Search NASA⌕ Search

SEARCH · Search NASA

Results for “nanosecond pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Nanosecond radar observations of the ocean surface from a stable platform

The measurement of ocean surface waves with a nanosecond radar pulse from a fixed platform at vertical incidence is discussed. By reducing the pulse width of radar until the pulse width resolves the vertical water wave structure, a set of radar returns is available to describe the ocean surface characteristics which differs from returns obtained by conventional radars. A block diagram of the radar and the principles of operation are presented.

Yaplee, B. S.↗

Stimulated Raman-scattering threshold behavior of binary mixture micrometer-sized droplets

Stimulated Raman scattering (SRS) from binary liquid mixture micrometer-sized droplets irradiated by nanosecond laser pulses exhibits previously unreported features. SRS emission at wavelength shifts corresponding to combination frequencies of the individual component Stokes shifts are observed in droplets but not in bulk mixtures. Furthermore, droplet SRS thresholds are determined by component refractive indices and concentrations, in contrast to bulk thresholds, for which self-focusing likely plays a dominant role.

Biswas, Abhijit↗

Ranging performance of satellite laser altimeters

Topographic mapping of the earth, moon and planets can be accomplished with high resolution and accuracy using satellite laser altimeters. These systems employ nanosecond laser pulses and microradian beam divergences to achieve submeter vertical range resolution from orbital altitudes of several hundred kilometers. Here, we develop detailed expressions for the range and pulse width measurement accuracies and use the results to evaluate the ranging performances of several satellite laser altimeters currently under development by NASA for launch during the next decade. Our analysis includes the effects of the target surface characteristics, spacecraft pointing jitter and waveform digitizer characteristics. The results show that ranging accuracy is critically dependent on the pointing accuracy and stability of the altimeter especially over high relief terrain where surface slopes are large. At typical orbital altitudes of several hundred kilometers, single-shot accuracies of a few centimeters can be achieved only when the pointing jitter is on the order of 10 mu rad or less.

Gardner, Chester S.↗

CHOMPTT (CubeSat Handling of Multisystem Precision Timing Transfer): From Concept to Launch Pad

Here we present the evolution of a student satellite mission: CHOMPTT (CubeSat Handling of Multisystem Precision Time Transfer), from its original concept as a candidate for the University NanoSatellite Program 8 (UNP8), to a spacecraft ready for launch in Fall of 2017 on ELaNa XIX (Educational Launch of Nanosatellites). The 3U CubeSat houses a 1 kg, 1U OPTI (Optical Precision Timing Instrument) payload, designed and built at the University of Florida, and a 1.5U EDSNNODeS-derived bus from NASA Ames Research Center. The OPTI payload comprises of: 1) a supervisor board that handles payload data, power regulation, and mode settings, 2) an optics assembly of six 1 cm retroreflectors and four laser beacon diodes for ground-tracking; and 3) two fully redundant timing channels, each consisting of: a chip-scale atomic clock, a microprocessor with clock counter, a picosecond event timer, and an avalanche photodetector (APD) with band-pass filter. Several iterations of OPTI have been developed, tested, and designed to achieve its current functionality and design a laboratory breadboard design, a 1.5U high altitude balloon design, engineering unit design, and its current flight unit design. In-lab testing of the current OPTI design indicates a short-term precision of 100 ps, equivalent to a range accuracy of 3 cm necessary to achieve our primary objective of 200 ps time transfer error, and a long-term timing accuracy of 20 ns over one orbit (1.5 hours). After the spacecraft reaches its nominal 500 km orbit at a 85 degree inclination, an experimental laser ranging facility at Kennedy Space Center in Florida, will track and emit 1064 nm nanosecond optical pulses at the CHOMPTT spacecraft. The laser pulses will then reflect off the retroreflector array mounted on the nadir face of CHOMPTT, and return the pulse to the laser ranging facility where the laser ranging facility will record the round-trip duration of the laser pulses. At the same time the pulse arrives at the spacecraft and is reflected by the array, an APD will record the arrival time of the pulses at the nanosatellite. By comparing the arrival of the pulse at the CubeSat and the duration of the round-trip of the laser pulse, the clock discrepancy between the ground and CubeSat atomic clocks can be determined, in addition to the CubeSats range from the facility. The design and verification of the flight version of CHOMPTT will be reviewed and an overview of the lifetime development and progression of CHOMPTT from the inception to launch pad will be presented.

CHOMPTT↗

Plasma Activated Water for Crewed Transit and Planetary Habitation: A Study of Gas Type, Electrode Material, and Power Supply Selection and the Impact on the Final Frontier - FY21 CIF

An in-depth study of plasma activated water (PAW) generation was conducted to link changes in power supply, electrode material, input gas, and treatment time to the resulting reaction chemistry. These changes in chemistry can help tailor PAW for different space applications. An AC, DC, and nanosecond (ns) pulsed power supply were each used to generate PAW with stainless steel, copper, tungsten, or platinum (Pt) electrodes while utilizing air, nitrogen (N2), carbon dioxide (CO2), helium (He), or argon (Ar) as the feed gas. Tap or deionized (DI) water was treated for 1 to 15 minutes, and the generated PAW was tested for changes in pH, conductivity, oxidation reduction potential, nitrates (NO3-), ammonium (NH4+), and peroxide. Calculations showed that the production of reactive nitrogen species was the leading cause of pH and conductivity changes. The DC generated air plasma was able to reduce the pH of DI water and generate NO3‑. The pulsed supply, operating at 20% of the input power of the DC supply, lowered the pH generated NO3‑. When a simulated Martian gas mixture of 95% CO2 and 5% N2 was used as the feed gas, NO3‑ was generated with the DC and pulsed supplies, respectively. Mixing PAW with plasma generated ash from inedible biomass allowed pH control, thus enhancing PAW’s potential use for sanitation applications. The large shift in pH was used to study sanitation effects of Escherichia coli (E. coli) reduction and Staphylococcus aureus (S. aureus), in which log reductions were found to be negligible. Additionally, the plasma generated ash in combination with PAW was also implemented in 10-day microgreen growth trials, in which PAW and ash resulted in quicker emergence of the microgreens compared to the standard growth conditions and comparable dry masses to Hoagland’s nutrient solution treated samples.

plasma activated water (PAW)↗

Laser technology for high precision satellite tracking

Fixed and mobile laser ranging stations have been developed to track satellites equipped with retro-reflector arrays. These have operated consistently at data rates of once per second with range precision better than 50 cm, using Q-switched ruby lasers with pulse durations of 20 to 40 nanoseconds. Improvements are being incorporated to improve the precision to 10 cm, and to permit ranging to more distant satellites. These include improved reflector array designs, processing and analysis of the received reflection pulses, and use of sub-nanosecond pulse duration lasers.

Plotkin, H. H.↗

Pulse stretcher for narrow pulses

Pulse stretching circuit can linearly stretch pulses as narrow as 50 nanoseconds and block incoming pulses following accepted input pulse until processing has been completed. It also removes baseline distortion by being completely direct coupled and provides monitor output which measures true number of input events that exceed predetermined threshold.

Lindsey, R. S., Jr.↗

Response of silicon solar cell to pulsed laser illumination

The response of silicon solar cell(s) to pulsed laser illumination is discussed. The motivation was due to the interest of Earth to space/Moon power beaming applications. When this work began, it was not known if solar cells would respond to laser light with pulse lengths in the nanosecond range and a repetition frequency in the kHz range. This is because the laser pulse would be shorter than the minority carrier lifetime of silicon. A 20-nanosecond (ns) full width half max (FWHM) pulse from an aluminum-gallium/arsenide (Al-Ga-As) diode laser was used to illuminate silicon solar cells at a wavelength of 885 nanometers (nm). Using a high-speed digital oscilloscope, the response of the solar cells to individual pulses across various resistive loads was observed and recorded.

Willowby, D.↗

Dye laser traveling wave amplifier

A flash lamp pumped dye laser suitable for use as an amplifier stage was developed. The desired output laser pulses are of nanosecond duration, tunable in center frequency, and of good optical quality. Its usefulness as a laser oscillator is emphasized, because it constitutes a compact, relatively efficient source of tunable dye laser light.

Davidson, F.↗

Measurement of temperature and density fluctuations in turbulence using an ultraviolet laser

Noninvasive measurement of density and temperature fluctuations in turbulent air flow was examined. The approach used fluorescence of oxygen molecules which are selectively excited by a tunable vacuum ultraviolet laser beam. The strength of the fluorescence signal and its dependence on laser wavelength vary with the density and temperature of the air in the laser beam. Because fluorescence can be detected at 90 degrees from the beam propagation direction, spatial resolution in three dimensions, rather than path-integrated measurements can be achieved. With spatial resolutions of the order of a millimeter and at supersonic air velocities it is necessary to perform each measurement in a time of the order of a microsecond; this is possible by by using laser pulses of ten nanosecond duration. In this method atmospheric O2 is excited by the emission of a tunable ArF excimer laser, and the fluorescence, which spans the 210 to 420 range, is detected by an ultraviolet phototube.

Massey, G. A.↗

Laser damage of HR, AR-coatings, monolayers and bare surfaces at 1064 nm

Laser induced damage thresholds and morphologies were investigated in a variety of uncoated and coated surfaces, including monolayers and multi-layers of different chemical compositions. Both antireflective (AR) and highly reflective (HR) were tested. Testing was done at 1064 nm with 25 picosecond and 8 nanosecond YAG/Nd laser single pulses. Spot diameter in the experiments varied from 0.09 to 0.22 mm. The laser damage measurement procedure consisted of 1-on-1 (single laser pulse in the selected site) and N-on-1 experiments including repeated irradiation by pulses of the same fluence and subsequently raised from pulse to pulse fluence until damage occurred. The highest picosecond damage thresholds of commercially available coatings averaged 12 - 14 J/sq cm, 50 percent less than thresholds obtained in bare fused silica. Some coatings and bare surfaces revealed a palpable preconditioning effect (an increase in threshold of 1.2 to 1.8 times). Picosecond and nanosecond data were compared to draw conclusions about pulse width dependence. An attempt was made to classify damage morphologies according to the type of coating, class of irradiating, and damage level.

Garnov, S. V.↗

Radar altimetry over sea ice

To study the sea-ice interactive region in the Bering and Greenland Seas a series of experimental compaigns, the Marginal Ice Zone Experiment (MIZEX) has been planned. A major objective of MIZEX is the development of a capability to relate the morphology and distribution of the sea ice to atmospheric and oceanographic parameters in an overall model. During the first part of the MIZEX, a 13.7 GHz microwave radar altimeter/scatterometer having a pulse length of 16 nanoseconds was flown over the Bering Sea Marginal ice zone. On the same aircraft were the NASA GSFC 19 GHz Electronically Scanning Microwave Radiometer (ESMR), scanning radiometers and an infrared, nadir pointing, temperature sounder. The altimeter/scatterometer was operated in nadir pointing and conically scanning modes to collect measurements of reflectivity and pulse shapes. These will be related to sea-ice classifications, ocean wave spectra and coincident microwave and infrared radiometric measurements and laser profilometer surface roughness estimates.

Powell, J.↗

Validity Using Pump-Probe Pulses to Determine the Optical Response of Niobate Crystals

A variety of niobate crystals have found their places in nonlinear optical applications as well as in laser devices. In recent years much attention has been paid to study the ultrafast optical response in a variety of photorefractive crystals such as KTa(1-x)Nb(x)O3 and KNbO3 crystals, glasses, semiconductors and polymers for applications in optical switching, information processing, optical computing, and all-optical device systems. Third-order optical nonlinearity is the most important property for realization of all-optical switching. Therefore experiments have been performed on the third order susceptibility using a variety of techniques such as the third-order harmonic generation, EFISH and degenerate four-wave mixing(DFWM). The latter has been conducted with a variety of pump wavelengths and with nanosecond, picosecond and femtosecond pulses. Niobate crystals, such as potassium niobate KNbO3, potassium tantalate niobate KTN family (KTa(1-x)Nb(x)O3), strontium barium niobate SBN (Sr(x)Ba(1-x)Nb2O6) and potassium-sodium niobate SBN (KNSBN) are attractive due to their photorefractive properties for application in optical storage and processing. The pulsed probe experiments performed on theses materials have suggested two types of time responses. These responses have been associated with an coherent response due to Chi(sup 3), and a long lived component due to excited state population. Recent study of DFWM on KNbO3 and KTN family reveals that the long lived component of those crystals depends on the crystal orientation. A slowly decaying signal is observable when the grating vector K(sub g) is not perpendicular to the C-axis of those photorefractive crystals', otherwise the optical response signal would be only a narrow coherent peak with FWHM equal to the cross-correlation width of the write beam pulses. Based on this understanding, we study the photodynamical process of a variety of niobate crystals using DFWM in a Kg perpindicular to C geometry with a ps-YAG: Nd laser operating at 532nm. However, the discrepancies in numerical estimations of Chi(sup 3) in these materials and other nonlinear optical media have resulted in a number of discussions. In order to better understand the photodynamical process of niobate crystals after an short pulse excitation we analyze the factors governing the coherent signal and present the DFWM spectra of niobate crystals.

Liu, Huimin↗

Vehicle Charging And Potential (VCAP)

The vehicle charging and potential (VCAP) payload includes a small electron accelerator capable of operating in a pulsed mode with firing pulses ranging from 600 nanoseconds to 107 seconds (100 milliamps at 1000 volts), a spherical retarding potential analyzer - Langmuir probe, and charge current probes. This instrumentation will support studies of beam plasma interactions and the electrical charging of the spacecraft. Active experiments may also be performed to investigate the fundamental processes of artificial aurora and ionospheric perturbations. In addition, by firing the beam up the geomagnetic field lines of force (away from the Earth) investigations of parallel electric field may be performed.

Roberts, W. T.↗

MLRS - A lunar/artificial satellite laser ranging facility at the McDonald Observatory

Experience from lunar and satellite laser ranging experiments carried out at McDonald Observatory has been used to design the McDonald Laser Ranging Station (MLRS). The MLRS is a dual-purpose installation designed to obtain observations from the LAGEOS satellite and lunar targets. The instruments used at the station include a telescope assembly 0.76 meters in diameter; a Q-switched doubled neodymium YAG laser with a pulse rate of three nanoseconds; and a GaAs photodetector with Fabry-Perot interferometric filter. A functional diagram of the system is provided. The operating parameters of the instruments are summarized in a table.

Shelus, P. J.↗

Vehicle Charging And Potential (VCAP)

The vehicle charging and potential (VCAP) payload includes a small electron accelerator capable of operating in a pulsed mode with firing pulses ranging from 600 nanoseconds to 107 seconds (100 milliamps at 1000 volts), a spherical retarding potential analyzer - Langmuir probe, and charge current probes. This instrumentation will support studies of beam plasma interactions and the electrical charging of the spacecraft. Active experiments may also be performed to investigate the fundamental processes of artificial aurora and ionospheric perturbations. In addition, by firing the beam up the geomagnetic field lines of force (away from the Earth) investigations of parallel electric field may be performed.

Roberts, B.↗