Search NASA⌕ Search

SEARCH · Search NASA

Results for “neuromuscular systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rhopalium development in Aurelia aurita ephyrae

Rhopalia of developing ephyrae were examined using the SEM and TEM at 24 h intervals following strobilation induction. Kinocilia are shorter in the ephyra stage than in polyps. A few ephyra-type kinocilia are found in rhopalia as early as 24 h after induction, before a distinct rhopalium is seen. By 72 h, the shorter kinocilia predominate and are almost as numerous as in ephyrae (120 h). Many of the kinocilia are associated with mechanoreceptor cells (MR) found in the rhopalia. These MR cells are compared to those reported for medusae. Although newly released ephyrae lack a touch plate, the MR cells in their rhopalia along with the statocyst and neuromuscular system apparently enable these organisms to detect and respond to gravity.

NASA Discipline Developmental Biology↗

Quantitative changes of GABA-immunoreactive cells in the hindlimb representation of the rat somatosensory cortex after 14-day hindlimb unloading by tail suspension

The present study was aimed at evaluating quantitatively gamma-aminobutyric acid (GABA) immunoreactivity in the hindlimb representation of the rat somatosensory cortex after 14 days of hindlimb unloading by tail suspension. A reduction in the number of GABA-immunoreactive cells with respect to the control animals was observed in layer Va and Vb. GABA-containing terminals were also reduced in the same layers, particularly those terminals surrounding the soma and apical dendrites of pyramidal cells in layer Vb. On the basis of previous morphological and behavioral studies of the neuromuscular system of hindlimb-suspended animals, it is suggested that the unloading due to hindlimb suspension alters afferent signaling and feedback information from intramuscular receptors to the cerebral cortex due to modifications in the reflex organization of hindlimb muscle groups. We propose that the reduction in immunoreactivity of local circuit GABAergic neurons and terminals is an expression of changes in their modulatory activity to compensate for the alterations in the afferent information.

Non-NASA Center↗

Structural interplay of anesthetics and paralytics on muscle nicotinic receptors

General anesthetics and neuromuscular blockers are used together during surgery to stabilize patients in an unconscious state. Anesthetics act mainly by potentiating inhibitory ion channels and inhibiting excitatory ion channels, with the net effect of dampening nervous system excitability. Neuromuscular blockers act by antagonizing nicotinic acetylcholine receptors at the motor endplate; these excitatory ligand-gated ion channels are also inhibited by general anesthetics. The mechanisms by which anesthetics and neuromuscular blockers inhibit nicotinic receptors are poorly understood but underlie safe and effective surgeries. Here we took a direct structural approach to define how a commonly used anesthetic and two neuromuscular blockers act on a muscle-type nicotinic receptor. We discover that the intravenous anesthetic etomidate binds at an intrasubunit site in the transmembrane domain and stabilizes a non-conducting, desensitized-like state of the channel. The depolarizing neuromuscular blocker succinylcholine also stabilizes a desensitized channel but does so through binding to the classical neurotransmitter site. Rocuronium binds in this same neurotransmitter site but locks the receptor in a resting, non-conducting state. Together, this study reveals a structural mechanism for how general anesthetics work on excitatory nicotinic receptors and further rationalizes clinical observations in how general anesthetics and neuromuscular blockers interact.

59 BASIC BIOLOGICAL SCIENCES↗

Exploratory Study for Continuous-time Parameter Estimation of Ankle Dynamics

Recently, a parallel pathway model to describe ankle dynamics was proposed. This model provides a relationship between ankle angle and net ankle torque as the sum of a linear and nonlinear contribution. A technique to identify parameters of this model in discrete-time has been developed. However, these parameters are a nonlinear combination of the continuous-time physiology, making insight into the underlying physiology impossible. The stable and accurate estimation of continuous-time parameters is critical for accurate disease modeling, clinical diagnosis, robotic control strategies, development of optimal exercise protocols for longterm space exploration, sports medicine, etc. This paper explores the development of a system identification technique to estimate the continuous-time parameters of ankle dynamics. The effectiveness of this approach is assessed via simulation of a continuous-time model of ankle dynamics with typical parameters found in clinical studies. The results show that although this technique improves estimates, it does not provide robust estimates of continuous-time parameters of ankle dynamics. Due to this we conclude that alternative modeling strategies and more advanced estimation techniques be considered for future work.

neuromuscular systems↗

Cardiovascular and sympathetic neural responses to handgrip and cold pressor stimuli in humans before, during and after spaceflight

Astronauts returning to Earth have reduced orthostatic tolerance and exercise capacity. Alterations in autonomic nervous system and neuromuscular function after spaceflight might contribute to this problem. In this study, we tested the hypothesis that exposure to microgravity impairs autonomic neural control of sympathetic outflow in response to peripheral afferent stimulation produced by handgrip and a cold pressor test in humans. We studied five astronauts approximately 72 and 23 days before, and on landing day after the 16 day Neurolab (STS-90) space shuttle mission, and four of the astronauts during flight (day 12 or 13). Heart rate, arterial pressure and peroneal muscle sympathetic nerve activity (MSNA) were recorded before and during static handgrip sustained to fatigue at 40 % of maximum voluntary contraction, followed by 2 min of circulatory arrest pre-, in- and post-flight. The cold pressor test was applied only before (five astronauts) and during flight (day 12 or 13, four astronauts). Mean (+/- S.E.M.) baseline heart rates and arterial pressures were similar among pre-, in- and post-flight measurements. At the same relative fatiguing force, the peak systolic pressure and mean arterial pressure during static handgrip were not different before, during and after spaceflight. The peak diastolic pressure tended to be higher post- than pre-flight (112 +/- 6 vs. 99 +/- 5 mmHg, P = 0.088). Contraction-induced rises in heart rate were similar pre-, in- and post-flight. MSNA was higher post-flight in all subjects before static handgrip (26 +/- 4 post- vs. 15 +/- 4 bursts min(-1) pre-flight, P = 0.017). Contraction-evoked peak MSNA responses were not different before, during, and after spaceflight (41 +/- 4, 38 +/- 5 and 46 +/- 6 bursts min(-1), all P > 0.05). MSNA during post-handgrip circulatory arrest was higher post- than pre- or in-flight (41 +/- 1 vs. 33 +/- 3 and 30 +/- 5 bursts min(-1), P = 0.038 and 0.036). Similarly, responses of MSNA and blood pressure to the cold pressor test were well maintained in-flight. We conclude that modulation of muscle sympathetic neural outflow by muscle metaboreceptors and skin nociceptors is preserved during short duration spaceflight.

NASA Discipline Neuroscience↗

Management of hypophosphatemia

The etiology, clinical presentation, and management of hypophosphatemia are reviewed. Phosphorus is a major intracellular anion and plays an important role in many biochemical pathways relating to normal physiologic functions. Approximately 60 to 90% of the 1 to 1.5 g of daily dietary phosphorus intake is absorbed, and of that amount, about two thirds is excreted in the urine. The overall incidence of hypophosphatemia is about 2 to 3% of all hospitalized patients. Factors associated with hypophosphatemia include phosphate-binding antacid therapy, nasogastric suction, liver disease, sepsis, alcoholism, and acidosis associated with diabetic ketoacidosis. Patients receiving parenteral nutrient solutions were also at higher risk for hypophosphatemia before the routine supplementation of these formulations with phosphate. Patients with hypophosphatemia may be asymptomatic or may experience weakness, malaise, anorexia, bone pain, and respiratory arrest. The major systems involved include the neuromuscular, hematologic, and skeletal systems. Phosphorus-containing products used to treat hypophosphatemia are a combination of monobasic and dibasic phosphate salts. Therefore, it is essential to calculate doses in millimoles rather than milligrams or milliequivalents to more accurately reflect the phosphorus concentration and to avoid potentially serious dosage errors. Normal daily requirements are readily maintained by dietary sources of phosphorus such as milk products or may be supplemented by phosphate-containing products administered orally or intravenously. Since phosphorus is a key factor in many organ systems, it is essential to monitor serum phosphorus concentrations in patients at risk for hypophosphatemia.

Review, Tutorial↗

Investigation of limb-sidestick dynamic interaction with roll control

A fixed-base simulation has been carried out to investigate and quantify limb/manipulator dynamics and interactions between the neuromuscular subsystem, force sensing sidestick configuration, high-gain command augmentation, and command filtering, and also to investigate possible relationships between these interactions and the roll ratchet phenomenon. The data obtained support the suggestion that the roll ratchet phenomenon is a closed-loop pilot-vehicle system interaction in which the pilot's neuromuscular system dynamics play a central role. Ratchet tendencies are shown to be most severe on force sensing sidestick manipulators with small stick deflections.

Johnston, D. E.↗

Design considerations of manipulator and feel system characteristics in roll tracking

A fixed-base simulation was performed to identify and quantify interactions between the pilot's hand/arm neuromuscular subsystem and such control system features of typical modern fighter aircraft roll rate command mechanizations as: (1) force versus displacement sensing side-stick type manipulator, (2) feel force/displacement gradient, (3) feel system versus command prefilter dynamic lag, and (4) flight control system effective time delay. The experiment encompassed some 48 manipulator/filter/aircraft configurations. Displacement side-stick experiment results are given and compared with the previous force sidestick experiment results. Attention is focused on control bandwidth, excitement (peaking) of the neuromuscular mode, feel force/displacement gradient effects, time delay effects, etc. Section 5 is devoted to experiments with a center-stick in which force versus displacement sensing, feel system lag, and command prefilter lag influences on tracking performance and pilot preference are investigated.

Johnston, Donald E.↗

Neuromuscular activation patterns during treadmill walking after space flight

Astronauts adopt a variety of neuromuscular control strategies during space flight that are appropriate for locomoting in that unique environment, but are less than optimal upon return to Earth. We report here the first systematic investigation of potential adaptations in neuromuscular activity patterns associated with postflight locomotion. Astronaut-subjects were tasked with walking on a treadmill at 6.4 km/h while fixating a visual target 30 cm away from their eyes after space flights of 8-15 days. Surface electromyography was collected from selected lower limb muscles and normalized with regard to mean amplitude and temporal relation to heel strike. In general, high correlations (more than 0.80) were found between preflight and postflight activation waveforms for each muscle and each subject: however relative activation amplitude around heel strike and toe off was changed as a result of flight. The level of muscle cocontraction and activation variability, and the relationship between the phasic characteristics of the ankle musculature in preparation for toe off also were altered by space flight. Subjects also reported oscillopsia during treadmill walking after flight. These findings indicate that, after space flight, the sensory-motor system can generate neuromuscular-activation strategies that permit treadmill walking, but subtle changes in lower-limb neuromuscular activation are present that may contribute to increased lower limb kinematic variability and oscillopsia also present during postflight walking.

Flight Experiment↗

Materials dispersion and biodynamics project research

The Materials Dispersion and Biodynamics Project (MDBP) focuses on dispersion and mixing of various biological materials and the dynamics of cell-to-cell communication and intracellular molecular trafficking in microgravity. Research activities encompass biomedical applications, basic cell biology, biotechnology (products from cells), protein crystal development, ecological life support systems (involving algae and bacteria), drug delivery (microencapsulation), biofilm deposition by living organisms, and hardware development to support living cells on Space Station Freedom (SSF). Project goals are to expand the existing microgravity science database through experiments on sounding rockets, the Shuttle, and COMET program orbiters and to evolve,through current database acquisition and feasibility testing, to more mature and larger-scale commercial operations on SSF. Maximized utilization of SSF for these science applications will mean that service companies will have a role in providing equipment for use by a number of different customers. An example of a potential forerunner of such a service for SSF is the Materials Dispersion Apparatus (MDA) 'mini lab' of Instrumentation Technology Associates, Inc. (ITA) in use on the Shuttle for the Commercial MDAITA Experiments (CMIX) Project. The MDA wells provide the capability for a number of investigators to perform mixing and bioprocessing experiments in space. In the area of human adaptation to microgravity, a significant database has been obtained over the past three decades. Some low-g effects are similar to Earth-based disorders (anemia, osteoporosis, neuromuscular diseases, and immune system disorders). As new information targets potential profit-making processes, services and products from microgravity, commercial space ventures are expected to expand accordingly. Cooperative CCDS research in the above mentioned areas is essential for maturing SSF biotechnology and to ensure U.S. leadership in space technology. Currently, the MDBP conducts collaborative research with investigators at the Rockefeller University, National Cancer Institute, and the Universities of California, Arizona, and Alabama in Birmingham. The growing database from these collaborations provides fundamental information applicable to development of cell products, manipulation of immune cell response, bone cell growth and mineralization, and other processes altered by low-gravity. Contacts with biotechnology and biopharmaceutical companies are being increased to reach uninformed potential SSF users, provide access through the CMDS to interested users for feasibility studies, and to continue active involvement of current participants. We encourage and actively seek participation of private sector companies, and university and government researchers interested in biopharmaceuticals, hardware development and fundamental research in microgravity.

Lewis, Marian L.↗

Vestibulospinal reflexes as a function of microgravity

Data from previous manned space flights suggest that an exposure to microgravity produces significant alterations in vestibular, neuromuscular, and related sensory system functions. It is possible that the observed changes are a function of adaptation induced by altered otolith input. An experiment in Spacelab 1 was conducted with the aim to study this adaptation as it occurred in flight and after flight, and to relate the observed changes to mechanisms underlying space motion sickness. The concept was explored by making use of the anatomic pathway which links the otolith organs and spinal motoneurons. The overall sensitivity of the spinal motoneurons was tested by two related methods. One method involves the electrical excitation of neural tissue and the recording of vestibulospinal reflexes in conjunction with a brief linear acceleration. The second method is concerned with measurements of dynamic postural ataxia. Results suggest that more than a single time constant may be involved in man's ability to return to baseline values.

Reschke, M. F.↗

Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

Spiering, Barry A.↗

Stimulated single fiber electromyography in the mouse: techniques and normative data

As the number of new transgenic mouse models of human neuromuscular disease continues to increase, the development of sophisticated electrophysiologic techniques for assessing the peripheral nervous system in these models has become important. Neuromuscular junction (NMJ) dysfunction, in particular, is often not detectable by morphologic or other techniques. To enable sensitive testing of murine NMJ function, we developed and tested a method for stimulated single fiber electromyography (S-SFEMG) in the gastrocnemius muscles of anesthetized mice. Jitter was assessed by measuring the mean consecutive latency difference (MCD) of single fiber responses to sciatic nerve stimulation at 2 HZ. Mean MCD values in normothermic mice were in the range of 6-8 micros for different strains, with no MCD values exceeding 25 micros. Reduced core temperature (to 29 degrees--30 degrees C) resulted in increased jitter, whereas intubation and mechanical ventilation of mice did not alter these values. Intraperitoneal and intravenous injection of vecuronium, however, resulted in progressively increased jitter followed by blocking in continuously monitored fibers. These observations validate the utility of S-SFEMG in mice as an index of NMJ function under a variety of physiologic conditions, and suggest that a high safety factor for neuromuscular transmission exists at mouse NMJs. Copyright 2001 John Wiley & Sons, Inc.

Non-NASA Center↗

Automated quantitative muscle biopsy analysis system

An automated system to aid the diagnosis of neuromuscular diseases by producing fiber size histograms utilizing histochemically stained muscle biopsy tissue. Televised images of the microscopic fibers are processed electronically by a multi-microprocessor computer, which isolates, measures, and classifies the fibers and displays the fiber size distribution. The architecture of the multi-microprocessor computer, which is iterated to any required degree of complexity, features a series of individual microprocessors P.sub.n each receiving data from a shared memory M.sub.n-1 and outputing processed data to a separate shared memory M.sub.n+1 under control of a program stored in dedicated memory M.sub.n.

Castleman, Kenneth R.↗

Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (p<0.05). Bench press total work was also significantly impaired, although maximal isometric force and power were not significantly affected. No changes were noted for measurements of central activation or force steadiness. Results for ISS crew were not analyzed due to the current small sample size. DISCUSSION: Significant reductions in lower body muscle performance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

Ryder, Jeffrey W.↗

Effects of Spaceflight on Drosophila Neural Development

The major goal from the animal side, however, has been achieved, namely to develop Drosophila lines where we can assay individual neuromuscular endings directly without dissection. This was achieved by means of using the GAL4-UAS system, where we have succeeded in establishing stocks of flies where the key neuromuscular connections can be assayed directly in undissected larvae by means of the expression of endogenously fluorescent reporters in the specific motor endings. The green fluorescent protein (GFP) as a reporter allows scoring of neural anatomy en-masse in whole mount using fluorescent microscopy without the need for either dissection or specific labeling. Two stocks have been developed. The first, which we developed first, uses the S65T mutant form, which has a dramatically brighter expression than the native protein. This animal will use GAL4 drivers with expression under the control of the elav gene, and which will ensure expression in all neurons of the embryo and larva. The second transgenic animal we have developed is of a novel kind, and makes use of dicistronic design, so that two copies of the protein will be expressed per insert. We have also developed a tricistronic form, but this has not yet been transformed into flies, and we do not imagine that this third line will be ready in time for the flight.

Keshishian, Haig S.↗

Investigation of interactions between limb-manipulator dynamics and effective vehicle roll control characteristics

A fixed-base simulation was performed to identify and quantify interactions between the pilot's hand/arm neuromuscular subsystem and such features of typical modern fighter aircraft roll rate command control system mechanization as: (1) force sensing side-stick type manipulator; (2) vehicle effective role time constant; and (3) flight control system effective time delay. The simulation results provide insight to high frequency pilot induced oscillations (PIO) (roll ratchet), low frequency PIO, and roll-to-right control and handling problems previously observed in experimental and production fly-by-wire control systems. The simulation configurations encompass and/or duplicate actual flight situations, reproduce control problems observed in flight, and validate the concept that the high frequency nuisance mode known as roll ratchet derives primarily from the pilot's neuromuscular subsystem. The simulations show that force-sensing side-stick manipulator force/displacement/command gradients, command prefilters, and flight control system time delays need to be carefully adjusted to minimize neuromuscular mode amplitude peaking (roll ratchet tendency) without restricting roll control bandwidth (with resulting sluggish or PIO prone control).

Johnston, D. E.↗

Investigation of limb-sidestick dynamic interaction with roll control

A fixed-base simulation was performed to identify and quantify interactions between the pilot's hand/arm neuromuscular subsystem and such features of typical modern fighter aircraft roll rate command control system mechanization as: (1) force sensing side-stick type manipulator; (2) vehicle effective roll time constant; and (3) flight control system effective time delay. The simulation results provide insight to high frequency pilot induced oscillations (PIO) (roll ratchet), low frequency PIO, and roll-to-right control and handling problems previously observed in experimental and production fly-by-wire control systems. The simulation configurations encompass and/or duplicate several actual flight situations, reproduce control problems observed in flight, and validate the concept that the high frequency nuisance mode known as roll ratchet derives primarily from the pilot's neuromuscular subsystem. The simulations show that force-sensing side-stick manipulator force/displacement/command gradients, command prefilters, and flight control system time delays need to be carefully adjusted to minimize neuromuscular mode amplitude peaking (roll ratchet tendency) without restricting roll control bandwidth (with resulting sluggish or PIO prone control).

Johnston, D. E.↗