Search NASA⌕ Search

SEARCH · Search NASA

Results for “noise suppression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Noise suppression characteristics of peripherally segmented duct liners

The acoustic fields and transmission losses produced in semi-infinite circular ducts with peripherally segmented liners are analyzed using a series expansion of hard-wall duct modes. The coefficients of the series are computed using Galerkin's method. Unlike finite element approaches, this analysis includes the effects of realistic sources and the number of peripheral strips need not be small. It is shown that peripherally segmented liners redistribute the acoustic energy in waves composed of only a single circumferential mode at the source into other waves which contain a multitude of circumferential modes in the lined section. The accuracy of eigenfunctions computed from the analysis was observed to increase as either the frequency or radial mode order increased. The transmission losses were found to be accurate at frequencies above the cut-on value of the first-order radial mode in a hard-wall duct. The results show that for plane wave sources, peripherally segmented liners may attenuate as much sound as an optimized uniform liner at the optimal point while giving more noise suppression at most other frequencies.

Watson, W. R.↗

Effects of simulated flight on fan noise suppression

Attenuation properties of three treated fan inlets were evaluated in the NASA-Lewis Anechoic Wind Tunnel using a subsonic tip speed, 50.8 cm-diameter fan. Tunnel flow simulated the inflow clean-up effect on source noise observed in flight and allowed observation of the blade passage frequency tone cut-off phenomenon. Acoustic data consisted of isolated inlet noise measured in the far field at two positions and with traverses at four frequencies. Averaged attenuation properties showed relative agreement of the inlets with their design intent; however, tunnel flow significantly affected the attenuation spectra. With no tunnel flow the strong blade passage tone was more highly attenuated than the adjacent broadband noise. With tunnel flow, when cut-off was observed, the attenuation at the tone frequency was comparable to that for broadband noise. Tunnel flow increased by several dB the maximum attenuation occurring at midfrequencies of the attenuation spectra. The combined effect of tunnel flow on attenuation and source noise resulted in suppressed fan noise levels throughout the spectra. Tunnel flow caused some substantial directivity variations that are interpreted as acoustic mode changes, with tunnel flow generally reducing the proportion of modes near cut-off.

Heidmann, M. F.↗

Comparator With Noise Suppression

Comparator continuously and automatically adjusts noise immunity period. High-gain amplifier used in conjunction with multivibrator 4 to provide clear pulse to multivibrator 1 at first negative-going zero crossing of input signal. Once multivibrator 1 cleared, output goes to zero volts and not retriggered until next time positive input exceeds reference level. Since input signal noise at zero crossing does not exceed reference level, no effect on multivibrator 1 operation. Circuit fabricated using standard solid-state operational amplifiers, multivibrators, OR gates, and passive elements.

Batts, C. N.↗

Supersonic jet noise suppression using coaxial flow interaction.

The scope of investigations conducted with coaxial interacting supersonic jet flows covers (1) acoustic measurements in both the far noise field and near noise field, (2) surveys of mean flow properties and fluctuating pressures, optical visualization of interacting jet flows, the associated flow and shock structure changes and the noise field, (3) the effects of different geometrical parameters of the coaxial nozzles, and (4) thrust measurements. It is shown that the flow interaction between two suitable controlled interacting coaxial supersonic axisymmetric jet flows results in substantial noise reduction based on equivalent thrust considerations. This flow interaction technique appears to be potentially an attractive approach for suppression of noise from supersonic jet exhausts.

Dosanjh, D. S.↗

Sub-Poissonian light and photocurrent shot-noise suppression in closed opto-electronic loop

We examine experimentally photocurrent noise reduction in the opto-electronic closed loop. Photocurrent noise density 12.5 dB below the shot-noise was observed. So large suppression was not reached in previous experiments and cannot be explained in terms of an ordinary sub-Poissonian light in the loop. We propose the concept of anticorrelation state for the description of light in the loop.

Masalov, A. V.↗

Adaptive Noise Suppression Using Digital Signal Processing

A signal to noise ratio dependent adaptive spectral subtraction algorithm is developed to eliminate noise from noise corrupted speech signals. The algorithm determines the signal to noise ratio and adjusts the spectral subtraction proportion appropriately. After spectra subtraction low amplitude signals are squelched. A single microphone is used to obtain both eh noise corrupted speech and the average noise estimate. This is done by determining if the frame of data being sampled is a voiced or unvoiced frame. During unvoice frames an estimate of the noise is obtained. A running average of the noise is used to approximate the expected value of the noise. Applications include the emergency egress vehicle and the crawler transporter.

Kozel, David↗

Mesoscale system feedback-induced dissipation and noise suppression

A high-gain and low-noise negative feedback control (“feedback control”) system can detect charge transfer in quantum systems at room temperatures. The feedback control system can attenuate dissipative coupling between a quantum system and its thermodynamic environment. The feedback control system can be integrated with standard commercial voltage-impedance measurement system, for example, a potentiostat. In one aspect, the feedback control system includes a plurality of electrodes that are configured to electrically couple to a sample, and a feedback mechanism coupled to a first electrode of the plurality of electrodes. The feedback mechanism is configured to detect a potential associated with the sample via the first electrode. The feedback mechanism provides a feedback signal to the sample via a second electrode of the plurality of electrodes, the feedback signal is configured to provide excitation control of the sample at a third electrode of the plurality of electrode.

Gupta, Chaitanya↗

Noise suppression by time exposure oscilloscope photography.

We describe a simple and inexpensive means of enhancing repetitive signals obscured by noise with roughly equal amplitude. The signal and noise are displayed on an oscilloscope, and we perform a time average over many traces by time exposure photography. If the oscilloscope triggering is synchronous with the signal, the result is a significant suppression of the offending noise.

Huchital, G. S.↗

Noise suppression by an acoustically treated three-ring inlet on a TF-34 engine

Acoustic performance tests were conducted with a three-ring inlet noise suppressor designed for a TF-34 engine. For all tests the aft noise sources were highly suppressed. The measured inlet suppression was large, reaching levels greater than 30 db at the peak. Comparisons of the data and the performance predictions were in reasonably good agreement. The frequency of peak attenuation was well predicted; the magnitude and spectral shape were reasonably well predicted. Agreement was best when the distribution of sound energy across the inlet was taken into account in the performance predictions. Tests in which the length of treatment was varied showed an orderly progression of attenuation with length; performance predictions for the different lengths also showed an orderly progression with length. At the highest speed of the engine, multiple pure tones were present throughout the spectrum in the source noise signature. These tones were effectively suppressed by the inlet liner, even at low frequencies, although the liner was designed to work best at the blade-passing frequency.

Minner, G. L.↗

Method for suppressing noise in measurements

Techniques of combining separate but correlated measurements to form a second-order or higher order correlation function to suppress the effects of noise in the initial condition of a system capable of retaining memory of an initial state of the system with a characteristic relaxation time. At least two separate measurements are obtained from the system. The temporal separation between the two separate measurements is preferably comparable to or less than the characteristic relaxation time and is adjusted to allow for a correlation between two measurements.

Carson, Paul J.↗

Initial results of a porous plug nozzle for supersonic jet noise suppression

As part of a continuing study of possible methods of jet noise reduction, some tests have been made on a porous plug type noise suppressor. Very little information exists on the aeroacoustic performance of jet nozzles having porous elements designed to eliminate the shock wave in the exhaust stream and by so doing to eliminate the shock associated noise and screech. Some initial results on the aeroacoustic performance of a model porous plug type jet noise suppressor are presented. Included are shadowgraph pictures of the flow exhausting from the porous plug nozzle with the comparable acoustic far-field spectra and cross correlations which illustrate the benefits of the test device.

Maestrello, L.↗

Coaxial supersonic jet-flows, shock structure and related problems with noise-suppression assessment and prediction

It is now reasonably well established that the intense noise radiated by a single turbulent, heated, under or overexpanded round jet of high specific thrust can be significantly reduced if instead, 'equivalent' multinozzle coaxial supersonic jet flows of the same total thrust and mass flow rate were to be operated in the inverted pressure mode. A summary of some of the relevant observations on the coaxial supersonic jet flows and their shock structure is presented. Attention is given to the scope of the optical studies, the development of shock structure, the effects of exit stagger, coaxial supersonic jet flows with inner nozzle overexpanded, the role of the lip thickness, the role of the exit area ratios, cold/heated coaxial supersonic jet flows, acoustic observations, the conventional pressure mode of operation, comparative noise reduction assessment, and problems and prospects of noise prediction.

Dosanjh, D. S.↗

High-precision phase control of an optical lattice with up to 50 dB noise suppression

An optical lattice is a periodic light crystal constructed from the standing-wave interference patterns of laser beams. It can be used to store and manipulate quantum degenerate atoms and is an ideal platform for the quantum simulation of many-body physics. A principal feature is that optical lattices are flexible and possess a variety of multidimensional geometries with modifiable band structure. An even richer landscape emerges when control functions can be applied to the lattice by modulation of the position or amplitude with Floquet driving. However, the desire of realizing high-modulation bandwidths while preserving extreme lattice stability has been difficult to achieve. In this paper, we demonstrate an effective solution that consists of overlapping two counterpropagating lattice beams and controlling the phase and intensity of each with independent acousto-optic modulators. Our phase controller mixes sampled light from both lattice beams with a common optical reference. This dual heterodyne locking method allows exquisite determination of the lattice position, while also removing parasitic phase noise accrued as the beams travel along separate paths. Here, we report up to 50 dB suppression in lattice phase noise in the 0.1–1 Hz band, along with significant suppression spanning more than 4 decades of frequency. The absolute phase diffusion of the lattice position is only 10 Å when integrated over 10 s. This method permits precise, high-bandwidth modulation (greater than 50 kHz) of the optical lattice intensity and phase. We demonstrate the efficacy of this approach by executing intricate time-varying phase profiles for atom interferometry.

Atom interferometry↗

Fan noise suppression

The principal suppressor parameters and their relationships have been used to formulate a suppressor design methodology which has been applied to the design of several full-scale suppressors. Tests of these suppressors on several full-scale fans have demonstrated noise reductions of the order of 10 PNdB. The amount of suppression in several instances seems to have been limited by reaching noise floors that are not clearly at the estimated jet noise level but are not far above it. In addition to identifying noise floors, two other areas are considered. The first is attenuation by the fan exhaust suppressors, which seems in most cases to be less than that of the inlet. The second is the effectiveness of outer cowl treatment alone on multiple pure tones. This question relates to whether a high-speed fan can become as quiet as a low-speed fan without a substantial increase in the amount of treatment.

Feiler, C. E.↗

Design of a Low Speed Fan Stage for Noise Suppression

This report describes the design of a low tip speed, moderate pressure rise fan stage for demonstration of noise reduction concepts. The fan rotor is a fixed-pitch configuration delivering a design pressure ratio of 1.378 at a specific flow of 43.1 lbm/sec/sq ft. Four exit stator configurations were provided to demonstrate the effectiveness of circumferential and axial sweep in reducing rotor-stator interaction tone noise. The fan stage design was combined with an axisymmetric inlet, conical convergent nozzle, and nacelle to form a powered fan-nacelle subscale model. This model has a 22-inch cylindrical flow path and employs a rotor with a 0.30 hub-to-tip radius ratio. The design is fully compatible with an existing NASA force balance and rig drive system. The stage aerodynamic and structural design is described in detail. Three-dimensional (3-D) computational fluid dynamics (CFD) tools were used to define optimum airfoil sections for both the rotor and stators. A fan noise predictive system developed by Pratt & Whitney under contract to NASA was used to determine the acoustic characteristics of the various stator configurations. Parameters varied included rotor-to-stator spacing and vane leading edge sweep. The structural analysis of the rotor and stator are described herein. An integral blade and disk configuration was selected for the rotor. Analysis confirmed adequate low cycle fatigue life, vibratory endurance strength, and aeroelastic suitability. A unique load carrying stator arrangement was selected to minimize generation of tonal noise due to sources other than rotor-stator interaction. Analysis of all static structural components demonstrated adequate strength, fatigue life, and vibratory characteristics.

Dalton, W. N.↗

Effects of Simulated Flight on Fan Noise Suppression

Attenuation properties of three treated fan inlets were evaluated. Tunnel flow simulated the inflow clean-up effect on source noise observed in flight and allowed observation of the blade passage frequency tone cut-off phenomenon. Acoustic data consisted of isolated inlet noise measured in the far field at two fixed positions and with traverses at four frequencies. Attenuation and source noise properties with and without flight simulation are compared and discussed. Averaged attenuation properties showed relative agreement of the inlets with their design intent, however, tunnel flow significantly affected the attenuation spectra.

Heidmann, M. F.↗