At least 55 records · Page 3

Cooperative Load Scheduling for Multiple Aggregators Using Hierarchical ADMM

Demand response (DR) serves an important role in improving the efficiency and stability of power systems. In recent years, with advances in communication and smart device technologies, many aggregators have emerged to facilitate end customer participation in DR programs. These aggregators, equipped with customized optimal control algorithms, are capable of providing various grid services. Among them is load scheduling during DR events, namely following a load signal provided by the utility company while minimizing overall customer discomfort. However, as the number of aggregators keeps increasing, it becomes challenging for utility companies to conduct load scheduling for multiple aggregators and generate reference signals for each of them. This paper proposes an optimization framework using hierarchical alternating direction method of multipliers (H-ADMM) to optimally generate load following signals for multiple aggregators. Under this framework, utility and multiple aggregators work in a cooperative manner, aiming at minimizing an overall system cost from different levels of the power system hierarchy, while protecting user privacy. A case study has been conducted in a system with multiple aggregators, based on control of HVAC loads. Experimental results validate the effectiveness of the proposed algorithm.

ADMM↗

Cooperative Load Scheduling for Multiple Aggregators Using Hierarchical ADMM

Demand response (DR) serves an important role in improving the efficiency and stability of power systems. In recent years, with advances in communication and smart device technologies, many aggregators have emerged to facilitate end customer participation in DR programs. These aggregators, equipped with customized optimal control algorithms, are capable of providing various grid services. Among them is load scheduling during DR events, namely following a load signal provided by the utility company while minimizing overall customer discomfort. However, as the number of aggregators keeps increasing, it becomes challenging for utility companies to conduct load scheduling for multiple aggregators and generate reference signals for each of them. This paper proposes an optimization framework using hierarchical alternating direction method of multipliers (H-ADMM) to optimally generate load following signals for multiple aggregators. Under this framework, utility and multiple aggregators work in a cooperative manner, aiming at minimizing an overall system cost from different levels of the power system hierarchy, while protecting user privacy. A case study has been conducted in a system with multiple aggregators, based on control of HVAC loads. Experimental results validate the effectiveness of the proposed algorithm.

97 MATHEMATICS AND COMPUTING↗

Cooperative Load Scheduling for Multiple Aggregators Using Hierarchical ADMM: Preprint

Demand response (DR) serves an important role in improving the efficiency and stability of power systems. In recent years, with advances in communication and smart device technologies, many aggregators have emerged to facilitate end customer participation in DR programs. These aggregators, equipped with customized optimal control algorithms, are capable of providing various grid services. Among them is load scheduling during DR events, namely following a load signal provided by the utility company while minimizing overall customer discomfort. However, as the number of aggregators keeps increasing, it becomes challenging for utility companies to conduct load scheduling for multiple aggregators and generate reference signals for each of them. This paper proposes an optimization framework using hierarchical alternating direction method of multipliers (H-ADMM) to optimally generate load following signals for multiple aggregators. Under this framework, utility and multiple aggregators work in a cooperative manner, aiming at minimizing an overall system cost from different levels of the power system hierarchy, while protecting user privacy. A case study has been conducted in a system with multiple aggregators, based on control of HVAC loads. Experimental results validate the effectiveness of the proposed algorithm.

97 MATHEMATICS AND COMPUTING↗

Weather Sensitive High Spatio-Temporal Resolution Transportation Electric Load Profiles For Multiple Decarbonization Pathways

Electrification of transport compounded with climate change will transform hourly load profiles and their response to weather. We present a novel approach to generating hourly electric load profiles that considers charging strategies and evolving sensitivity to temperature. The approach consists of downscaling annual state-scale sectoral load projections from the multisectoral Global Change Analysis Model (GCAM) into hourly electric load profiles leveraging high resolution climate and population datasets. Profiles are developed and evaluated at the Balancing Authority scale, with a 5-year increment until 2050 over the Western U.S. Interconnect for multiple decarbonization pathways and climate scenarios. The datasets are readily available for production cost model analysis. Our open source approach is transferable to other regions.

Decarbonization, tranportation, Electric vehicle c↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Analysis of Wind Power and Load Data at Multiple Time Scales

In this study we develop and apply new methods of data analysis for high resolution wind power and system load time series, to improve our understanding of how to characterize highly variable wind power output and the correlations between wind power and load. These methods are applied to wind and load data from the ERCOT region, and wind power output from the PJM and NYISO areas. We use a wavelet transform to apply mathematically well-defined operations of smoothing and differencing to the time series data. This approach produces a set of time series of the changes in wind power and load (or ?deltas?), over a range of times scales from a few seconds to approximately one hour. A number of statistical measures of these time series are calculated. We present sample distributions, and devise a method for fitting the empirical distribution shape in the tails. We also evaluate the degree of serial correlation, and linear correlation between wind and load. Our examination of the data shows clearly that the deltas do not follow a Gaussian shape; the distribution is exponential near the center and appears to follow a power law for larger fluctuations. Gaussian distributions are frequently used in modeling studies. These are likely to over-estimate the probability of small to moderate deviations. This in turn may lead to an over-estimation of the additional reserve requirement (hence the cost) for high penetration of wind. The Gaussian assumption provides no meaningful information about the real likelihood of large fluctuations. The possibility of a power law distribution is interesting because it suggests that the distribution shape for of wind power fluctuations may become independent of system size for large enough systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Collectively loading programs in a multiple program multiple data environment

Techniques are disclosed for loading programs efficiently in a parallel computing system. In one embodiment, nodes of the parallel computing system receive a load description file which indicates, for each program of a multiple program multiple data (MPMD) job, nodes which are to load the program. The nodes determine, using collective operations, a total number of programs to load and a number of programs to load in parallel. The nodes further generate a class route for each program to be loaded in parallel, where the class route generated for a particular program includes only those nodes on which the program needs to be loaded. For each class route, a node is selected using a collective operation to be a load leader which accesses a file system to load the program associated with a class route and broadcasts the program via the class route to other nodes which require the program.

97 MATHEMATICS AND COMPUTING↗

Collectively loading programs in a multiple program multiple data environment

Techniques are disclosed for loading programs efficiently in a parallel computing system. In one embodiment, nodes of the parallel computing system receive a load description file which indicates, for each program of a multiple program multiple data (MPMD) job, nodes which are to load the program. The nodes determine, using collective operations, a total number of programs to load and a number of programs to load in parallel. The nodes further generate a class route for each program to be loaded in parallel, where the class route generated for a particular program includes only those nodes on which the program needs to be loaded. For each class route, a node is selected using a collective operation to be a load leader which accesses a file system to load the program associated with a class route and broadcasts the program via the class route to other nodes which require the program.

97 MATHEMATICS AND COMPUTING↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Note: Lateral force microscope calibration using multiple location pivot loading of rectangular cantilevers

This note outlines a calibration method for atomic force microscope friction measurement that uses the ''pivot'' method of [Bogdanovic et al., Colloids Surf. B 19, 397 (2000)] to generate optical lever sensitivities for known torque applied to rectangular cantilevers. We demonstrate the key calibration parameter to be a linear function of the position at which it is determined along the length of the cantilevers. In this way the optical lever system can be calibrated for cantilever torque by applying loads at locations along the length of a cantilever, away from the integrated tip, so that issues such as tip damage or interference can be avoided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Validation Testing of TruckScan to Assay Large Sacks of Fukushima Radioactive Debris on a Truck

As a result of the March 2011 earthquake and resulting tsunami in Japan, there was a serious accident at the Fukushima Dai-ichi Nuclear Power Plant. This accident has contaminated soil and vegetation in a wide area around the plant. Decontamination projects over the last 4 years have resulted in large numbers of 1 cubic meter canvas bags of debris, commonly called Super Sacks [SS]. These are currently stored nearby where they were generated, but starting in 2015, they will be moved to various Interim Storage Facilities [ISF]. Trucks will typically carry 8-20 of these SSs. When the trucks arrive at the ISF they need to be rapidly sorted into groups according to radioactivity level, for efficient subsequent processing. Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for use at these ISFs. The TruckScan system must measure the entire truck loaded with multiple closely packed SSs, and generate a nuclide specific assay report showing the radioactivity in each individual SS. The Canberra-Japan office, along with Obayashi Corporation have performed validation testing to demonstrate to the regulatory authorities that the proposed technique was sufficiently accurate. These validation tests were conducted at a temporary storage area in Fukushima prefecture. Decontaminated waste of various representative types and of various levels of radioactivity was gathered and mixed to create homogeneous volumes. These volumes were sampled multiple times and assayed with laboratory HPGe detectors to determine the reference concentration of each pile. Multiple SSs were loaded from each pile. Some of the SSs were filled 50% full, others 75% full, and others 100% full, to represent the typical loading configuration of the existing SSs in the field. The content of the SSs are either sand, soil, or vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. These SSs with known concentrations of Cs-134 and Cs-137 were then loaded onto trucks in a variety of configurations, typical of how they might be on the real trucks. A partial system was installed at the site and used to assay these trucks with the various loading configurations. Whereas the full system will have 8 collimated 3 x 3'' NaI detectors, the test system only had two detectors; therefore the truck was moved and counted 4 times. The data were acquired and analyzed with the Canberra Genie software to determine the peak counts for both Cesium nuclides. That data was then analyzed with a prototype version of a Maximum Entropy algorithm, to determine the individual SS activity. The goal of the validation tests was to demonstrate that the system could detect 1000 Bq/kg in 15 seconds, and to determine how accurately it could quantify individual SSs. The validation tests demonstrated that the product would perform as predicted. The TruckScan results were consistent with the sample assay results [y = 1.0029 x, R{sup 2} = 0.914]. The Total Propagated Uncertainty, including both uncertainties from these tests and others that were estimated but not tested was 16.6% percent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind and Load Forecast Error Model for Multiple Geographically Distributed Forecasts

The impact of wind and load forecast errors on power grid operations is frequently evaluated by conducting multi-variant studies, where these errors are simulated repeatedly as random processes based on their known statistical characteristics. To generate these errors correctly, we need to reflect their distributions (which do not necessarily follow a known distribution law), standard deviations, auto- and cross-correlations. For instance, load and wind forecast errors can be closely correlated in different zones of the system. This paper introduces a new methodology for generating multiple cross-correlated random processes to simulate forecast error curves based on a transition probability matrix computed from an empirical error distribution function. The matrix will be used to generate new error time series with statistical features similar to observed errors. We present the derivation of the method and present some experimental results by generating new error forecasts together with their statistics.

17 WIND ENERGY↗

Matrix multiplication operations using pair-wise load and splat operations

Mechanisms for performing a matrix multiplication operation are provided. A vector load operation is performed to load a first vector operand of the matrix multiplication operation to a first target vector register. A pair-wise load and splat operation is performed to load a pair of scalar values of a second vector operand and replicate the pair of scalar values within a second target vector register. An operation is performed on elements of the first target vector register and elements of the second target vector register to generate a partial product of the matrix multiplication operation. The partial product is accumulated with other partial products and a resulting accumulated partial product is stored. This operation may be repeated for a second pair of scalar values of the second vector operand.

97 MATHEMATICS AND COMPUTING↗

Deformation and fracture of explosion-welded Ti/Al plates: A synchrotron-based study

Here, explosion-welded Ti/Al plates are characterized with energy dispersive spectroscopy and x-ray computed tomography, and exhibit smooth, well-jointed, interface. We perform dynamic and quasi-static uniaxial tension experiments on Ti/Al with the loading direction either perpendicular or parallel to the Ti/Al interface, using a mini split Hopkinson tension bar and a material testing system in conjunction with time-resolved synchrotron x-ray imaging. X-ray imaging and strain-field mapping reveal different deformation mechanisms responsible for anisotropic bulk-scale responses, including yield strength, ductility and rate sensitivity. Deformation and fracture are achieved predominantly in Al layer for perpendicular loading, but both Ti and Al layers as well as the interface play a role for parallel loading. The rate sensitivity of Ti/Al follows those of the constituent metals. For perpendicular loading, single deformation band develops in Al layer under quasi-static loading, while multiple deformation bands nucleate simultaneously under dynamic loading, leading to a higher dynamic fracture strain. For parallel loading, the interface impedes the growth of deformation and results in increased ductility of Ti/Al under quasi-static loading, while interface fracture occurs under dynamic loading due to the disparity in Poisson's contraction.

36 MATERIALS SCIENCE↗

Direct measurement of the magnetic penetration depth by magnetic force microscopy

We present an experimental approach using magnetic force microscopy for measurements of the absolute value of the magnetic penetration depth λ in superconductors. λ is obtained in a simple and robust way without introducing any tip modeling procedure via direct comparison of the Meissner response curves for a material of interest to those measured for a reference sample. Using a well-characterized Nb film as a reference, we determine the absolute value of λ in a Ba(Fe 0.92 Co 0.08 ) 2 As 2 single crystal and a MgB 2 thin film through a comparative experiment. Our apparatus features simultaneous loading of multiple samples, and allows straightforward measurement of the absolute value of λ in superconducting thin film or single-crystal samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗