Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron capture cross section”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Aqueous harvesting of 88 Zr at a radioactive-ion-beam facility for cross-section measurements

Isotope harvesting is a method of collecting the long-lived radioisotopes that build up during the operation of ion-beam facilities in a way that is useful for subsequent research. As a demonstration of this method for the collection of a group IV metal at a fragmentation facility, the high-energy Zr 88 secondary beam produced from a 140-MeV/u Mo 92 primary beam at the National Superconducting Cyclotron Laboratory (NSCL) was stopped in a water target. The setup aimed to mimic the aqueous beam dump that will be implemented at the Facility for Rare Isotope Beams (FRIB). The collected Zr 88 and accompanying Y 88 decay daughter were radiochemically extracted from the solution and made into target samples suitable for neutron-capture cross-section measurements. These samples were then irradiated at two reactor facilities, and the Zr 88 average thermal-neutron-capture cross section ( σ T ) and resonance integral ( I ) were determined to be σ T = ( 8.04 ± 0.63 ) × 10 5 b and I = ( 2.53 ± 0.28 ) × 10 6 b. The σ T value agrees well with previous results and I , determined for the first time here, was found to be the largest measured resonance integral by two orders of magnitude. The Y 88 thermal-neutron-capture cross section was determined to be less than 1.8 × 10 4 b. This work demonstrates the steps needed to make cross-section measurements with samples produced via aqueous isotope harvesting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Improved $^{95}\mathrm{Mo}$ neutron resonance parameters and astrophysical reaction rates

We report improved 95 Mo neutron resonance parameters and reaction rates are important for nuclear astrophysics, testing nuclear models, and nuclear criticality safety. However, despite many previous neutron-capture and total cross-section measurements on this nuclide, there still is much room for improvement as well as several discrepancies. For example, there are very few firm resonance spin and parity assignments; average resonance parameters are available only for each parity, the currently recommended astrophysical reaction rate results in disagreements between stellar models and meteoric isotopic anomalies, and there are substantial disagreements in the neutron-capture cross section at low energies important for nuclear criticality safety. To obtain an improved set of neutron resonance parameters and astrophysical reaction rates for 95 Mo. High-resolution neutron-capture and transmission data were measured at the Oak Ridge Electron Linear Accelerator (ORELA) using highly isotopically enriched 95 Mo samples. The neutron-capture apparatus, data reduction, and analysis were improved so that information contained in the γ-ray cascade following neutron capture were used to assign resonance J π values. Following this, simultaneous analysis of the new neutron-capture and transmission data was used to obtain resonance energies, gamma widths, and neutron widths and their uncertainties to a maximum energy of 10 keV. Accurate neutron-capture cross sections also were obtained for the unresolved resonance region to a maximum energy of 500 keV and, together with the new resonance parameters, used to calculate the astrophysical reaction rates in the temperature range from 5 to 30 keV. A vastly improved set of 95Mo neutron resonance parameters and an astrophysical reaction rate accurate to about 3% were obtained. Firm J π assignments were determined for 261 of the 314 observed resonances. This is a very large improvement over the previously published 32 firm J π assignments for 108 resonances. Also, the number of resonances having both firm J π assignments and Γ γ values was increased by almost a factor of 24—from 11 to 261. Neutron- and total-radiation-width distributions and average resonance spacings, average total radiation widths, and neutron strength functions were obtained for the six different s- and p-wave possibilities. Parameters for the lowest s-wave resonance, which is most important for criticality benchmarks, were obtained with high accuracy. Simple modification of the neutron-capture apparatus and expansion and improvement of data analysis techniques led to a large increase in firm J π assignments for 95 Mo neutron resonances. The resulting astrophysical reaction rate is 20%–30% larger than the currently recommended rate at s-process temperatures, which should lead to better agreement between stellar models and meteoric isotopic anomalies. The neutron-capture cross section at low energies is substantially larger than recommended in the latest evaluation, which is problematical for criticality benchmarks. The average resonance spacing as a function of spin and parity is significantly different from current models. The total-radiation-width distributions are significantly broader than predicted by theory and show significant departures from the expected Gaussian shapes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Neutron-Induced Capture-to-Fission Cross Section Ratio in 233 U at LANSCE [Slides]

This presentation finds that new measurement at LANSCE combining DANCE and NEUANCE at the end of 2020 and 2021. Additionally, two samples of 10 mg and 20 mg of 233 U have been prepared at LANL by Evelyn M. Bond (December 2020). Data analysis has been finished and results of the capture-to-fission ratio on 233 U in the neutron energy region from 0.7 eV to 250 keV have been provided. The focus was to provide data from 1-300 keV. We are providing data from 0.7 eV to 1 keV in addition. The result has been normalized to the ENDF/B-VIII.0 broadened capture-to-fission cross section ratio in the neutron energy region recommended by the Luiz Leal and Marco Pigni, between 8.1 and 14.7 eV. This is the first measurement of the capture-to-fission ratio between 2 - 30 keV. The data show some small differences in the RRR with the evaluation though the general trend is consistent. In the URR this data shows a smaller capture-to-fission ratio than the evaluation from 10 to 150 keV

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of 10 B to convert epithermal neutrons into detectable α and 7 Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 μm boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV–500 keV epithermal energy range. For a 10 cm 2 active area, the detector achieves sensitivity to H 2 O weight fractions as low as 0.01 wt% in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

Detector modelling and simulations I (interaction ↗

Templates of expected measurement uncertainties for neutron-induced capture and charged-particle production cross section observables

This paper provides a template of expected uncertainties and correlations for measurements of neutron-induced capture and charged-particle production cross sections. Measurements performed in-beam include total absorption spectroscopy, total energy detection, γ -ray spectroscopy, and direct charged-particle detection. Offline measurements include activation analysis and accelerator mass spectrometry. The information needed for proper use of the datasets in resonance region and high energy region evaluations is described, and recommended uncertainties are provided when specific values are not available for a dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Complete set of bound negative-parity states in the neutron-rich nucleus 18 N

High-resolution γ -ray spectroscopy of N 18 is performed with the Advanced GAmma Tracking Array, following deep-inelastic processes induced by an O 18 beam on a Ta 181 target. Six states are newly identified, which together with the three known excitations exhaust all negative-parity excited states expected in N 18 below the neutron threshold. Spin and parities are proposed for all located states on the basis of decay branchings and comparison with large-scale shell-model calculations performed in the p-sd space, with the YSOX interaction. Of particular interest is the location of the 0 1 - and 1 2 - excitations, which provide strong constrains for cross-shell p-sd matrix elements based on realistic interactions and help to simultaneously reproduce the ground and first-excited states in N 16 and N 18 , for the first time. Overall, understanding the N 18 structure may also have significant impact on neutron-capture cross-section calculations in r-process modeling including light neutron-rich nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates and Validation for the n+ 63,65 Cu Cross Sections [Abstract]

The neutron induced total, elastic, and capture cross sections of 63,65 Cu isotopes were selected for evaluation in the resolved and unresolved resonance energy ranges by the National Criticality Safety Program to resolve discrepancies related to benchmark performance. This is especially evident for the series of ZEUS benchmarks in which copper is used as a reflector. Because copper is also used as structural material in both fission and fusion reactors, the need to address benchmark discrepancies linked to nuclear data deficiencies is a task of primary importance. The aim of this work is to describe the steps of evaluation work towards a consistent improvement of the benchmark performance. The R-matrix analysis with the SAMMY code focused on the 63 Cu(n,γ) reaction channel between 100-300 keV coupled to unresolved resonance region parameters up to 650 keV to fit average cross section data from a recent experiment. Due to the high sensitivity of many benchmarks to elastic scattering angular distribution data, especially for the 65 Cu isotope, the impact of these data was tested by generating Legendre coefficients from both resonance parameters and the Hauser-Feshbach model. Guided by the findings of Shaw et al., the performance of the current evaluation for 65 Cu was compared to that of ENDF/B-VII.1 and ENDF/B-VIII.0 by testing the reactivity coefficients corresponding to the validation suite of experimental criticality benchmarks for thermal, intermediate, and fast systems taken from the International Criticality Safety Benchmark Experiments Project Handbook. The benchmark performance is especially sensitive to 63 Cu(n,γ) and 65 Cu elastic scattering for neutron energies in the 100–500 keV region, whereas 100 keV is the upper limit of the resolved resonance region in the ENDF/B-VIII.0 evaluations for 63,65 Cu. The results highlight the need to handle the transition from the resolved resonance region to the high energy region carefully.

07 ISOTOPE AND RADIATION SOURCES↗

Zirconium Nuclear Data Campaign: Measurement of 90 Zr ( n, γ ) Cross Section

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σ γ /σ t ratio at most neutron energies. Thus, they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σ γ , of Zr isotopes. The ENDF/B VIII.0 library has a relative uncertainty of approximately 10–20% for incident neutron energies < 0.1 MeV and an uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program to embark on a campaign to accurately measure and evaluate these Zr isotopes. In this work, we demonstrate energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr.

07 ISOTOPE AND RADIATION SOURCES↗

Direct thermal neutron detection by the 2D semiconductor 6 LiInP 2 Se 6

Highly efficient neutron detectors are critical in many sectors, including national security, medicine, crystallography and astronomy. The main neutron detection technologies currently used involve 3 He-gas-filled proportional counters and light scintillators for thermalized neutrons. Semiconductors could provide the next generation of neutron detectors because their advantages could make them competitive with or superior to existing detectors. In particular, solids with a high concentration of high-neutron-capture nuclides (such as 6 Li, 10 B) could be used to develop smaller detectors with high intrinsic efficiencies. However, no promising materials have been reported so far for the construction of direct-conversion semiconductor detectors. Here we report on the semiconductor LiInP 2 Se 6 and demonstrate its potential as a candidate material for the direct detection of thermal neutrons at room temperature. This compound has a good thermal-neutron-capture cross-section, a suitable bandgap (2.06 electronvolts) and a favourable electronic band structure for efficient electron charge transport. We used α particles from an 241 Am source as a proxy for the neutron-capture reaction and determined that the compact two-dimensional (2D) LiInP 2 Se 6 detectors resolved the full-energy peak with an energy resolution of 13.9 per cent. Direct neutron detection from a moderated Pu–Be source was achieved using 6 Li-enriched (95 per cent) LiInP 2 Se 6 detectors with full-peak resolution. Here, we anticipate that these results will spark interest in this field and enable the replacement of 3 He counters by semiconductor-based neutron detectors.

36 MATERIALS SCIENCE↗

ORNL Neutron Cross Section Measurements of 90 Zr

Nuclear criticality modeling and simulations rely on the quality of the existing evaluated nuclear data libraries such as Evaluated Nuclear Data File (ENDF)/B, the Joint Evaluated Fission and Fusion (JEFF) nuclear data library, or the Japanese Evaluated Nuclear Data Library (JENDL). In some cases, the cross-section evaluations of those libraries were found to be deficient in describing criticality benchmarks accurately. More than two decades ago, the US Nuclear Criticality Safety Program (NCSP) established a Nuclear Data (ND) task which encompassed experiments and evaluations. In response to this, the Oak Ridge National Laboratory (ORNL) formed a Nuclear Criticality and Data group which performed ND experiments, data analysis, and evaluations to produce ENDF files for the ND libraries as identified in the NCSP Five-Year Plan. Before being submitted to the ENDF library, files were processed and tested for performance by running benchmark calculations. This procedure was centralized in the ORNL group and is now often referred to as the ND pipeline. NCSP collaborates with the Joint Research Center (JRC) of the European Commission in Geel, Belgium, to perform high-resolution neutron-induced cross section measurements at the Geel Linear Accelerator (GELINA). The objective is to address emerging ND problems in criticality calculations. Difficulties with ND include insufficient neutron energy range, missing covariances, and previously unrecognized inaccuracies with experiments. New neutron total and capture cross sections of 90 Zr in the neutron energy range from 100 eV to several hundred keV were recently performed. These measured data will be used, together with existing high-resolution transmission data from a metallic 90 Zr sample, to improve representation of the cross sections.

97 MATHEMATICS AND COMPUTING↗

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental uncertainty quantification using templates of expected measurement uncertainties for fast neutron-induced total, capture, and scattering cross sections

Careful experimental uncertainty quantification (UQ) is key for developing trustworthy evaluated nuclear data. Templates to account for missing or under-reported experimental uncertainties were recently developed by the covariance committee of Cross Section Evaluation Working Group (CSEWG). In this work, we illustrate the practical application and limitations of these templates for selected neutron-induced reactions, including (n, tot), (n, γ), and (n, xn) in the fast energy range, to illustrate their use in data analyses for nuclear data evaluations. We show that while the templates provide consistent framework, proper implementation still requires detailed knowledge of experimental conditions and careful treatment of nonlinear effects in cross section derivation. Case studies highlight how template-assisted UQ improves consistency with previous evaluations such as ENDF/B and reveals open challenges in propagating uncertainties across different energy regimes. The main contribution of this paper is to connect formal template recommendations with their use in practical evaluation workflows, clarifying both their benefits and current limitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron transfer reactions on the ground state and isomeric state of a 130 Sn beam

The structure of nuclei around the neutron-rich nucleus 132 Sn is of particular interest due to the vicinity of the Z = 50 and N = 82 shell closures and the r-process nucleosynthetic path. Four states in 131 Sn with a strong single-particle-like component have previously been studied via the (d,p) reaction, with limited excitation energy resolution. Here, the 130 Sn( 9 Be, 8 Be) 131 Sn and 130 Sn( 13 C, 12 C) 131 Sn single-neutron transfer reactions were performed in inverse kinematics at the Holifield Radioactive Ion Beam Facility using particle-γ coincidence spectroscopy. The uncertainties in the energies of the single-particle-like states have been reduced by more than an order of magnitude using the energies of γ rays. The previous tentative J π values have been confirmed. Decays from high-spin states in 131 Sn have been observed following transfer on the isomeric component of the 130 Sn beam. The improved energies and confirmed spin-parities of the p-wave states important to the r-process lead to direct-semidirect cross-sections for neutron capture on the ground state of 130 Sn at 30 keV that are in agreement with previous analyses. A similar assessment of the impact of neutron-transfer on the isomer would require significant nuclear structure and reaction theory input. There are few measurements of transfer reaction on isomers, and this is the first on an isomer in the 132 Sn region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Zr Nuclear Data Campaign: Measurement of (n,γ) cross section of 90,91 Zr [Abstract]

The isotopes of Zr with mass number A = [90; 91; 92; 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications due to their desirable mechanical and nuclear properties. For example, the zirconium alloys are used as cladding material in nuclear reactors. In addition to the mechanical properties, Zr-90 has a closed neutron shell, hence the capture cross sections of the zirconium isotopes are relatively small, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σ γ (E), of Zr isotopes. For incident neutron energies < 0.1 MeV, the ENDF library reports a relative uncertainty of approximately 20% and uncertainty greater than 20% above this energy. This motivates the Nuclear Criticality Safety Program (NCSP) to perform new neutron induced cross section measurements to accurately evaluate these four isotopes of Zr.

ENDF↗