Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NASA Tech Briefs, August 2008

Customizable Digital Receivers for Radar Two-Camera Acquisition and Tracking of a Flying Target Visual Data Analysis for Satellites A Data Type for Efficient Representation of Other Data Types Hand-Held Ultrasonic Instrument for Reading Matrix Symbols Broadband Microstrip-to-Coplanar Strip Double-Y Balun A Topographical Lidar System for Terrain-Relative Navigation Programmable Low-Voltage Circuit Breaker and Tester Electronic Switch Arrays for Managing Microbattery Arrays Topics covered include: Lower-Dark-Current, Higher-Blue-Response CMOS Imagers; Fabricating Large-Area Sheets of Single-Layer Graphene by CVD; Support for Diagnosis of Custom Computer Hardware; Providing Goal-Based Autonomy for Commanding a Spacecraft; Dynamic Method for Identifying Collected Sample Mass; Optimal Planning and Problem-Solving; Attitude-Control Algorithm for Minimizing Maneuver Execution Errors; Grants Document-Generation System; Heat-Storage Modules Containing LiNO3 3H2O and Graphite Foam; Precipitation-Strengthened, High-Temperature, High-Force Shape Memory Alloys; Improved Relief Valve Would Be Less Susceptible to Failure; Safety Modification of Cam-and-Groove Hose Coupling; Using Composite Materials in a Cryogenic Pump; Using Electronic Noses to Detect Tumors During Neurosurgery; Producing Newborn Synchronous Mammalian Cells; Smaller, Lower-Power Fast-Neutron Scintillation Detectors; Rotationally Vibrating Electric-Field Mill; Estimating Hardness from the USDC Tool-Bit Temperature Rise; Particle-Charge Spectrometer; Automated Production of Movies on a Cluster of Computers; FIDO-Class Development Rover; and Tone-Based Command of Deep Space Probes Using Ground Antennas.

Source record↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative analysis of new crystal and plastic scintillators for fast and thermal neutron detection

This paper considers scintillation and physical properties of efficient organic scintillators tested as single crystals and as components of plastics with pulse shape discrimination (PSD). For the first time, single crystals of 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) were grown for studies of the basic scintillation properties of this new compound. Comparison to classical organic crystals, like anthracene, trans-stilbene, and p-terphenyl, and to more recently introduced organic glass showed that the new crystal belongs to a group of the most efficient scintillators, with light output exceeding that of trans-stilbene and PSD comparable to that of p-terphenyl. Furthermore, additional studies were conducted to evaluate scintillation performance and physical properties, like hardness and dye leaching, of plastic scintillators prepared with PhF, organic glass, and liquid diisopropylnaphthalene (DIPN) that were considered as examples for potential replacement of PPO (2,5-diphenyloxazole) in current commercial PSD plastic scintillators. Comparison of the highest performing plastic scintillators prepared with these dyes shows that PhF formulations produced a record light output (LO) increase of 69 % relative to EJ-200. Similar improvements obtained with 6 Li-loaded formulations showed that future development of PSD plastics should not be limited to use of PPO but must involve the search and exploration of new efficient dyes that may lead to discovery of much brighter organic scintillators with improved physical properties required for fast and thermal neutron detection, fast neutron spectroscopy, and antineutrino detection applications.

9,9-dimethyl-2-phenyl-9H-fluorene↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗

Prompt-fission-neutron spectra in the 239 Pu( n,f ) reaction

Prompt-fission-neutron spectra from Pu 239 ( n , f ) were measured with respect to Cf 252 spontaneous fission for incident neutron energies from 0.7 to 700 MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center. A newly designed high-efficiency fission chamber was coupled to the highly segmented Chi-Nu neutron liquid scintillator array to detect neutrons emitted in fission events. The double time-of-flight technique was used to deduce the incident neutron energies from the spallation target and the outgoing-neutron energies from the fission chamber. Prompt-fission-neutron spectra (PFNS) were measured with respect to Cf 252 spontaneous fission down to 200 keV and up to about 12 MeV for all the incident neutron energies with typical total uncertainties well below 2 % up to about 7-MeV outgoing-neutron energy. The general trend of PFNS is well reproduced by JEFF3.3 and ENDF evaluations, although a better agreement is found with JEFF3.3. Discrepancies were observed for the low-energy part of the spectra, especially around the opening of the second-, third- and fourth-chance fission. Additionally, neutron average kinetic energies as a function of incident neutron energy are obtained experimentally with reported total uncertainties below 0.5 % . The measured values agree with the most recent data. The trend is fairly well reproduced by the JEFF3.3 evaluation, although it fails to reproduce the experimental values within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal growth, scintillation properties & fast neutron-gamma discrimination of cubic halide perovskite CsCaCl 3 :(Eu 2+ , Tl + )

The vast variety of nuclear security applications require radiation detection materials tailored to their operational needs. A scintillator’s properties are strongly influenced by the choice of luminescent dopant, which facilitates customization to different applications. In this work, transparent Ø12 mm single crystals of undoped CsCaCl 3 , CsCaCl 3 :1% Eu, CsCaCl 3 :1% Tl, and CsCaCl 3 :1% Eu, 1% Tl were grown via the Vertical Bridgman method. Their scintillation properties and fast neutron-gamma discrimination capabilities were investigated. Undoped CsCaCl 3 had a light yield of 2,500 ph/MeV, which is the highest reported to date for this CVL material. The incorporation of Eu 2+ or Tl + into CsCaCl 3 as luminescence centers resulted in significantly higher light yields of ∼16,000 ph/MeV and energy resolutions of ∼8% at 662 keV. Compared to the single dopant counterparts, CsCaCl 3 :Eu, Tl had significantly suppressed afterglow; however, this came at the cost of reduced light yield. Among the materials tested, only CsCaCl 3 :Tl showed effective fast neutron and gamma discrimination capabilities, achieving a Figure of Merit of 3.2 between gamma-rays and fast neutron captures that produce protons and 1.6 between gamma-rays and fast neutron captures that produce alpha particles.

crystal growth↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Assessment of the Imaging Properties of Plastic Scintillators at FP60R for Neutron Imaging Applications [Slides]

4mm thick Stilbene gives the brightest signal but at the cost of resolution. 1 and 2 cm BC412 gave the highest resolution images. The HI-LY scintillator is better suited for DD neutrons. Future work includes: measurements this summer using an event-mode imaging camera which promises sub-pixel resolution through center-of-mass techniques, opportunities for DD neutron tests during laser-driven z-pinch experiments at UNR, and assess scatter within scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗