Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexing readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a Robust, Efficient Process to Produce Scalable, Superconducting Kilopixel Far-IR Detector Arrays

The far-IR band is uniquely suited to study the physical conditions in the interstellar medium from nearby sources out to the highest redshifts. FIR imaging and spectroscopy instrumentation using incoherent superconducting bolometers represents a high sensitivity technology for many future suborbital and space missions, including the Origins Space Telescope. Robust, high sensitivity detector arrays with several 104 pixels, large focal plane filling factors, and low cosmic ray cross sections that operate over the entire far-IR regime are required for such missions. These arrays could consist of smaller sub-arrays, in case they are tileable. The TES based Backshort Under Grid array architecture which our group has fielded in a number of FIR cameras, is a good candidate to meet these requirements: BUGs are tileable, and with the integration of the SQUID multiplexer scaleable beyond wafer sizes; they provide high filling factors, low cosmic cross section and have been demonstrated successfully in far-infrared astronomical instrumentation. However, the production of BUGs with integrated readout multiplexers has many time and resource consuming process steps. In order to meet the requirement of robustness and efficiency on the production of future arrays, we have developed a new method to provide the superconducting connection of BUG detectors to the readout multiplexers or general readout boards behind the detectors. This approach should allow us to reach the goal to produce reliable, very large detector arrays for future FIR missions.

Staguhn, Johannes↗

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

SLAC microresonator RF(SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Here, we describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

47 OTHER INSTRUMENTATION↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

Design and Fabrication of Quantum Information Processing Devices (Final Report)

The goal of this work is to develop a wideband Josephson Parametric Amplifier (JPA) by the combination of a coplanar impedance transformer and a lumped Josephson Parametric Amplifier. Josephson Parametric Amplifiers take advantage of the nonlinear inductance of Josephson junctions and the nearly lossless superconductor circuits to achieve wave mixing and amplification with only quantum-limited added noise, which makes it a key component in quantum measurements, such as single-shot qubit measurement. However, the current JPAs generally have a relatively high quality factor and small bandwidth (around 50MHz to 100MHz), which limits their ability in measuring signals from a broad spectrum. Therefore, the work planned to use a coplanar impedance transformer to enhance the coupling between JPA and the signals, resulting in a small quality factor and large bandwidth. By decreasing the quality factor of JPA to around 3, one can achieve around 20dB gain within a bandwidth of several hundred MHz. Moreover, the wideband feature allows this device to explore the frequency dependence of the coupling between the JPA and the signals. Because the impedance transformer is based on a coplanar transmission line and requires no modifications of the lumped JPA, it is relatively straightforward to embed it in the current fabrication, package, and testing process for lumped JPA. The impedance transformer can be fabricated by liftoff or etching process with the lumped JPA together, which adds no fabrication complexity. The only difference is the size, which is around 3~5 times larger than lumped JPA. This may make the number of available chips on a single wafer lower. As for the public benefits, the development of this wideband JPA will make it possible to use just a single JPA device for multi-frequency signals, for example, the readout signals of a superconducting qubit chip with multiplexed readout bus. This would greatly decrease the demand for JPAs in quantum measurements.

42 ENGINEERING↗

Characterization of direct readout Si:Sb and Si:Ga infrared detector arrays for space-based astronomy

Preliminary test results from the evaluation of Si:Sb and Si:Ga 58 x 62-element infrared detector arrays are presented. These devices are being characterized under background conditions and readout rates representative of operation in orbiting, crogenically-cooled infrared observatories. The arrays are hybridized to silicon direct-readout multiplexers which allow random-access and nondestructive readout. Array performance optimization is being conducted with a flexible microcomputer-based drive and readoaut electronics system. Preliminary Si:Sb measurements indicate a sense node capacitance of 0.06 pF, peak (28-micron) responsivity above 3 A/W at 2V bias, read noise of 130 rms e(-), dark current approximately 10 e(-)/s, and a well capacity greater than 10 to the 5th e(-). The limited test data available on the performance of the Si:Ga array are also discussed.

Mckelvey, Mark E.↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Broadband bandpass Purcell filter for circuit quantum electrodynamics

In circuit quantum electrodynamics, qubits are typically measured using dispersively coupled readout resonators. Coupling between each readout resonator and its electrical environment, however, reduces the qubit lifetime via the Purcell effect. Inserting a Purcell filter counters this effect while maintaining high readout fidelity but reduces measurement bandwidth and, thus, limits multiplexing readout capacity. In this Letter, we develop and implement a multi-stage bandpass Purcell filter that yields better qubit protection while simultaneously increasing measurement bandwidth and multiplexed capacity. Here, we report on the experimental performance of our transmission-line-based implementation of this approach, a flexible design that can easily be integrated with current scaled-up, long coherence time superconducting quantum processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for X-ray astrophysics

Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including >200 pixels, of:1.95 eV for Ti-Ka(4.5 keV), 1.97eV for Mn-Ka(5.9 keV), 2.16 eV for Co-Kα(6.9 keV),2.33 eV for Cu-Kα(8 keV), 3.26 eV for Br-Kα(11.9 keV). The 1 sigma statistical errorsare£0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

S J Smith↗

256x256 switched-FET multiplexer for spaceborne astronomical applications

A novel cryogenic design of a source follower per detector (SFD) direct readout multiplexer is demonstrated. This design has proven to be a good prototype for the development of new low-noise large-area cryogenic multiplexers. In the absence of clocking noise, the readout demonstrates as low as about 30 electrons of rms read noise. There is still an excess noise component feeding through when the array is clocked, which manifests itself only at the lower temperatures. The shape of this component is dependent on a number of the bias voltages, and especially on the temperature of the chip. Analysis of the noise spectral density of the unit cell under various bias conditions shows that there is an excess spectral noise component at the lower temperatures.

Mcmurray, Robert E., Jr.↗

Characterization of Aliased Noise in the Advanced ACTPol Receiver

Advanced ACTPol is the second-generation polarization-sensitive upgrade to the 6m aperture Atacama Cosmology Telescope (ACT), which increased detector count and frequency coverage compared to the previous ACTPol receiver. Advanced ACTPol utilizes a new two-stage time-division multiplexing readout architecture based on superconducting quantum interference devices to achieve a multiplexing factor as high as 64 (rows), fielding a 2012 detector camera at 150/220 GHz and two 90/150 GHz cameras containing 1716 detectors each. In a time-domain system, aliasing introduces noise to the readout. Here in this work we present a figure of merit to measure this noise contribution and present measurements of the aliased noise fraction of the Advanced ACTPol receiver as deployed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic Detector Technology for Space Science Application

We review the current status of detector development at NASA's Goddard Space Flight Center and address future prospect for space science application. In particular, the IR detector capability and applicability to second generation SOFIA instrument will be discussed. We will examine areas such as 3-dimensional hybridization of large format bolometer arrays to readout multiplexers; advanced light coupling scheme for planar ortho-mode transducer circuitry; integration of high density readout wiring for low temperature detector arrays; and microwave multiplexers for large format superconducting detector arrays.

Ting-Wen, Hsieh↗

Development of a Crosstalk Suppression Algorithm for KID Readout

The GroundBIRD telescope aims to detect B-mode polarization of the cosmic microwave background radiation using the kinetic inductance detector array as a polarimeter. For the readout of the signal from detector array, we have developed a frequency division multiplexing readout system based on a digital down converter method. These techniques in general have the leakage problems caused by the crosstalks. The window function was applied in the field programmable gate arrays to mitigate the effect of these problems and tested it in algorithm level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-background direct readout array performance

The development and evaluation of an integrated array of antimony-doped silicon detectors is described. The spectral range of extrinsic silicon-integrated arrays useful for low-background IR astronomical applications is extended to about 31 microns with this development. The 58 x 62-element array is accessed by a direct readout multiplexer. The device is evaluated with a flexible microcomputer-based drive and readout electronics system in a low-background test dewar. Acceptance testing indicates single-pixel NEPs in the mid-10 to the -18th W/sq rt Hz range, and good global uniformity statistics.

Goebel, J. H.↗

A double photomultiplier Compton camera and its readout system for mice imaging

We have designed a Compton Camera (CC) to image the bio-distribution of gamma-emitting radiopharmaceuticals in mice. A CC employs the 'electronic collimation', i.e. a technique that traces the gamma-rays instead of selecting them with physical lead or tungsten collimators. To perform such a task, a CC measures the parameters of the Compton interaction that occurs in the device itself. At least two detectors are required: one (tracker), where the primary gamma undergoes a Compton interaction and a second one (calorimeter), in which the scattered gamma is completely absorbed. Eventually the polar angle and hence a 'cone' of possible incident directions are obtained (event with 'incomplete geometry'). Different solutions for the two detectors are proposed in the literature: our design foresees two similar Position Sensitive Photomultipliers (PMT, Hamamatsu H8500). Each PMT has 64 output channels that are reduced to 4 using a charge multiplexed readout system, i.e. a Series Charge Multiplexing net of resistors. Triggering of the system is provided by the coincidence of fast signals extracted at the last dynode of the PMTs. Assets are the low cost and the simplicity of design and operation, having just one type of device; among drawbacks there is a lower resolution with respect to more sophisticated trackers and full 64 channels Readout. This paper does compare our design of our two-Hamamatsu CC to other solutions and shows how the spatial and energy accuracy is suitable for the inspection of radioactivity in mice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗