Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexing capability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Performance of the HIRS/2 instrument on TIROS-N

The High Resolution Infrared Radiation Sounder (HIRS/2) was developed and flown on the TIROS-N satellite as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow radiation channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7 K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic features, operating characteristics and performance of the instrument in test are described. Early orbital information from the TIROS-N launched on October 13, 1978 is given and some observations on system quality are made.

Koenig, E. W.↗

Application of new electro-optic technology to Space Station Freedom data management system

A low risk design methodology to permit the local bus structures to support increased data carrying capacities and to speed messages and data flow between nodes or stations on the Space Station Freedom Data Management System in anticipation of growing requirements was evaluated and recommended. The recommended design employs a collateral fiber optic technique that follows a NATO avionic standard that is developed, tested, and available. Application of this process will permit a potential 25 fold increase in data transfer performance on the local wire bus network with a fiber optic network, maintaining the functionality of the low-speed bus and supporting all of the redundant transmission and fault detection capabilities designed into the existing system. The application of wavelength division multiplexing (WDM) technology to both the local data bus and global data bus segments of the Data Management System to support anticipated additional highspeed data transmission requirements was also examined. Techniques were examined to provide a dual wavelength implementation of the fiber optic collateral networks. This dual wavelength implementation would permit each local bus to support two simultaneous high-speed transfers on the same fiber optic bus structure and operate within the limits of the existing protocol standard. A second WDM study examined the use of spectral sliced technology to provide a fourfold increase in the Fiber Distributed Data Interface (FDDI) global bus networks without requiring modifications to the existing installed cable plant. Computer simulations presented indicated that this data rate improvement can be achieved with commercially available optical components.

Husbands, C. R.↗

Select Electronic Parts Operation at Extreme Low Temperature

The purpose of the study presented in this paper is to extend the test period of a selected set of electronics parts at cryogenic condition to dwell period of about 24 hours to demonstrate extreme cold operational capability of these components. The parts tested are tantalum polymer, BX and P90 type ceramic capacitors, thick film resistors, analog multiplexers, a digital inverter, and a D-flip-flop. These parts were tested to assist identifying candidate components that can be used for development of a cold capable telemetry board. There are several past investigations that have shown that COTS (commercial-off-the-shelf) capacitors and resistors tested at cryogenic temperatures and frequencies up to 10MHz did not exhibit significant changes in capacitance and resistance values. Also, there are several test results for active parts. These past tests collected measurements during a temperature sweep from room temperature down to cryogenic temperature with very short dwell time at cryogenic temperature, and back to room temperature. This study extends the operational dwell time to at least 24 hours and returning to room temperature operation without significant degradation in performance, thus, demonstrating the potential for longer dwell time in actual operation in these extreme cold temperatures and a method for identifying the cold operability.

Ashtijou, Mohammad↗

NASA standard communications and data handling subsystem

The paper gives a functional description and discusses hardware implementation for the Communication and Data Handling (C&DH) subsystem of the Multimission Modular Spacecraft. The C&DH subsystem: (1) provides the command and telemetry link between the spacecraft and the terrestrial system, (2) distributes commands to and collects telemetry from all spacecraft systems via a duplex serial multiplex data bus and remote interface units, and (3) contains onboard computation capability. The C&DH is a single 4 x 4 x 1-1/2 foot module; the stuffed module weighs 270 lbs including 60 lbs of mission unique weight. The hardware is versatile and cost effective, and its modular structure permits repair, refurbishment, and even modification/updating in space

Robinson, D. L.↗

Advanced Fiber-optic Monitoring System for Space-flight Applications

Researchers at Luna Innovations Inc. and the National Aeronautic and Space Administration s Marshall Space Flight Center (NASA MSFC) have developed an integrated fiber-optic sensor system for real-time monitoring of chemical contaminants and whole-cell bacterial pathogens in water. The system integrates interferometric and evanescent-wave optical fiber-based sensing methodologies with atomic force microscopy (AFM) and long-period grating (LPG) technology to provide versatile measurement capability for both micro- and nano-scale analytes. Sensors can be multiplexed in an array format and embedded in a totally self-contained laboratory card for use with an automated microfluidics platform.

Hull, M. S.↗

Cell-level battery charge/discharge protection system

The paper describes three design approaches to individual cell monitoring and control for sealed secondary battery cells. One technique involves a modular strap-on single cell protector which contains all the electronics required for monitoring cell voltage, responding to external commands, and forming a bypass circuit for the cell. A second technique, the multiplexed cell protector, uses common circuitry to monitor and control each cell in a battery pack. The third technique, the computerized cell protector, by replacing the hard-wired logic of the multiplexed cell protector with a microprocessor, achieves greatest control flexibility and inherent computational capability with a minimum parts count implementation.

Donovan, R. L.↗

Doubly multiplexing dispersive spectrometer.

Description of a spectrometer that incorporates 19 entrances and 19 exit slots. The instrument's dual capability to perform either one-dimensional imaging or alternately to give a spectrum with a high SNR over the entire source is shown. The instrument operates in the Littrow mode at f/8. The slot width and length for each mask are 0.625 and 3.5 mm, respectively, giving a total aperture length of 12.1 mm. The corresponding resolving power at 1.7 microns is 230.

Phillips, P. G.↗

Simple Laser Communications Terminal for Downlink from Earth Orbit at Rates Exceeding 10 Gb/s

A compact, low-cost laser communications transceiver was prototyped for downlinking data at 10 Gb/s from Earth-orbiting spacecraft. The design can be implemented using flight-grade parts. With emphasis on simplicity, compactness, and light weight of the flight transceiver, the reduced-complexity design and development approach involves: 1. A high-bandwidth coarse wavelength division multiplexed (CWDM) (4 2.5 or 10-Gb/s data-rate) downlink transmitter. To simplify the system, emphasis is on the downlink. Optical uplink data rate is modest (due to existing and adequate RF uplink capability). 2. Highly simplified and compact 5-cm diameter clear aperture optics assembly is configured to single transmit and receive aperture laser signals. About 2 W of 4-channel multiplexed (1,540 to 1,555 nm) optically amplified laser power is coupled to the optical assembly through a fiber optic cable. It contains a highly compact, precision-pointing capability two-axis gimbal assembly to coarse point the optics assembly. A fast steering mirror, built into the optical path of the optical assembly, is used to remove residual pointing disturbances from the gimbal. Acquisition, pointing, and tracking are assisted by a beacon laser transmitted from the ground and received by the optical assembly, which will allow transmission of a laser beam. 3. Shifting the link burden to the ground by relying on direct detection optical receivers retrofitted to 1-m-diameter ground telescopes. 4. Favored mass and volume reduction over power-consumption reduction. The two major variables that are available include laser transmit power at either end of the link, and telescope aperture diameter at each end of the link. Increased laser power is traded for smaller-aperture diameters. 5. Use of commercially available spacequalified or qualifiable components with traceability to flight qualification (i.e., a flight-qualified version is commercially available). An example is use of Telecordia-qualified fiber optic communication components including active components (lasers, amplifiers, photodetectors) that, except for vacuum and radiation, meet most of the qualifications required for space. 6. Use of CWDM technique at the flight transmitter for operation at four channels (each at 2.5 Gb/s or a total of 10 Gb/s data rate). Applying this technique allows utilization of larger active area photodetectors at the ground station. This minimizes atmospheric scintillation/turbulence induced losses on the received beam at the ground terminal. 7. Use of forward-error-correction and deep-interleaver codes to minimize atmospheric turbulence effects on the downlink beam. Target mass and power consumption for the flight data transmitter system is less than 10 kg and approximately 60 W for the 400-km orbit (900-km slant range), and 12 kg and 120 W for the 2,000-km orbit (6,000-km slant range). The higher mass and power for the latter are the result of employing a higher-power laser only.

Kovalik, Joseph M.↗

Space platform accommodations

The results of studies performed at NASA of five space platform design reference missions (DRM) are presented. The DRM's were planned in an effort to eliminate problems, rather than to enhance optimization. A diagram of each payload is included, and the space platform concept is presented with the most important features being a continuous total power supply of 12.5 kW to the payloads at 30 and/or 120 Vdc regulated, a high-rate multiplexer with a total output of 48 Mbps, and and a thermal control system capable of dissipating the platform power output at payload fluid temperatures of 0 C to 3 C. Payload interface requirements were analyzed and appropriate integration hardware was added. Payload viewing characteristics are considered, and resource use is discussed. It is concluded that, in payload applications, efficient use of STS transportation and the platform must be considered.

Bailey, W.↗

Science Enabling ASICs and FEEs for the JUICE and JEO Missions

A family of science enabling radiation hard Application Specific Integrated Circuits (ASICs), Front End Electronics (FEEs) and Event Processing Systems, with flight heritage on many NASA missions, is presented. These technologies play an important role in the miniaturization of instruments -and spacecraft systems- at the same time increasing performance and reducing power. The technologies target time of flight, position sensing, and energy measurements as well as standard housekeeping and telemetry functions for particle and fields instruments, but find applications in other instrument categories too. More specifically the technologies include: the TOF chip, 1D and 2D Delay Lines with MCP detectors, for high precision fast and low power time of flight and position sensing; the Energy chip for multichannel SSD readout with time over threshold and standard voltage read out for TDC and ADC digitization; Fast multi channel read out chip with commandable thresholds; the TRIO chip for multiplexed ADC and housekeeping etc. It should be mentioned that the ASICs include basic trigger capabilities to enable random event processing in a heavy background of penetrators and UV foreground. Typical instruments include time of flight versus energy and look angle particle analyzers such as: plasma composition, energetic particle, neutral atom imaging as well as fast plasma and deltaE/E ion/electron telescopes. Flight missions include: Cassini/LEMMS, IMAGE/HENA, MESSENGER/EPPS/MLA/X-ray/MLA, STEREO, PLUTO-NH/PEPSSI/LORI, IBEX-Lo, JUNO/JEDI, RBSP/RBSPICE, MMS/HPCA/EPD, SO/SIS. Given the proven capability on heavy radiation missions such as JUNO, MMS and RBSB, as well diverse long duration missions such as MESSENGER, PLUTO and Cassini, it is expected that these technologies will play an important role in the particle and fields (at least) instruments on the upcoming JUICE and JEO missions.

Paschalidis, Nicholas↗

Error protection capability of space shuttle data bus designs

Error protection assurance in the reliability of digital data communications is discussed. The need for error protection on the space shuttle data bus system has been recognized and specified as a hardware requirement. The error protection techniques of particular concern are those designed into the Shuttle Main Engine Interface (MEI) and the Orbiter Multiplex Interface Adapter (MIA). The techniques and circuit design details proposed for these hardware are analyzed in this report to determine their error protection capability. The capability is calculated in terms of the probability of an undetected word error. Calculated results are reported for a noise environment that ranges from the nominal noise level stated in the hardware specifications to burst levels which may occur in extreme or anomalous conditions.

Proch, G. E.↗

Data acquisition from high-speed rotating shafts

Data system, when used with a rotary transformer, results in increased life, negligible noise, and capability for a large number of data channels in testing rotating equipment. It is used to multiplex many channels of analog transducer output data and convert this signal to binary digital output.

Lesco, D. J.↗

Command and Service Module Communications

This viewgraph presentation examines Command and Service Module (CSM) Communications. The communication system's capabilities are defined, including CSM-Earth, CSM-Lunar Module and CSM-Extravehicular crewman communications. An overview is provided for S-band communications, including data transmission and receiving rates, operating frequencies and major system components (pre-modulation processors, unified S-band electronics, S-band power amplifier and S-band antennas). Additionally, data transmission rates, operating frequencies and the capabilities of VHF communications are described. Major VHF components, including transmitters and receivers, and the VHF multiplexer and antennas are also highlighted. Finally, communications during pre-launch, ascent, in-flight and entry are discussed. Overall, the CSM communication system was rated highly by flight controllers and crew. The system was mostly autonomous for both crew and flight controllers and no major issues were encountered during flight.

Interbartolo, Michael↗

A temperature and pressure controlled calibration system for pressure sensors

A data acquisition and experiment control system capable of simulating temperatures from -184 to +220 C and pressures either absolute or differential from 0 to 344.74 kPa is developed to characterize silicon pressure sensor response to temperature and pressure. System software is described that includes sensor data acquisition, algorithms for numerically derived thermal offset and sensitivity correction, and operation of the environmental chamber and pressure standard. This system is shown to be capable of computer interfaced cryogenic testing to within 1 C and 34.47 Pa of single channel or multiplexed arrays of silicon pressure sensors.

Chapman, John J.↗

A Rapid Turnaround Cryogenic Detector Characterization System

Upcoming major NASA missions such as the Einstein Inflation Probe and the Single Aperture Far-Infrared Observatory require arrays of detectors with thousands of elements, operating at temperatures near l00 mK and sensitive to wavelengths from approx. 100 microns to approx. 3 mm. Such detectors represent a substantial enabling technology for these missions, and must be demonstrated soon in order for them to proceed. In order to make rapid progress on detector development, the cryogenic testing cycle must be made convenient and quick. We have developed a cryogenic detector characterization system capable of testing superconducting detector arrays in formats up to 8 x 32, read out by SQUID multiplexers. The system relies on the cooling of a two-stage adiabatic demagnetization refrigerator immersed in a liquid helium bath. This approach permits a detector to be cooled from 300K to 50 mK in about 4 hours, so that a test cycle begun in the morning will be over by the end of the day. Tine system is modular, with two identical immersible units, so that while one unit is cooling, the second can be reconfigured for the next battery of tests. We describe the design, construction, and performance of this cryogenic detector testing facility.

Benford, Dominic j.↗

Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister

Many atmospheric research aircraft use a standard canister design to mount instruments, as this significantly facilitates their electrical and mechanical integration and thereby reduces cost. Based on more than 30 years of airborne science experience with the Microwave Temperature Profiler (MTP), the MTP has been repackaged with state-of-the-art electronics and other design improvements to fly in one of these standard canisters. All of the controlling electronics are integrated on a single 4 ~5-in. (.10 ~13- cm) multi-layer PCB (printed circuit board) with surface-mount hardware. Improved circuit design, including a self-calibrating RTD (resistive temperature detector) multiplexer, was implemented in order to reduce the size and mass of the electronics while providing increased capability. A new microcontroller-based temperature controller board was designed, providing better control with fewer components. Five such boards are used to provide local control of the temperature in various areas of the instrument, improving radiometric performance. The new stepper motor has an embedded controller eliminating the need for a separate controller board. The reference target is heated to avoid possible emissivity (and hence calibration) changes due to moisture contamination in humid environments, as well as avoiding issues with ambient targets during ascent and descent. The radiometer is a double-sideband heterodyne receiver tuned sequentially to individual oxygen emission lines near 60 GHz, with the line selection and intermediate frequency bandwidths chosen to accommodate the altitude range of the aircraft and mission.

Mahoney, Michael J.↗

Multisensor Instrument for Real-Time Biological Monitoring

The figure schematically depicts an instrumentation system, called a fiber optic-based integration system (FOBIS), that is undergoing development to enable real-time monitoring of fluid cell cultures, bioprocess flows, and the like. The FOBIS design combines a micro flow cytometer (MFC), a microphotometer (MP), and a fluorescence-spectrum- or binding-force-measuring micro-sensor (MS) in a single instrument that is capable of measuring multiple biological parameters simultaneously or sequentially. The fiber-optic-based integration system is so named because the MFC, the MP, and the MS are integrated into a single optical system that is coupled to light sources and photometric equipment via optical fibers. The optical coupling components also include a wavelength-division multiplexer and diffractive optical elements. The FOBIS includes a laserdiode- and fiber-optic-based optical trapping subsystem (optical tweezers ) with microphotometric and micro-sensing capabilities for noninvasive confinement and optical measurement of relevant parameters of a single cell or other particle. Some of the measurement techniques implemented together by the FOBIS have long been used separately to obtain basic understanding of the optical properties of individual cells and other organisms, the optical properties of populations of organisms, and the interrelationships among these properties, physiology of the organisms, and physical processes that govern the media that surround the organisms. For example, flow cytometry yields information on numerical concentrations, cross-sectional areas, and types of cells or other particles. Micro-sensing can be used to measure pH and concentrations of oxygen, carbon dioxide, glucose, metabolites, calcium, and antigens in a cell-culture fluid, thereby providing feedback that can be helpful in improving control over a bioprocess. Microphotometry (including measurements of scattering and fluorescence) can yield further information about optically trapped individual particles. In addition to the multifunctionality not previously available in a single biological monitoring system, the FOBIS offers advantages of low mass, sensitivity, accuracy, portability, low cost, compactness (the overall dimensions of the fully developed FOBIS sensor head are expected to be less than 1 by 1 by 2 cm), and immunity to electromagnetic interference at suboptical frequencies. FOBIS could be useful in a variety of laboratory and field settings in such diverse endeavors as medical, veterinary, and general biological research; medical and veterinary diagnosis monitoring of industrial bioprocesses; and analysis of biological contaminants in air, water, and food.

Zhang, Sean (Zhanxiang)↗

RIMSTAR: Rapid image scanning technology and archiving

Conventional schemes for digitizing large volumes of photographic data are far too costly and time consuming to encourage the undertaking of the ambitious projects using traditional technology. There is a distinct need for fast digitizing systems such as could be derived from development of large format, optically multiplexed CCD systems designed to address these problems. The use of CCD chips for data handling and the capability of using polaroids in the optical path for reduced light scattering are discussed.

Craine, E. R.↗