance.

Non-NASA Center↗

Preservation and Enhancement of the Spacewatch Data Archives

In March of 1998, the asteroid 1997 XF11 was announced to be potentially hazardous after being tracked over 90 days. A potential two year wait for confirming observations was shortened to under 24 hours because of the existence of archived photographic prediscovery images. Spacewatch was a pioneer in using CCD scanning and possesses a valuable digital archive of its scans. Unfortunately these data are aging on magnetic tape and will soon be lost. Since 1990, the Spacewatch project gathered some 1.5 Terabytes of scan data covering roughly 75,000 degrees of sky to a limiting magnitude of V = 21.5. The data have not yet been mined for all of their asteroids for scientific studies and orbit determination. Spacewatch's real-time motion detection program MODP was constrained by the computers of the era to use simplified image processing algorithms at a reduced efficiency. Jedicke and Herron estimated MODP's efficiency at finding asteroids to be approximately 60 percent to V=18 and improving somewhat thereafter. This lead to a substantial bias correction in their analyses. Larsen has developed a MODP replacement capable in excess of 90 percent efficiency in the same range and able to push a magnitude fainter in completeness. We propose a program of post-processing and re-archiving Spacewatch data. Our scans would be transferred from tape to CD-ROMs and converted to FITS images -- establishing a consistent data format and media for both past and future Spacewatch observations. Larsen's MODP replacement would mine these data for previously undetected motions, which would be made available to the Minor Planet Center and our ongoing asteroid population studies. A searchable observation record would be made generally available for prediscovery work. We estimate the net asteroid yield of this proposal is equivalent to three full years of Spacewatch operations.

Larsen, Jeffrey A.↗

Adapt: A Weather Radar Data Analysis and Nowcasting Platform for Informed Adaptive Scanning

SF-26-021 Adapt is a data processing platform for real-time data analysis, short term prediction of targets convective cells and tracking for archived data. It provides tools for downloading, processing, segmenting, projecting, analyzing, and visualizing storm cell data from weather radar. The pipeline includes cell detection, motion estimation using optical flow, cell property extraction, and persistence to NetCDF and SQLite/Parquet for guiding adaptive scanning.

Raut, Bhupendra Ashokrao [Argonne National Laborat↗

Further Measurements of Beam-Beam Interactions in a Gear-Changing System in DESIREE

In this work we detail experiments performed on a gear-changing system using the Double ElectroStatic Ion Ring ExpEriment (DESIREE). A gear-changing system is one where there are different harmonic numbers in each ring. This experiment used carbon and nitrogen beams in a 4 on 3 gear-changing arrangement, with the last bunch of each left off. The bunch length can be measured and synchrotron motion detected. We performed this measurement on three different values of carbon current, and present the differences in the bunch length frequency spectrum here, which correspond to twice the synchrotron frequencies.

Nissen, E. A.↗

Vibrating ribbon bolometer: A concept

Incident electromagnetic radiation pulses maintain bolometer's sensitive element in state of resonant oscillation and correlate amplitude of oscillation with incident radiation power. Bolometer can be employed with other devices for detecting motion of ribbon.

Dimeff, J.↗

Digital TV processing system

Two digital video data compression systems directly applicable to the Space Shuttle TV Communication System were described: (1) For the uplink, a low rate monochrome data compressor is used. The compression is achieved by using a motion detection technique in the Hadamard domain. To transform the variable source rate into a fixed rate, an adaptive rate buffer is provided. (2) For the downlink, a color data compressor is considered. The compression is achieved first by intra-color transformation of the original signal vector, into a vector which has lower information entropy. Then two-dimensional data compression techniques are applied to the Hadamard transformed components of this last vector. Mathematical models and data reliability analyses were also provided for the above video data compression techniques transmitted over a channel encoded Gaussian channel. It was shown that substantial gains can be achieved by the combination of video source and channel coding.

Source record↗

Observations of long-period Cepheids between l = 294 and 331 deg

Photoelectric and spectroscopic observations of long-period Cepheids, as well as 21-cm profiles in the directions of these young stars, are presented for the Crux-Centaurus-Circinus-Norma section of the Milky Way. The UBV data have been used to revise periods and light-curve parameters and ultimately to calculate the distances of these stars. From the spectroscopic information velocity estimates have been made. Finally, the stellar velocities have been compared with H I gas motions detected along the same line of sight. These results are briefly discussed with a view to understanding the spiral structure of the region.

Grayzeck, E. J.↗

Photometer used for response time measurement

Photometer detects motion for measuring response speed and acceleration of servocontrol system. Instrument senses selected output movement shortly after operator activates hand-controlled input. Time delay is measured on X/T recorder and response calculated. With suitable motion targets, photometer measures any open- or closed-loop servoresponse and servorate or computer lag without system disturbance.

Da Silva, A. J.↗

Space station on-orbit identification and performance monitor

This paper describes the generic applications of on-orbit identification to the reference Space Station configuration currently under consideration by NASA. Identification functions are categorized, and the various methods for extracting parameter estimates are correlated with the sensing of specific characteristics of interest to both engineering subsystems and users of the Station's commercial and scientific facilities. A case study of crew motion detection and identification is included to illustrate the application to the Station's disturbance environment and plant characterization using accelerometer sensing. Onboard implementation architecture is discussed from the viewpoint of maximizing integration of the identification process with the flight subsystem's data and signal flow.

Mettler, E.↗

Real-time image processing II; Proceedings of the Meeting, Orlando, FL, Apr. 16-18, 1990

The present conference discusses topics in the fields of feature extraction and implementation, filter and correlation algorithms, optical correlators, high-level algorithms, and digital image processing for ranging and remote driving. Attention is given to a nonlinear filter derived from topological image features, IR image segmentation through iterative thresholding, orthogonal subspaces for correlation masking, composite filter trees and image recognition via binary search, and features of matrix-coherent optical image processing. Also discussed are multitarget tracking via hybrid joint transform correlator, binary joint Fourier transform correlator considerations, global image processing operations on parallel architectures, real-time implementation of a differential range finder, and real-time binocular stereo range and motion detection.

Juday, Richard D.↗

A TEOM (tm) particulate monitor for comet dust, near Earth space, and planetary atmospheres

Scientific missions to comets, near earth space, and planetary atmospheres require particulate and mass accumulation instrumentation for both scientific and navigation purposes. The Rupprecht & Patashnick tapered element oscillating microbalance can accurately measure both mass flux and mass distribution of particulates over a wide range of particle sizes and loadings. Individual particles of milligram size down to a few picograms can be resolved and counted, and the accumulation of smaller particles or molecular deposition can be accurately measured using the sensors perfected and toughened under this contract. No other sensor has the dynamic range or sensitivity attained by these picogram direct mass measurement sensors. The purpose of this contract was to develop and implement reliable and repeatable manufacturing methods; build and test prototype sensors; and outline a quality control program. A dust 'thrower' was to be designed and built, and used to verify performance. Characterization and improvement of the optical motion detection system and drive feedback circuitry was to be undertaken, with emphasis on reliability, low noise, and low power consumption. All the goals of the contract were met or exceeded. An automated glass puller was built and used to make repeatable tapered elements. Materials and assembly methods were standardized, and controllers and calibrated fixtures were developed and used in all phases of preparing, coating and assembling the sensors. Quality control and reliability resulted from the use of calibrated manufacturing equipment with measurable working parameters. Thermal and vibration testing of completed prototypes showed low temperature sensitivity and high vibration tolerance. An electrostatic dust thrower was used in vacuum to throw particles from 2 x 10(exp 6) g to 7 x 10(exp -12) g in size. Using long averaging times, particles as small as 0.7 to 4 x 10(exp 11) g were weighted to resolutions in the 5 to 9 x 10(exp -13) g range. The drive circuit and optics systems were developed beyond what was anticipated in the contract, and are now virtually flight prototypes. There is already commercial interest in the developed capability of measuring picogram mass losses and gains. One area is contamination and outgassing research, both measuring picogram losses from samples and collecting products of outgassing.

Source record↗

Real-time processor for staring receivers

The design, fabrication, and testing of a state-of-the-art, high-throughput on-focal plane IR-image signal processor is described. The processing functions performed are frame differencing and thresholding. The final focal plane array will consist of a 128 x 128-pixel platinum-silicide detector bump-mounted to an on-chip CCD multiplexer. The processor is in a 128-channel parallel-pipeline format. Each channel consists of a pixel regenerator (charge differencer), 128-pixel frame store CCD memory, pixel differencer, second pixel regenerator, thresholder (analog comparator), and digital latch. Four parallel analog outputs and four parallel digital outputs are included. The digital outputs provide a bit map of the image. All analog clock signals (128 KHz, 256 KHz, and 5 MHz) are generated by on-chip TTL-input clock drivers. TTL clock driver inputs are generated off-chip. The technology is low-temperature surface and buried channel CCD/CMOS/indium bump. The design goal was 8-bit resolution at 77 K and 1000 frames/s. Applications include point- or extended-target motion detection with thresholding. Design trade-offs and enhancements (such as on-chip detector gain compensation and a simple window processor) are discussed.

Hanzal, Brian↗

Getting the Bigger Picture With Digital Surveillance

Through a Space Act Agreement, Diebold, Inc., acquired the exclusive rights to Glenn Research Center's patented video observation technology, originally designed to accelerate video image analysis for various ongoing and future space applications. Diebold implemented the technology into its AccuTrack digital, color video recorder, a state-of- the-art surveillance product that uses motion detection for around-the- clock monitoring. AccuTrack captures digitally signed images and transaction data in real-time. This process replaces the onerous tasks involved in operating a VCR-based surveillance system, and subsequently eliminates the need for central viewing and tape archiving locations altogether. AccuTrack can monitor an entire bank facility, including four automated teller machines, multiple teller lines, and new account areas, all from one central location.

Source record↗

Sensorimotor integration in human postural control

It is generally accepted that human bipedal upright stance is achieved by feedback mechanisms that generate an appropriate corrective torque based on body-sway motion detected primarily by visual, vestibular, and proprioceptive sensory systems. Because orientation information from the various senses is not always available (eyes closed) or accurate (compliant support surface), the postural control system must somehow adjust to maintain stance in a wide variety of environmental conditions. This is the sensorimotor integration problem that we investigated by evoking anterior-posterior (AP) body sway using pseudorandom rotation of the visual surround and/or support surface (amplitudes 0.5-8 degrees ) in both normal subjects and subjects with severe bilateral vestibular loss (VL). AP rotation of body center-of-mass (COM) was measured in response to six conditions offering different combinations of available sensory information. Stimulus-response data were analyzed using spectral analysis to compute transfer functions and coherence functions over a frequency range from 0.017 to 2.23 Hz. Stimulus-response data were quite linear for any given condition and amplitude. However, overall behavior in normal subjects was nonlinear because gain decreased and phase functions sometimes changed with increasing stimulus amplitude. "Sensory channel reweighting" could account for this nonlinear behavior with subjects showing increasing reliance on vestibular cues as stimulus amplitudes increased. VL subjects could not perform this reweighting, and their stimulus-response behavior remained quite linear. Transfer function curve fits based on a simple feedback control model provided estimates of postural stiffness, damping, and feedback time delay. There were only small changes in these parameters with increasing visual stimulus amplitude. However, stiffness increased as much as 60% with increasing support surface amplitude. To maintain postural stability and avoid resonant behavior, an increase in stiffness should be accompanied by a corresponding increase in damping. Increased damping was achieved primarily by decreasing the apparent time delay of feedback control rather than by changing the damping coefficient (i.e., corrective torque related to body-sway velocity). In normal subjects, stiffness and damping were highly correlated with body mass and moment of inertia, with stiffness always about 1/3 larger than necessary to resist the destabilizing torque due to gravity. The stiffness parameter in some VL subjects was larger compared with normal subjects, suggesting that they may use increased stiffness to help compensate for their loss. Overall results show that the simple act of standing quietly depends on a remarkably complex sensorimotor control system.

NASA Discipline Neuroscience↗

FPGA-Based Networked Phasemeter for a Heterodyne Interferometer

A document discusses a component of a laser metrology system designed to measure displacements along the line of sight with precision on the order of a tenth the diameter of an atom. This component, the phasemeter, measures the relative phase of two electrical signals and transfers that information to a computer. Because the metrology system measures the differences between two optical paths, the phasemeter has two inputs, called measure and reference. The reference signal is nominally a perfect square wave with a 50- percent duty cycle (though only rising edges are used). As the metrology system detects motion, the difference between the reference and measure signal phases is proportional to the displacement of the motion. The phasemeter, therefore, counts the elapsed time between rising edges in the two signals, and converts the time into an estimate of phase delay. The hardware consists of a circuit board that plugs into a COTS (commercial, off-the- shelf) Spartan-III FPGA (field-programmable gate array) evaluation board. It has two BNC inputs, (reference and measure), a CMOS logic chip to buffer the inputs, and an Ethernet jack for transmitting reduced-data to a PC. Two extra BNC connectors can be attached for future expandability, such as external synchronization. Each phasemeter handles one metrology channel. A bank of six phasemeters (and two zero-crossing detector cards) with an Ethernet switch can monitor the rigid body motion of an object. This device is smaller and cheaper than existing zero-crossing phasemeters. Also, because it uses Ethernet for communication with a computer, instead of a VME bridge, it is much easier to use. The phasemeter is a key part of the Precision Deployable Apertures and Structures strategic R&D effort to design large, deployable, segmented space telescopes.

Rao, Shanti↗